Asda. refrigeration unit using the supplied adhesive pad. Then securely Connection box in the same area (examples below).

Similar documents
IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

600 Range Dialer Installation Manual. Version 1.0

TWLC - Tempered Water Logic Controller. The Intelligent Control

The future of security, secured IP by security professionals, for the professional security industry

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

FIRERAY 5000 range USER GUIDE

IP & SMS Alarm Communicator

Memcom Emergency Telephone

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

T4000 Security Communicator

U ser's Guide PC6010

GLOBAL. InstallatIon & operation manual

MVE TS Controller (Touch Screen)

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Product Data Sheet. Remote Terminals. Features:

Advisor Advanced Mobile Application User Manual

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

Gas Cooler. Advanced Controller. Flash Tank. Variable Frequency Drive. Multi-stage Compressor

21-light Remote Annunciator. Owner s Manual

Products no longer available

EUROSCAN RX2-6 / TX2-6

Oakton TEMP 9500 Advanced Multiparameter Controller

Remote Service App. Client Installation and Operation Guide V1.1

AVPTC. Air Handler 1½ to 5 Tons

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.

T500 Elite MANUAL (Software Version 3.0.9)

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

HRX Technical Manual. Version 1.2

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Code Alert Series 30 Software User Guide

SC-F3G User Manual 1.0

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

TR/TS40, TR/TS16, TR/TS60 Thermostat

Dryer Controller M720

Patriot Systems Limited

Dryer Master Inc. Dryer Master AM 3. Product Manual

it500 Internet Thermostat INSTALLER MANUAL

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

User Manual. Dryer Controller M720

Planning Elevator Relay Groups Programming Millenium for Windows Software

Security designed for your lifestyle

Entero Voice Alarm system.

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

BAT LTE SKU: IPD-BAT-LTE

Follett Performance Plus

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2

Patriot Systems Limited

Ion Gateway Cellular Gateway and Wireless Sensors

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

Operators Manual. E15 Seeder Console Air Seeder Monitor A600 R1.3 V2.0.18

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

DAF SPOT Trace User Guide

CODE ALERT Enterprise Software User Guide

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Two-Channel Gas Controller

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Dust Alert 75. *shown with optional external keypad and display

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

AVPTC Multi-Position, Internal Txv

Network VP Sensor Input Kit (SIK) Installation Instructions

Memcom + Emergency Telephone

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

REMOTE CONTROL FOR CHILLER MYCHILLER

Instruction Guide: Thermostat Operation

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

PRO Installation. Touch Wi-Fi Thermostat

PERMACONN PM1030 Includes DI300. Installation Manual

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

BAT WIFI SKU: IPD-BAT--WIFI

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

Dryer Master DM510 Commissioning Guide

Communicator. User & Installation Manual

Wireless Controls System Guide

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Genesis DM Installation Readiness

ACT2-CS Convenience Store Controller

Welcome to Unilux VFC Wall-mount Thermostat

1.1 Ethernet Remote Annunciator Controller (RAC) using the up to 4 ATC-300+ connected via RS-485 to TCP/IP gateway

EXPERT TRI-STAR. Temperature controller. User s Manual

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

TRAULSEN RBC50, RBC100 & RBC200 BLAST CHILLERS

Owner s Manual ENERGY EFFICIENT, AT A TOUCH OF A BUTTON TSTPRH01, CÔRR 7 TSTWRH01 CÔRR 7C RESIDENTIAL THERMOSTATS. Côrr 7 Series

PRO Installation. Touch Wi-Fi Thermostat

AIRBORNE IRIS-4. Series. Installation and. Hurtigmanual/

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Avigilon Control Center System Integration Guide

ATC32U03 igate Communicating, Programmable Thermostat

ATC32U01 igate Communicating, Programmable Thermostat

Transcription:

Carrier Foretrack V100 Installation Guidelines DC500T - V2.6 Asda 1. Install DataCOLD 500T with unit Microprocessor Communicationn as per Installation Instruction 62-61139-00. 2. Mount the Carrier Foretrack V100 GPRS tracking device as shown below. 3. Fit the GPRS antenna in the highest most convenient location at the top of the refrigeration unit using the supplied adhesive pad. Then securely fit the Connection box in the same area (examples below). 4. Securely screw together the brass connections inside the box following the correct colour coding (do not over tighten) and fit the box lid using the screws supplied ensuring that the seal is correctly located. Route and secure antenna harness through the refrigeration unit to the enclosure. Carrier Foretrack V100 Installation Guidelines DC500T - V2.6 Asda Page 1 of 4

5. Using the grommet supplied route the GPRS antenna connections through in to the DataCOLD 500T recorder using one of the existing grommet holes. If all existing grommet holes are used re-route two probe cables in to one. 6. Connect the Carrier Foretrack V100 data cable & antenna as shown below: DC 500 TX1 RX1 GRD CABLE RED ORANGE BROWN IMPORTANT: DO NOT connect the power supply to the Carrier Foretrack V100 tracking device at this stage. 7. Specific for Asda Due to existing remote control panel connections to the COM port the DataCOLD 500T unit communication cable is to be connected to the SAT COM port, this is harness connected to the 5 way Deutsch connector. Remove the connector and connect the wiring as shown below: X 5 Way SAT COM Harness 3MP27 SATCOM A 3MP15 SATCOM B DC 500 TX2 RX2 3MP03 SATCOM C GRD In addition please ensure that micro configuration SATCOM is set to Other as per Service Bulletin AFS 52.04 PROD. Carrier Foretrack V100 Installation Guidelines DC500T - V2.6 Asda Page 2 of 4

8. Ensure the DataCOLD 500T has software version v2.17 or higher. This is done by pressing the Green button once and scrolling to menu 3.11 Display Version. Upgrade if necessary. 9. Set up the DataCOLD 500T GPRS communication by pressing and holding the Green button until prompted to enter a password. Using the Blue button on the keypad enter 1111 and scroll to Menu 11 Communication Settings. 10. In Menu 11.1 Com Port 1 Setting, select Third Party. 11. In Menu 11.2 Com Port 2 Setting, select relevant unit type as below: TM = Supra, Maxima Mono, TM800 & TM1000 R/TR = Genesis, Supra MT & Maxima MT Vector = Vector & Vector MT In Menu 11.2.1 Auto Alarm Limits, select YES (this is where we use the 'out of range' from the refrigeration unit). In Menu 11.2.1 Automatic Alarm On, select YES (this is so thatt the alarm menus become active once the refrigeration unit is switched on, it also prevents the operator switching them off). 12. Scroll to Menu 7 Compartment Settings, and select number of compartments depending on unit type e.g. 1, 2 or 3. Assign the relevant sensors to the selected compartments remembering to select NO when asked Alarm on Txx?. Alarms are covered in Menu 11.2.1. 13. Scroll to Menu 8 Temperature Alarm Settings. This should be set up as follows: Alarm Group 1 = ON (this is automatically switched ON when you select 11.2.1 Auto. Alarm Limits YES) All other Alarm Groups = OFF Note: Failure to follow the steps in sections 10, 11, 12 & 13 correctly will affect the communication links between the refrigeration unit, Datacold 500 & GPRS tracking device. Please ensure the steps carried out in sections 10, 11, 12, & 13 are checked and confirmed before proceeding. Carrier Foretrack V100 Installation Guidelines DC500T - V2.6 Asda Page 3 of 4

14. If a Door Switch is connected to the Datacold 500 due to system integration between Foretrack & Isotrak this must be installed on digital input D1 only 15. Switch on the refrigeration unit and allow it to start. 16. Connect the power supply cable for the V100 tracking device to the same power supply connections on the DataCOLD 500T recorder. Once connected ensure the two LED s light up and begin to flash (see chart below). LED Indicators GPS Status (green): GSM Status (red): Constant ON Flash (1Hz) Constant OFF Constant ON Slow flash (0.5Hz) Quick flash (1Hz) Constant OFF Searching for initial fix GPS 3D navigation Lost GPS signal GSM ON, searching for network GSM registered on network GSM communicationn in progress GSM Modem OFF 17. Check operation of the DataCOLD 500T including unit communication by pressing the RED statuss button. Check that there is a valid Setpoint shown in the display (If none present check all connections and Micro configurations before proceeding further). Note: In the communication process the arrow will appear on the display, during this time the keypad will be temporarily locked. NB: The settings in this procedure relate specifically to the Carrier Foretrack option and are over and above the standard DataCOLD 500R setup. E.g. Vehicle Reg, Customer name etc. 18. In the event of any installation problems please contact Carrier Transicold Service Engineering on 01925 401200. Carrier Foretrack V100 Installation Guidelines DC500T - V2.6 Asda Page 4 of 4

Carrier Foretrack Installation Registration (Datacold) V2.3 This form is to be completed on installation, once complete please call Carrierr Transicold on 01925 401200 to confirm details and validate the installation. Customer Device IMEI No Vehicle ID Refrigeration Unit Type Refrigeration Unit Serial No No Compartments No Probes Back Door Switch Installed (Digital Input D1 Only) Side Door Switch Installed (Digital Input D2 Only) Installing Dealer Carrier Foretrack Installation Registration (Datacold) - V2.22 Page 1 of 1 05/04/2013