TEMPERATURE CONTROLLER OPERATION MANUAL

Similar documents
TEMPERATURE CONTROLLER OPERATION MANUAL

DC1000 Series Digital Controller Product Manual August 2005

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

CEMA CM20 Series Digital Controller Operation Manual CM24 CM22 CM21 CM23 CM25

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

KC-400 KC-600 KC-700 KC-800 KC-900

Temperature Controllers

Terwin Instruments Ltd.

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

F4 Process Controller Installation and Operation Guide

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

99 Washington Street Melrose, MA Phone Toll Free Visit us at

MICRO CONTROLLER S Z SERIES

Model 96VTR ¼ DIN Process Controller

VERTEX F4 Instruction Manual

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

MICRO CONTROLLER E Z SERIES

Bench-Top Vacuum Oven with 28 segments programmable controller

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

Series Digital Controller Instruction Sheet

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

TEMPERATURE CONTROLLER

TEMPERATURE CONTROL MODULE MODEL R3-TC2

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

4TEMPERATURE CONTROLLER

TC515 and TC600 Installation Manual. a Winters company

R Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

AutomationDirect. PC35 Configuration Sheet

Operation manual for BOD-80. 3, Hagavish st., Holon,Israel Tel: , Fax: Page 1 of 6 pages

SHIMADEN DIGITAL INDICATORS

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Specification , July 2015

+ A B V B NO NC V COM PV PV

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Example of Applications and Parameter Functions

02/11/2015

02/11/2015

MC-5 Series Micro Processor Temperature Controller

Instruction manual for DIN rail mounting type indicating controller DCL-33A

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

Series Temperature Controller Instruction Sheet

Nov 08 PRODUCT SPECIFICATION SHEET

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Instruction manual Micro-computer based digital indicating controller

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

K38 CONTROLLER AND MINI-PROGRAMMER. Engineering Manual General notes about wiring. 1.1 Dimensions. 2.2 Inputs. 1.2 Mounting requirements

TLK39 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr (ENG) - cod.: ISTR 06262

The range of ATR243 controllers comes in three versions. Refer to the table below to easily select your preferred model.

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

INSTRUCTION MANUAL Micro-computer based digital indicating controller

OVEN INDUSTRIES, INC.

SR70 (SR ) Series Digital controller Instruction Manual

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 06261

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

TECHNICAL BULLETIN [ 1/9 ]

Weather compensated flow temperature control of heating and boiler systems

CN4800 Series CONTROLLER

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Instruction manual Temperature Controller KT7

GMH 285 / GMH 285-BNC

CG Series Digital Temperature Controller OPERATIONS MANUAL

UDC100 Universal Digital Controller Specifications

TLK 49 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr. 03 (ENG) - cod.: ISTR TECNOLOGIC S.p.A.

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Installation Manual Tracker 221

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Analog Input Module IC670ALG630

I/A Series Software. Differential Gap (DGAP) Controller Block PSS 21S-3C5 B4 OVERVIEW PRODUCT SPECIFICATIONS

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

ECL Comfort 110, application 116

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

INSTRUCTIONS FOR THE 32A SERIES 1/32 DIN MICROPROCESSOR BASED TEMPERATURE / PROCESS CONTROL

GETTING STARTED. Next, press the INDEX key to display Unit. Press the DOWN ARROW until the display shows C. Press ENTER.

CM 16. Temperature controllers with compact dimensions. Manual 42/61-72 EN Rev. 01

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

ELK 38 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 06261

PID Temperature Controller. ITC-100 User Manual. Version 2.0s. Inkbird Tech. Co., Ltd.

CM 8. Temperature controllers with compact dimensions. Manual 42/61-71 EN Rev. 01

ECL Comfort 110, application 130

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Installer Manual KNX Touchscreen Thermostat

I/A Series 716C 1/16 DIN Temperature Controller

Microprocessor-based digital electronic controller TLK 38

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

CONTENTS. Micro-controller X. Instruction Manual. (Socket type) Model : PXR4 Socket INP-TN1PXR4S-E

Series Temperature Controller Instruction Sheet

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

MICRO CONTROLLER H Z SERIES

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

CONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual. INP-TN1PXR5/9f-E

Humidity Controller Specification and Installation Instructions. Model HRO20

Oven Control System Operation - Ver 2.8

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Transcription:

TEMPERATURE CTROLLER OPERATI MANUAL

OUT1 Before using please check whether range, input and output match your requirement. Thank you for using our microprocessor temperature controller, we have obtained CSA approved NO LR # Mark HCS 519 686 2715. We have also computerized our QC process and testing to provide high quality standard, low price and high functionality in our products. 1. Front panel instruction 2 H 1.1 DISPLAY PV Process value 4 digit display (red color) SV Setting value 4 digit display (green color) 1.2 LED OUT1 Output 1 green color OUT2 Output 2 green color AT Auto Tuning yellow color PRO Program yellow color AL1 Alarm 1 red color AL2 Alarm 2 red color AL3 Alarm 3 red color MAN Manual yellow color *Note: When error occurs, the MAN will light up, and will reset output percentage to zero. 1

1.3 KEY SET MODE SET key SHIFT key DOWN key (Setting value 1, -10, -100, -1000) UP key (Setting value +1, +10, +100, +1000) A/M Auto/Manual key. Automatic The output percentage is determined by internal calculation. Manually The output percentage is determined by manually set OUTL at User Level. 2 Auto tuning 2.2 Once AT is set YESauto tuning is to be performed. 2.3 After auto tuning is finisheda new set of PID parameter is generated internally to replace the existing PID parameter. * Auto tuning allows the controller to automatically adjust the PID parameter, and is suitable for use when temperature control is not accurate enough. 2.4 ATVL=auto tuning offsetand it will be deduced from SV (it can prevent over shoot during auto tuning) SV-ATVL=Auto-tuning valueatvl=auto tuning offset Ex.SV=200 ATVL=5Auto tuning point is at 195 During auto tuning the PV value will oscillate around 195 Hence PV will not go over 200 In programmable modelatvl means Auto-tuning point 2.5 Auto tuning failure Possible Cause 1ATVL is too big. (If not sureset ATVL=0) Possible Cause 2System time is too long. (Set PID parameter individually) 2

3. Error information DISPLAY IN1E ADCF CJCE IN2E UUU1 NNN1 UUU2 NNN2 RAMF INTF AUTF DESCRIPTI Open circuit of main control sensor. A/D converter failed. Cold junction compensation failed. Open circuit of sub control sensor. PV exceeds USPL. PV under LSPL. Input signal of sub control exceeds the upper limit. Input signal of sub control under the lower limit. RAM failed. Interface failed. Auto tuning failed. NOTEIf the marked error comes upthe Controller needs repair. Please send it to the nearest sales office or retail dealer. 3

4. Operating flow 4.1 LEVEL 1 (User Level) Display PV Display SV Output Percentage Auto Tuning Status Alarm 1 set Alarm 2 set Alarm 3 set PV SV set OUTL 100 set AT YES/NO set AL1 0 set AL2 0 set AL3 0 To LEVEL 2 (press Set key for 5 sec.) 4.1.1 Press the SHIFT KEY ( ) to change the parameters. If the SHIFT KEY is pressed the first digit begins blinking. Press the UP KEY( ) or DOWN KEY( ) to increase or decrease the value of the digit then press the SHIFT KEY( ) again to go to the next digit. As all the digit are writtenpress SET KEY to enter the value. 4.1.2 SET KEY also has the function of changing MODEsif the SET KEY is pressedthe display shows the next MODE. 4.1.3 Press SET KEY for 5 sec. the display goes to LEVEL 2and do the same to return LEVEL 1. 4.1.4 If any key were not pressed for 1 minutethe display would go to LEVEL 1. 4.1.5 Press A/M KEY twice will go to LEVEL 1no matter where it is. 4.1.6 If OUTL set "0"it means the controller has no output, 4

4.2 LEVEL 2 (PID Level) press SET key for 5 seconds to enter Level 2 5

4.3 LEVEL 3 (INPUT Level) When LCK=0000press SET key and SHIFT KEY LEVEL 3 for 5 seconds to enter 6

7

5. INPUT 5.1 Input selection (INP1) TYPE CODE RANGE K1 0.0 ~ 200.0/ 0.0 ~392.0 K2 0.0 ~ 400.0/ 0.0 ~752.0 K3 0 ~ 600/ 0 ~1112 K K4 0 ~ 800/ 0 ~1472 K5 0 ~ 1000/ 0 ~1832 K6 0 ~ 1200/ 0 ~2192 J1 0.0 ~ 200.0/ 0.0 ~392.0 J2 0.0 ~ 400.0/ 0.0 ~752.0 J3 0 ~ 600/ 0 ~1112 J J4 0 ~ 800/ 0 ~1472 J5 0 ~ 1000/ 0 ~1832 J6 0 ~ 1200/ 0 ~2192 R1 0 ~ 1600/ 0 ~2912 R R2 0 ~ 1769/ 0 ~3216 S1 0 ~ 1600/ 0 ~2912 S S2 0 ~ 1769/ 0 ~3216 B B1 0 ~ 1820/ 0 ~3308 E1 0 ~ 800/ 0 ~1472 E N T W PL U E2 0 ~ 1000/ 0 ~1832 N1 0 ~ 1200/ 0 ~2192 N2 0 ~ 1300/ 0 ~2372 T1 0.0 ~ 400.0/ 0.0 ~752.0 T2 0.0~ 200.0/ 0.0 ~392.0 T3 0.0 ~ 350.0/ 0.0 ~662.0 W1 0 ~ 2000/ 0 ~3632 W1 0 ~ 2320/ 0 ~2372 PL 1 0 ~ 1300/ 0 ~2372 PL 2 0 ~ 1390/ 0 ~2534 U1-199.9 ~ 600.0/ -199.9 ~999.9 U2-199.9 ~ 200.0/ -199.9 ~392.0 U3 0.0 ~ 400.0/ 0.0 ~752.0 8

TYPE CODE RANGE L1 0 ~ 400/ 0 ~752 L JIS PT100 L2 JP 1 JP 2 JP 3 JP 4 0 ~ 800/ 0 ~1472-199.9 ~ 600.0/ -199.9 ~999.9-199.9 ~ 400.0/ -199.9 ~752.0-199.9 ~ 200.0/ -199.9 ~392.0 0 ~ 200/ 0 ~392 JP 5 0 ~ 400/ 0 ~752 JP 6 0 ~ 600/ 0 ~1112 DP 1-199.9 ~ 600.0/ -199.9 ~999.9 DIN DP 2-199.9 ~ 400.0/ -199.9 ~752.0 DP 3-199.9 ~ 200.0/ -199.9 ~392.0 PT100 DP 4 0 ~ 200/ 0 ~392 DP 5 0 ~ 400/ 0 ~752 DP 6 0 ~ 600/ 0 ~1112 JP.1-199.9 ~ 600.0/ -199.9 ~999.9 JIS JP.2-199.9 ~ 400.0/ -199.9 ~752.0 JP.3-199.9 ~ 200.0/ -199.9 ~392.0 PT50 JP.4 0 ~ 200/ 0 ~392 JP.5 0 ~ 400/ 0 ~752 JP.6 0 ~ 600/ 0 ~1112 AN1 AN1-10 ~ 10mV / -1999~9999 AN2 AN2 0 ~ 10mV / -1999~9999 AN3 AN3 0 ~ 20mV / -1999~9999 AN4 AN4 0 ~ 50mV / -1999~9999 AN5 AN5 10 ~ 50mV /-1999~9999 The initial set in factory is K2 without any certain requirement 9

6. ALARM 6.1 Alarm function selection CODE DESCRIPTI INHIBIT 00 / 10 None 01 Deviation high limit alarm YES 11 Deviation high limit alarm NO 02 Deviation low limit alarm YES 12 Deviation low limit alarm NO 03 Deviation high / low limit alarm YES 13 Deviation high / low limit alarm NO 04 / 14 Deviation high / low limit range alarm NO 05 Absolute value high limit alarm YES 15 Absolute value high limit alarm NO 06 Absolute value low limit alarm YES 16 Absolute value low limit alarm NO 07 Segment end alarm (use for program model only) 17 Program run alarm (use for program model only) 08 System error alarm-on - 18 System error alarm-off - 09-19 On delay timer alarm - Notethe word INHIBIT means that alarm does not work at the first time. - - 10

6.2 Alarm action description 00 10 01 SV Alarm set value (inhibit means alarm doesn't work at the first time) Non Deviation high alarm inhibit 15 06 Absolute high alarm no inhibit Absolute low alarm inhibit Absolute low alarm no inhibit 11 Deviation high alarm no inhibit 16 Segment end alarm (use for PFY Model only) 02 12 03 13 Deviation low alarm inhibit Deviation low alarm no inhibit High low alarm inhibit High low alarm no inhibit Band alarm 07 17 08 18 (1) ALD1~3set 07 (2) AL1~3=alarm segment No.set (3) ALT1~3 if set 0=flicker alarm ALT1~3 if set 99.59=continued alarm ALT1~3 if set others= delay time Program Run alarm(refer to SETA.4 ) (use for PFY Model only) RUN END System error alarm - Normal Error System error alarm - Normal Error AL AL AL 04 14 09 05 Absolute high alarm inhibit 19 On delay timer When PV=alarm SVit keeps a certain period(set time)before alarm action. Range:00H.00M~99H.59M 11

12. Panel cut & Outline Dimension 12.1 Panel Cut Dimension(Unitsmm) A B D C A B C D F16 44.5+0.5 44.5+0.5 65 70 F18H 90.5+0.5 44.5+0.5 111 70 F17 68.5+0.5 68.5+0.5 89 94 F18 44.5+0.5 90.5+0.5 65 116 F14 90.5+0.5 90.5+0.5 111 116 12.2 Outline Dimension (Unitsmm) E F G H E F G H F16 50 50 17 80 F18H 96 50 17 80 F17 74 74 17 80 F18 50 96 17 80 F14 96 96 17 80 12