INSTALLATION INSTRUCTIONS

Similar documents
The skirting board heating system

thermodul cop inglese.qxp :43 Pagina 2 Technical Manual

H E A T I N G A L L A R O U N D

pushing the tube into the rear of the water outlet housing with a slight twisting motion to evenly distribute the adhesive. After cleaning off any ext

Heat Exchanger Block Replacement Instructions

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

Data Sheet. Self regulating process heating tapes RS stock numbers ,

an ISO 9001:2015 Registered Company

Data Sheet. Self regulating heating tapes. RS stock numbers

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Kallista Bath Flip Drain

PolyMax H1-10 Dutch Bucket System

019 ASSEMBLING THE HOTEND

TECHNICAL INSTRUCTIONS

Installation & Operating Guide

Ford Falcon, Ranchero Condenser Kit with Drier (014150)

1. Description. 2. List of Accessories included

KIT CONTENTS Ref Qty Part Description Part Number

Eureka - Fall Maintenance Crew 2017 List of material for plumbing works for sealift 2017

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Chevrolet Pickup Condenser Kit with Drier with Condenser Mounted Forward From Stock Position (021553)

Installation Instructions

PolyMax H2-24 Dutch Bucket System

FIGURE 1. Model RD107

INSTALLATION INSTRUCTIONS

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

INSTALLATION INSTRUCTIONS

OWNERS INSTRUCTION MANUAL

SAN JUAN FRESH WATER COOLING SYSTEMS

INSTALLATION INSTRUCTIONS

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

Dutch Bucket Row Kits

SERGE BARIL GTKB GUT TRACE KIT BAG

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Data Sheet 4.19 Issue C

ZD-985 Desoldering Station

Chevrolet Impala Condenser Kit with Drier (021062)

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

s y ens Av Avensys FIN EST RUS SLO RUS UAE

569, 570, 571, 572 Series

OR Replacement Instructions Heat Exchanger Assembly, ASME

Vent Kit for Condensing Tankless Gas Water Heater

Vari-Cyclone Ceiling Fans

Cooling Strip Model SPB

Installation Instructions

Chapter 3 Cooling, heating and ventilation systems

SERVICE MANUAL FOR MODEL RM-10

Smart Water Heater Controller

Installation manual for room air conditioner

Heat Exchangers DKRCC.PF.000.G1.02 / 520H6410

Notices for installation

Curb Inlet Filter INSTALLATION MANUAL. Bio Clean Environmental Services, Inc. 398 Via El Centro Oceanside, CA 92058

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

FOOD - PHARMACEUTICAL Industrial Vacuum Accessories

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

INTER PLANT STANDARD STEEL INDUSTRY

SERVICE MANUAL FOR MODEL RM-26

INSTALLATION INSTRUCTIONS

Gen II Entree Bath - All Models

1964 ½-66 Ford Mustang Condenser Kit with Drier with Driver Side Connections (011065)

Installation S

Hobble Creek Condos Heating System

INVERTER SPLIT - TYPE

Installation S

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Ti/Lx 150 ASME HX ASSEMBLY

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Installation Manual PS-200 & PS-201

INSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS

MINI SLIMLINE COOL VUY-A VUY-A

Maintaining Packaged Rooftop Units

Regulux. Radiator lockshield with drain-off facility. To be precise.

Helpful Tip: NOTE:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

TOOLS REQUIRED: Crimping tool A/C Recovery Unit Wrench set up to 1 ¼ 4 Hole saw

Electrician Installation Manual Icon 52 inch (132cm) Ceiling Fan

Mopar B-Body Condenser Kit with Drier

Installation Manual PS-225 & PS-275

The skirting board that heats your home...

Avensys Avensys FIN EST SLO RUS UAE

PROJ. NO SECTION REFRIGERANT PIPING

569, 570, 571, 572 Series

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation S

Non-RTD Hot Melt Hose Replacement

REFRIGERANT PIPING

Kawasaki Teryx Firestorm Heater Kit Instructions.

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

TT3000 and TT5000 Series

Making Crimp Connections

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

INSTRUCTION MANUAL with Replacement Parts

an ISO 9001:2008 Registered Company ShortPac HEAT/COOL (05000-QUX-A/05000-VUX-A)

HX Field Replacement Kit

Transcription:

INSTALLATION INSTRUCTIONS Water Model rev 3 06/04/09 Hekos s.r.l. Via Cadola, 13 -Paiane- 31011 Ponte nelle Alpi (BL) -ITALY- Tel +39 0437 999647 Fax +39 0437 999849 info@hekos.com www.hekos.com

THERMODUL components THERMODUL components Immagine art. descrizione SL KA Furnishing element in aluminium with front radiator and upper nib of the cover available in standard white Ral 9010, natural oxidized and dark bronze paint, 2 Support rod in aluminium complete with screw andrawl plug for attachment and profile in plastic (in bars of 2,5 mt.) Heating core with supply and return copper piping External diameter 14,8 mm thickness 0,6 mm, andin fins aluminium (in bars of 2,5 mt.) OA External corner in pvc OI Internal corner in pvc OS End cap in pvc OB 180 return elbow in copper diam. 14 thickness 1 mm OBS OC RC 1415 RC 1515 180 return elbow in copper with venting valve diam. 14 thickness 1 mm (for vertical double solution ) 90 elbow pair in copper diam. 14 thickness 1 mm Compression THERMODUL Fittings 14-15 mm Compression THERMODUL Fittings 15-15 mm PAG 2

Preparation before installing TOOLS REQUIRED -CONSAW (for cutting alluminium profiles) -EXPANDER FOR PIPES WITH HEADS Ø 14-16 mm (weld solution) - pag 8-10 -WELDING TORCH (weld solution) - pag 8-10 -PLIERS FOR CRIMPING FITTINGS (crimp fittings) - pag 11 -CRIMP FITTINGS FF15-14, FF15-15 (crimp fittings) - pag 11 -COMPRESSION FITTINGS (art RC 1415) (compression fittings) - pag 12-13 -COMPRESSION FITTINGS (art RC 1515) (compression fittings) - pag 12-13 -SAW (to cut heating core) -FLAT AND PHILIPS SCREW DRIVERS -STEEL BRUSHES AND SANDPAPERS (cleaning pipes) -PLIERS -CHALK LINE -SCREW DRIVERS -PIPE WRENCH -DRILL -MEASURING TAPE PREPARATION Installation must be performed by qualified personnel and has to be conform with the the country s rules and regulations. The skirting-board heating Thermodul must be installed to end inside works Protect floors to avoid before beginning installation. Packaging (polystyrene, nylon,...) should not be left within the reach of children. PAG 3

Installation stages Installation of Thermodul system happens in 5 stages F1- FIX BRACKETS - pag 5-6 F2- PLACEMENT OF PROFILES AND COMPONENTS IN PVC (OS, OI, OA) - pag 7 F3- INSTALLING THE HEATING CORE F3-1 - Solder joints - pag 8-10 F3-2 - Crimp Fittings - pag 11 F3-3 - Comprssion fittings - pag 12-13 F4- INSTALLING THE SKIRTING UNIT - pag 14 F5- BLEEDING AND BALANCING THE SYSTEM - pag 15 PAG 4

Fix brackets F1 Art. OS 10 cm Art. OT Place a corner (OI) or a terminal (OS) at the end of the wall. Approx 10 cm from it lean the bracket against the wall (art. OT) and mark the spot of the top hole. Do the same on the other side. Drill the holes with a 6 mm drill piece, insert the PVC plug and partially screw a 4x4,5 screw (supplied). Mark the line between the 2 screw making sure that they are at the same height. PAG 5

Fix brackets F1 FOR WALL SHORTEN THAN 2.5 m 50 cm Fix the brackets at 50-60 cm interval along the coloured line on the wall WALL LONGER THAN 2.5 m 50-60 cm 50-60 cm Up Viewer Mark the spot for the bracket to match the placewhere 2 profiles and skirting board meet. To guarantee the fast clip on of the front plate it is very important that all the brackets are fixed at the same height. IMPORTANT! Whereby the walls are not perfectly straight and/or where walls are particularly bad, for best installation install the brackets every 40 cm. PAG 6

Place profiles and components in PVC F2 TO AVOID WASTE OF MATERIAL PLACE ALL 2.5 m PROFILES FIRST THEN COMPLETE THE WALLS WITH PROFILES CUT TO MEASURE To avoid waste material place all the 2.5 profiles first, then complete the walls with the profiles cut to measure. Ensure that profiles are cut to precision for the best result. Screw the brackets tightly to the fix the upper profile to the wall Art. OS 10 cm Lean the terminal (art. OS) onto the door and fix it with screw and plug PAG 7

Solder joints Placing the heating core F3-1 4-5 cm Art KA Verify the meters of heating core required (art. KA) as per drawings and identify the walls where they will be placed. To avoid unnecessary waste of material place all the 2.5 m lenght first and complete by placing the remaining cut to measure Where the heating core is cut it is necessary to remove some of the veins using pliers, clean to avoid any debris. The pipes should be left bare for 4-5 cm HEAD EXPANDER Clean the end of the copper heating core thoroughly with steel wool before soldering PAG 8 As the heating core pipes are 14.8 mm in diameter, it is necessary to expand it by using an expander (such Rems or similar) To connect to other copper pipes use: - 14 mm head for 14 mm pipes - 16 mm head for 16 mm pipes 1 2 copper solder joint can also be used.

Placing the heating core F3-1 CONNECTION KA-KA: øint:14.7 mm To link 2 heating cores (art. KA) expand the pipes using first a 14 mm head (expanding to the end) to bring the internal diameter from 13.5 to 14 mm. They the 16 mm head to expand slightly the diameter from 14 to 14.8 mm. It raccomended not to expand too much to avoid compromising the connection s hold. Solder the pipes using a soldering torch and alloy rod or electric gun and tin-silver alloy. It is recommended that soldering procedures are carried out as much as possible on a worktop. CONNECTION KA-OB: øint:14 mm Art OC With regards to 90 elbow weld the heating core (art. KA) to the 90 elbow (art. OC) after expanding the pipes of the heating core with a 14mm head. Art OB At the end of the circuit weld the heating core (art. KA) to the end elbow 180 (art. OB) after expanding the heating core pipes with 14 mm head PAG 9

Placing the heating core F3-1 Art PL Important! Insert the PVC profiles (art. PL) between the bracket (art. OC) and heating core (art. KA) fixing them directly on the heating core. These are needed to avoid contact between the bracket and the heating core during thermal expansion. BEFORE INSTALLING THE HEATING CORE AND WELDING, TAKE THE CORNERS (art. OI-OA) OUT TO BE PUT IN PLACE IMMEDIATELY AFTERWARDS Place the heating core units already welded together directly on the brackets between the 2 clips. Get the pipes necessary to complete the connections by welding on site or connecting via adapter. Ensure that the heating core (art. KA) is well placed against the brackets. Do a test run with compress air. PAG 10

Crimp Fittings Placing the heating core F3-2 4-5 cm Art KA Verify the meters of heating core required (art. KA) as per drawings and identify the walls where they will be placed. To avoid unnecessary waste of material place all the 2.5 m lenght first and complete by placing the remaining cut to measure Where the heating core is cut it is necessary to remove some of the veins using pliers, clean to avoid any debris. The pipes should be left bare for 4-5 cm Link the heating core using pressure systems such as the Viega adapters and Viega grab. Use copper Adapters FF 15x15 art.2415. Important: The black side of the battery has to face out towards the room. To link the heating core to special parts (elbows 90 degrees and 180 degrees) it is necessary to use bronze Reduction Adapters FF 15x14 art.2215/2. Warning: Place Profiles in PVC as described at page 10. PAG 11

Compression Fittings Placing the heating core F3-3 4-5 cm Art KA Verify the meters of heating core required (art. KA) as per drawings and identify the walls where they will be placed. To avoid unnecessary waste of material place all the 2.5 m lenght first and complete by placing the remaining cut to measure Where the heating core is cut it is necessary to remove some of the veins using pliers, clean to avoid any debris. The pipes should be left bare for 4-5 cm CAP TIGHTEN PIPE REDUCTION GASKET NIPLEX To link the heating cores (art. KA) use compression fittings Thermodul RC 1415 consist, as on detail, of cap, tighten pipe reduction, gasket and niplex. Tighten the fittings 24 mm openend wrench for cap and niplex. PAG 12

Placing the heating core F3-3 CAP TIGHTEN PIPE REDUCTION WASHER GASKET NIPLEX To link the heating cores (art. KA) and the elbows 90 (art. OC) e 180 (art. OB) use compression fitting Thermodul RC 1415. On detail the correct installation of the fitting. On the 14 mm pipe side insert the washer, to permit the correct watertight on 14 mm pipe. It s important tighten the cap to permit at gasket the correct watertight on the pipe to prevent the fitting take off. The minimum Tightening torque it s 40 Nm Warning: Place Profiles in PVC as described at page 10. PAG 13

Installing the skirting unit F4 Before installing the skirting unit, ensure that the brackets are all at the same height. Should there be slight differences bend the bracket s clips gently toward the top or bottom enogh to attach the skirting unit. IMPORTANT! ENSURE THAT THE SKIRTING UNITS MEET RIGHT ON THE BRACKET. For wall longer than 2.5 m clip a complete lenght of skirting unit on the upper clip of the bracket and with a slight pressure from top to bottom. Take precise measurements of missing skirting units, cut them and fix them as described above Where the skirting units meet, drill a hole with a 4 mm pieve on both units at the bottom of the unit. Insert 2 screws (supplied) and screw in (this is to avoid movements of the skirting units during thermal expansion). PAG 14

Bleeding and balancing of the system F5 Once completed the installation, load the system and let all the air out by using the bleeding valves in the manifold or directly from the boiler, if no manifold is avalaible. Proceed to a watertight test to ensure that no leaks are present as per rules and regulations. For a correct functioning of the system, it is important to verify the balancing of the circuits. This can be done from the manifold to avoid that shorter circuits are favoured over longer ones. Maximum pressure of exercise 3 bars. In the case of a retrofit situation and in the absence of a manifold, the balancing should be done along with other radiators/heating system that may be present in the building. Note: PAG 15