INDIVIDUAL HEATING. Installation Manual e Skirting Heating Classic. Skirting Heating Delta. HEATING. COOLING. COMFORT.

Similar documents
INDIVIDUAL HEATING. Design manual e Classic, Delta & Beta skirting heating systems. Planning.

SHSKIRTING HEATING. INSTALLATION.

SHTH SKIRTING HEATING. TRENCH HEATING. The Classic, Delta and Beta skirting heating systems. Trench heating systems.

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Installation Instructions

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Control valves for floor heating systems. Floor Heating Manifolds

CIRCO 6 Solar Circulation Unit

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Mikrotherm. Manual Radiator Valves With presetting

Standard. thermostatic valve body without presetting

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

INVERTER SPLIT - TYPE

Installation Instructions

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

Flush individual room control for floor heating systems

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Installation & Maintenance Data IM Contents

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

Installation Instructions

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

HEATING. COOLING. COMFORT. For a cosy home.

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

Dishwasher. Installation manual DW60M9990AP

Thermostatic valve bodies

Installation Instructions

Regulux. Radiator lockshield with drain-off facility. To be precise.

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

CEILING FAN OWNER S MANUAL

FIREPLACE INSTALLATION

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Air Conditioner. user installation & manual manual. imagine the possibilities

Moisture inside the drum is due to final testing.

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

INSTRUCTION MANUAL with Replacement Parts

Mounting and Operating Instructions EB 2231 EN

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Installation Instructions

Right-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Übersetzung. Installation instructions Page 10. Multi-temperature wine cabinet UWT 1672 / UWK 1752

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

SuperKlean Washdown Products

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Installation and maintenance instructions

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Packaged Coldroom. Installation Instructions. Operating instructions

INSTALLATION. Glass Panel Doors (select models) CAUTION

Closomat Lima Vita installation & user guide

INSTALLATION INSTRUCTIONS

DISTRIBUTION and CONTROL

Danfoss Air Heating Surfaces

MAINTENANCE MANUAL TAIYO SEIKI CO., LTD.

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

HE360 Humidifier Installation Kit

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Installation instructions

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

PAVIA INSTALLATION GUIDE

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

thermostatic valve body with stepless precision presetting

Moisture inside the drum is due to final testing. Mains cable. Water outlet

INSTALLATION INSTRUCTIONS

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Removing shipping locks

IMI Heimeier Kit Hydroca ble

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Thermotech underfloor heating

VERONA INSTALLATION GUIDE

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Model: 1100 Float-Controlled Condensate Trap, PN 25

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

2" and 2 1/2" Wood Horizontal Blinds 2", 2 1/4" and 2 1/2" Faux Wood Horizontal Blinds. Installation & Operating Instructions

BMW E36 Thermostat Removal And Coolant Flush

Owner s Guide and Installation Manual

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Transcription:

www.variotherm.at INDIVIDUAL HEATING Skirting Heating Classic. Skirting Heating Delta. Installation Delta HEATING. COOLING. COMFORT. Classic Installation Manual e22111

Page 2 Table of Contents INDIVIDUAL HEATING 1 Safety information... 3 1.1 Regulations... 3 1.2 Guarantee conditions... 3 1.3 Weather resistance of the pre-insulated Variomodular pipe 16x2/Alu0.25... 3 1.4 Heating elements... 3 2. Skirting heating types... 4 2.1 Skirting heating types with metal cladding - Delta skirting heating system... 4 2.2 Skirting heating types for wooden cladding (provided by the customer) - Classic skirting heating system... 4 2.3 Skirting heating types for wooden cladding (provided by the customer) - Skirting heating system Classic... 4 3. Pipes... 5 3.1 General... 5 3.2 Connection spacing from the wall... 5 3.3 Maximum skirting heating length per heating circuit... 5 3.4 Manifold system with the pre-insulated Variomodular pipe 16x2/Alu0.25... 6 3.5 2-pipe system e.g. with copper pipe... 7 4. Fitting the brackets... 8 4.1 Bracket components, designations... 8 4.2 Preparation... 8 4.3 Fastening the brackets... 8 5. Fitting the heating elements... 9 5.1 Inserting the heating elements... 9 5.2 Securing the heating elements... 9 6. Hydraulic connection of the heating elements... 10 6.1 Manifold system... 10 6.2 2-pipe system... 10 7. Cladding... 14 7.1 Delta cladding... 14 7.2 Classic cladding... 15 8. Leak-tightness test & commissioning... 16 9. Drilling templates for the brackets... 17

Installation manual 1 Safety information Page 3 1 Safety information 1.1 Regulations Observe the applicable local regulations and standards for electrical and heating installation. 1.2 Guarantee conditions If the heating system is installed or commissioned incorrectly, all claims on the basis of the manufacturer's warranty and guarantee become void. 1.3 Weather resistance of the pre-insulated Variomodular pipe 16x2/Alu0.25 The Variomodular pipe is only weather-resistant to a limited extent, and must be shielded from direct sunlight. The Variomodular pipe should not be stored outdoors. The interaction of the air's oxygen with UV rays damages the pipes. Normal temporary storage on the construction site for a few days is permissible. 1.4 Heating elements The heating elements are delivered packaged in boxes with a length of 2.5 m. They must be protected against damage or unintentional bending of the louvres. 2500 mm 40 mm 40 mm 56 mm 78 mm ø 18 mm 0,5 mm Copper pipe wall thickness Standard heating element 2500 mm 40 mm 40 mm 35 mm 78 mm ø 18 mm 0,5 mm Copper pipe wall thickness Mini heating element

Page 4 2. Skirting heating types INDIVIDUAL HEATING 2. Skirting heating types 2.1 Skirting heating types with metal cladding - Delta skirting heating system 65 mm 87 mm 87 mm 42 mm 1 mm 195 mm 195 mm 195 mm -40 mm 40-50 mm 40-50 mm 40-50 mm Delta skirting heating system mini Delta skirting heating system Ia Delta skirting heating system IIa Delta skirting heating system IIIa 2.2 Skirting heating types for wooden cladding (provided by the customer) - Classic skirting heating system a 44 mm a 65 mm a 88 mm a 88 mm b b b b c 1 mm c 200 mm c 200 mm c 200 mm s d s d s d s d Skirting heating system mini Classic Skirting heating system Ia Classic Skirting heating system IIa Classic Skirting heating system IIIa Classic a... 44 mm + s b... 25 mm c... 105 mm d... min. to max. 40 mm s... min. 15 mm (e.g. wooden multilayer board) a... 65 mm + s b... 37 mm c... 163 mm d... min. 40 to max. 50 mm s... min. 15 mm (e.g. wooden multilayer board) a... 88 mm + s b... 37 mm c... 163 mm d... min. 40 to max. 50 mm s... min. 15 mm (e.g. wooden multilayer board) a... 88 mm + s b... 37 mm c... 163 mm d... min. 40 to max. 50 mm s... min. 15 mm (e.g. wooden multilayer board) 2.3 Skirting heating types for wooden cladding (provided by the customer) - Skirting heating system Classic d If the shaft height changes (= lower edge of the heating element to the upper edge of the front cladding) an additional fastening must be provided to secure the cladding (provided by the customer). 120 mm 170 mm 170 mm 160 mm 200 mm 160 mm 200 mm 160 mm Schachthöhe Shaft height 200 mm d 40 mm 40 mm 40 mm Change in shaft height Skirting heating system IVa Classic with wooden brackets Skirting heating system Va Classic with wooden brackets Skirting heating system VIa Classic with wooden brackets

Installation manual 3. Pipes Page 5 3. Pipes 3.1 General Socket Skirting heating systems are installed in the manifold system with preinsulated Variomodular pipes or in the 2-pipe system with copper pipes, for example. When planning electric sockets, ensure that they are located above the skirting heating. 3.2 Connection spacing from the wall Skirting heating system mini Finished wall Skirting heating system Ia Finished wall Flow Length entered in the plan Reciprocal connection Return Flow Return 20 mm Length entered in the plan Reciprocal connection 31 mm Skirting heating system IIa Skirting heating system IIIa Finished wall Finished wall Flow Return Flow Return Length entered in the plan Reciprocal connection 42 mm -50 mm 42 mm Length entered in the plan Connection on one side To prevent damage to the heating elements and cladding, they should not be fitted to the painted walls until the flooring is completed. The supply pipes are installed in accordance with the connection spacing shown above. 3.3 Maximum skirting heating length per heating circuit Mini skirting heating, Ia and IIa: max. 7.5 m per heating circuit Skirting heating IIIa: max. 5.0 m per heating circuit Max. length 5.0 m Max. length 7.5 m e.g. Skirting heating system mini, manifold system e.g. Skirting heating system IIIa, 2-pipe system

10 10 20 40 C 0 20 40 C 0 60 60 50 50 Page 6 2. Skirting heating types INDIVIDUAL HEATING 3.4 Manifold system with the pre-insulated Variomodular pipe 16x2/Alu0.25 For installations with manifold systems, first lay the pre-insulated Variomodular pipes from the manifold to the skirting heating and back, and then connect them to the manifold via a screw fitting. There must not be any kinks in Variomodular pipes when laying them. The Variomodular pipe should be routed endlessly (i.e. without additional connection points) from the manifold to the skirting heating. The pipe is positioned near the skirting heating with the installation bracket. Electronic room thermostats and servomotors are used to control the room temperature. Pre-insulated Variomodular pipe 16 x 2/Alu 0.25 Kitchen Feed Hall e.g. PIANO H Anteroom RT Distribution manifold RT Living room WC Elbow union FFL Laying example with Variotherm distribution manifold Protective pipe Pre-insulated Variomodular pipe Installation bracket Inner flexible spring Elbow union mini Ia Pre-insulated Variomodular pipe 16 x 2/Alu 0.25 to manifold IIa Copper bend 5001A ø 18 & 5002A ø 18 IIIa

Installation manual 2. Skirting heating types Page 7 VERTEILEN und REGELN www.variotherm.at "DISTRIBUTION and CONTROL" Montage Planung 20 C Details regarding the system and heating circuit pipes and the room temperature control are provided in the "DISTRIBUTION and CONTROL" planning and installation manual. 40 10 50 60 0 20 C 40 10 50 0 60 Montageanleitung & Planungshandbuch 94311 3.5 2-pipe system e.g. with copper pipe Feed Cu ø 18 Hall Kitchen Cu ø 18 Anteroom Cu ø 18 Cu ø 22 Cu ø 18 WC Rising line From boiler house or boiler Cu ø 22 For installation in the 2-pipe system, flow valves with an integrated deaeration system are used to control the room temperature. The return valves are used to shut off and set the water quantity (hydraulic compensation) Living room Cu ø 18 Laying example with 2-pipe system Ia mini Return valve IIa Copper bend 5001A ø 18 & 5002A ø 18 IIIa Thermostat head

Page 8 4. Fitting the brackets INDIVIDUAL HEATING 4. Fitting the brackets 4.1 Bracket components, designations The brackets for the Classic and Delta skirting heating systems are identical. For the Classic skirting heating system, a mounting plate and a mounting base are supplied for each bracket, to allow the cladding provided by the customer to be attached to the bracket. 2 1 3d 3d 3b 3b 3 3a 4 3c 4 Components for Classic & Delta skirting heating systems (parts in red frame for Classic only) 5 6 7 7 1... Rounded head screws 5x45 mm (3x) 2... Dowels U8 (3x) 3... Bracket (1x) 3a... Catch 3b... Bearing (heating element) 3c... Spring 3d... Screw slot 4... Clip (mini, Ia: 1x; IIa + IIIa: 2x 5... Upper mounting base (1x) 6... Front mounting base (1x) 7... Countersunk head screws 3x16 mm (8x) 4.2 Preparation Mark using the bracket or drilling templates (see Chapter 9) approx. 750 mm 200 mm Determine the height of the bracket. *Distance from the finished floor to the lower edge of the bracket (= lower edge of cladding): mini: -40 mm Ia, IIa, IIIa: 40-50 mm * 750mm Make further markings approx. every 750 mm using a spirit level. Drill holes (if necessary) 4.3 Fastening the brackets Use spacers to smooth uneven parts of the wall. The upper and front edge of the 3. 2. 1. bracket should be aligned (test with bar). Screw the lower and one of the two upper screws into the positions marked previously, but not fully (allow space of approx. 5 mm). 4. Fit the bracket to the screws Fit the missing screw, align the bracket and fasten (tighten all screws).

Installation manual 5. Fitting the heating elements Page 9 5. Fitting the heating elements 5.1 Inserting the heating elements Lay the heating elements parallel to the wall...... and push the aluminium plates on the brackets to one side with an open-end wrench (size 21), for example. Insert the heating element The heating elements are cut to length according to the diagram using pipe cutters. Sections are soldered to one another or pressfit (use approval for the Viega Profipress system > support sleeves!) Ensure that the installation position of the heating element is correct in accordance with the prescribed types (see Chap. 3). 5.2 Securing the heating elements Secure the heating element using the clips. 1. 2. The clip of the respective type is pushed down at the points marked with an arrow, and then latched into position using the thumb. The clip can be removed easily using a multigrip pliers. mini Ia IIa+IIIa Clips for securing the skirting heating

www.variotherm.at Montage Planung 0 20 40 C 10 50 60 20 40 C 10 50 60 0 VERTEILEN und REGELN Montageanleitung & Planungshandbuch 94311 Page 10 6. Hydraulic connection of the heating elements INDIVIDUAL HEATING 6. Hydraulic connection of the heating elements 6.1 Manifold system Cutting to length, calibrating and bevelling the pre-insulated Variomodular pipe The Variotherm pipe cutting pliers is used to cut the pipe to length. Caution! The pipe must be cut at a right angle. Rotate the calibration tool into the pipe to the stop angle to calibrate and bevel the end of the pipe. Visually check that the face of the pipe is smooth, clean and free of Pipe cutting pliers 11.6/16 chips. Calibration and bevelling tool Feed to flow and return 6 5 3 4 2a 2b Push union nut (2b) loosely over the pre-insulated Variomodular pipe (1). Insert the support up to the stop while turning it slightly (do not hammer in). Insert the Variomodular pipe with the support into the union nut up to the stop, and tighten the screw fitting in this position. Push the assembled clamping screw fitting (5) loosely over the copper pipe. Insert the support sleeve (4) into the copper pipe. Important: Push the copper pipe into the bracket (3) until it stops and tighten the screw fitting in this position. 1 (1) Pre-insulated Variomodular pipe (2) 3/4 EUROx16 clamping screw fitting (3) 90 bracket 3/4 EURO (4) Support sleeve 18 x 17 mm (5) 3/4 EUROxCu18 clamping screw fitting (6) Heating element Support sleeve 18 x 17 mm Clamping screw fitting 3/4 EUROxCu18 Clamping screw fitting 3/4 EUROx16 Deaeration Deaeration is performed by flushing and the deaerators installed on the distribution manifold. "DISTRIBUTION and CONTROL" Details regarding the system and heating circuit pipes and the room temperature control are provided in the "DISTRIBUTION and CONTROL" planning and installation manual. 6.2 2-pipe system In the 2-pipe system, the skirting heating is piped in accordance with the laying diagram using copper pipes, for example. The flow valve is installed with integrated deaeration in the flow side and the return valve is installed in the return side.

Installation manual 6. Hydraulic connection of the heating elements Page 11 Soldering the copper piping Before soldering, prepare a cover to protect the floor and wall from flames. Clean the pipes and fittings at the solder contact points with a cleaning cloth and inner brush. Apply solder paste evenly to one part. Join the two contact points and solder them. It is important that the soldering point is kept clear of dirt particles such as masonry dust etc. Tip for piping: If necessary (old building with finished floors etc.), additional uninsulated pipes to max. 18 mm external diameter can also be held in the brackets. Typ Ia Typ IIa Typ IIIa Deaeration The individual skirting heating systems are deaerated via the flow valves with integrated manual deaeration systems. The deaeration elbow is inserted in the return for valves without integrated deaeration systems. Deaeration elbow Flow valve The flow valve with integrated deaeration is available in left, right or continuous versions. On delivery, there is a protective plastic cap on the valve spindle. This allows the valve to be opened or closed without a valve head. Before mounting the valve head or the handwheel, the protective plastic cap is removed. Duct Left corner Right corner Valve heads for flow valves Thermostat head Servomotor Handwheel Thermostat head with remote sensor Extension for thermostat head 20 mm, from a cladding thickness of 10 mm for IIa + IIIa Classic

Page 12 6. Hydraulic connection of the heating elements INDIVIDUAL HEATING Feed to flow 5 2 3 4 Push the assembled clamping screw fitting (2) loosely over the copper pipe, insert the support sleeve (4) into the copper pipe. Caution! The pipe must be cut at a right angle. Important: Push the copper pipe into the valve until it stops and tighten the screw fitting in this position. 2 Cu15/18 (1) e.g Cu pipe ø 18 mm (2) 3/4 EUROxCu18 clamping screw fitting (3) Left corner flow valve (4) Support sleeve 18 x 17 mm (5) Heating element 1 Support sleeve 18 x 17 mm Clamping screw fitting 3/4 EUROxCu18 Flow valve characteristic curve DN DN 15 15 (1/2 ), ( 1 /2"), cv kv-wert value 0,49 0,49 (applies (gilt für to Thermostatkopf) thermostatic head) 0 00 20 200 2000 10 100 1000 Sample calculation 1 5 50 500 3 0 2 20 200 1 10 100 Pressure Druckverlust loss p p [kpa] [kpa] 0,5 5 0,3 3 0,2 2 0,1 1 10 20 50 100 200 0 500 1000 2000 Massenstrom flow m [kg/h] m [kg/h] Pressure Druckverlust loss p p [mbar] [mbar] 50 20 10 Pressure Druckverlust loss p p [mmwc] [mmws] Regeldifferenz xp Control difference xp 2 K Sample calculation 1: Required: Pressure loss for 1/2 at 2 K control difference Given: Heat flow Q = 1450 W, Temperature spread t = 10 K (55/45 C) Solution: Mass flow m = Q/(c t) = 1450/(1.163 10) = 125 kg/h Pressure loss from diagram p = 65 mbar / 650 mmwc (0.65 mwc) / 6500 Pa

Installation manual 6. Hydraulic connection of the heating elements Page 13 Return valve The return valve is used for hydraulic compensation and as a shut-off valve if the heating elements have to be dismantled (e.g. for painting). The valve spindle is under the protective cap. The return valve can be closed by rotating it. Duct Corner Feed to return 5 2 3 4 2 Cu15/18 (1) e.g Cu pipe ø 18 mm (2) 3/4 EUROxCu18 clamping screw fitting (3) Corner return valve (4) Support sleeve 18 x 17 mm (5) Heating element 1 Push the assembled clamping screw fitting (2) loosely over the copper pipe, insert the support sleeve (4) into the copper pipe. Caution! The pipe must be cut at a right angle. Important: Push the copper pipe into the valve until it stops and tighten the screw fitting in this position. Support sleeve 18 x 17 mm Clamping screw fitting 3/4 EUROxCu18 Return valve characteristic curve 60 50 Einstell-Umdrehungen Configuration rotations [U] [U] 0,25 0,75 0,5 1,75 1,5 1,25 1 2 2,5 3 3,5 max. Max. delivery condition open 600 500 6000 5000 0 00 20 200 2000 10 100 1000 5 50 500 3 2 20 0 200 Sample calculation 2 Pressure Druckverlust loss p [kpa] 1 0,5 10 5 0,3 3 0,2 2 0,1 1 2 3 5 10 20 0 50 100 200 0 500 1000 2000 Pressure Druckverlust loss p [mbar] 100 50 20 10 Pressure Druckverlust loss p [mmwc] [mmws] Massenstrom flow m [kg/h] m [kg/h] Sample calculation 2: Required: Valve opening (rotations) at a pressure loss via the return valve of p = mbar (0. mwc, 00 Pa) Given: Heat flow Q = 1450 W, Temperature spread t = 10 K (55/45 C) Solution: Mass flow m = 1450/(1.163 10) = 125 kg/h > Open the return valve 1.25 rotations.

Page 14 7. Cladding INDIVIDUAL HEATING 7. Cladding If the required skirting heating cladding is not mounted immediately, protect the mounted heating elements using their packaging boxes, for example (cut slits in the box, pass the bracket catches through). This effectively protects the heating elements from damage. 7.1 Delta cladding 2. 1. Fit the Delta at the bottom near the tension spring and click it into place at the top. Delta cladding which has been clicked into place. If uneven walls cause problems when snapping the upper edge into place, loosen the upper bracket screws. After locking the cladding into place, the screws can then be tightened again through the upper front hot air slit opening. 2. 1. To remove the cladding, first pull it out at the bottom and lift it out upwards. Connections The connecting elements are clipped in, inner corners, outer corners and the end caps on the left and right are fastened subsequently using the enclosed screws to the front cladding (do not forget to drill). Inside corner 90 Outside corner 90 Connecting elements End cap left End cap right The formed parts are attached with the supplied screws. Use the Variotherm paint pen to paint the screw heads after mounting. Round hole punch For the flow valves, punch a hole into the Delta cladding in the axis of the valve head using the appropriate round hole punch. The thermostat head will later protrude through this hole. Hole diameter required: ø 40 mm for mini skirting heating system, ø 55 mm for Ia, IIa + IIIa, and valves with servomotors Example: Delta mini skirting heating system

Installation manual 7. Cladding Page 15 7.2 Classic cladding *... Comply with spacing per Page 5 Schachthöhe Shaft height d* Schachthöhe Shaft height d* Please note the dimensions of the cladding on page 5. If the wooden skirting is mounted further from the floor (e.g. due to wall-mounted pipes), you must still comply with the air vent spacing (extend cladding further down) For cladding of the Classic skirting heating provided by the customer, each bracket includes a mounting plate and mounting base with fastening screws (see also Chap. 5.1). Virtually any wood is suitable as wooden cladding. It should be torsion free and dry (e.g. 3-layer board). Push the mounting base into the bracket...... and transfer the outline to the upper cladding. Screw the mounting base onto the upper cladding. 1. 2. The upper cladding can now be pushed into place. For the front cladding, the mounting plate is secured after adaptation to the brackets Attach the front cladding to the bottom spring and click it into the catch. Simple mounting brackets are used for end connections. Drill a hole in the cladding in the axis of the valve head for the flow valves.

Page 16 8. Leak-tightness test & commissioning INDIVIDUAL HEATING 8. Leak-tightness test & commissioning Construction project: Building owner/ Occupant: Client: Heating installation technician: Architect: Other: Leak-tightness test The Variotherm skirting heating system circuits are to be tested for leak-tightness using a water pressure test after they have been laid. The test pressure should be twice the operating pressure (at least 6 bar). If there is a risk of freezing, appropriate measures should be taken, e.g. use of antifreeze and controlling the building s temperature. > Skirting heating incl. cladding, connection and piping completed on: > Pressure test started on: > Pressure test finished on: > The system water was treated (e.g. per ÖNORM H5195-1) Yes No > Antifreeze was added to the system water Yes No > Heating started on: Approval: Building owner/occupant/client Construction management/architect Heating installation technician Commissioning The flow and return valves or the heating circuit shut-offs on the manifold must be opened. The entire system is to be deaerated thoroughly. The circulation pump may be switched on after deaeration. After commissioning, the Variotherm skirting heating system can be considered maintenance-free. (Subject to technical modifications without notice.)

Installation manual 9. Drilling templates for the brackets Page 17 9. Drilling templates for the brackets 28 17,5 mini 115 FFL min. max. 40 FFL

Page 18 8. Leak-tightness test & commissioning INDIVIDUAL HEATING 28 min. 40 max. 50 124 25 Ia FFL FFL

Installation manual 8. Leak-tightness test & commissioning Page 19 28 min. 40 max. 50 1 25 IIa + IIIa FFL FFL

HEATING. COOLING. COMFORT. Variotherm has been developing, producing and selling innovative, ecological and economical heating and cooling systems since 1979. Your Variotherm partner VARIOTHERM HEIZSYSTEME GMBH GÜNSELSDORFER STRASSE 3A 2544 LEOBERSDORF AUSTRIA Phone: +43 [0] 22 56-648 70-0 Fax: +43 [0] 22 56-648 70-9 office@variotherm.at www.variotherm.at All rights pertaining to distribution and translation, in whole or in part, including film, radio, television, video recording, Internet, photocopying and reprinting, are reserved.