Biological Safety Cabinet

Similar documents
LABORATORY CABINETS 103

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Microbiological Safety Cabinets

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

CLEAN AIR SYSTEM.

PART III. Laboratory equipment

Biological Safety Cabinets. Biological Safety Cabinets

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Safe Operating Procedure (Revised 2/10)

Environmental Health and Safety Biological Safety Program Guidance Document

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Biological Safety Cabinets or Fume Hoods Which one to use?

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

VP, Facilities and Construction Management

Florida International University. Biosafety Cabinet Program

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

2 Microbiological Safety Cabinet

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

ZHENGZHOU FEILONG MEDICAL EQUIPMENT CO.,LTD

BIOLOGICAL SAFETY CABINET

INCREASE YOUR LAB EFFICIENCY

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)

Laminar Flow Cabinets eco air V

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

BioSafety Cabinet- Class 100

Microbiological Safety Cabinets ENVAIR eco safe Comfort

INCREASE YOUR LAB EFFICIENCY

ESCO. LabTech America A M P L E SCIENTIFIC CITIZEN SCALE INC LABOMED, INC. WORLD CLASS, WORLD WIDE. Rev.2

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Bedding Disposal Workstations The Portable Safety Solution for Animal Research Laboratories. Viva Bedding Disposal Workstation, Model VBD-4A_.

Labconco XPress Laboratory Equipment Where You Need It, When You Need It

IVF/ART Series Laminar Flow Cabinets

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Low Noise, Class II Microbiological Safety Cabinets The Industry's Most Comfortable, Energy Efficient Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

INCREASE YOUR LAB EFFICIENCY

Innovation in air purification unmatched air quality

Gelaire BH-EN and UltraSafe cabinets

6/19/2015 BIOLOGICAL SAFETY CABINET. Types of Classes. Types of BSC.

Laboratory Automation & Robotic System Enclosures

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

TOPAIR CLEAN AIR SOLUTIONS CATALOG

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Fortuna. Fortuna. »ScanLaf Probably the best in Class 1, Class 2 and Laminar flow technology.

PCR UV cabinets DNA/RNA

B. Design meeting requirements of the particular class and type of cabinet as follows:

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

PCR UV cabinets DNA/RNA

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

Safe Use of a Class II Biological Safety Cabinet

PCR UV Cabinets. PCR UV cabinet workstation UVT-S-AR PCR UV workstation

FUME CUPBOARDS DESIGN FEATURES GENERAL ARRANGEMENT FACE VELOCITIES EXTRACTION SYSTEMS AIRFLOW CHARACTERISTICS

Mars Pro. Mars Pro. Ultrasafe Class 2 An Ultrasafe Triple Filter - Microbiological Safety Cabinets. Cytosafe 3 filter Class 2 cabinets

Formalin Vaporizer The Premium Solution for Biological Safety Cabinet Decontamination. Esco Formalin Vaporizer Model FV-00_

PROTECTION PRODUCT. Series CleanLamin AirFlow. Cabinets Series CLF, DLF and DLF/PCR

UVC/T-M-AR stainless steel UV cabinet

CIRCULAIRE LAMINAR AIR FLOW

Laminar Flow Hoods and Booths

UVC/T-AR UVC/T-M-AR UVT-S-AR

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

Class II ECO Generation 8 Microbiological Safety Cabinet

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

LAB & BIO SCIENTIFIC INSTRUMENTS SCIENTIFIC. Ver (17-1)

Appendix C IBC Safe Use of Biosafety Cabinets SOP


Class II Biological Safety Cabinets The World's Leading Energy Efficient, Quiet, and Compact Biosafety Cabinet.

OPERATION AND MAINTENANCE MANUAL

L a b o r a t o r y E q u i p m e n t C a t a l o g

INCREASE YOUR LAB EFFICIENCY

Airstream Class II, Biological Safety Cabinet (E-series),

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

Cabinet Series. Maximize your lab space using our ideal heavy-duty steel constructed cabinets. Designed with use of our innovated ventilation system.

ORT6WXA ORT9WXA Slide-out Rangehoods

BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

Fume Hood Safety TYPES OF FUME HOODS

Benchtop CO 2 Incubator. the Oasis 6400 series

Cleanroom Air Showers

Transcription:

Biological Safety Cabinet (Class I & Class II Type A2/B2, Class III) Senova Labtech (Shanghai) Co., Ltd.

Class I Biological Safety Cabinet The Class I biological safety cabinet is an open-front negative pressure cabinet. It provides personnel and environmental protection, but not sample protection. As a partial containment unit, the Class I Biological Safety Cabinet is suitable for work involving low or moderate risk agents (Biosafety Level 1, 2 and 3) where containment is needed but not for sample protection Unlike conventional fume hood, the HEPA filter in the Class I Biological Safety Cabinet protects the environment by filtering air before it is exhausted. With negative pressure, personnel protection is made possible by constant ail flow into the working chamber. Negative-pressure with an open front Soft touch control panel LCD(NovaSafe-768C1)/LED (NovaSafe-540C1&680C1/968C1) display UV lamp for sterilization Providing protection for personnel and environment One-piece 304 stainless steel working surface HEPA filter(99.999% @ 0.3 microns) Protecting operators and environment, but not the samples 304 stainless steel working surface Power coated floor stand with universal casters and brake (NovaSafe-968C1 only) NovaSafe-540C1&680C1 NovaSafe-768C1 NovaSafe-968C1 LED LCD LED 1

Class I Biological Safety Cabinet Model NovaSafe-540C1 NovaSafe-680C1 NovaSafe-768C1 NovaSafe-968C1 Exterior Size (W*D*H) 550*395*730mm 700*550*900mm 900*695*1080mm 1100*695*1924mm Internal Size (W*D*H) 540*385*450mm 680*450*500mm 768*690*580mm 968*695*639mm Display LED LED LCD LED Airflow Velocity > 0.3-0.6m/s > 0.3-0.6m/s > 0.3-0.6m/s > 0.3-0.6m/s Housing Material PMMA PMMA Steel, powder coating Steel, powder coating Working Surface 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel Working Chamber 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel Floor Stand N/A N/A N/A Steel with powder coating 738mm high HEPA Filter 99.999% efficiency @0.3μm 99.999% efficiency @0.3μm 99.999% efficiency @0.3μm 99.999% efficiency @0.3μm Noise <55dB <55dB <60dB <60dB Working Surface Height / / / 740mm Illumination 4W*1 (LED lamp) 8W*1 (LED lamp) 8W*1 (LED lamp) 21W*1 (Fluorescent Lamp) UV Lamp 15W*1 20W*1 20W*1 20W*1 Power Consumption 150W 160W 180W 400W Caster N/A N/A N/A Universal casters with brake Power Supply Standard Accessory 110~220V±10% 50~60Hz LED lampx1 UV lampx2 110~220V±10% 50~60Hz LED lampx1 UV lampx2 110~220V±10% 50~60Hz LED lampx1 UV lampx2 110~220V±10% 50~60Hz Fluorescent lampx1 UV lampx2 Floor standx1 Gross Weight 40kg 60kg 100kg 150kg Packing Size(L*W*H) 755*600*950mm 950*700*1125mm 1050*850*1280mm 1250*840*2250mm 2

Class II Type A2 Biological Safety Cabinet NovaSafe-600A2 Water-proof Socket UV Lamp Fluorescent Lamp Remote Controller Compact design, saving space Centrifugal fan, adjustable speed Microprocessor controlled 70% air recirculation and 30% air exhaust, protecting operators and environment and samples Class 100 cleanness, H14 HEPA filter Large LCD display. Timer(99hr99min) Remote control for all the functions Time reserve function: It can save 30 minutes waiting time after activating the cabinet and sterilization time after operation Negative-pressure surrounding stainless steel working chamber Power-coated steel construction Filter life indicator 253.7nm UV lamp for decontamination, interlock with the motor, front window and fluorescent lamp Motorized front window Voice prompt for airflow alarm, filter replacement alarm and front window alarm Standard configuration: Remote controller, 2 water-proof sockets, fluorescent lamp, 2xUV lamps, drain valve Optional: Floor stand with casters and brake, water tap & gas tap,duct, arm rest, airflow tester, formalin fumigation sterilizer, infrared sterilizer 3

Class II Type A2 Biological Safety Cabinet NovaSafe-600A2 Model Chamber Size (LxWxH, mm) External Dimensions (LxWxH, mm) HEPA Filter Airflow System Display Working Chamber Housing Front Window Safety Opening Height Max. Opening Height Inflow Velocity Downflow Velocity Noise Level Fluorescent Lamp Luminance UV Lamp NovaSafe-600A2 600x500x540 700x650x1230 2 pieces (99.999% efficiency @ 0.3 microns) 70% recycled, 30% exhausted LCD 304 stainless steel Powder coated steel construction Motorized control, with dual-layer safety glass(thickness5mm) 200mm 400mm 0.53m/s±0.025m/s 0.33m/s±0.025m/s <60dB 14Wx1 1000Lux 18Wx1 Water-proof Socket 2 PCS (Total power consumption 500W) Water Tap(Optional) Gas Tap(Optional) Floor Stand Height(Optional) Working Surface Height(Optional) Rated Power Power Supply Weight 1 PC 1 PC 680mm 750mm(Floor stand height included) 500W 110-220V±10%/50-60Hz N.W. 80Kg, G.W. 110Kg Packing Size(W*D*H,mm) 950*850*1430 4

Class II Type A2 Biological Safety Cabinet NovaSafe-1220A2 Control Panel/LCD Power Switch Lock UV Lamp Water/Gas Tap Fluorescent Lamp Water-proof Socket Drain Valve Universal Casters Foot Switch Microprocessor controlled 70% air recirculation and 30% air exhaust, protecting operators and environment and samples Class 100 cleanness Large LCD display Remote control for all the functions. Timer(99hr99min) Time reserve function: It can save 30 minutes waiting time after activating the cabinet and sterilization time after operation Negative-pressure surrounding stainless steel working chamber Power-coated steel construction Filter life indicator Motorized front window 253.7nm UV lamp for decontamination, interlock with the motor, front window and fluorescent lamp Voice prompt for airflow alarm, filter replacement alarm and front window alarm Standard configuration: Remote controller, 2 water-proof sockets, floor stand with casters and brake,foot switch, fluorescent lamp, 2xUV lamps, drain valve Optional: Arm rest, water tap & gas tap, airflow tester, formalin fumigation sterilizer, infrared sterilizer, duct 5

Class II Type A2 Biological Safety Cabinet NovaSafe-1220A2 Model NovaSafe-1220A2 Chamber Size (LxWxH, mm) 1220x600x660 External Dimensions (LxWxH, mm) 1380x750x2290 HEPA Filter 2 pieces (99.999% efficiency @ 0.3 microns) Airflow System 70% recycled, 30% exhausted Display LCD Working Chamber 304 stainless steel Housing Powder coated steel construction Front Window Motorized control, with dual-layer safety glass(thickness 5mm) Safety Opening Height 200mm Max. Opening Height 400mm Inflow Velocity 0.53m/s±0.025m/s Downflow Velocity 0.33m/s±0.025m/s Noise Level <61dB Fluorescent Lamp 40Wx1 Luminance 1000 Lux UV Lamp 30Wx1 Water-proof Socket 2 PCS (Total power consumption 500W) Water Tap 1 PC Gas Tap 1 PC Working Surface Height 750mm Casters Universal casters with brake and leveling feet Rated Power 600W Power Supply 110-220V±10%/50-60Hz Gross Weight 310Kg Packing Size(W*D*H,mm) 1515*870*1950 6

Class II Type A2 Biological Safety Cabinet NovaSafe-900A2/1100A2/1300A2/1600A2/1800A2 Microprocessor controlled 70% air recirculation and 30% air exhaust, protecting operators and environment and samples Class 100 cleanness Negative-pressure surrounding stainless steel working chamber Power-coated steel construction Foot switch for adjustment of opening height(max. 400mm) of front window Timer(99hr99min), LCD display HEPA main filter and exhaust filters(99.999%@0.3 microns) Filter life indicator 253.7nm UV lamp for decontamination, interlock with the motor, front window and fluorescent lamp Front inflow air grids eliminating turbulence and potential contamination Motorized front window with dual-layer safety glass(thickness 5mm) Standard configuration: Remote controller, 2 water-proof sockets, floor stand with casters and brake, foot switch, fluorescent lamp, UV lamp, drain valve Optional: Arm rest, water tap and gas tap,duct,airflow tester, formalin fumigation sterilizer, infrared sterilizer 7

Class II Type A2 Biological Safety Cabinet Model NovaSafe-900A2 NovaSafe-1100A2 NovaSafe-1300A2 NovaSafe-1600A2 NovaSafe-1800A2 Chamber Size(LxWxH,mm) 940x600x660 1100x600x660 1300x700x660 1710x600x660 1800x600x660 External Dimensions (LxWxH, mm) 1100x750x2250 1300x850x2200 1500x840x2280 1870x750x2290 1950x800x2305 HEPA Filter 2 pieces (99.999% efficiency @ 0.3 microns) Airflow System 70% recycled, 30% exhausted Display LCD Working Chamber 304 stainless steel Housing Powder coated steel construction Front Window Motorized control, with dual-layer safety glass(thickness 5mm) Safety Opening Height 200mm 200mm 200mm 200mm 200mm Max. Opening Height 400mm 400mm 400mm 400mm 400mm Inflow Velocity 0.53m/s±0.025m/s 0.53m/s±0.025m/s 0.53m/s±0.025m/s 0.53m/s±0.025m/s 0.53m/s±0.025m/s Downflow Velocity 0.33m/s±0.025m/s 0.33m/s±0.025m/s 0.33m/s±0.025m/s 0.33m/s±0.025m/s 0.33m/s±0.025m/s Noise Level <65dB <65dB <65dB <65dB <65dB Fluorescent Lamp 21Wx1 21Wx1 28Wx2 40Wx2 40Wx2 Luminance 1000Lux 1000Lux 1000Lux 1000Lux 1000Lux UV Lamp 18Wx1 18x1 30Wx1 40Wx1 40Wx1 Water-proof Socket 2 PCS (Total power consumption 500W) Water Tap(Optional) 1 PC 1 PC 1 PC 1 PC 1 PC Gas Tap(Optional) 1 PC 1 PC 1 PC 1 PC 1 PC Working Surface Height 750mm Caster Universal, with brake and leveling feet Rated Power 760W 1060W 1300W 1350W 1700W Power Supply 110-220V±10%/50-60Hz Gross Weight 255Kg 305Kg 350Kg 390Kg 420Kg Packing Size (W*D*H,mm) 1250*1050*1870 1450*1050*1870 1640*1040*1860 1940*1050*1960 2090*1050*1860 8

Class II Type B2 Biological Safety Cabinet Exhaust Duct Exhaust Blower Remote Controller Power Lock LCD Display Reversed Access for Water & Gas Tap Water-proof Socket Foot Switch Microprocessor controlled 100% air exhausted, protecting operators and environment and samples Class 100 cleanness Negative-pressure surrounding stainless steel working chamber Power-coated steel construction Foot Switch for adjustment of opening height(max. 400mm) of front window Timer(99hr99min), LCD display Washable pre-filter. HEPA main filter and exhaust filter(99.999% @ 0.3 microns) Filter life indication 253.7nm UV lamp for decontamination, interlock with the motor, front window and fluorescent lamp Front inflow air grids eliminating turbulence and potential contamination Motorized front window with dual-layer safety glass(thickness 5mm) Standard configuration: Remote controller, 2 water-proof sockets, exhaust blower, 4-meter exhaust duct (Ø300mm), floor stand with casters and brake, foot switch, fluorescent lamp, UV lamp, drain valve Optional: Arm rest, air curtain tester, water tap and gas tap, formalin fumigation sterilizer, infrared sterilizer Infrared Sterilizer Airflow Tester Formalin Fumigation Sterilizer Arm Rest 9

Class II Type B2 Biological Safety Cabinet Model NovaSafe-900B2 NovaSafe-1100B2 NovaSafe-1300B2 NovaSafe-1600B2 Chamber Size (LxWxH, mm) 940x600x660 1100x600x660 1350x600x620 1600x670x630 External Dimensions (LxWxH, mm) 1100x750x2250 1300x850x2200 1500x760x2250 1800x840x2275 Working Chamber 304 stainless steel Housing Powder coated steel construction Airflow System 100% exhausted Inflow Velocity 0.53m/s±0.025m/s 0.53m/s±0.025m/s 0.53m/s±0.025m/s 0.53m/s±0.025m/s Downflow Velocity 0.33m/s±0.025m/s 0.33m/s±0.025m/s 0.33m/s±0.025m/s 0.33m/s±0.025m/s Front Window Motorized control, with dual-layer safety glass(thickness 5mm) Safety Opening Height 200mm 200mm 200mm 200mm Max. Opening Height 400mm 400mm 400mm 400mm Working Surface Height 750mm Prefilter Washable Washable Washable Washable HEPA Filter 2 pieces (99.999% efficiency @ 0.3 microns Fluorescent Lamp 21Wx1 21Wx1 28Wx2 35Wx2 Luminance 1000Lux 1000Lux 1000Lux 1000Lux UV Lamp 20Wx1 20Wx1 30Wx1 40Wx1 Display LCD Water-proof Socket 2 PCS (Total power consumption 500W) Caster Universal, with brake and leveling feet Noise Level <65dB <65dB <65dB <65dB Rated Power 1050W 1350W 1550W 1900W Power Supply 110-220V±10%/50-60Hz Gross Weight 350Kg 360Kg 440Kg 470Kg Packing Size Main Unit 1250*1050*1970mm 1450*1050*1870mm 1640*1050*1860mm 1940*1050*1860mm (W*D*H) Exhaust Blower 1060*970*580mm 1060*970*580mm 1060*970*580mm 1060*970*580mm 10

Class III Biological Safety Cabinet NovaSafe-1300III Class III Biological Safety Cabinet is totally enclosed and gas-tight with ULPA filtered inflow air and exhaust air. It is performed with long-sleeved gloves and kept under negative pressure of at least 120Pa, thus airflow is maintained by a dedicated exhaust airflow system. It provides protection for the operator, sample and environment. Pressure Meter Remote Controller Fully sealed Front window is sealed, and with a pair of gloves connecting to the working chamber. The sample is transferred by the delivery window. And there is no out-connected valve. 100% air exhaust 100% air exhaust, no air recirculation, and air is exhausted by double ULPA filters(99.999% efficiency@0.1-0.2μm) and to the room directly. If the air needs to be exhausted outdoors, extra exhaust duct and motor need to be ordered. Complete negative pressure The two motors design makes interior of cabinet is complete negative pressure, and can reach -120pa, triple layers filter film, ensures operation s safety, neither substance nor polluted air will leak out. UV lamp for chamber sterilization 11

Class III Biological Safety Cabinet NovaSafe-1300III Model External Dimensions(W*D*H) Chamber Size(W*D*H) Pass Box Size(W*D*H) Gloves Material Negative Work Zone Pressure Airflow Volume Pre-filter ULPA Filter Noise Front Window Display Alarm NovaSafe-1300III 1340*850*2100mm 1240*650*650mm Internal Size: 400*390*340 mm External Size: 480*400*400mm One pair, 800mm butyl rubber gloves Working chamber: 304 stainless steel Housing: Power coated steel -120Pa 440-870cfm Polyester fiber. Washable Air supply filter: ULPA filter: 99.999% efficiency @ 0.1-0.2μm First exhaust filter: ULPA filter 99.999% efficiency @ 0.1-0.2μm Second exhaust filter: ULPA filter 99.999% efficiency @ 0.1-0.2μm 63dB Toughened safety glass, thickness:8mm, anti-ultraviolet radiation LCD Visual and acoustic Fluorescent Lamp 28W*2 Luminance UV Lamp Power Supply Standard Accessory Gross Weight Packing Size(W*D*H) 800 Lux 30W*1,8W*1 110/220V±10%,50/60Hz,700W Gloves, fluorescent light, UV lamp*4,pressure meter, remote controller 395Kg 2000*1000*2220mm 12

NOTES

Senova Laboratory Equipment Biohazard Control Thermal Instrument Histology Equipment Dry Bath,Shaker&Mixer Stirrer, Hotplate Shaker Centrifuge Floor Standing Centrifuge Benchtop Centrifuge Micro Centrifuge Vacuum Concentrator Fume Hood Laminar Airflow Cabinet Class I/II/III Biological Safety Cabinet Double Pier Shaker Horizontal Shaker Stackable Shaker Benchtop Shaker Oven Incubator Water/Oil Bath Muffle Furnace Microtome Tissue Processor Tissue Embedding Tissue Floation Dry Bath Incubator Microplate Shaker Incubator Vortex Mixer Sample Concentrator Magnetic Stirrer Hotplate Water Bath with Stirrer Heating Mantle Room 3001, West Tower, Metro Plaza, 789 Tianshan Road,Shanghai 200051,China Senova Labtech (Shanghai) Co.,Ltd. Tel: +86-21-32508288 Fax: +86-21-32508289 E-mail: senovalab@sina.com Website:www.senovalab.com Information is subject to change and/or updating without notice. Version 201301. Copyright 2013 Senova. All rights reserved.