FLUEBOOST. flueboost 350 gas fire model

Similar documents
100 FLUEBOOST

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon T-series Window & Roof Models

Lo-Carbon Quadra Centrifugal Fan

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Centrif Duo & Centrif Duo Plus

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Lo-Carbon Quadra SELV

Lo-Carbon SELV Tempra

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

HR200WK Through the wall Heat Recovery Ventilator

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

SUPER T WALL FANS. Installation and Wiring Instructions

Installation and Wiring Instructions

WHHR Midi & Midi Lite

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

Lo-Carbon Quadra Centrifugal Fan

Optimax Refrigerated Retail Merchandisers

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Silhouette Installation and Wiring Instructions

XB-EFA-8L-BK & XB-EFA-8R-BK

Optimax Refrigerated Retail Merchandisers

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

18 INCH HIGH VELOCITY FLOOR FAN

KADO LUX LED EXHAUST FAN 200

Model No: Little Devil II (inc ss)

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

BENSON LINEAR RADIANT TUBE

EZT90BL Extractor. Installation, Use and Maintenance.

24 & 30 INCH DRUM FANS

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

identity installation & maintenance instructions customer/technical services guarantee

Installation & User Instructions:

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

EVP61/91/101/121. Extractor. Installation, use and maintenance.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

EZA60BL & EZA90BL Extractors

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Drying Cabinet With Timer

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

HOTLINE:

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

EVG Extractors. Manual for Installation, Use and Maintenance

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

HEAVY DUTY RANGE BAIN MARIES & HOTCUPBOARDS (ELECTRIC)

Mobile Air Conditioner Instruction Manual Model TC-N9KM

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Purge Ventilation Unit. Product Manual. ventilation systems TP625

breeze easytm model # F100-1W

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

INSTALLATION & USER INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

PLATE DISPENSER MODEL NUMBERS MPN10000 MPN10500 MPN20000 MPN20500

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

HIT Centrifugal In-Line Fan

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INSTALLATION & USER INSTRUCTIONS

ECOLEC PANEL HEATERS GENERAL NOTES.

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

USER MANUAL. Adventure Kings 50L Refrigerator

Instruction Manual JLCHDD601/JLCHDD901 60cm/90cm Cooker hood

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

CARIBBEAN REFRIGERATED TOPPERS

OWNER S MANUAL CARTER FIREPLACE. Product code: UPC code: Date of purchase: / /


MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS

EDD61 & EDD91 Extractors

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Sunleaves Air Conditioner

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Transcription:

350 FLUEBOOST flueboost 350 gas fire model The flueboost is a box shaped unit with in line spigots for the flue connection, a pressure switch to ensure safe operation and plug-in electrical fittings for easy connection, all within a compact package. H E L P L I N E 01565 755599

350 FLUEBOOST 350 Flueboost Installation and Technical Specification GAS FIRE MODEL FAN MUST BE 1 METRE AWAY FROM FIRE PLACE OPENING FAN MIN 0.5 1METRE AWAY FROM TERMINAL MIN 300mm REQUIRED AWAY FROM ANY BEND LOCAL ISOLATION BY FAN FLUEBOOST CONTROL CAN BE FITTED HORIZONTALLY OR VERTICALLY ADVANTAGES OF AN INLINE FAN The ideal solution for listed buildings No need for scaffolding/cherry picker to install or for service/repairs Easy to maintain Acoustic surround available to reduce noise levels Can be located in loft/roof void/chimney stack so not an eyesore Not open to the elements giving a longer lifespan CAPACITY AND RANGES It will handle flue gases at up to 300 Deg.C dependant on size and length of flue. The fan is suitable for fireplaces with a maximum constructional opening of 0.5m². Ideally the flue gas velocity should be between 2.5 4 m/s. Please contact Flueboost prior to purchase to confirm the recommended duct diameter most suitable for the installation. MOTOR The motor is variable speed and has an centrifugal rotor with secondary cooling impeller, Class F windings and maintenance free sealed ball bearings with adequate lubrication to ensure reliable operation for many years. CONNECTIONS A plug-in electrical connector is supplied. This is multi-pin fitted with a six core number coded lead. Cable No.1: Grey N/O Cable No.2: Black N/C Cable No.3: Red Common Cable No.4: Brown Motor Live Cable No.5: Blue Neutral Earth: Green/Yellow PRESSURE SWITCH The unit features an approved fail-safe function (Gas Appliance Directive 2009/142/EC) which will cut off the gas supply in the event of fan failure or flue blockage. INSTALLATION AND MAINTENANCE The unit can be fitted horizontally or vertically and located in a ceiling or roof void which allows easy access for maintenance. FINISH The unit is constructed from mill finish grade 304 stainless steel. ELECTRICAL DETAILS 230 Volt; Single Phase; 115watt. Starting current 1.0 Amp. Running current 0.44 Amp. WEIGHT 11.6 Kg. 700mm REMOTE SWITCH SMG 700mm MAX FIRE OPENING SIZE MAINS GAS MAIN Note: Please contact Flueboost if the unit is being installed with a sealed appliance. F L U E B O O S T H E L P L I N E 01565 755599 April 2014

Model: FB350 Gas Fire Fan Original Document H E L P L I N E 01565 755599

Model: FB350 Gas Fire Fan DESCRIPTION The flueboost is a box shaped centrifugal fan unit within inline spigots for the flue connection, a pressure switch to ensure safe operation, and plug-in electrical fittings for easy connection all within a compact package. FLUEBOOST 350 GAS FIRE UNIT SPECIFICATION Maximum operating temperature Flue gas temperature 300 Deg C Ambient air temperature 40 Deg C Electrical details Supply 230V / 1Ph / 50Hz Supply lead 2 metre x 0.75mm, type YY x 6 core flex FAN MOTOR 115 watt Starting current 1 Amp Running current 0.44 Amp Motor speed 2600 R.P.M. Flue spigot details 197 mm O.D. Construction Case 304 grade stainless steel Weight 11.6 Kg 2 FLUEBOOST LIMITED

DISCHARGE NOISE SOUND POWER MEASUREMENTS, dba re 1pW Power Level Pressure level at 3M Pressure level at 10M HIGH SPEED Frequency (Hz) 63 125 250 500 1K 2K 4K 8K Lw 62.5 65 69.5 74.4 67 64.9 63 53.7 77.2 42 44.6 48.6 53.4 46.6 44.4 42.6 33.3-26 -16-9 -3 0 +1 +1-1 16 28.6 39.6 50.4 46.6 45.4 43.6 32.3 1.6 2.9 4.0 5.0 4.7 4.5 4.4 3.2 31.6 34.1 38.6 43.5 36.1 34 32.1 22.8-26 -16-9 -3 0 +1 +1-1 5.6 18.1 29.8 40.5 36.1 35 33.1 21.8 0.6 1.8 3.0 4.1 3.6 3.5 3.3 2.2 dba / M 53dBa /3M NR49 44dBa/ /10M NR39 Power Level Pressure level at 3M Pressure level at 10M LOW SPEED Frequency (Hz) 63 125 250 500 1K 2K 4K 8K Lw 53.5 56.1 62.6 59.1 54.7 52.6 49.3 36.0 65.8 33 36.7 42.2 38.7 34.26 32.16 28.9 15.56-26 -16-9 -3 0 +1 +1-1 16 20.7 33.2 35.7 34.26 33.16 29.9 14.56 1.6 2.1 3.3 3.6 3.4 3.3 3.0 1.5 31.6 25.2 31.7 28.2 23.8 21.7 18.4 5.1-26 -16-9 -3 0 +1 +1-1 5.6 9.2 22.7 25.2 23.8 22.7 19.4 4.1 0.6 0.9 2.3 2.5 2.4 2.3 1.9 0.4 dba / M 43dBa /3M NR35 30dBa/ /10M NR25 MODEL: FB350 GAS FIRE FAN 3

ELECTRICAL INSTALLATION It is strongly recommended that all electrical installation work is carried out by a qualified electrician and that all wiring must conform to the relevant codes of practice and IEE Regulations. Mains supply must be 230V / 1Ph / 50Hz The Flueboost unit must be correctly earthed a double pole fused (5Amp class F) isolating switch must be incorporated into the basic wiring circuit. Note: In all installations it is essential that the Flueboost is connected in the supply circuit between the appliance controls and the gas valve, so in the event of fan failure the gas valve will remain shut. Safety Ensure, before switching on, that no parts have been removed and that all screws are tight. Failure to check might result in a safety hazard. Operation on the mains supply other than that stated might result in damage to the fan components and produce a hazardous situation. Materials and Fire Characteristics The materials employed in the manufacture of these fans do not constitute a fire hazard. A correctly installed fan is not subject to self-ignition. The terminal block, motor winding and wiring may give of a small quantity of toxic fumes in the event of a fire source external to the fan. The materials used in these components are all self-extinguishing. The majority of the unit utilises non-combustible materials. 4 FLUEBOOST LIMITED

UNIT WIRING YELLOW (EARTH) SPEED CONTROL YELLOW (Earth) LIVE ON/OFF SWITCH No. 4 (Motor Live) NEUTRAL SWITCH LIVE TO GAS SOLENOID No. 5 (Motor Neutral) NO. 3 (Pressure Switch Input Live) Common NO. 1 (Pressure Switch Output Live) N/O No. 2 (Pressure Switch / Fan Failure) N/C LOOSE SOCKET GAS FIRE GAS SOLENOID 240 volt 1 phase supplied by others MAIN GAS PIPE INSTALLATION Loft Chimney stack/chimney breast Ceiling void Please ensure there is adequate circulation of air around the fan for cooling see minimum clearance recommendations. The fan should be mounted as per detailed instructions. Any other method of mounting must be approved by Flueboost in writing. The Flueboost fan may be positioned in the primary flue (please see figure 1 on page 6) but must have a draft stabiliser/diverter on the system. The flue pipe size must be selected so velocity is less than 4 m/s. MODEL: FB350 GAS FIRE FAN 5

figure 1 MIN 0.5 1METRE AWAY FROM TERMINAL FAN CAN BE FITTED HORIZONTALLY OR VERTICALLY FAN MUST BE 1 METRE AWAY FROM FIRE PLACE OPENING MIN 300mm REQUIRED AWAY FROM ANY BEND LOCAL ISOLATION BY FAN FLUEBOOST CONTROL 700mm REMOTE SWITCH SMG 700mm MAX FIRE OPENING SIZE MAINS GAS MAIN The front cover must be on a vertical plane or on top but never be facing down. The front cover must never be placed against a wall; the fan requires an access panel for routine maintenance. Please follow the minimum clearance guidelines illustrated on page 7. The Flueboost requires air to circulate & cool itself down so please ensure this is established prior to installation. The Flueboost is for 230V/ 1Ph /50Hz appliances only. Air must be allowed to pass through the fan on start up. The direction of flow is indicated on the side of the fan in the form of an arrow. Should another fan be in the same room as the unit please contact Flueboost prior to installation as it may affect performance. When fitting the Flueboost into the flue, the gap between the spigot and the flue duct should be caulked with a suitable material, i.e. fire cement, high temperature silicone sealant. The fan is to be installed internally only (not external), and must never come into contact with liquid. 6 FLUEBOOST LIMITED

MINIMUM CLEARANCE RECOMMENDATIONS 670mm 250mm FAN COOLING OUTLET VENT 770mm 150mm WALL FIXINGS 15mm SPACERS FLUEBOOST 350 Gas Fire 113.5mm 200mm 200mm FAN COOLING OUTLET VENT 240mm CLEARANCE FOR SUB ASSEMBLY TO BE REMOVED FOR MAINTENANCE HIGH TEMPERATURE FLEXIBLE CONNECTORS FAN COOLING INLET VENT 150mm WORM DRIVE CLIPS 200mm Dia FLUE SPIGOT 7

MAINTENANCE No special attention is required. The fan is pre-oiled and has sealed for life bearings to ensure reliable operation of the Flueboost for many years. At the same time, the opportunity should be taken to remove dust or foreign matter on and around both the unit cooling and main impellers. These operations can be effected as follows. Isolate the Flueboost unit from the mains electric supply. Remove the front cover via 8 x M6 screws. Release the 12 x M6 screws securing the controls tray to the flue box, the controls tray may now be withdrawn. The cooling impeller may now be cleaned with a light brush or an air compressor. Check the pressure switch for satisfactory operation. Re-assemble the Flueboost and reconnect to the mains electric supply. In the event of a fan failure, isolate from the mains electric supply before attempting to identify the cause. Note The Flueboost is designed so that it is not necessary to remove the main flue box from the flue ducting for either repair or maintenance. All working parts may be removed via the controls tray as a sub assembly. WARNING Never remove the front cover without first disconnecting the mains electric supply. This fan must never be exposed to liquids. If a liquid accidentally splashes over the fan immediately disconnect the fan from the mains electric supply, clean and dry thoroughly before reconnecting. 8 FLUEBOOST LIMITED

COMMISSIONING The fan must only be commissioned by a fully qualified gas safe engineer. SAFETY INFORMATION 1. Inspection of goods upon receipt Check the information on the fan case label and ensure that the goods are compatible with your requirements, inspect for any sign of damage including internal i.e. parts may have broken free and report any damage immediately to the supplier do not install or use a damaged fan. 2. Storage Store in a dry clean environment. 3. Handling When handling the fan never allow its weight to bear on the cable or electrical fittings. 4. Safe use Do not use the fan in an environment containing flammable or corrosive gasses or dust. The fan must be fitted within the flue system so that the impellers are guarded i.e. not accessible. Ensure, before switching the flue fan on, that no parts have been removed and that all screws etc. are tight - failure to do so might result in a safety hazard. Operating the fan on an electrical supply other than 230V / 1Ph / 50Hz will damage the fan and produce a hazardous situation. In the event of a fan failure, isolate the fan from the mains electric supply before attempting to identify the cause; this is of particular importance due to the fan having rotating parts within the controls tray. The fan must never be exposed to liquids. If a liquid accidentally spills over the fan, disconnect the fan from the mains electric supply, clean and thoroughly dry before inspecting. After satisfactory inspection of both the fan and installation, then it may be considered operational, providing the health and safety requirements are met; as specified within the Machinery Directive 89/392 and current revisions. MODEL: FB350 GAS FIRE FAN 9

5. Supply voltage 230V / 1Ph / 50Hz 6. Material content The materials employed in the manufacture of this fan do not constitute a hazard. 7. Fire characteristics A correctly installed fan is not subject to self-ignition. The terminal block, wiring loom and motor may give off a small quantity of toxic fumes in the event of a fire external to the fan. The materials used for these components are self-extinguishing 8. Disposal No special hazards are envisaged. Do not dispose of by incineration. RETURNS POLICY If the product is not no longer required and returned to us within 14 days of purchase in the original packaging then we will offer a full refund less a 20% re-stocking charge (subject to inspection of the goods). Any goods returned after this time will considered on an individual basis and only a credit against a future purchase will be offered. 10 FLUEBOOST LIMITED

GUARANTEE Flueboost Ltd guarantees its products for two years from the date of purchase against faulty materials or workmanship. In the event of any part being found defective the product will be repaired, or at the companies discretion replaced, without charge, providing the product: Has been installed and used in accordance with the instructions provided with each unit. Has not been connected to an unsuitable electric supply. Has not been subject to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. If Claiming Under Terms of Guarantee Please return the complete product, carriage paid by your original supplier or to Flueboost Ltd, ensuring it is adequately packed and accompanied by a letter clearly marked GUARANTEE CLAIM stating the nature of the fault and evidence of the date and source of purchase. This guarantee is offered as a benefit, and does not affect your legal rights. Consequential Claims May we remind you that our guarantee covers replacement or repair by ourselves of the goods agreed by us as faulty. It does not include reimbursement of costs incurred unless specifically agreed in advance in writing. Agreement of this type can only be authorised from the appropriate person at Flueboost Ltd, no one else is authorised to alter or modify our terms of guarantee. MODEL: FB350 GAS FIRE FAN 11

Unit 6 The Grove Parkgate Industrial Estate Knutsford Cheshire WA16 8XP T: 01565 755 599 F: 01565 755 055 E: info@flueboost.co.uk www.flueboost.co.uk