Series 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units

Similar documents
AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Double Skin Casing Air Handling Units

Centeral Station Air Handling Unit

39G Air Handling Unit

TECAM S.A. Environmental Technology

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Double Skin Air Handling Units

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

ALL PRODUCTS BROCHURE

THE ULTIMATE ROOFTOP SOLUTION

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Easdale International INFINITY

Indoor Air Quality. For assured. Double Skin Air Handling Units

Cultivator & Hybrid Cultivator

YMA Custom Air Handling Units

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

AIR HANDLING UNITS. Revision AG 16-07

The ultimate in air handling units: directly and indirectly fired

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

Double Skin Air Handling Units

Vision and Skyline Semi-custom Air Handlers

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Enjoy the Delighting Comfort Brought by High Air Quality

The ultimate in air handling units: directly and indirectly fired

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

The ultimate in air handling units: directly and indirectly fired

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

RT-OA TM Rooftop Outdoor-Air (DOAS)

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Energy Recovery with Cooling and Heating

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

EHH SERIES DRAW THROUGH FAN COILS CFM

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

TYPICAL CPA SPECIFICATIONS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

YMA Air Handling Units

CU AIR CONDITIONING INDUSTRIES L.L.C

The ultimate in air handling units: directly and indirectly fired

MLR SERIES MODULAR AIR HANDLING UNITS

13 HYGENIC AIR HANDLING UNITS

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Cert. n Air Conditioning Vulcan Pro Air Handling Units

Classic Series AIR HANDLING UNIT. Range 1000 CFM to CFM 472 L/s to 9440 L/s

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

Modular Supply Make-Up Air Unit

FAN COIL UNITS. The optimal solution for limited space

T1/B1 OPTIONAL ASEPSIS HYGIENIC AIR HANDLING UNITS. Fully washable & free cold bridge design for food and low temperature applications

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

Central Station INSTALLATION OPERATION AND MAINTENANCE MANUAL. Air-Handling Units *AHAF *AHBF *AHDFS *AHDAF *AHDBF MODELS: *AHFS

Modular Air Handling Unit

Trane Performance Climate Changer Air Handlers. An air handler for every need.

photo by PFC Price Fan Column

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

T-Series Climate Changer Air Handler. It s Hard To Stop A Trane.

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s)

XeteX, Inc. All Rights Reserved.

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

CONTACT US. For more information,

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

ENGINEERING & SERVICE

39HQM Central Station Air Handling Units AiroVison Guide Specifications

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

RoofPak Applied Rooftop Systems

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Direct Fired Heater Model AD Specification

AHU N Range AQX. AQX Air handling units. Air flow 1, ,000 m3/h (350-44,400 l/s)

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

1.1 This section applies to air handling units for HVAC Systems.

Ducted Propeller. Airflow Volume

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Central Station Air Handlers

Double Skin Air Handling Units

Air Make-Up Units. Product Line Overview & Capabilities

AIR HANDLER SPECIFICATION

Air Handling Units. Real HVACR people who understand your needs.

Guide Specifications for InRow Direct Expansion

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

DIVISION 15 MECHANICAL

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

... DF / IDF Gas fired combined heating and ventilation ...

DF-IDF air handling units

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH

Performance Climate Changer Next generation air handler from Trane

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Supplying Clean Air to Industry

VERTICAL FAN COIL UNITS

Transcription:

INTRODUCTION For more than 100 years, DunhamBush has focused on innovative product development. Today, we provide a full portfolio of HVAC/R products from Fan Coil Units to large centrifugal chillers as well as many other innovative green solutions. Our commitment to innovation, matched with an aggressive attitude toward growth, makes DunhamBush a leader in global markets. Our product development is tailored to meet the specific needs of customers, buildingby meeting building, countrybycountry and regionbyregion. SCS3, Modular Central Station Air Handling Units, have an air volume range from 1000 to 56,000 cfm (1700 to No other HVAC/ /R manufacturer takes this approach to your performance expectations. 95,000 m³/hr) with new extruded aluminum frame profile. The entire product line features rigid construction, installation ease, control flexibility, high reliability and versatile functions, which is suitable for both commercial and industrial applications. TABLE OF CONTENTS Page No Introduction......... 2 Nomenclature... 2 DunhamBush SCS3 Series... 2 Maximum Airflow... 6 Physical Dimension... 6 NOMENCLATURE S AH D 2 FS 100 HM Q Units Series Air Handling Units Blank Standard Q Special Double Skin 2 Inch Blower FS Forward Curved BF Backward Curved AF Air Foil HM VM Model Horizontal Module Vertical Module DUNHAMBUSH SCS3 Series FEATURES The SCS3 range of Air Hand dling Units from DunhamBush features an extruded aluminium frame profile that provides a high level of unit design and application flexibility necessary to meet the rising demand for improved Indoor Air Quality. The unit is constructed using rigid nylon corners and double skin polyurethane foam insulated panels. These units can be disassembled for shipment and reassembled at site. Internal joints are insulated with rigid with special sealing strips and PE foam to provide airtight casing and minimize cold bridging. The SCS3 range is available in 17 models in horizont tal and vertical formats with a wide range of options and accessories that can be selected from the DunhamBush Selection Program. SCS3 Air Handling Units can be configured to meet the equirements of all standard and many specialised applications. 2

Product that perform By people e who care DUNH HAMB BUSH SCS3 S Series s SUPERIO OR CASING PERFOR RMANCE Excellent Air A Tightnes ss The casing is made up of panels, s strips. N New casing frame and sealing structure of the unit avoid ds that any member is of the interior support m exposed and a ensuress smooth internal surface, e easy for maintenance e and effectivve cleaning to reduce risk r of dirt an nd bacteria accumulatio on. New type off sealing strips between the frame and th he panels, and d careful sealin ng design to all panels s ensures exce ellent air tightne ess of the casing structure and minimizes aiir leakage. Thermal Bridge B Free DunhamBu ush unique fram me design enables interposst covered by panel to preve ent exposing in treated air, so the thermal brid dge at posts iss avoided. Each junction is subjected to special heat insulation treatment to preve ent the thermal brid dge effect. New w design of sc crew also prevvents the occu urring of therm mal bridge at screws, contrib butes to better casing g performance e. hermal Insullation Optimal Th The unit wall is made up by minimum 50mm 5 double sskin polyuretha ane foam (PU)) insulation panel with 0.5 m mm high strength pow wder coated stteel as externa al skin and 0.5 mm galvanized steel (GI) as internal skin. The sandwich panels are injected with PU foam of 40kg/m³ de ensity with lightt weight, good rigidity, and thermal conducttivity. Fan ns Filte ers Coill D Fo orward Curved D Ba ackward Curved D Airfoil D Plug Fans ashable Filter D Wa D Dissposable Filter D Ba ag Filter D Ca artridge Filter D HE EPA Filter D Ca arbon Filter D Ele ectrostatic Filter D Ch hilled Water Coil D Dirrect Expansion C Coil D Ho ot Water Coil Hea at Recovery D He eat Pipe D Plate Heat Exchan nger eat Recovery Wheels D He Note: Please con nsult DunhamBush representative for other o accessories re equired. 3 Draiin Pan D GI Steel ainless Steel D Sta

DUNHAMBUSH SCS3 Series CASING MECHANICAL CHARACTERISTICS Insulation Material Panel Thickness Casing Strength Casing Air Leakagee Thermal Transmittance Thermal Bridging Factor Polyurethane Foam 50mm D1 L1 T2 TB2 YOUR CHOICE OF FILTRATION Various options of filter type, filter media and filter efficiency are available requirement. to meet the different air quality High Efficiency Filter Bag Filter Carbon Filter YOUR CHOICE OF COILS Chilled water and DX cooling coils are manufactured from copper tubes with aluminum fins, copper fins, hydrophilic coated fins or other custom made coils. Heating can be hot water coil or electric heaters. Threeway pitch drain pan design discharges condensate quickly and prevents microbial growth. Condensatee pans of 304 stainless steel material are also available as an option. YOUR CHOICE OF BLOWER Forward, Backward Inclined and Backward Airfoils Centrifugal fans which are AMCA certified are available. You can select class I, II or III fans to meet your required air flow, static pressure, performance and sound power. Blower shall be coupled with pulley and motors. Forward Curved Fan Wheel ( FS) Airfoil Fan Wheel (AF) OPTIONAL A wide choice of accessory sections diffuser sections, mixing box sections, face and bypass damper sections, humidifier sections, reheating sections and heat recovery sections are available to meet the required air conditions application needs. For outdoor installation, applications in corrosive or hazardous atmosphere, other material options are available for the SCS3 range. Special motor voltages and dual speed motors can be supplied. Frequency inverter drive for Variable Air Volume applications is also offered as an option. 4

DUNHAMBUSH SCS3 Series COMPUTER SELECTION There is a powerful selection software program available to optimize the best arrangement and performance of any air handling unit for a specific job requirement with its computer selection programs. Standard components can be selected and be placed according to customer requirement. DunhamBush software gives immediate feedback if there is no suitable choice for the units. The program provides us with fan curves data, coil performancee data, dimension and shipment weight. 5

MAXIMUM AIRFLOW Model Size 12 22 32 40 48 64 80 100 120 150 180 210 240 270 320 420 520 Max. CFM m³/hr] 1667 [2833] 2667 [4532] 3896 [6620] 4813 [8178] 5729 [9735] 7563 [12851] 9625 [16355] 12375 [21028] 14438 [24533] 17000 [28886] 22000 [37382] 25458 [43258] 28708 [48781] 31958 [54303] 40000 [67968] 45000 [76464] 56250 [95580] PHYSICAL DIMENSIONN 1.) VERTICAL TYPE Model H W 2" Casing inches [mm] H1 H2 L 12 61 [1550] 22 68 7/8 [1750] 32 76 3/4 [1950] 40 84 5/8 [2150] 57 1/16 [1450] 48 84 5/8 [2150] 65 [1650] 41 3/8 [1050] 64 86 5/8 [2200] 80 3/4 [2050] 41 3/8 [1050] 45 1/4 [1150] 41 3/8 [1050] 80 102 3/8 [2600] 80 3/4 [2050] 53 1/8 [1350] 1000 110 1/4 [2800] 80 3/4 [2050] 61 [1550] 120 118 1/8 [3000] 80 3/4 [2050] 68 7/8 [1750] 150 133 7/8 [3400] 80 3/4 [2050] 57 1/8 [1450] 76 3/4 [1950] 57 1/16 [1450] 180 141 3/4 [3600] 104 5/16 [2650] 65 [1650] 76 3/4 [1950] 65 [1650] 210 150 1/2 [3815] 112 3/16 [2850] 65 [1650] 85 1/8 [2165] 65 [1650] 240 150 1/2 [3815] 120 1/16 [3050] 65 [1650] 85 1/8 [2165] 65 [1650] Notes: 1) Height (H) includes the unit base. 2) Spring type isolators are for standard fan of model AF64 onwards and FS80 onwards only. The rest are rubber isolator mounting. 3) L/H motor and R/H piping shown. 6

PHYSICAL DIMENSIONN 2.) DIMENSIONS FOR ACCESSORY SECTIONS FAN MODULE COIL MODULE EXTERNAL FACE AND BYPASS MODULE DISCHARGE PLENUM MODULE MIXING BOX MODULE ECONOMIZER MODULE ANGLE FILTER MODULE FLAT & BAG FILTER MODULE HEPA FILTER MODULE DIFFUSER MODULE SILENCER MODULE ACCESS MODULE Flat & Unit Unit External Coil Coil Mixing Economizer Angle Filter Diffu user Silencer Access Damper / Discharge Plenum Bag / Hepa Height Width Fan Face & Model (Long) (Short) Box Opening Size Plenum (H) (W) Bypass Filter Width (E) Length (L) Module Module Length (M) Inches [mm] 12 4 4 4 4 3 2 2 4 3 5 2 5 3 2 8 1/4 [210] 11 13/16 [300] 22 4 6 4 4 3 2 2 4 3 5 2 5 3 2 8 1/4 [210] 19 11/16 [500] 32 5 6 4 4 3 3 3 6 3 5 2 5 3 3 8 1/4 [210] 27 9/16 [700] 40 5 7 4 4 3 3 3 6 3 5 2 5 3 3 8 1/4 [210] 35 7/16 [900] 48 5 8 5 4 3 3 3 6 3 5 2 5 3 3 8 1/4 [210] 39 3/8 [1000] 64 5 10 5 4 3 3 3 6 3 5 2 5 3 3 12 3/16 [310] 39 3/8 [1000] 80 6 10 6 4 3 3 3 6 3 5 3 5 3 3 12 3/16 [310] 47 1/4 [1200] 100 7 10 6 4 3 4 4 8 3 5 3 5 3 4 16 1/8 [410] 47 1/4 [1200] 120 8 10 6 4 3 4 4 8 3 5 4 5 3 4 16 1/8 [410] 63 [1600] 150 9 10 7 4 3 4 4 8 3 5 4 5 3 4 16 1/8 [410] 63 [1600] 180 9 13 8 4 3 5 5 10 3 5 4 5 3 5 20 [510] 63 [1600] 210 10 14 8 4 3 5 5 10 3 5 5 5 3 5 24 [610] 70 7/8 [1800] 240 10 15 8 4 3 5 5 10 3 5 5 5 3 5 24 [610] 78 3/4 [2000] 270 10 17 8 4 3 5 5 10 3 5 5 5 3 5 24 [610] 78 3/4 [2000] 320 11 18 9 4 3 6 6 6 + 6 3 5 5 5 3 6 28 [710] 78 3/4 [2000] 420 11 20 10 4 3 7 7 7 + 7 3 5 5 5 3 7 35 13/16 [910] 90 9/ /16 [2300] 520 11 21 10 6 5 8 8 8 + 8 3 5 5 5 3 8 43 11/16 [1110] 90 9/ /16 [2300] Notes: 1) To calculate actual unit height, 1 Module = 7 7/8 [200mm] Unit base = 4 [100mm] eg. 2" Casing For Model 12, Unit Height (H) = (4 x 7 7/8 [200mm]) + 2 [50mm] + 4 [100mm] = 37 1/2 [950mm] (includes unit base) For Model 210, Unit Height (H) = (10 x 7 7/8 [200mm]) + 2 [50mm] + 4 1/2 [115mm] = 85 1/8 [2165mm] (includes unit base) 2) To calculate actual unit width and length, 1 Module = 7 7/8 [200mm] 2" Casing, For all Models, Unit Width (W) = (4 x 7 7/8 [200mm]) + 2 [50mm] = 33 1/2 [850mm] 3) Maximum shipping length, if, Unit Width <= 10M, Lmax = 15M Unit Width > 10M, Lmax = 10M 7