ATMOX MAXX System THE Complete Moisture Control System for Crawlspaces. User s Guide

Similar documents
ATMOX EZ System Installation Manual & User s Guide

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL

Chore-Tronics Load Cell Indicator

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

INSTALLATION & OPERATION MANUAL

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

VX SERIES Wireless Thermostat with Occupancy Sensor

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

User Manual. Juice Extractor MODEL: WJE2BSLA

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Energedry Elite Eliminator Pest Control Electric Heat System

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

ion Genesis Pump Controller

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Mold Alert... Operation Manual P0270

PCO/UV N-Duct Model. Owner s Guide

Automatic Phone-Out Home Monitoring Systems

Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

professional the the the


Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Energedry Eliminator 52K

636 and 646 Keypads. User s Manual

Instruction Leaflet 99.97% TRUE HEPA AIR PURIFIER. pure indoor living MODEL: BAP925-CN. Replacement filters: A1230H and A1260C

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Horizontal Bottle Cooler Installation and Operation Manual

AUTO SPEED BLENDER INSTRUCTION MANUAL MODEL: BLCLMB1

CA 120 Owners Manual of 10

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Welcome to a Healthy Home

[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation

Steam Bug. World's smallest steam iron great for travel

Cellular Alarm Quick Start Installation Guide

RATIO:GUARD Model E-1S EC Monitor

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

Whynter Portable Ice Maker 33 lb capacity - White

26 LB CAPACITY ICE MAKER

User s Manual and Warranty Information ThyssenKrupp Access

CD6102 / CD6102 OC / CD6102-2

No Touch Door Release Exit Sensor ACA-NTEB

Radial 8 Heater For Professional use only

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

Portable Dehumidifier with Internal Pump

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Model 718W Owner's Guide

INSTRUCTION MANUAL P Heating and 1 Cooling

Owner s Manual MODEL 8555

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

RC-2000 Thermostat Installation Instructions

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Operator s Manual. The Quietek

Remote Vehicle Control System

Model 65 Humidifier Control Owner s Manual

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

Electrode Steam Homeowner s Manual HOMEOWNER S OPERATING MANUAL EFS-01

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Installation & Operation Manual Ice Cream Freezers

PRODUCT MANUAL. TT-MTM2 Hard-Wired Controller with Remote

Protégé Eclipse LED Keypad User Manual PRT-KLES

Radio Frequency Do s & Don ts

Carwin COMPRESSOR SELECTION PROGRAM

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

TFD-1 Installation & User s Guide

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

Portable Dehumidifier

640 Series Advanced Remote Vehicle Security System

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Installation and Operation Instructions Luxury Towel Warmer Free Standing or Wall Mounted

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

Legacy Non-Programmable Owner s Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Surna 25-Ton Chiller Operating & Maintenance Manual

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

DIGITAL STEEL FIRE & SECURITY

OPERATION AND INSTALLATION MANUAL

5) Do not start or stop the unit by inserting or pulling out the power plug.

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

CO2 Sensor User and Installation Guide

MN908 No. 282C Replaces 282B LB7013

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

INSTALLATION AND OPERATION INSTRUCTIONS

Projection Alarm Clock USER GUIDE

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle

Humidif ier. Cool Mist. Instruction Leaflet SCM7809-CN PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS FILTER# : BWF100 FILTER TYPE : WICK

Transcription:

ATMOX MAXX System THE Complete Moisture Control System for Crawlspaces User s Guide

Welcome to ATMOX This User s Guide will cover the basic operation of the ATMOX System. For instructions on installation, setup and software adjustments, please refer to an ATMOX Installation Manual. Uses powerful, yet quiet fans Creates cross circulation of air flow Ventilates only when beneficial Addresses odor issues KEY BENEFITS WHY ATMOX? Energy efficient, uses less than 150 watts of power Option to incorporate a dehumidifier Fully automatic once installed 2

Operating Principle Crawlspaces need dry and proper ventilation. The goal of ATMOX is simple reduce the moisture and humidity level in your crawlspace. The basic principle of how it works is also simple. Ventilate with good air from the outside only when it will improve the conditions in the crawlspace. Using sensors, ATMOX calculates dew point inside and outside your crawlspace to determine when the fans or dehumidifier should run. The fans allow for natural air circulation into the crawlspace. An optional dehumidifier, if equipped, is only used when the system cannot find good air from the outside, making the system energy efficient and environmentally friendly. Once installed, the ATMOX System will operate on its own and automatically. The system will adjust for seasonal changes as needed. There is no need to manually make any changes to the system. 3

ATMOX Settings The ATMOX System is a fully automatic and softwarecontrolled moisture management system. The system continually measures conditions inside and outside to determine the best course of action for your home and crawlspace. The system is preset to the proper settings. It is very rare for adjustments to be necessary. If you have inadvertently made changes by pressing buttons, talk to your installer about setting system back to its default settings. Do not adjust the settings on your system without talking to your installer. Improper settings can negatively affect the operation of the ATMOX system. 4

ATMOX MAXX System Standard System Components Optional Sensors MAXX Controller A-Box Wood Moisture Sensor MAXX Controller B-Box High Water Alert Sensor Outside Temperature and Humidity Sensor Inside Temperature and Humidity Sensor Product Specifications Usage: Variable from 1.5-150 W Input Voltage: 85-132V AC Output Voltage: 12-13V DC Output Current Range: 0-12.5A Data Input: 2 Temperature/RH, 1 Wood Moisture, 1 Water Power Output: 3 Switched, 1 Constant, 2 Optional Use only approved ATMOX Fans and Accessories with the ATMOX MAXX System 5

Basic System Configuration OUTPUT Sensors measure and provide data to the Controller. RED OUTPUT ORANGE OUTPUT YELLOW OUTPUT PURPLE OUTPUT 6 Fans will run when the outside air is beneficial. Fans will run when the outside air is beneficial or when inside relative humidity is elevated. (Runs with Red Output and with Yellow Output) Fans or dehumidifiers will run when the outside air is not beneficial and inside relative humidity is elevated. A constant power source for accessories.

Informational Display Screens The ATMOX Controller will automatically rotate through its standard informational screens about every fifteen seconds. System Screen This screen displays the name of the ATMOX model and the installed software version. To view all screens, you can wait and watch as it scrolls automatically. For faster rotation of screens, you can manually change the display. Press the M Button on the panel to scroll through each of the screens. The M Button will also light up the screen for easier viewing. Note: The system will continue to auto rotate even while the M Button is being pressed. 7

Informational Display Screens Temperature Screen The Temperature Screen displays the temperature outside and inside the crawlspace. Dew Point Screen The Dew Point Screen displays the dew point outside and inside the crawlspace. The ATMOX system evaluates the outside and inside temperature to determine whether or not to ventilate the crawlspace. If the temperatures are too cold or too hot based on several calculations, the system will not ventilate with outside air. The ATMOX system automatically adjusts its temperature parameters for different times of the year. Note: If the outside sensor is located in direct sunlight, it will often heat the metal housing causing the sensor to read a temperature that is higher than the ambient outdoor temperature. The overall outside moisture calculations (dew point) will not be incorrect, so this generally does not affect basic operation of the ATMOX system in determining when fans should be running. Dew point is the key to the ATMOX system. Dew point is calculated from the temperature and humidity measurements and gives you the best indicator of moisture in the air. A higher dew point means there is more moisture in the air, and a lower dew point means there is less moisture in the air. The ATMOX system does not activate ventilation on an absolute number but instead uses a comparison of air in the two locations. Under most circumstances, the fans will ventilate when the outside dew point is 1 to 1.5 degrees lower than inside dew point. There are some exceptions to this built into the software, for example temperature parameters need to be met. There is also a time delay of 15 to 30 minutes to conserve energy and avoid constant on and off. This means that you will not always see instantaneous change in operations. 8

Informational Display Screens Relative Humidity Screen The Relative Humidity Screen displays the relative humidity outside and inside the crawlspace. Wood Moisture Screen The Wood Moisture Screen displays the wood moisture content from the optional sensor in the crawlspace. Relative humidity is measured by the sensor along with temperature in each location and is used to calculate dew point. An important component of relative humidity is the word relative. Humidity is relative to temperature and can fluctuate significantly with changes in temperature. ATMOX ventilates based on a dew point comparison for this reason. It is possible for the humidity outside to be higher than inside but to still trigger fans to run. It all depends on the corresponding temperature. In general, the ATMOX system is not looking to target an exact humidity level but instead is looking to have variations mirroring the outdoors. The goal is not to have extremely high humidity in the crawlspace for extended periods of time. There are some operations on the ATMOX system that are triggered by inside humidity levels. Under default settings, if the crawlspace humidity exceeds 80% and outside dry air is not beneficial, then the controller will activate the Orange and Yellow outputs used for internal fans and an optional dehumidifier. Once activated, the fans and/or dehumidifier will continue operation until the inside relative humidity is below 75% or when outside air is drier. Your system will automatically trigger these outputs even if your setup does not have a dehumidifier or internal fans. The relative humidity setting to activate Yellow and Orange outputs is adjustable. Contact your installer if you have questions about custom settings. If the wood moisture sensor is not installed, then the display will read N/A. If the sensor is installed, then the wood moisture from the sensor will be displayed. Wood moisture is a great tool in evaluating the actual moisture in a crawlspace. The wood moisture will vary throughout the year. In general, 10%-16% wood moisture content is a healthy range for a vented crawlspace. The ATMOX system has an alert to notify you if the wood moisture reading is too high. Under the default setting, the alert is triggered at 20% and once activated will not turn off until wood moisture content decreases below 18%. If desired, this setting can be adjusted. Contact your installer if you have questions about custom settings. 9

System Operation, Alarms and Alerts ATMOX MAXX System ALARM This light Indicates there is an alert on the system. Check screen to identify the reason for alarm. FANS and DEHU When Fans light is on, the outside conditions are better and the fans will be operating. When Dehumidifier light is on, the outside air is not beneficial AND the relative humidity inside the crawlspace is elevated. BOTH LIGHTS OFF When both lights are off, the outside air is not beneficial and no fans are running. Crawlspace humidity is not elevated, and ATMOX system is waiting for any change in conditions. FLASHING LIGHTS Either or both lights may be flashing at times. This means the system is in a time delay for switching between operations. MANUAL Under normal automatic operation, this light is not illuminated. If the Manual light was accidentally illuminated, it can be turned off by pressing the bottom Arrow button one time to turn off. WINTER When this light is illuminated, the system is operating in its winter mode. When not illuminated, the system is operating in its summer mode. The system adjusts automatically between these modes. TEMP ALERT This light indicates the crawlspace temperature is very low. If lit, all fans and/or dehumidifier will not operate. 10

B-Box Components Overview Sensors are attached to B-Box via telephone wire and jacks. The Display A-Box is connected to the B-Box via telephone wire and jacks. The ATMOX System sends signal and power to the fans, relays and other accessories via low voltage 12v DC power. Each color represents an output for a different function of the system. Color-coded plugs connect the low voltage wire to the B-Box. Data Transmission Light There is a small light on the B-Box. If the light is flashing quickly, then data is not being received from A-Box. If the light is pulsing slowly, then data is being transmitted or received from A-Box. 11

System Notifications System notifications are designed to alert you of a potential problem. The following are all possible alerts: Wood Moisture Too High If the system has an optional ATMOX wood moisture sensor, this alert is triggered by moisture levels that are higher than they should be in the crawlspace. The crawlspace should be checked to determine cause. High Water Alert If the system has an optional ATMOX water sensor, this alert is triggered by standing water in the location of the water sensor. The water sensor is generally used in a sump pump or condensate line. The location of the water sensor should be checked if this alert is triggered. Box B : Check B There is a data connection problem with the wire between the A-Box and B-Box. Contact your installer or ATMOX for more information. Humidity Too High Under the system default settings, this humidity alarm setting is turned to the off position, so it may not be active on your system. If this alert is on for a brief period of time, there is no reason for concern as humidity can fluctuate. If this alert is on for an extended period of time, the crawlspace should be checked. Missing, None, Defect (Def), with inside or outside sensor Any of these alerts indicate that there is data connection problem with the corresponding sensor. First, try to restart the system to clear the error. Second, check the telephone wires and couplers between the B-Box and the sensor to see if anything is unplugged or damaged. If sensor is still not reading, contact your installer or ATMOX for more information. 12

Frequently Asked Questions What happens if we have a blackout or power outage? The ATMOX System obviously runs on electricity, so there will be no operation when the system does not have electrical power. When the power comes back on, the ATMOX system will automatically restart and continue normal operation. All settings are retained so there is no need to do anything. Will the fans running cause too much cold air to be brought in during the winter? The system adjusts for Summer and Winter ventilation modes. The fans will not bring outside air into the crawlspace below a set temperature setting. It is raining outside and the fans are running. What is wrong? The answer is probably nothing. You have to trust the system even when it doesn t seem intuitive. The fans will be activated by dew point and not humidity levels. If a cold front comes through (even with rain), it is possible that the colder air will have a lower dew point than what is in the crawlspace. The air with the lower dew point will be beneficial to the crawlspace. I have an alarm or a question, who should I contact? Contact your local installer first as they will have more information about the specifics of your home and system. For any additional information or questions, contact ATMOX by phone at 704-248-2858 or email info@atmox.com. 13

Maintenance As a homeowner, ATMOX suggests a periodic maintenance inspection of your ATMOX system and crawlspace by your installer. Conditions in and around your home are always changing. Please be aware of the following during other times of year: Power Connection If the ATMOX display screen is not showing any readings, it most likely has no electrical power and is not operating. In this case, see if something is unplugged or make sure that the outlet being used for the B-Box has power. If the A-Box has no display or if the B-Box has no power, then contact your installer for more information. System Alarms If the ATMOX system has an alarm such as missing hardware, then the system will not operate. Please check periodically to make sure that the display has no alerts needing attention. Fan Operation The ATMOX fans or vent covers should periodically be brushed off lightly to keep debris such as mulch or pine needles from blocking ventilation. The ATMOX display does not give a notification if any single or group of fans are not operating. Fans should periodically be checked for operation. 14 Moisture Management vs. Water Management It is important to note that the ATMOX system is a moisture management system and not a water management system. Dry air or a dehumidifier cannot get rid of standing water in the crawlspace. Every effort should be made to drain water away from the foundation. Gutters should be cleaned out, and downspouts should drain away from the house. If you have water intrusion in your crawlspace, this needs to addressed separately from or in addition to your moisture problem. If you live a very humid climate and have excessive ground moisture being released into the crawlspace during peak summer months, it may be necessary to incorporate an optional dehumidifier with the ATMOX system. Most homes do not need a dehumidifier, but there are exceptions. Contact your installer if you have questions about your situation or need more information.

Limited Three-Year Warranty of ATMOX When installed, operated, used and maintained as intended in residential applications and according to the instructions supplied with ATMOX products, ATMOX warrants its products for a period of 3-years from the date of purchase against any defects in material and workmanship. The products covered by this warranty include the control boxes, fans, sensors and wiring manufactured by ATMOX. ATMOX will repair or replace, at ATMOX s option, any ATMOX product or component found to be defective within the 3-year warranty period. ATMOX products are designed to improve conditions in the crawlspace, basement or attic, yet are limited by atmospheric and natural conditions over which ATMOX has no control and which are not covered by this warranty. ATMOX products are not warranted against damage caused by electrical surges, fire or other casualty, vandalism, or acts of God (including lightning strikes and floods). This warranty does not make representations regarding mold, insects, termites, water, rot, electrical, HVAC, roof, framing, foundation, floors, drywall, gutters, ice dams or other problems that may occur in a house structure. The warranty does not include any costs of removal or reinstallation. Third-party products by other manufacturers sold by ATMOX (such as dehumidifiers) are not covered by this warranty but may be covered under separate warranties by the product s manufacturer. Purchaser should contact third party manufacturers for warranty claims and coverage of third-party products not manufactured by ATMOX. ATMOX INC S LIABILITY UNDER THIS LIMITED WARRANTY IS STRICTLY LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE ATMOX PRODUCTS. OTHER THAN THE WARRANTIES EXPRESSLY DESCRIBED HEREIN, ATMOX DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ATMOX WILL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow certain limitations and exclusions of warranty, so these exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. 15

ATMOX INC 10612-D Providence Road #229 Charlotte, NC 28277 Phone: 704-248-2858 Fax: 704-675-9858 Email: info@atmox.com Website: www.atmox.com 16