Guide to condition reports for domestic electrical installations.

Similar documents
Guide to Condition Reports for Domestic Electrical Installations

Consumer unit replacement in domestic and similar premises

Part P and how it affects you

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

EMERGENCY LIGHTING COMPLETION CERTIFICATE For small installations and verification of existing installations

Periodic inspection reporting - recommendation codes for domestic and similar electrical installations

DCP3/ DETAILS OF THE CLIENT ADDRESS OF THE INSTALLATION

Who are the Electrical Safety Council? Contents. Page

Who are the Electrical Safety Council? Contents. Page

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

Electrical Safety Policy

Application for Up-Grade Approved Electrician

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Application for the Issue of Initial SJIB Grade (ECS) Card

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

Understanding and implementing an electrical safety regime in your organisation. Dispelling the myths and promoting a risk-based approach

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

PERIODIC ELECTRICAL TESTING POLICY

Safety and Instruction Manual

Alan Wells Technical and Standards Director Certsure LLP trading as NICEIC

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa

Periodic Electrical Testing Policy

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

DOMESTIC INSTALLATIONS COMMERCIAL INSTALLATIONS LIGHTING SOLAR PV REPAIRS LANDLORDS SWITCH ON TO SWH ELECTRICAL SOLUTIONS

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Electrical Contractors Association. presents. The Hidden Perils of Poor Electrical Installation in Domestic Property

Managing Ex Asset Integrity

Use numbers given in the box to complete the following sentences. In the UK, the mains electricity supply is volts.

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

Guide to: 17 th Edition Consumer Units

meters explained The benefits How it works Water efficiency

Electric Warm-Stretch under floor heating

Inventory + Check In

FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS

Asbestos. asbestos in your home.

Initial Application for Emergency & Security Systems Operatives SJIB Grade (ECS) Card

Inventory + Check In

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Your specialist partner for total electrical compliance. Electrical Testing

Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry

LANDLORD S GUIDE. The Landlord s Guide to the Gas Safety Regulations Electrical Equipment (Safety) Regulations Who must comply?

User Information Sheet 008 : 2010

dhf General Information Automated Gates Guidance for enforcement bodies

A guide to landlords duties: Gas Safety (Installation and Use) Regulations What type of property is covered?

ELECTRICAL INSTALLATION PERMIT HOMEOWNER

AIR CONDITIONING UNIT

Diamond Cut 360 Cordless Jug Kettle Cool Touch Plastic

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011

Complete the table to show which size fuse, 3 A or 13 A, should be fitted to each of the appliances. Appliance Power Fuse

HULME MARTIN HEAT SEALERS

User s Operation Instructions & Important Warranty Information

DEVIL CERAMIC SPACE HEATERS

INSTRUCTIONS MODEL: P9EO

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

Deaf & Hearing Impaired RadioLINK Alarm System

Effectiveness of sprinklers in residential premises:

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Guide to sollysta Wiring Accessories

SUMET09 Maintain electrical systems and equipment (SQA Unit Code- H956 04)

Electrical Safety Policy and Management System

THE SAFE USE OF ELECTRICITY

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

the Compact Kettle Pure

Preventing deaths and injuries in the home in Scotland

Whole Room Dryer WRD, WRD/110

2 IN 1 JUICER AND BLENDER

Initial Application for ECS Related Discipline Card

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co.

DIPLOMA IN DIPL INTERIOR DESIGN

Safety and Instruction Manual

If you wish to make payment by card please complete the attached SJIB Payment Request form and submit with your application form.

BT16.4SS-HK BT19.4SS-HK Cooker Hood

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Read the instructions and keep them safe. Pass them on if you pass the kettle on. Remove all packaging, but keep it till you know the kettle works.

Telephone: Mobile Number.

Guide to Membership Assessments

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Read the instructions and keep them safe. If you pass the iron on, pass on the instructions too. Remove all packaging, but keep it till you know the

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Approved Accessible by our tenants. Maintenance in my home

ELECTRICAL FIRE SAFETY

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

TT302 (200W) Wireless receiver Pull cord Dimmer

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

Initial Application for Fire Detection & Alarm Systems Operatives SJIB Grade (ECS) Card

WASH FILTER REGISTER FOR YOUR FREE 5 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY. click. click. click. click. click. months

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

Aluminum Heating Mantles

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

Please read and keep these instructions for future use

Safety and Instruction Manual PLEASE READ CAREFULLY

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

SUMET05 Install and connect electrical cables, conductors, wiring systems and equipment

Baxi Maxflow Combi WM

Transcription:

Guide to condition reports for domestic electrical

Courtesy of Greater Manchester Fire and Rescue Service What is an electrical installation? An electrical installation is a fixed wiring system made up of equipment, such as a consumer unit (fuse box), lighting and power circuits, and switches and sockets. An electrical installation does not include electrical appliances, such as cookers, heaters and washing machines. cupboards, so it is not surprising that we forget to check the condition of our electrical for damage or wear and tear. Faulty and old wiring is one of the main causes of electrical fires in the home. You can reduce the risk a fire by having the condition of your cables, switches, sockets and other accessories checked regularly. How old is my electrical installation? Clear signs that can help you tell the age of equipment in the electrical installation in your home include the following. Fixed cables coated in black rubber (which stopped being used in the 1960s). Fixed cables coated in lead or fabric (used before the 1960s). A fuse box with a wooden back, cast iron switches, or a mixture of fuse boxes (used before the 1960s). Older round pin sockets, braided flex hanging from ceiling roses, brown (or black) switches, or sockets mounted in or on skirting boards (used before the 1960s). Why do I need to get the electrical installation in my home (or the home that I am planning to buy) checked? You cannot see electricity. Cables are usually hidden inside our walls, and consumer units are often hidden in Examples of equipment often found in electrical from before the 1960 s.

If your electrical equipment is similar to those shown on the previous page, it is likely that your installation is over 40 years old and it may need rewiring completely. If not, your home (or the home that you are planning to buy) is probably wired with cables insulated in pvc (used in since the 1960s), so it is unlikely that it will need completely rewiring. However old your electrical installation is, it may get damaged and will suffer from wear and tear. So you should get an electrician to check its condition at least every 10 years or when you move into a new property. Definitions Cables Wires that carry electricity. Condition report A report on the condition of an electrical installation. It will explain the condition of the electrical equipment, show whether it is damaged (or worn out) and say whether or not it is safe to use. Consumer unit (often called a fuse box) Equipment used to supply and control electricity around the home. It usually contains a main switch, fuses or circuit-breakers and one or more residual current devices (see RCD). Current Flowing electricity. Electrical installation A fixed wiring system made up of equipment, for example a consumer unit, and lighting and power circuits. Electrical installation certificate A certificate given when new electrical installation work is finished. IET Wiring Regulations Also called BS 7671 Requirements for Electrical Installations. This is the UK Standard for electrical. Electrical installation condition report (EICR) A condition report, which includes the results from inspecting and testing an electrical installation. Residual current device (RCD) A sensitive switching device that cuts off a circuit when it finds a fault to earth that might cause an electric shock or a fire. Visual condition report A condition report that includes the results from inspecting but not testing an electrical installation.

What is the aim of a condition report? You may need a condition report for a number of reasons, such as when selling or buying a property. Or, you may need a report to find out the condition of an installation after a flood or fire, or at the end of the period recommended in a previous electrical certificate or report. The five main aims of a condition report are to: 1 record the results of the inspection and testing to make sure the electrical installation is safe to be used until the next inspection (following any work needed to make it safe); 2 find any damage and wear and tear that might affect safety, and report it; 3 find any parts of the electrical installation that do not meet the IET Wiring Regulations; 4 help find anything that may cause electric shocks and high temperatures, which can lead to deaths, burns, fires and other injuries; and 5 provide an important record of the installation at the time of the inspection, and for inspection and testing in the future. Types of condition report In general, there are two types of report applicable to a domestic installation. Visual condition report Electrical installation condition report Inspection and testing of electrical appliances, often called portable appliance testing (PAT), is not included in either of these reports. Details on inspecting and testing electrical appliances are not included in this leaflet. You can get more information on inspecting and testing electrical appliances from our website at

DPN5/1 Visual condition reports A visual condition report will include the results of the inspection of the electrical installation. A visual condition report does not include testing, so the inspection is not likely to find hidden damage to equipment (for example, damage to cables and joints). Usually, a visual inspection report is only suitable if the installation has been tested in the last couple of years, and the results were reported (on an electrical installation certificate or an electrical installation condition report) as being satisfactory (good enough). This safety report is an important and valuable document which should be retained for future reference. DETAILS OF THE CLIENT AND INSTALLATION Client : Type of dwelling: PARTICULARS OF CONTRACTOR Trading Title: Telephone : OBSERVATIONS AND RECOMMENDATIONS FOR ACTION TO BE TAKEN See note Referring to the attached schedule of inspection results: There are no visually-evident items affecting electrical safety Item 1 $ Please see the reverse of this page for guidance regarding the recommendations. Urgent remedial action recommended for Items: Corrective action(s) recommended for Items: DOMESTIC VISUAL CONDITION REPORT or SUMMARY OF THE CONDITION OF THE INSTALLATION General condition of the installation: Approximate age of the installation: Evidence of alterations or additions: DECLARATION I being the person responsible for the visual inspection of the electrical installation (as indicated by my signature below), particulars of which are described above, having exercised reasonable skill and care when carrying out the inspection, hereby declare that the information in this report, including the observations and the attached schedules, provides an accurate assessment of the condition of the electrical installation taking into account the limitations of a visual-only inspection. I further declare that in my judgement the condition of the said installation is : Tick as appropriate Unsatisfactory, significant damage, Visually not unsatisfactory, or deterioration and/or defects being evident. Name (CAPITALS): The following observations and recommendations are made. Code $ NEXT INSPECTION Enter interval in terms of years months or weeks as appropriate I recommend that this installation is further inspected after an interval of not more than: and that the inspection is: Please tick one box Full periodic or Visual condition See note Original (To the person ordering the wo An example of the front cover of a visual condition report te: If necessary, continue on additional page(s) which must be referenced specifically to this report. Please see the tes for Recipients on the reverse of this page. Page 1 of Electrical installation condition reports In general, we recommend an electrical installation condition report rather than a visual condition report. This is because testing will give you more information about the condition of the electrical installation, particularly the presence of hidden damage to equipment, such as cables and joints. An example of the front cover of an electrical installation condition report. DOMESTIC ELECTRICAL INSTALLATION CONDITION REPORT (FOR A SINGLE DWELLING) Issued in accordance with British Standard 7671 Requirements for Electrical Installations by an Approved Contractor or Conforming Body enrolled with NICEIC, Warwick House, Houghton Hall Park, Houghton Regis, Dunstable LU5 5ZX. A. DETAILS OF THE CLIENT D. EXTENT OF THE INSTALLATION AND LIMITATIONS ON THE Client: INSPECTION AND TESTING Extent of the electrical installation covered by this report: Agreed limitations including the reasons, if any, on the inspection and testing: B. PURPOSE OF THE REPORT Agreed with: Purpose for which Operational limitations including the reasons (see page. ) this report is required: The inspection and testing have been carried out in accordance with BS 7671, as amended. Cables concealed within trunking Date(s) on which inspection and conduits, or cables and conduits concealed under floors, in inaccessible roof spaces and generally within the fabric of and testing were carried out: the building or underground, have not been visually inspected. C. DETAILS OF THE INSTALLATION E. SUMMARY OF THE CONDITION OF THE INSTALLATION General condition of the installation (in terms of electrical safety): Occupier: Original (To the person ordering the work) Always make sure that you agree the type of report with your electrician, before the inspection (and testing) starts. Estimated age of the electrical installation: Date of previous inspection: Records of installation available: years Records held by: Evidence of alterations or additions Electrical Installation Certificate or previous Periodic Inspection or Condition Report : If yes, estimated age This report should have been reviewed and confirmed by the registered Qualified Supervisor of the Approved Contractor responsible for issuing it. (See declaration on page 2) This report is based on the model forms shown in Appendix 6 of BS 7671. Copyright The Electrical Safety Council (July 2011) years Summary of the condition of the installation continued on additional pages? Specify page (s): Overall assessment of the installation: SATISFACTORY / UNSATISFACTORY (Delete as appropriate) An Unsatisfactory assessment indicates that dangerous and/or potentially dangerous conditions have been identified Please see the tes for Recipients on the reverse of this page. Page 1 of

Who should produce your condition report? There are no government-approved schemes in the UK that register electricians to carry out periodic inspection and testing of existing electrical. However, the following organisations do register electricians that may be able to carry out this work, although their schemes may not cover the whole of the UK. Before hiring an electrician to carry out any work, check with the organisation who has registered them, to make sure they are approved to carry out this type of work. By using an electrician registered with one of these organisations to carry out the periodic inspection and testing of the electrical installation, you should receive a detailed condition report of the electrical installation. If you decide to use an electrician who is not registered with one of the schemes mentioned above, it is your responsibility to make sure that the electrician has the necessary skills and experience to carry out the work. Information about the electrician s technical qualifications can help you to decide whether an electrician is able to do the work, but you need to take great care if this is all that you are basing your decision on. British Standards Institution Phone: 01442 230 442 Website: www.bsi-global.com Electrical Contractors Association Phone: 0207 313 4800 Website: www.eca.co.uk EC Certification trading as ELECSA Phone: 0845 634 9043 Website: www.elecsa.org.uk NAPIT Registration Ltd Phone; 0843 0330 Website: www.napit.org.uk NICEIC Phone: 0870 013 0382 Website: www.niceic.com SELECT Phone: 0131 445 5577 Website: www.select.org.uk

DEICRQRF - 02/09 This guide is for people who would like to get a domestic electrical installation condition report for their property or for a property they are planning to buy. It includes information on: how to get a quote from an electrician for your electrical installation condition report; how to order your report; what happens during inspection and testing; and what to do after you receive your condition report. This information supports the information in our Guide to condition reports for domestic electrical, which you can get from our website at. The guide to condition reports for domestic electrical includes: a description of what an electrical installation is; reasons why the installation in your home (or the home that you are planning to buy) should be checked; information on the age of equipment (fuse boxes, wiring, switches and sockets and so on) in electrical ; definitions; reasons for carrying out reports and types of condition report; and how to find an electrician and order your condition report. Guide to condition reports for domestic electrical How to get a quote for your condition report To get a quote from an electrician 13 Will any children or pets be in the home during the If, please give details of any special safety measures that the inspection and testing? electrician may need to take during the inspection (and testing). (or you may want to get a competitive quote from several 14 Do you agree to reset clocks or timers on electrical equipment after the inspection and testing is finished? electricians) for a condition report (For example, the central-heating timer and clocks on DVD recorders.) Step 3 Ask the electrician to fill in the relevant parts of the form. If '' please give details of any items that you you would like the electrician to reset'. on the electrical installation in your 15 Is there access to all buildings outside the property If, please give details of where access is not available. (such as sheds and garages) that are connected to the property or the property you are installation? Quotation request form 6 Electrician giving the quote: planning to buy, you can follow the B) Extra price for a return visit to carry out live testing if power is for a Domestic Electrical Installation Condition report not available on the first day of testing (for example, if the 16 Do you agree to provide a safe working environment If, please give details of where there are dangers to the power fails or a meter runs out of credit): three steps shown. for the electrician? electrician. (For example toys, DIY tools or other items that the electrician may trip on or that may fall on them should be moved to a safe place.) Date the work will start: Date the work will be finished: If you are the customer If you are the electrician Step 1 C ) Price to put right any problems listed in Section 18. (Write the You should fill all sections of the form, except for You should fill in sections 6 and 9 of the form 17 Are there any limits the time of the test and when If, please give details. price if you know it, if not, write Price to be agreed ): sections 6 and 9. and return it to the customer. the supply can be switched off? Decide which of the following two (For example, an appliance is not to be switched off a certain You should then send the quotation request to D) Payment conditions: time of the day?) the electrician to get a quote. A) Price for the condition report: domestic electrical installation You may decide to get a competitive quote by sending a form to several electricians. condition reports you need. 18 Do you want the electrician to carry out any work to If, please list the work that needs to be done, for example 7 Type of condition report: (Tick one box) put right any problems? replace damaged switch in garage. 1 Customer s details: (See our documents: Domestic Electrical installation condition Visual condition report reports Information for customers, and Domestic Electrical (includes inspection but not testing). installation condition reports Information for electricians.) Periodic inspection report Visual condition report (includes Date when the work must be finished: (includes inspection and testing) (We recommend this in most cases.) 8 What will the inspection (and testing if appropriate) inspection but not testing) include? For example, the main home, and the shed and garage (if they run off the consumer unit). 19 Do you agree that the electrician can take photographs of any problems with the electrical Periodic inspection report installation for the report? 9 Limits: Wiring is hidden in walls and under floors, in spaces in the roof 2 Access arrangements or special requirements: that cannot be reached and in the structure of the building or (includes inspection and underground, so it cannot be inspected. (Please list any other This form has been produced by: limits, for example inaccessible socket-outlets or other accessories, The Electrical Safety Council such as where they are fixed behind a double wardrobe, may not be inspected or tested.) testing) 18 Buckingham Gate, London, SW1E 6LB Phone: 0870 040 0561 Fax: 0870 040 0560 Email: enquiries@esc.org.uk 3 Budget Web: conditions (if any): Registered Charity. 257376 10 Are lamps in light fittings working and available for Step 2 The Electrical Safety Council is an independent charity committed to reducing the electrician to use? deaths and injuries through electrical accidents at home and at work. (For example, for general lighting and for testing the operation of light switches.) DEICRQRF - 02/09 Fill in the relevant parts of our 11 Is there easy access to all equipment? If, please give details of why access is not available or For example, to bonding and earthing clamps, the consumer unit restricted. and accessories. Domestic electrical installation condition report quotation request 12 Are previous records that give the history of the If, please give details of records that are available. installation available? (For example, test certificates and condition reports.) form, which you can get from our website at How to order your electrical installation condition report Once the electrician has filled in the relevant parts of the quotation request form and returned it to you, if you are satisfied with it, you can ask the electrician to produce your domestic electrical installation condition report. Domestic Electrical Installation Condition Reports 5 4 Connecting a microgeneration system to a domestic or similar electrical Electrical installation Guidance on safe isolation procedures and their impact on the for low voltage of buildings: fire performance Part 1 - Domestic premises: Single family units (houses, flats, maisone t es, bungalows) 3 2 Periodic inspection reporting - recommendation codes for domestic and similar electrical insta lations Issue 2a (in para lel with the mains supply) 1 Replacing a in consumer unit in domestic premises where lighting circuits have no protective conductor (For example, the central-heating timer and clocks on DVD recorders.) (For example toys, DIY tools or other items that the electrician may trip on or that may fall on them should be moved to a safe place.) sections 6 and 9. If, please give details of any special safety measures that the electrician may need to take during the inspection (and testing). If, please give details of where there are dangers to the electrician. You should fill all sections of the form, except for You should fill in sections 6 and 9 of the form If, please give details. and return it to the customer. You should then send the quotation request to (For example, an appliance is not to be switched off at a certain time of the day?) the electrician to get a quote. You may decide to get a competitive quote by sending a form to several electricians. 18 Buckingham Gate, London, SW1E 6LB Phone: 0870 040 0561 Fax: 0870 040 0560 Email: enquiries@.org.uk Web: www..org.uk Registered Charity. 257376 is an independent charity committed to reducing deaths and injuries through electrical accidents (Tick at home one box) and at work. DEICRQRF - 02/09 Cheque Debit card Credit card Cash (you can tick more than one box) When the work is finished Payments at agreed stages Will you pay a deposit? If '' please give details of any items that you you would like the electrician to reset'. If, please give details of where access is not available. for a Domestic Electrical Installation Condition report If, please list the work that needs to be done, for example replace damaged switch in garage. Date when the work must be finished: 5 4 6 Electrician giving the quote: A) Price for the condition report: 7 Type of report: (See our documents: Information for customers for Domestic Electrical installation condition reports, and Information for electricians - Domestic Electrical installation condition reports.) B) Extra price for a return visit to carry out live testing if power is not available on the first day of testing (for example, if the power fails or a meter runs out of credit): Date the work will start: Date the work will be finished: C ) Price to put right any problems listed in Section 18. (Write the price if you know it, if not, write Price to be agreed ): D) Payment conditions: (Tick one box) Visual condition report (includes inspection but not testing). Electrical installation condition report (includes inspection and testing) (We recommend this in most cases.) 8 What will the inspection (and testing if appropriate) include? For example, the main home, and the shed and garage (if they run off the consumer unit). 9 Limits: Wiring is hidden in walls and under floors, in spaces in the roof that cannot be reached and in the structure of the building or underground, so it cannot be inspected. (Please list any other limits, for example inaccessible socket-outlets or other accessories, such as where they are fixed behind a double wardrobe, may not be inspected or tested.) 10 Are lamps in light fittings working and available for the electrician to use? (For example, for general lighting and for testing the operation of light switches.) 11 Is there easy access to all equipment? If, please give details of why access is not available or For example, to bonding and earthing clamps, the consumer unit restricted. and accessories. 12 Are previous records that give the history of the If, please give details of records that are available. installation available? (For example, test certificates and condition reports.) system to a domestic or recommendation codes Electrical for domestic and installation similar Guidance on electrical safe isolation and their impact on the of buildings: Part 1 - Domestic premises: Single family units (houses, flats, maisonett es, bungalows) 3 2 reporting - (in parallel with the mains supply) Issue 2a 1 in Replacing a consumer unit in protective conductor How can I order my condition report? You can get information about how to order your condition report, and more information on condition reports, in the following documents, which you can download from our website at. Information for customers Domestic electrical installation condition reports. 13 Will any children or pets be in the home during the If, please give details of any special safety measures that the inspection and testing? electrician may need to take during the inspection (and testing). 14 Do you agree to reset clocks or timers on electrical If '' please give details of any items that you would like the equipment after the inspection and testing is finished? electrician to reset'. (For example, the central-heating timer and clocks on DVD recorders.) 6 Electrician giving the quote: B) Extra price for a return visit to carry out live testing if power is 15 Is there access to all buildings outside the property If, please give details of where access not is not available available. on the first day of testing (for example, if the (such as sheds and garages) that are connected to the power fails or a meter runs out of credit): installation? Date the work will start: Date the work will be finished: 16 Do you agree to provide a safe working environment If, please give details of where there are dangers to the C ) Price to put right any problems listed in Section 18. (Write the for the electrician? electrician. price if you know it, if not, write Price to be agreed ): (For example toys, DIY tools or other items that the electrician may trip on or that may fall on them should be moved to a safe place.) D) Payment conditions: A) Price for the condition report: 17 Are there any limits on the time of the test and when If, please give details. the supply can be switched off? (For example, an appliance is not to be switched off at a certain time of the day?) 7 Type of condition report: (Tick one box) for a Domestic Electrical Installation Condition report (See our documents: Information for customers for Domestic Visual condition report Electrical installation condition reports, and Information for (includes inspection but not testing). electricians - Domestic Electrical installation condition reports.) Periodic inspection report 18 Do you want the electrician to carry out any work to If, please list the work that needs (includes to be done, inspection for example and testing) (We recommend this in most cases.) put right any problems? replace damaged switch in garage. 8 What will the inspection (and If testing you if are appropriate) the customer If you are the electrician include? For example, the main home, and the shed and garage (if they run You should fill all sections of the form, except for You should fill in sections 6 and 9 of the form off the consumer unit). sections 6 and 9. and return it to the customer. 9 Limits: You should then send the quotation request to Wiring is hidden in walls and under floors, in spaces in the roof the electrician to get a quote. 19 Do you agree that the electrician that can cannot take be reached and in the structure of the building or photographs of any problems underground, with the electrical so it cannot be inspected. (Please list any other You may decide to get a competitive quote by installation for the report? limits, for example inaccessible socket-outlets or other accessories, such as where they are fixed behind sending a double wardrobe, a form may to several not electricians. be inspected or tested.) This form has been produced by: 1 Customer s details: The Electrical Safety Council 18 Buckingham Gate, London, SW1E 6LB Phone: 0870 040 0561 Fax: 0870 040 0560 Email: enquiries@esc.org.uk Web: 10 Are lamps in light fittings working and available for the electrician to use? Registered Charity. 257376 (For example, for general lighting and for testing the operation of light switches.) The Electrical Safety Council is an independent charity committed to reducing deaths and injuries through electrical accidents at home and at work. 11 Is there easy access to all equipment? For example, to bonding and earthing clamps, the consumer unit and accessories. Quotation request form Date when the work must be finished: If, please give details of why access is not available or restricted. 2 Access arrangements or special requirements: 12 Are previous records that give the history of the If, please give details of records that are available. installation available? (For example, test certificates and condition reports.) Information for customers Domestic electrical installation condition reports This guide is for people who would like to get a domestic electrical installation condition report for their property or for a property they are planning to buy. It includes information on: how to get a quote from an electrician for your electrical installation condition report; how to order your report; what happens during inspection and testing; and what to do after you receive your condition report. This information supports the information in our Guide to Guide to condition reports for condition reports for domestic electrical, which you domestic electrical can get from our website at. The guide to condition reports for domestic electrical includes: a description of what an electrical installation is; reasons why the electrical installation is to be checked; information on the age of equipment (fuse boxes, wiring, switches and sockets and so on) in the electrical installation; definitions; types of condition report; and how to find an electrician and order your condition report. How to get a quote for your condition report To get a quote from an electrician (you may want to get a quote from several electricians) for a condition report on the electrical installation in your property or the property you are planning to buy, you can follow the three steps shown. Step 1 Decide which of the following two domestic electrical installation condition reports you need. Visual condition report (includes inspection but not testing) Electrical installation condition report (includes inspection and testing) Step 2 Fill in the relevant parts of our Domestic electrical installation condition report quotation request form, which you can get from our website at Quotation request form How to order your electrical installation condition report Step 3 Ask the electrician to fill in the relevant parts of the form. Once the electrician has filled in the relevant parts of the quotation request form and returned it to you, if you are satisfied with it, you can ask the electrician to produce your domestic electrical installation condition report. 3 Budget conditions (if any): Information for electricians Domestic Electrical Installation Condition Reports. Quotation Request Form for a Domestic Electrical Installation Condition Report. Quotation request form 4 How you will pay: (Tick one box) Cheque Debit card Credit card Cash for a Domestic Electrical Installation 5 Condition report When and how you will pay (you can tick more than one box): When the work is finished Payments at agreed stages Will you pay a deposit? The aim of this quotation request form is to make it easier for you to order your condition report. This form and associated documents (see below) should help you to get quotations so that you can place an order with an electrician to produce Guide to condition reports for a report that clearly shows whether or not the domestic electrical electrical installation is safe to use. You should read this form with the following documents, which are available from our website at Information for customers Domestic electrical installation condition reports Guide to condition reports for domestic electrical Information for customers Domestic electrical installation condition reports. Also available from the website is the following guidance. Information for electricians Domestic Electrical Installation Condition Reports. 4 How you will pay: (Tick one box) Cheque Debit card Credit card Cash 5 When and how you will pay (you can tick more than one box): When the work is finished Payments at agreed stages Will you pay a deposit? Information for electricians Domestic Electrical Installation Condition Reports fire performance Periodic inspection Connecting a microgeneration similar electrical procedures for low voltage domestic premises where lighting circuits have no Information for electricians

More advice For more advice on any electrical safety issues contact: The Electrical Safety Council Unit 331-3 Great Guildford Business Square, 30 Great Guildford Street, London, SE1 0HS Phone: 020 3463 5100 Fax: 020 3463 5139 Email: enquiries@esc.org.uk Web: Registered Charity (England and Wales). 257376 Registered Charity (Scotland). SC039990 The Electrical Safety Council is a charity committed to reducing deaths and injuries caused by electricity. GCRDEI - rev 1 07/12 Electrical Safety Council