Technical Manual for the Alarm Pull Station PH1

Similar documents
Technical Manual for the Fire Alarm Call Point - SM87 PBL

Technical Manual for the Strobe - SM87 HXB

Technical Manual for the Horn DB1P UL DB1HP UL

Technical Manual for the Manual Alarm Call Point BG

Technical Manual for the Horn - DB1PUL DB1HP UL

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

Approved by: Document no.: EGT

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

standards: standards:

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Manual Alarm Call Points

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

TECHNICAL MANUAL EXPLOSION PROOF MANUAL CALL POINT BCP 135. Scope: EXcite USER MANUAL BCP 135. Date: Page: Page 1 of 6.

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

An optional Ex e terminal chamber is available (see certification section for further details).

INSTRUCTION MANUAL (ATEX / IECEx)

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

DB4 Range - SPEAKERS - Up to 25 Watts

4) Intrinsic Safety Certification

Flameproof Manual Call Points

Operating Instructions

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

DB5 Intrinsically Safe Sounder Type DB-5

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

Explosion Proof Line Powered Telephone Ringer

Operating Manual Distribution box

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Hazardous Area Zirconia Oxygen Systems

MODELS ASHP, ASHH, ASUP, and ASUH

INSTRUCTION MANUAL (ATEX)

MODELS 304GC, 304GCX, 314GC, and 314GCX

Preventative Maintenance Tables

Easy installation Certified for zones 1 and 21 High IP degree of protection

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing

FUNCTIONAL SAFETY CERTIFICATE. BG Break Glass Unit

Flameproof Manual Call Points Series MCP

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

OPERATION MANUAL.

DB1 Range - HORNS - Up to 103 db(a)

Certificate of Compliance

Instructions. Explosion Proof Smoke Detector U Rev: 9/

Explosion Proof Combination Signal db (A) / 5 Joule

SOUNDER CONTROL MODULE SCM-AS4

Operating Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

TECHNOSKLO Ltd. Držkov

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

Crown Boiler Company

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

DESCRIPTION. 42 mm. 125 mm

SOLARLOK Interconnection System Installation Manual

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

MAN0604_Issue 09_ Apex

TECHNICAL MANUAL EXPLOSION PROOF SOUNDER/ HORN & BEACON BHB 125/ BHB 150. Scope: EXcite USER MANUAL BHB 125 / BHB 150 Date: Page: Checked by: Rev.

Technical Specification VFD

INSTRUCTION MANUAL (ATEX / IECEx)

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

C Electrical Connection Kit

ATM Lighting sp. z o.o

CCTV quick connect Harsh and Hazardous area connectors for camera stations

DETECT-A-FIRE Heat Detectors

Explosion Proof Manual Call Points Series MCP

RE-PR3-E-27 3-Phase Panel Mount 27kW

ATM Lighting sp. z o.o

Flameproof Manual Call Points Series MCP

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Distinction. D4000 & D4000/EURO Water Still. Assembly and Operating Instructions. 1 Issue 2

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Certification Supplement Manual

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Fire Alarm or Emergency Call Points

INSTRUCTION MANUAL (ATEX / IECEx)

CONTROL BE MADE CHANGES MAY NOT. Page 1

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Transcription:

Technical Manual for the Alarm Pull Station PH1 Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense resulting from any error or omission. We reserve the right to make alterations in line with technical advances and industry standards. Cooper MEDC 2013 08/13

08/13 Cooper MEDC 2013

1.0 INTRODUCTION These manual alarm pull stations have been designed for use in hazardous locations and harsh environmental conditions. The GRP enclosures are suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is required 2.0 GENERAL SAFETY MESSAGES AND WARNINGS All instructions and safety messages in this manual must be followed to allow safe installation of the device. The device must only be installed and maintained by correctly trained site personnel/installers. i. To reduce the risk of ignition of hazardous atmospheres and shock, do not apply power to the device until installation has been completed and the device is fully sealed and secured. ii. To reduce the risk of ignition of hazardous atmospheres and shock, keep device tightly closed when the circuit is energised. iii. Before removing the cover for installation or maintenance, ensure that the power to the device is isolated. iv. Following installation, test the device to ensure correct operation. v. Following installation ensure a copy of this manual is made available to all operating personnel vi. When installing the device, requirements for selection, installation and operation should be referred to e.g. IEE Wiring Regulations and the National Electrical Code in North America. Additional national and/or local requirements may also apply. vii. Cable termination should be in accordance with specification applying to the required application. MEDC recommends that all cables and cores should be correctly identified. Please refer to the wiring diagram in this manual (or separate diagram provided with the unit). viii. Ensure that only the correct listed or certified cable glands are used and that the assembly is shrouded and correctly earthed. ix. Ensure that only the correct listed or certified stopping plugs are used to blank off unused gland entry points and that the NEMA/IP rating of the unit is maintained. x. MEDC recommend the use of a sealing compound such as HYLOMAR PL32 on the threads of all glands and stopping plugs in order to maintain the IP rating of the unit. xi. The internal earth terminal, where fitted, must be used for the equipment grounding and the external terminal, if available, is for a supplementary bonding connection where local codes or authorities permit or require such a connection. xii. When installing the device, MEDC recommends the use of stainless steel fasteners. Ensure that all nuts, bolts and fixings are secure. xiii. Blanking plugs are not to be used with the cable entries. xiv. When fitting or removing cable entry glands, the cable entry inserts must be held with a suitable tool to prevent movement. xv. To support the requirements of UL38 Clause 6.1.2, when multiple call points are installed in a single zone the two 18AWG wires required for each of the common incoming and outgoing terminals must be crimped together in a single boot lace ferrule. xvi. Units supplied in any colour other than red are for ancillary use only and shall not be used for fire alarm use 3.0 INSTALLATION The pull station is mounted via the 4 off Ø 6.5mm (Ø 1/4 ) fixing holes in the base of the enclosure. The unit has been designed and certified to operate at any attitude The fixing holes have been designed to accept an M6 screw or bolt. Cable Termination Unscrew the 4 off M6 screws (5.0mm A/F hexagon key) holding the cover assembly to the base. The cover screws are retained in the cover assembly for ease of installation. Gently lift the cover assembly away from the base of the enclosure to gain access to the interior. Once termination is complete, carefully lower the cover assembly back onto the base, avoiding damage to the mating surfaces. Ensure the o-ring is correctly seated in its groove during re-assembly. Evenly tighten the 4 off cover screws (5.0mm A/F hexagon key). The required torque on each explosion-proof enclosure cover screw shall not be less than 40 in-lbs (4.5Nm). Ensure the required gap (0.038mm / 0.0015 Max.) is maintained between the cover and the base. Cooper MEDC 2013 08/13

08/13 Cooper MEDC 2013

Wiring c/w series zener diode Standard wiring c/w series diode and EOL resistor R2 EOL resistor Standard wiring c/w series resistor and EOL diode R1 Series resistor Cooper MEDC 2013 08/13

5.0 OPERATION The unit is operated by lifting the spring loaded flap on the front of the unit, then pulling down the handle underneath. The pull handle will rotate downwards through 90 degrees. The pull handle will remain latched in the operated position until manually reset. The lift flap can be lowered back to its original position until the unit needs to be reset. The reset the unit, first raise the lift flap away from the pull handle. The key (provided with the unit) is inserted into the two holes located underneath the pull handle in the front face until resistance is felt. Depress the key further to release the pull handle which can be returned to its original position. Finally, lower the lift flap back to its original position. Note: When resetting the unit, please ensure the key is depressed centrally with even pressure on each leg of the reset key. The operating voltage of the unit is stated on the certification label GENERAL ARRANGEMENT 6.0 MAINTENANCE During the working life of the unit, it should require little or no maintenance. GRP will resist attack by most acids, alkalis and chemicals and is as resistant to concentrated acids and alkalis as most metal products. However, if abnormal or unusual environmental conditions occur due to plant damage or accident etc., then visual inspection is recommended. If the unit requires cleaning, then only clean exterior with a damp cloth to avoid electro-static charge build up. If a unit fault should occur, then the unit can be repaired by MEDC. All parts of the unit are replaceable. If you acquired a significant quantity of units, then it is recommended that spares are also made available. Please discuss your requirements with the Technical Sales Engineers at MEDC. 08/13 Cooper MEDC 2013

7.0 CERTIFICATION/APPROVALS Please refer to marking on the unit for specific approval details UL Ordinary locations units: UL listed for use in USA (USL) and Canada (CSL) ordinary locations Suitable for indoor or outdoor use. UL Hazardous Locations (Class I, Div. 1) units: UL listed for use in USA (USL) and Canada (CSL) Hazardous locations Class I, Div. 1 & 2 groups B, C & D Class II, Div. 1 & 2, groups E, F & G Class III UL Hazardous Locations (Class I, Div. 2) units: UL listed for use in USA (USL) and Canada (CSL) Hazardous locations Class I, Zone 1, AEx d IIC, Ex d IIC Class I, Div. 2 groups A, B, C & D Class II, Div. 2, Groups F & G Class III UL Standards: UL38, UL50, UL50E, UL1203, ULC528, UL60079-0, UL60079-1, ANSI/ISA 12.12.01 Certified temperature -50 C to +70 C -58 F to +158 F Cooper MEDC 2013 08/13

Cooper MEDC Ltd, Unit B, Sutton Parkway, Oddicroft Lane, Sutton in Ashfield NG17 5FB Tel: +44 (0)1623 444444 Fax: +44 (0)1623 444531 Email: medc.sales@cooperindustries.com medc.orders@cooperindustries.com MEDC Stock No: Web: www.coopermedc.com TM238-ISS.A 08/13 Cooper MEDC 2013