Spirax-Sarco Industrial Thermostatic Steam Traps

Similar documents
Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

THE THERMOSTATIC STEAM TRAP

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Steam Traps and Steam Specialties

UNIVERSAL STYLE STEAM TRAPS WU450 Series

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

THERMOSTATIC STEAM TRAPS

Inverted Bucket Steam Traps

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

PIP PNE00004 Steam Trap Guidelines

Air Vents for Hot and Chilled Water Systems

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Liquid Drainers LIQUID DRAINERS

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

STEAM TRAPS

CD-33/CD-33S Controlled Disc Steam Traps

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

FT14 Ball Float Steam Trap (Screwed)

Hoffman Specialty General Catalog

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Economical and simplified solutions that offer quality and optimum steam trap service.

LIQUIDATOR UMT-TD Series Thermodynamic

Catalog No. 108-C. Steam Traps

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Thermostatic Steam Traps

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

LIQUIDATOR 450 SERIES

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Wide range of steam traps that provide consistent performance in less than perfect conditions.

13-1. Temperature Regulator

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS

MFP14 Automatic pumps for condensate and other industrial fluids

Why steam trap survey?

THERMODYNAMIC STEAM TRAPS

INSTALLATION AND MAINTENANCE INSTRUCTIONS. IM US March RediHeat. Table Of Contents. I. Installation RediHeat Start-Up Procedure 4

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Hydrocarbon & Chemical Processing Solutions

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

1 of 127. Unicron Engineering ULTRASONIC TRAP TESTER UTT 100 CONDENSATE DRAIN VALVES CDV 32

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

The right trap for the right application.

Pamphlet M2012 BALANCED PRESSURE THERMOSTATIC STEAM TRAPS

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Series 1140 and 1141 Temperature Regulators

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

MFP14 Automatic pumps. for condensate and other industrial fluids

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

Intelligent System Solutions Steam Air Hot Water

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

SECTION SECTION DESIGN REQUIREMENTS

THERMODYNAMIC STEAM TRAP

GESTRA Information A 1.5

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

Pure Performance For Steam Mains and Tracers

Bringing Energy Down to Earth

Chapter 2.3: Steam System

STEAM CONSERVATION GUIDELINES

Inverted bucket steam traps Type OKZ PN6/PN16

DESIGN STANDARDS SECTION 15600

Thermostatic expansion valves for ammonia Type TEA

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

So far 2010 is proving to be

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

Technical and Dimensional Data. Saf-T Vent SC Plus

Intelligent Refrigeration Solutions

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

TEMPERATURE CONTROLLERS

Our Know-How. Your Peace of Mind. Steam Solutions

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Pamphlet A2000. TL\l. Free Float Steam Trap Series

Water Fuel + Air for combustion Blowdown

ESCO. Committed. Group of Companies. to help conserve Steam Energy

Radiator Trap Radiator Valve

Blowdown Separator & Aftercoolers

Transcription:

State Supply Saint Paul, MN Toll Free: 8072.2099 Fax: 651.774.7156 www.statesupply.com Spirax-Sarco Industrial Thermostatic Steam Traps Spirax-Sarco TM600 & TM600L Use as Either Steam Trap or ir Vent Designed for use on steam systems operating up to 600 psi and 650 F. Ductile iron body with stainless steel diaphragm. s a steam trap it removes all condensate and non-condensable gases from the equipment being trapped and returns the discharge toward the boiler. and ¾ connections. Turn it upside down, plug the angle-side inlet and it s a thermostatic air vent! Can be installed on all steam equipment up to its maximum ratings. and ¾ connections. DIMENSIONS 4.2 1 Shown as a Thermostatic Steam trap TM600 shown Upside Down it s an ir Vent! Shown as a Thermostatic ir Vent ¾ ngle Inlet Plugged. Guide 2 Max. Steam PSI 1. Cap 2. Element Set with 2.8 6.25 SG1141 SH1128 SH1137 3/4 SG1141 600 TM600 1/2 TM600L 1/2 SG1142 3/4 SG1142 2.0 Spirax-Sarco T250 High Pressure Steam Trap Select from Straight or ngle Pattern Connections Dimensions ngle Pattern Straight The Spirax-Sarco T250 has a welded, self-adjusting stainless steel element that discharges hot condensate at approximately 20 F. below the any saturated steam temperature up to 450 F. Max. Operating pressure: 250 psi Max. Operating Temp: 450 F. ody Construction: Cast Iron Operating Internals: Stainless Steel T250 Pattern C D Cap () Kit ( thru E) 1/2 3.5 1.75 1.75 3.12 4.56 SG1145 SH1075C SH1060 3/4 3.5 90 ngle 1.75 1.75 3.12 4.56 SG1150 SH1075C SH1070 1 6.0 2.12 2.25 3.9 5.37 SG1165 SH1075 SH1095 1/2 4.3 1.75 1.75 3.12 5.37 SG1143 SH1075C SH1060 Straight 3/4 4.3 1.87 1.75 3.12 5.37 SG1144 SH1075C SH1070 Online: www.statesupply.com State Supply Co., Inc. Copyright 1987-2014 2

State Supply Toll Free: 8072.2099 Fax: 651.774.7156 Contact: Sales@StateSupply.com Spirax-Sarco PC32 Carbon Steel Thermostatic Traps PC32 Standard Less PC32Y With uilt-in Conn. 1 C D F *STD *SU Cover s: low Down & ody low Down 3.1 SG1010 SW 3.1 SG1010C SH1003E ¾ 3.1 SG1010E ody for PC32 ¾ SW 3.1 SG1010G & PC32Y 1 3.3 SG1010H 1 SW 3.3 SG1010K SH1003 SH1003 SH1003C 3.5 2.1 SG1010L SW 3.5 2.1 SG1010M SH1003G ¾ 3.5 2.1 SG1010N low Down for ¾ SW 3.5 2.1 SG1010P PC32Y SH1003H 1 4.0 6.3 2.3 SG1010R Only. 1 SW 4.0 6.3 2.3 SG1010T lso available in NSI 150 or 300 flanged connections. Not shown here. ll Traps listed above come with the STD operating capsule: Discharges condensate at 22 F below steam saturation temperature. Dimensions These Spirax-Sarco Thermostatic Steam Traps efficiently operate at steam pressures up to 465 psi, and temperatures up to 572 F. The traps come equipped with a Standard (STD) operating capsule that opens to discharge hot condensate at 22 F. below saturated steam temperature. The model PC32Y comes with an integral stainless steel strainer. The trap should be installed on a horizontal plane with the cover at the top, and preferably with a drop leg immediately preceding the trap. When installing a socket weld model there is no need to remove the element first as long as welding is electric arc method. NSI 150 and 300 flanges optional. * The STD capsule opens to discharge condensate at 22 F below steam saturation temperature. The SU capsule opens to discharge condensate at 43 F below steam saturation temperature. Capacities, PPH Condensate ody Includes Email: Sales@StateSupply.com State Supply Co., Inc. Copyright 1987-2014 3

State Supply Saint Paul, MN Toll Free: 8072.2099 Fax: 651.774.7156 www.statesupply.com Spirax-Sarco TSS-300 & DTS-300 Thermostatic Steam Traps TSS-300 & DTS-300 oth the DTS and TSS-300 are very similar except that the TSS-300 is used where no back-up of condensate should be tolerated - In other words, hot condensate must be quickly discharged. Therefore: The TSS-300 is for critical and non-critical steam tracing systems and main drips. The DTS-300 is for non-critical steam tracing systems only. Either installed vertically or horizontally. oth models feature ll Stainless Steel odies, internals plus the following: alanced pressure operational element that discharges condensate at approximately 20 F below saturated steam temperature Maximum operating pressure: 300 psi. Maximum operating temperature: Saturated steam temperature at 300 psi. oth models Fail open. TSS-300 Capacity, PPH DTS-300 Capacity, PPH Guide - ll Stainless Steel Construction. No repair parts. Dim. inch SG1174 TSS-300 ⅜ SG1174 1.5 DTS-300 0.8 SG1174E ⅜ SG1174C oth the TTS-300 and DTS-300 are factory sealed for tamper-proof operation, and no repair parts are available. Spirax-Sarco SP30LC Thermostatic Steam Traps The Spirax-Sarco SP30LC has an all stainless steel construction, both internals and body. The welded stainless steel operating element is self-adjusting over the entire operating pressure range and will discharge condensate at approximately 18 F. below saturated steam temperature. The stainless steel operating element is resistant to water hammer and super heat up to 90 F. over saturated steam temperature can be tolerated. Typical applications include kitchen and hospital equipment, steam tracers, steam coils, steam radiators and steam main drip stations. Maximum Operating Temp: 500 F Maximum Operating Press: 435 psi Tamper-proof ody, No repair parts. Preferred installation: Horizontally Resists water-hammer and freezing Withstands up to 90 F. Superheat SP30LC Dimensions, inches D 2.2 3.1 2.2 5 SG1174T ¾ SG1174V C Online: www.statesupply.com State Supply Co., Inc. Copyright 1987-2014 4

State Supply Toll Free: 8072.2099 Fax: 651.774.7156 Contact: Sales@StateSupply.com Spirax-Sarco MST21 & MST1H Thermostatic Steam Traps D C The Spirax-Sarco MST21 (standard capacity) and MST21H (higher capacity) have all stainless steel construction and can adjust to all steam operating pressures up to 304 psi. Three discharge temperatures offered: 40 below steam saturation temperature; 7 below saturation and the other almost at saturation (steam) temperature. Preferred installation is a vertical pattern. If installed horizontally to the ground the trap should be preceded by a short drop leg. If used as an air vent, install inverted - Outlet on top. Internal element withstands water hammer and temperatures to 518 F. The internal element assembly and cover gasket are readily available repair parts MST21 MST21H Open Temperature, F. t or below steam saturation temp. C D Complete ¼ 40 Subcool 0.8 2.0 0.3 0.4 1.8 SG1172E SH1002 ¼ 18 Subcool 0.8 2.0 0.3 0.4 1.8 SG1172F SH1002C ¼ Near Steam Temp. 0.8 2.0 0.3 0.4 1.8 SG1172G SH1002 40 Subcool 1.1 2.4 0.5 0.6 1.8 SG1172H SH1002 18 Subcool 1.1 2.4 0.5 0.6 1.8 SG1172K SH1002C Near Steam Temp. 1.1 2.4 0.5 0.6 1.8 SG1172M SH1002 40 Subcool 1.1 2.4 0.5 0.6 1.8 SG1172N SH1002 18 Subcool 1.1 2.4 0.5 0.6 1.8 SG1172P SH1002C Near Steam Temp. 1.1 2.4 0.5 0.6 1.8 SG1172R SH1002 ¾ 18 Subcool 1.1 2.7 0.6 0.6 1.8 SG1172T SH1002C ¾ 40 Subcool 1.1 2.7 0.6 0.6 1.8 SG1172U SH1002 ¾ Near Steam Temp. 1.1 2.7 0.6 0.6 1.8 SG1172V SH1002 1 18 Subcool 1.1 3.0 0.6 0.6 1.8 SG1172W SH1002C 1 40 Subcool 1.1 3.0 0.6 0.6 1.8 SG1172X SH1002 1 Near Steam Temp. 1.1 3.0 0.6 0.6 1.8 SG1172Y SH1002 Cover Only SH1002E Capacities of Condensate Discharge, PPH Complete Cover Only Email: Sales@StateSupply.com State Supply Co., Inc. Copyright 1987-2014 5

State Supply Saint Paul, MN Toll Free: 8072.2099 Fax: 651.774.7156 www.statesupply.com Spirax-Sarco SMC32 & SMC32Y imetallic Steam Traps These Spirax-Sarco SMC32 Thermostatic Steam Traps have a carbon steel body and bimetallic operating element and stainless steel internals. They efficiently operate at steam pressures up to 465 psi, and temperatures up to 662 F. The trap should be installed on a horizontal plane with the cover at the top, and preferably with a drop leg immediately preceding the trap. When installing a socket weld modelthere is no need to remove the element first as long as welding is electric arc method. NSI 150 and 300 flanges optional. To expedite easy servicing of the trap please install isolating valves both upstream and down stream of the steam trap. SMC32 Standard Less SMC32Y With uilt-in Conn. 1 C D F imetallic Cover low Down 3.1 SG1011 ¾ ¾ 1 SW SW 3.1 3.1 3.1 3.3 SG1011 SG1011C SG1011E SG1011F SH1040C ody for SMC32 & SMC32Y 1 SW 3.3 SG1011G SH1040 SH1040 3.5 2.1 SG1011H SW 3.5 2.1 SG1011K SH1040E SH1040F ¾ 3.5 2.1 SG1011L ¾ SW 3.5 2.1 SG1011M for SMC32Y only 1 4.0 6.3 2.3 SG1011N 1 SW 4.0 6.3 2.3 SG1011P Dimensions lso available in NSI 150 or 300 flanged connections. ll Traps listed above discharge condensate slightly below steam saturation temperature. Capacities, PPH Condensate ody imetallic Thermostat Includes Online: www.statesupply.com State Supply Co., Inc. Copyright 1987-2014 6

State Supply Toll Free: 8072.2099 Fax: 651.774.7156 Contact: Sales@StateSupply.com Spirax-Sarco HP High Pressure imetallic Steam Traps External djustment Knob to Control Temp. of Condensate Spirax Sarco s HP45, HP80, HP100, HP150 and HP 210 Spirax-Sarco models HP45, HP80, HP100, HP150 and HP 210 are designed for very high pressure steam: Maximum steam working pressures from 652 psi ( HP45) to 3045 psi ( HP210). Forged steel body with stainless steel operating internals and integral stainless steel strainer screen ensure both robust and efficient operation. HP series (except HP45) include a check valve to prevent problems associated with backpressure. ll models have an external adjusting control to allow the discharge temperature of the condensate to be controlled. These steam traps operate with no loss of steam and quickly expel air and large quantities of cold water on start-up. HP45 Capacities Sample HP150 Shown HP80, HP100, HP150 & HP200 Capacities HP45 HP80 HP100 HP150 HP210 Max. Work PSI Conn 7.6 SG1098 ¾ 7.6 SG1098 1 17.6 SG1098C 652 SG1098E ¾ SW 17.6 SG1098F 1 SG1098G SG1098H ¾ 1160 SW 20.9 SG1098K 1 SG1098L SG1098M ¾ 1450 SW 23.2 SG1098N 1 SG1098P SG1098R ¾ 2175 SW 25.4 SG1098T 1 SG1098U SG1098V ¾ 3045 SW 25.4 SG1098W 1 SG1098X *imetallic SH1040G Kit SH1040H SH1040N SH1040K SH1040L SH1040M Includes Valve Seat, Cover & Top Nut s Only SH1040P SH1040R Check Valve Not able SH1040T Dimensions, inches C HP45 HP80 HP100 HP150 HP210 6.3 5.4 ¾ 6.3 5.4 1 6.3 5.4 6.3 5.7 ¾ 6.3 5.7 1 6.3 5.7 8.3 6.6 ¾ 8.3 6.6 1 8.3 6.6 C HP80 to HP210 *imetallic Includes ll s (valve seat, cover & top nut), & i-metal Element. Check Valve HP45 Email: Sales@StateSupply.com State Supply Co., Inc. Copyright 1987-2014 7