100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Similar documents
SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

ClearZone Snow Melting Systems

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

CATALOG. Toll Free:

PLSRR Heat Trace Cable Data Sheet

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

ComfortTile Floor Heating Systems

CATALOG. Toll Free:

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

ADDITIONAL INFORMATION

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Electric Floor Heating Cables

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Freezer Frost Heave Prevention

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

SAFETY INFORMATION AND WARNINGS

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

Warranty Info: ETI s warranty policy can be viewed at:

ULTRA-SAFE Explosion-proof Duct Heaters

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM IN EXISTING ASPHALT/CONCRETE

Toll Free:

SIMPLEX WEATHERPROOF CONTROL PANELS

PYROSELF Innovative Snow Sensor and Controller for 2 x 24A loads outputs. Installation and Operating manual

Keep your home snow and ice free with. WARMUP Outdoor Heating Solutions. From the world s best-selling electric floor heating brand

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

Model GIT 4 Gutter Snow and Ice Melting Control

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

FPC-02 Series. Installation and Operating manual

ULTRA-SAFE Explosion-proof Duct Heaters

Two-Position Electric Duplex Room Thermostats

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Toll Free:

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Union County Vocational - Technical Schools Scotch Plains, New Jersey

LMR Electric Fire Pump Controllers Features

Better Design, Better Control, Better Systems.

L J Visit to learn about the Danfoss Installer Certification program. Dual Self-Adhesive Mats. Installs in minutes!

SAFETY INFORMATION AND WARNINGS

LMR Electric Fire Pump Controllers Features

Transfer Switch Features

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

PANELBOARD PROTECTION ON A GLOBAL SCALE

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Centro-Matic Automated Lubrication Systems System Controls

MaxGard. Interconnection Systems. Durability. Performance. Safety

XP Series Non-Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof

Transfer Switch Features

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

Molded Case Circuit Breakers, Bulletin 140G

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Guide Specification Model CTG Automatic Transfer Switch

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Hydronic & HVAC Control Systems

Infrared Electric Heaters - General Product Information

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

Heating Cable. Description

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Q7800H Integrated Burner Control Subpanel

AF/GF dual-purpose receptacles

Wireless Light Detection Sensor

Dräger Flame 2500 Flame Detection

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

C910 Series. Single-point heat-tracing control system

Years. We Believe Experience Matters. Thermostats & Controls

Features: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

CH Series Heavy Duty Metal Sheath Electric Infrared Heater

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

FDF Foam Pump Controllers Features

SECTION AUTOMATIC TRANSFER SWITCHES

ChromaStar. Comfort. Infra-Red Radiant Heaters. Description. Portable. Applications. Fixed Overhead. 1.5 to 13.5 kw. 5,118 to 46,062 BTU/Hr

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

IceStop System Installation and Operation Manual

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

Dräger Flame 2100 Flame Detection

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

PART GENERAL 1.01 SECTION INCLUDES

THERMAL MANAGEMENT SOLUTIONS

Heating Cable. Description

Integrated Solutions. Simple and flexible designs for space and time savings

Type STAR Radiant Heater For Portable Installations

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

PART NO. COMBUSTION AIR CAP

Transcription:

Contactor Panel with GFEP Data Sheet GENERAL PRODUCT INFORMATION Simplify your snowmelt installation with ProLine Radiant contactor panels with built in GFEP. These rugged panels feature built-in ground fault equipment protection to minimize the risk of faults and eliminate extra wiring installation steps and costs. The panel can be activated by a ProLine in-ground or aerial-mount sensor. FEATURES INCLUDE: Low cost Easy to install NEMA 4, UL listed panel box Integrated 30mA GFEP (optional) Pre-wired terminal connections LED trip indicator (internal) LED heat on indicator 120 V on/off remote heat indicator 2-year limited warranty SPECIFICATIONS ProLine contactor panel with GFEP. Power Voltage Range: Maximum Heating Load: Control Voltage: 208 V - 600 V 100A / 200A 120 volt Enclosure Type: NEMA 4 Mounting: Dimensions (H x W x D): GFEP: Wall-mounted (indoor or outdoor) 12 x 10 x 6 (304mm x 254mm x 152mm) 16 x 14 x 6 (406mm x 355mm x 152mm) 30mA trip Contactor Panel (no GFEP) The ProLine contactor panels are designed for snow and ice melting applications. All panels are pre-wired and UL listed complete with a NEMA 4 enclosure, wiring diagram, terminal connection block, and two or four 3-pole contactors. Timer panels can be used stand alone or in conjunction with an automatic controller. Contactor panels must be used in conjunction with an automatic controller. FEATURES INCLUDE: Low cost Easy to install NEMA 4, UL listed panel box Heat on indicator light Pre-wired terminal connections 2-year limited warranty TECHNICAL DATA Power Voltage Range: Maximum Heating Load: Control Voltage: 208 V - 600 V 100A / 200A 120 volt Enclosure Type: NEMA 4 Mounting: Dimensions (H x W x D): Wall-mounted (indoor or outdoor) 12 x 10 x 5 (305mm x 254mm x 127mm) 14 x 12 x 6 (355mm x 305mm x 152mm) 12637 S. 265 W. #100A Draper, UT 84020 Phone: 866.676.9276 ProLine Data Sheet - 1

Contactor Panel 12637 S. 265 W. #100A Draper, UT 84020 Phone: 866.676.9276 ProLine Data Sheet - 2

Contactor Panel 16x14x6 12637 S. 265 W. #100A Draper, UT 84020 Phone: 866.676.9276 ProLine Data Sheet - 3

ORDERING INFORMATION Activation Devices Markers Item Item Number Description Voltage WS-2C Aerial Mounted Snow Switch (30 amps) WS-5 Aerial Mounted Snow Switch (60 amps) WS-8C Aerial Mounted Snow Switch (30 amps) Includes remote moisture sensor WS-AUX Auxiliary Control Unit for Aerial Mounted Snow Switch WS-02 Pavement Mounted Snow Switch and Controller. Marker plate Embedded Marker Plate (NEC Required.) n/a 12637 S. 265 W. #100A Draper, UT 84020 Phone: 866.676.9276 ProLine Data Sheet - 4

ORDERING INFORMATION Timer/Contactor Panels Optional timer panel. Description Single Contactor Panel Dual Contactor Timer Panel with 4 hour timer. Quad Contactor Timer Panel with 4 hour timer. Dual Contactor Timer Panel with 4 hour timer and GFEP. Used to control power supply and heating cables Quad Contactor Timer Panel with 4 hour timer and GFEP. Used to control power supply and heating cables Light Power management electrical box with 2 x 3 pole for zoning, includes moisture and temperature sensor Commercial Power management electrical box with 4 x 3 pole for zoning, includes moisture and temperature sensor Max Amps 50 Coil Voltage 120, 208-240 Number of Contactors 100 120 2 200 120 4 100 120 2 200 120 4 130 120 2 + 1 230 120 4 + 1 Contactor panel with GFEP 1 WARRANTY INFORMATION Controls and Activation Devices: 2-year limited warranty. Snowmelt Mats and Cable: 10-year limited warranty. ProLine snowmelt heat cable is CSA approved for both the U.S. and Canada. TECHNICAL SUPPORT For technical questions, please contact ProLine at 1.866.676.WARM (9276) or via the web, www.prolineradiant.com. ProLine accepts no responsibility for possible errors in catalogs, brochures, other printed materials, and website information. ProLine reserves the right to alter its products without notice. This also applies to products already on order provided that such alteration can be made without subsequent changes being necessary in specifications already agreed upon. All trademarks in this material are property of the respective companies. All rights reserved. 12637 S. 265 W. #100A Draper, UT 84020 Phone: 866.676.9276 ProLine Data Sheet - 5