ERS-3600B. PERS-3600B Personal Emergency Reporting System

Similar documents
PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear

Linear Personal Emergency Reporting Solutions

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

2GIG GC3 Security & Automation System. Fingertip Guide

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

1. Introduction. 2. Product overview

SUPERVISED WIRELESS SECURITY CONTROL PANEL

NON-MONITORED EMERGENCY CALL SYSTEMS

CONTENTS. (User s Manual)

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

MXD3G User Manual Revision 0 July 29, 2013

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

First Alert 1200C Installer Notes M. Leuck

l 02-April-2010 For INSTANT CARE

The complete wirefree security alarm solution

Supervised Security System Owner's Guide

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Sidekick II Receiver Model # SK2-SS 418MHz

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DESCRIPTION INSTALLATION

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

PROGRAMMING PROCEDURES (Table 3)

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL

NESS 5000 SERIES DIALLER

Simon XTi Quick Operation Guide

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

RE6100 Series Helix Security and Automation Platform

All-In-One Wireless Security System V1.0. Model #: MG-6060

INDUSTRIALMANDOWN & LONEWORKER

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

AIRPORTS. CARECALLER PowerfulSecuritySolutionsForSeriousSecurityNeeds

Property of Monitronics Inc

User's Manual VISTA-40 N7003V1 6/97

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

MEDI-MINDER USER MANUAL

D169 2-Way Voice Verification Module. Installation and Operating Manual Radionics 34105B 3/97

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Version 1.03 January-2002 USER S MANUAL

Safewatch Pro 3000 System Manual

LYNXR-2 Series Security System

A Complete Smart Care Solution

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

Control/Communicator Installation Manual

abode Web app Functionality

PiSector GSM Cellular Wireless Alarm System

Condominium Security Management System

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

EVO192 v3.0 Fire and Burglary What s New

Easy Series Intrusion Control Panel. Selection Guide

Destiny Destiny Owners Manual

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

2000 Series. Program Entry Guide. Control Panels

Contact ID as of 2/2/2015

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

GEM-P800 Programming Instructions

Simon XT User Manual R-11 and R-11-CN P/N REV B ISS 13JAN11

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

AXI LED USER MANUAL (REV. 1.0)

Auto Dialer. Manual E-921APQ E-921GPQ

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

SMARTWALK DEMENTIA WANDERING SYSTEM

Control/Communicator

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

Radionics D4112 Program Sheet

Lifeline Vi Clever, not complicated

DIY Home Security Support 30 numbers wireless sensors

Contents. Glossary

status AW1 Plus WiFi Alarm System User Manual

Training Manual Multi-Language with Wireless

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

P Zone Expandable Hybrid Security System

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

DESTINY OWNER S MANUAL

ReadyGuardR-2. Security Systems. User Guide. K /08 Rev. A OFF ARMED READY PLAY ESCAPE VOLUME AWAY 4 5 RECORD TEST ADD STAY LIGHTS ON

User's Manual 5120XM N8031 6/96

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

ADEMCO LYNX XL SERIES Security System

Digiplex LED Keypads User s Manual

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

Transcription:

PERS-3600B Personal Emergency Reporting System ERS-3600B A Complete Emergency System For Comprehensive Care The Linear PERS-3600B includes a built-in speakerphone and reminder message capability, providing a comprehensive Personal Emergency Reporting System.

Features and Functions The PERS-3600B offers advanced capabilities as the hub of a wireless Personal Emergency Reporting System, and can be used with the full suite of Linear s DXS wireless personal transmitters and accessories. The table-top Console features a built-in speakerphone and digital communicator for reporting and two-way voice communication with the Central Monitoring Station. Advanced, full-duplex speakerphone circuitry provides superior two-way voice communication throughout the home. Simple Operation Pushbutton Emergency Assistance A button press on the Console or wireless transmitter automatically places a call to the Emergency Monitoring Center, staffed 24 hours a day by trained professionals. Operators then notify pre-selected contacts to respond in specific situations. Multiple Zone Capability Capacity for up to 16 individual sensors. Can provide emergency reporting for multiple users, and/or household monitoring functions. Silent Alarm and Alarm Tones Provides silent alarm capability (as panic button for domestic violence applications) and separate tones for emergency, fire and CO conditions. Built-In Activity Timer Monitors household activity when turned on (system default is off). Set for 8, 12 or 24-hour operation, the emergency alarm will trigger automatically if the time set elapses before an activity transmitter is triggered, or before the Console s HOME button is pressed. Flexible Reporting Options Console routes reports to any of three programmed telephone numbers, primary, secondary or supervisory. Personal Wireless Transmitters Effective signal coverage extends throughout the house and outdoors Extensive Audio Capability Easy to Use Console Console speaks to the subscriber in clear, natural language during set-up and system operation. Two-Way Voice Capability Users talk directly to Emergency Monitoring Center professionals via 2-way voice activated, 2-way manual, or 1-way, listen-only audio communications. Remote Call-in Feature For Speakerphone Operation Subscriber can answer the phone with a pendant press. Family members or caregivers can also enter a PIN code to start a speakerphone call if the client can t reach their phone or pendant. Reminder Messages Plays 15-second audio messages, recorded locally in a family member s voice, to remind subscribers to take medications, call someone, get ready for an appointment, etc.

Supervision and Test Full System Auto Test The Console can be programmed to monitor all zones for proper operation, and can provide a periodic test report to the monitoring station on a 1, 7 or 30 day interval. Transmitter Status Reporting & Supervision Optional status reporting mode allows the transmitter to be paired with zone supervision at the Console for automatic sensor status trouble reporting. Console-Supervised Battery Recharging If the backup battery becomes low, the POWER light will flash and the condition can be reported to the central station. Transmitter Low Battery Monitoring Under normal operating conditions, the transmitter detects low battery voltage and provides a status report to its console. Effortless Installation Easy Installation and Programming Set up is made easy by Linear s RA-2400 remote access software. Tested for Reliability UL listed as Home Healthcare Signaling Equipment per Standard 1637. Options For Expanded Utility Installation and use of a variety of optional equipment broadens the PERS-2400B s utility. Smoke Detector The DXS-73 Supervised Photoelectric Smoke Detector will sound a loud alarm when smoke is detected, Twenty seconds after the local alarm sounds, the built-in transmitter sends a digitally coded wireless signal to the PERS console. The wireless signal will be repeated every 20 seconds as long as smoke is still present. Carbon Monoxide Detector The DXS-80 Carbon Monoxide Detector will initiate an automatic call to the Emergency Monitoring Center. Warning tones will be sounded by the console and the detectors will alert the subscriber, even during sleep.

Versatile personal transmitters can be worn as a pendant, wrist band or clipped to a belt or pocket. Compatible Supervised Stationary Transmitters PRODUCT MODEL NUMBER DESCRIPTION DXS-31 SST00073 Supervised Universal Door/Window Transmitter (for emergency and inactivity reporting) Supervised Universal Door/Window transmitter with built-in magnetic switch, accepts N/O or N/C external devices, supervised for low battery and sends hourly status signals DXS-32 SST00100 Supervised Miniature Door/Window Transmitter Supervised miniature Door/Window transmitter with built-in magnetic switch, supervised for low battery and sends hourly status signals DXS-54 SST00074 Supervised Passive Infrared Motion Detector (for inactivity reporting) Supervised passive infrared motion sensor with built-in transmitter, supervised for low battery and sends hourly status signals DXS-73 SST00113 Supervised Photoelectric Smoke Detector Supervised photoelectric smoke detector with built-in transmitter, supervised for low battery and sends hourly status signals DXS-80 SST00116 Supervised Carbon Monoxide Detector Transmitter Supervised carbon monoxide (CO) detector with built-in transmitter, supervised for low battery and sends hourly status signals

Available Models and Accessories PRODUCT MODEL NUMBER DESCRIPTION PERS-3600B SSC00062B Personal Emergency Reporting System Supervised emergency reporting system receiver/control, monitors up to 16 transmitters, can be manually activated, activity timer option, two-way voice option, point-id reporting allows multiple subscribers RJ-ADAPT AAE00435 RJ-31X Telephone Adapter RJ-31X adapter for PERS-3600B Console RSM-1 CAE00191 Remote Speaker/Microphone External Remote Speaker / Microphone kit for Two-Way voice for the PERS-2400B or PERS-3600B, comes in an attractive plastic case that houses an 8-ohm speaker and microphone, unit can be tabletop or wall mounted Compatible Supervised Portable Transmitters (DXS Format) PRODUCT MODEL NUMBER DESCRIPTION DXS-62A SST00090A Supervised 1-Button, 1-Channel Water-Resistant Wristband/Pendant Transmitter Miniature one button, one-channel, water-resistant, supervised transmitter designed for use in emergency applications, includes adjustable lanyard with breakaway release, wrist band and belt/ pocket clip, visual activation indicator. DXS-64 SST00112 Supervised 1-Button, 1 Channel Pendant Transmitter Pendant style water-resistant transmitter designed for use in emergency applications, includes adjustable lanyard with breakaway release, visual activation indicator DXS-LRW SST00123 Supervised 1-Button, Long-Range Wristwatch Transmitter Wrist version of the LR transmitter series, designed for use in emergency applications. Updated design, shock and waterresistant*, supervised transmitter with improved transmission range and two-color visual activation indicator. Capable of field enrolling with compatible panels and consoles. DXS-LRP SST00122 (White) Supervised 1-Button, Long-Range Pendant Transmitter SST00126 (Black) Pendant version of the LR transmitter series, with performance features as listed in the DXS-LRW. Product is provided factory pre-assembled on an adjustable lanyard with a breakaway release. * LR Transmitters - water resistant up to 30 minutes at a depth of three feet DXS-65 SST00121 Supervised Emergency Alarm Transmitter Supervised emergency transmitter with large HELP button, LED transmission indicator, for wall mounting or tabletop use, extra blank aqua button included

Specifications R A D I O Transmitter Capacity: 16 DX or DXS devices Operating Frequency: 315 MHz RF Format: Linear DX, DXS Receiver Type: Dual diversity, superheterodyne RF Programming Method: Linear quick-learn COMMUNICATIONS Communicator Formats: Contact ID and 4 x 2 (General or Point-to-Point), ADEMCO Contact ID Dialing Method: Pulse or tone dialing formats, field-enabled Communicator Reports: a. All transmitter alarms b. All transmitter trouble Supervisory Low battery c. All inactivity alarm reports d. AC power failure e. AC power restored f. Console low battery g. Console emergency alarm CONSOLE Controls: a. HELP: Large round button with multiple actuation points, Braille characters b. CLEAR: Momentary for system reset, call cancellation c. HOME: Momentary to reset timer or press and hold for 5 seconds to disable the function d. POWER SWITCH: Controls 120 VAC source, as well as the backup battery Indicators: Four LEDs (POWER, STATUS, SENDING, HOME) Connections: a. In and out telephone jacks b. External speaker, dialer output, and dialer power terminals Outputs: One form C relay output activated upon initiation of any alarm condition Programming Method: Via RA-2400 remote access software Inactivity Timer: Software programmable for 8, 12, or 24 hour cycles Silent Alarm Feature: Software programmable per channel Delayed Alarm Feature: Software programmable per channel; delay time 15 or 30 minutes; note that an alarm will not be transmitted if alarming transmitter sends a restore signal to the console prior to delay timer timeout Selectable Two-Way Voice Activation: Software programmable per channel Speakerphone Option: Software programmable; call duration time selectable for 15, 30, or 60 minutes Pulse/Tone Dialing: Software or console programmable Audible Output: Integral siren Output Tones: Distinct alarm tones provided for emergency and fire alarm conditions; provisions for timer reset tone also incorporated into system Dimensions: 9.00 in L x 5.50 in W x 5.00 in H (228 x 137 x 76 mm) Backup Battery: Recommended battery is 12V, 1.2 amp-hour; Linear part number 100104 Backup Period: 30 hours minimum Accessories: Optional RSM-1 Remote Speaker/Microphone Listing: UL per Standard 1637, Home Healthcare Signaling Equipment Listing: UL per Standard 1637, Home Healthcare Signaling Equipment Note: The optional RSM-1 is not UL-listed and is not intended to be used in a UL-listed PERS system. For more information, please visit www.linearcorp.com. Specifications subject to change without notice. UL1637 LISTED Linear LLC 1950 Camino Vida Roble Suite 150 Carlsbad, CA 92008 800.421.1587 www.linearcorp.com Copyright 2012, Linear LLC P/N 231283 AX2 Printed in China