DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

Similar documents
MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Model 100 Duct Mount Kit

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

Vibratone Horns. Models 350 and 450

The Signal Is Clear TM

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Hazardous Location Supervised Warning Light

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL

SELECT-A-HORN/STROBE SERIES

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Explosion Proof Line Powered Telephone Ringer

SIMPLEX WEATHERPROOF CONTROL PANELS

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

GAS MONITOR Model Model

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Series M22 Signaling Beacons and Alarms

MODELS 304GC, 304GCX, 314GC, and 314GCX

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

TrueAlert Addressable Notification Appliances

ELP21LU3-LF-HLOL THREE CHANNEL

MODELS ASHP, ASHH, ASUP, and ASUH

Informer100 Speaker Models I-IP100AC and I-IP100DC

INSTALLATION AND INSTRUCTION MANUAL

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

TrueAlert Multi-Candela Notification Appliances

Static Pressure Alarm For Hazardous Location Fume Hoods

TrueAlert Addressable Notification Appliances

THUNDER LOW FREQUENCY AMPLIFIER INSTALLATION MANUAL

Vibratone Horns. Models 350 and 450

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

DC Microstrobes AC Microstrobes

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Centro-Matic Automated Lubrication Systems System Controls

Street Thunder ST240 SIREN AMPLIFIER INSTALLATION AND OPERATING INSTRUCTIONS

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Global Water Instrumentation, Inc.

Hazardous Area Ringdown Telephone

TOLL FREE PHONE FAX

Hot Products. Heavy Industrial Intercom Sytems. XLT Technology (extreme Light Technology) Federal Signal Introduces Hazardous Location with 27XL 225XL

Model 9001, Alarm

Eclipse 8 & Eclipse NH

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

PRM-100 INSTALLATION MANUAL OUTDOOR PARAPET ROOF MOUNT WITH ELL CONDUIT BOX MANUAL NUMBER

s Notification Appliances

Alarm Tone Generator Model AG17

Certificate of Compliance

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Hazardous Area Ringers & Loudspeakers

INSTRUCTION MANUAL (ATEX / IECEx)

Model TL104 MANTL104. Test Lamp for Flame Detection

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

Certificate of Compliance

DWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.1 December 2014

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Model 400 Series Lights Installation Instructions

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Hazardous Area Telephone Model EP600

TrueAlert Multi-Candela Notification Appliances

Model 9001, Alarm

DWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.0 August 2014

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

ELECTRONIC BELL (A80301)

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

Oxygen (O2) Single-Point Gas Detection System

Figure 1. Figure 2. See notes 1 and 2 below.

About Tomar Audible Alarms 1000 & 1100 Power Alarm WEP Explosion Proof Power Alarm Siren

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

OPERATING AND INSTALLATION

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

Process Protection. MFA 4P Motion Failure Alarm

Colibri. Automatic Tank Gauge CL6 Series Installation Guide

Pilot devices Stacklights Signal beacons

Addressable Fire Alarm Control Panel

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

380 SERIES REMOTE SIREN ETSA380R

Potter Wall Mount Select-A-Strobe

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Transcription:

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station Operator s Installation and Instruction Manual DETCON, Inc. 3200 Research Forest Dr, The Woodlands, Texas 77387 Ph.281.367.4100 / Fax 281.298.2868 www.detcon.com November 6, 2009 Document #3080 Revision 2.1

AV1/AV2-C1D2M This page left intentionally blank AV1/AV2-C1D2M Instruction Manual ii

AV1/AV2-C1D2M Table of Contents 1.0 Description... 1 1.1 Strobe... 1 1.2 Siren... 2 2.0 Installation... 3 3.0 Parts List... 7 4.0 Warranty... 7 5.0 Appendix... 8 5.1 Revision Log... 8 Table of Figures Figure 1 Strobe... 1 Figure 2 SSTX-MV Siren... 2 Figure 3 SSTX-MV printed circuit board... 3 Figure 4 AV1-C1D2M Dimensional... 4 Figure 5 AV2-C1D2M Dimensional... 5 Figure 6 120/240VAC wiring diagram... 6 Figure 7 24 VDC Wiring... 6 AV1/AV2-C1D2M Instruction Manual iii

AV1/AV2-C1D2M This page left intentionally blank This page left intentionally blank AV1/AV2-C1D2M Instruction Manual Shipping Address: 3200 A-1 Research Forest Dr., The Woodlands Texas 77381 Mailing Address: P.O. Box 8067, The Woodlands Texas 77387-8067 Phone: 888.367.4286, 281.367.4100 Fax: 281.292.2860 www.detcon.com sales@detcon.com iv

1.0 Description AV1/AV2-C1D2M Detcon Model AV2-C1D2M audiovisual alarm stations are designed for installation and use in hazardous duty, corrosive work environments. The Strobes are UL listed and CSA Certified for Class I, Division 2, Groups A, B, C and D; Class II, Division I, Groups E, F, and G; and Class III. The siren is UL listed for Class I, Groups B, C and D; Class II, Groups E, F, and G. The AV1-C1D2M alarm station consists of one strobe light and a siren. The AV2-C1D2M alarm station consists of two strobe lights and a siren. The station can be wired to control circuit alarm devices for the purpose of warning personnel of hazardous conditions. When used in conjunction with Detcon controllers, the alarm station is typically used to provide a low alarm (strobe) and high alarm (strobe/horn) for pre-determined hazardous environmental gas levels (toxic or flammable) as indicated by remote mount sensors. 1.1 Strobe The alarm station strobe lights are configured with any combination of dome colors such as amber, blue, clear, green, magenta, or red. Dome guards are included. The rugged warning light is specifically designed for hazardous locations or corrosive environments where a very bright visual signal is required. Hazardous location strobes are available in voltage ratings of 120VAC or 240VAC. The strobe light provides 80 high-intensity flashes per minute. UL listed and CSA certified for Class I, Division 2, Groups A, B, C and D; Class II, Division I, Groups E, F, and G; and Class III. The light meets Type 4X watertight, dust-tight, and corrosion resistant requirements; constructed to IP66. It has an aluminum base coated for corrosion-resistance. The dome guard fits over the plastic dome to protect it against accidental collision with moving equipment. Figure 1 Strobe Specification Voltage Mount Operating Current Dome Colors Dome Guard Operating Temperature Minimum 12-24VDC, 120VAC 50/60HZ, 240VAC 50/60HZ ¾ Pipe 0.60 Amps at 24VDC; 0.32 Amps at 120VAC, 0.16 Amps at 240VAC Amber / Blue / Clear / Green / Magenta / Red Included -31 F AV1/AV2-C1D2M Instruction Manual Rev.2.1 Page 1 of 8

Operating Temperature Maximum 150 F Flash Rate/Minute 80 Effective Candle Power 165 Enclosure Rating Type 4X, IP66 Height 8.75in Diameter 5.5in. AV1/AV2-C1D2M 1.2 Siren Figure 2 SSTX-MV Siren The alarm station Explosion Proof Power Alarm siren is a rain-tight solid-state audible alarm that features four field selectable sounds: Wail, Yelp, Horn, and Temporal Slow Whoop. The siren is weatherproof constructed with a cast aluminum housing and spun Aluminum horn. It produces a noise level of a 98dbA @ 10 feet in a wide angle sound dispersion pattern. The explosion proof power alarm siren is available in voltage ratings of 24VDC, 120VAC or 240VAC @ 50/60Hz. and mounts on a unidirectional mounting bracket with ½ conduit access. UL listed for Class I, Groups B, C and D Specifications Voltage 24VDC, 120 VAC 50/60 HZ, 240 VAC 50/60 HZ Mount Omni Directional Mounting Bracket Operating Current 0.6Amps at 24 VDC 0.21Amps at120 VAC 0.12Amps at 240 VAC Temperature Rating -35 C to +72 C; -31 F to +161 F Sound Output DB (A) @ 10 on Axis Wail 108 Yelp Horn 108 102 Temporal Slow Whoop 102 Enclosure Rating Type3R, IP44 AV1/AV2-C1D2M Instruction Manual Rev. 2.1 Page 2 of 8

Height 14.75in. Width 8.88in. Long 14.75in Sound Selectable Positions Listed in Figure 3 AV1/AV2-C1D2M Figure 3 SSTX-MV printed circuit board 2.0 Installation The assembly is mounted on a T-shaped Aluminum bracket with holes pre-drilled to accommodate (2) U-bolt attachments on a 2.5 maximum diameter pipe. U-bolt size is 3/8-16 x 3 inches. Overall Dimensions are 33 H x 16.5 W x 18.5 D (Figure 4). The tone for the siren is set using tone selector jumpers, J4 & J5. Each jumper consists of three pins and the selection of appropriate tone is made by placing a jumper on two of the three pins as shown in Figure 3. The alarm comes pre-wired for the voltage ordered from the factory (110/220VAC or 24VDC). Wiring is installed through the opening at bottom of junction box. Connect wiring in accordance with the appropriate wiring diagram (Figure 6 or Figure 7), AV1-C1D2M being wired for Strobe 1 only. Use only 12 to 18 AWG wire for power connections. Strip no more than 0.25-inch of insulation from the ends of the power leads. AV1/AV2-C1D2M Instruction Manual Rev. 2.1 Page 3 of 8

AV1/AV2-C1D2M Ground can be connected either to the Condulet Ground Screw or to the Plug on the terminal board. Optionally, each annunciator can be powered independently by removing the jumper between terminal points 5, 6, and 7, and wiring directly to the return path of the annunciator. 16.5" 33" 16" 8.3" 3.4" 5.5" Figure 4 AV1-C1D2M Dimensional AV1/AV2-C1D2M Instruction Manual Rev. 2.1 Page 4 of 8

AV1/AV2-C1D2M 16.5" 33" 16" 8.3" 3.4" 5.5" Figure 5 AV2-C1D2M Dimensional AV1/AV2-C1D2M Instruction Manual Rev. 2.1 Page 5 of 8

AV1/AV2-C1D2M STROBE 1 SIREN STROBE 2 STROBE 1 SIREN STROBE 2 L1 L2 G L1 L2 G L1 L2 G L1 L2 G L1 L2 G L1 L2 G Standard wiring shown on left. Optional: Removal of jumper between 5,6, and 7 for discrete annunciator wiring shown on right. Ground can be connected to the Ground Screw or the connector. Note: Strobe 2 not present on AV!-C1D2C assembly L1 Strobe 1 L1 Strobe 2 L1 Siren L2 (Neu) GND Customer Input Wiring L1 Strobe 1 L1 Strobe 2 L1 Siren L2 Strobe 1 L2 Strobe 2 L2 Siren GND Optional Customer Input Wiring Figure 6 120/240VAC wiring diagram STROBE 1 SIREN STROBE 2 STROBE 1 SIREN STROBE 2 L1 L2 G L1 L2 G L1 L2 G L1 L2 G L1 L2 G L1 L2 G Standard wiring shown on left. Optional: Removal of jumper between 5,6, and 7 for discrete annunciator wiring shown on right. Ground can be connected to the Ground Screw or the connector. Note: Strobe 2 not present on AV!-C1D2C assembly L1 Strobe 1 L1 Strobe 2 L1 Siren L2 (Neu) GND Customer Input Wiring L1 Strobe 1 L1 Strobe 2 L1 Siren L2 Strobe 1 L2 Strobe 2 L2 Siren GND Optional Customer Input Wiring Figure 7 24 VDC Wiring AV1/AV2-C1D2M Instruction Manual Rev. 2.1 Page 6 of 8

3.0 Parts List AV1/AV2-C1D2M Detcon Part # Description 500-003198-000 Alarm System Terminal Board 356-889321-MV0 24 VDC / 120VAC / 240VAC Hazardous Location Siren 354-1516X6-024 151XST 24VDC Strobe, Ext Ground (X represents color of lamp) 354-1516X6-120 151XST 120VAC Strobe, Ext Ground (X represents color of lamp) 354-1516X6-240 151XST 240VAC Strobe, Ext Ground (X represents color of lamp) Strobe colors: Red (2), Amber (4), Green (5), Blue (6), Magenta (7), and Clear (9) 4.0 Warranty Detcon Inc., as manufacturer, warrants under intended normal use each new AV1/AV2-C1D2M Alarm station to be free from defects in material and workmanship for a period of one year. The warranty period begins from the date of shipment to the original purchaser and ends one year thereafter. All warranties and service policies are FOB the Detcon Inc. facility located in The Woodlands, Texas. AV1/AV2-C1D2M Instruction Manual Rev. 2.1 Page 7 of 8

5.0 Appendix AV1/AV2-C1D2M 5.1 Revision Log Revision Date Changes made 1.2 March 6, 2006 Using Tomar WEP1002 siren 1.4 September 7, 2007 Changed to Federal Signal SSTX-MV siren, addition of spare parts for the Siren 2.0 May 20, 2008 Modified wiring drawings to show common return and individual activation of siren(s) and horn. Removed Federal Signal spare parts 2.1 November 6, 2009 Change to title of AV1/AV2-C1D2M, addition of picture and drawings relating to AV1-C1D2M alarm station, addition of Revision log Shipping Address: 3200 A-1 Research Forest Dr., The Woodlands Texas 77381 Mailing Address: P.O. Box 8067, The Woodlands Texas 77387-8067 Phone: 888.367.4286, 281.367.4100 Fax: 281.292.2860 www.detcon.com sales@detcon.com AV1/AV2-C1D2M Instruction Manual Rev. 2.1 Page 8 of 8