SCOPE OF ACCREDITATION

Similar documents
EMC Bayswater Pty Ltd

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing

Gas-fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating and instantaneous

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Certification Programs, Standards,

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

2013 ASHRAE. Standards & Guidelines CD. Contents

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Sound Performance Rating of Non-ducted Indoor Airconditioning

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

Performance of household electrical appliances-refrigerating. EN Domestic cooking appliances burning gas - Part 1-1: Safety - General

Sound Performance Rating of Outdoor Unitary Equipment

AHRI Certification Program Scopes - COOLING

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATION BODY ACCREDITATION PROGRAM QUALITY AUDITING INSTITUTE

10.6 Schedule of Accreditation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Presentation on HVAC: Heating Ventilation Air Conditioning

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

INTERNATIONAL STANDARD

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

PROTECTION PLAN CONSUMER GUIDE. Heating + Cooling + Plumbing + Appliance + Electrical. Home protection just got simple.

CERTIFICATE OF ACCREDITATION

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

CONTROLLED GOODS AND THE APPLICABLE SAFETY STANDARDS PART I DOMESTIC OR HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL APPLIANCES

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Compliance Engineering Ireland Ltd

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

ANSI-ASQ National Accreditation Board/ACLASS

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

PQS Independent type-testing protocol

PQS Independent type-testing protocol

Compliance Engineering Ireland Ltd

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames.

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Laboratory with fixed scope of accreditation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

HYUNDAI HEAVY INDUSTRIES CO., LTD.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TIPS ENERGY THE LESS YOU USE, 65 WAYS TO REDUCE HOME ENERGY USE THE MORE YOU SAVE CONSERVATION

IAS Accreditation Number UL International Germany GmbH Address Admiral Rosendahl Strasse 23 Neu Isenburg Germany

For more information on the MARR program or any questions on the product list, please refer to or contact MARR at

Energy Efficiency Labelling

Sound absorption coefficient Equivalent sound absorption area Sound absorption coefficient Sound absorption class

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

STS Directory Accreditation number: STS 0009

argos: model specifications Technical Data 2 Installation 3 Operate the Argos 5 Safety Rules 8 Certification 9

Type approval qualification of Photovoltaic Modules Procedures and test experiences

- Full test except clause (IPX1 IPX2) (Oxygen bomb test) and annex ต

Address 3255 Pepper Ln., Suite 112 Las Vegas, NV 89120, USA

SECTION/SUBSECTION (scroll down to view more listings; this list is arranged alphabetically) SCOPE. AHRI Section-Subsection Scopes

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Acoustical Test Methods and Sound Power Rating Procedures for Transport Refrigeration Equipment

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Revitalize Building Mechanical Systems (4619)

SOUND RECEPTION SYSTEM

Standard for tests for flammability of plastic materials for parts in devices and appliances

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Refrigeration Technology in Building Services Engineering

IEC PROJETOS EM VOTAÇÃO SETEMBRO E OUTUBRO. IEC ED1 - Rotating electrical machines - Part 23: Repair, overhaul and reclamation

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Owner s Guide and Installation Instructions Air Sourced 310 Heat Pump Water Heater

M7100 Pressure Transducer

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

How to ensure Thermal Comfort in buildings with CFD

Rules for Classification and Construction Additional Rules and Guidelines

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

Air Conditioning and process cooling Energy Components at a Glance

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This document is a preview generated by EVS

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

ISO INTERNATIONAL STANDARD

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

INTERNATIONAL STANDARD

Date of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

10606 Bloomfield Ave Santa Fe Springs, CA USA

½ Monitored Pneumatic Valve Patented Technology

Transcription:

SCOPE OF ACCREDITATION Vipac Engineers and Scientists Ltd T/A Gas Technology Services Victorian Laboratory Address Details: Victorian Technology Centre 275-283 Normanby Road PORT MELBOURNE, VIC AUSTRALIA Website: www.vipac.com.au VICTORIAN LABORATORY Accreditation Number: 676 Site Number: 21177 Contact Details: Mr Theo Michael Phone: +61(03) 96479700 Mobile: +61 0412243058 Email: theom@vipac.com.au Availability:Services available to external clients Note: Not all of the columns of the scope of accreditation displayed include data. The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation. ISO/IEC 17025 (2005) Infrastructure and Asset Integrity SERVICE PRODUCT DETERMINATION TECHNIQUE PROCEDURE LIMITATION/RANGE Evaluation of environmental durability of assets and equipment Public infrastructure equipment Railway Equipment for Signalling and Telecommunications Railway Applications - Rolling stock equipment Effect of environmental exposure Cold; Damp heat; Dry heat; Humidity; Shock (impact); Solar radiation; Temperature; Vibration; AS 60068.2.5 BS EN 50125-3:2003 Sections 4.3, 4.4, 4.9, 4.13; BS EN 50155:2007 Sections 4.1.1, 4.1.2, 4.1.3; IEC 61373:2010 Temperature in the range -40ºC to 60ºC only Relative humidity in the range 5% to 97% RH only Measurement of sound Buildings and construction Community noise Microphone AS 1055.1; AS 1055.2; AS 1055.3; ISO 3741 Clause 8.3 Page 1/8 February 23, 2018

levels in workplaces and the environment sites; Environments impacted by noise or vibration; Occupied spaces; Wind turbines; assessments; Habitability on passenger and merchant ships; Noise rating numbers; Occupational noise exposure level; Room acoustics - Reverberation time; AS 2436; AS 2460; AS 4959; (Method 11) over the AS/NZS 1269; AS/NZS 2107 Clause frequency ranges : 4; - 63 Hz to 8 khz in one AS/NZS ISO 717.1; AS/NZS ISO third octave bands ; 717.2; - 63 Hz to 8 khz in octave IEC 61400-11; ISO 2923; bands ISO 3741 Clause 8.3 (Method 11); ISO 3744; ISO 3746; MIL STD 740-1; Environment Protection Authority Policy N-1, N-2; Department of Primary Industries, Water and Environment - Tasmania; Victoria (Noise) Regulations; Electrical machinery Sound pressure level Microphone AS 1081.2; Department of Primary Industries, Water and Environment - Tasmania; ISO 3741 Clause 8.3 (Method 11) over the frequency ranges : - 63 Hz to 8 khz in one third octave bands ; - 63 Hz to 8 khz in octave bands AC and DC Generators; Rotating electrical machinery Industrial, earthmoving and agricultural tractors; Rail bound traffic and infrastructure; Road traffic; Vessels in waterways and ports; Airborne noise measurements Sound pressure level Microphone AS 2012.1; AS 2012.2; AS 2377; AS 2702; AS 1949; ISO 3095; ISO 3381; Vicroads Policy; New South Wales Transport Road and Maritime Services Page 2/8 February 23, 2018

Vibration analysis - Equipment condition monitoring Vibration analysis - Vibration levels in workplaces and the environment ISO/IEC 17025 (2005) Manufactured Goods Industrial machinery and rotating equipment Buildings and construction sites; Environments impacted by noise or vibration; Vessels; Airborne noise measurements Steady state vibration; Transient vibration; Vibration analysis and diagnostics; Ground borne vibration; Whole body vibration; ISO 10816-1:1995 Geophone DIN 4150-3 : 1999 ISO 2631.2 in the range 10 Hz to 80 Hz SERVICE PRODUCT DETERMINATION TECHNIQUE PROCEDURE LIMITATION/RANGE Acoustic performance evaluation of products Motor vehicles, motor cycles and mopeds Sound pressure level ADR 28/00; ADR 28/01; ADR 83/00 Airborne noise measurements Building materials and elements of construction Noise rating number; Sound insulation; AS ISO 140.4; AS/NZS ISO 140.7; AS/NZS 717.1 AS ISO 717.2 Compressor and prime mover units; Lawn mowers; Mixers; Power tools - Including pneumatic; Sound pressure level AS 2221.1; AS 2221.2; AS 3534; Department of Primary Industries, Water and Environment - Tasmania Airborne noise measurements Page 3/8 February 23, 2018

Air conditioning products; Air distribution products; Sound pressure level AS 2913 (Clause 3.2.5 only) ; BS 4718 (Clauses 2.3 and 3 only) ; BS 4856 Part 5; ADC 1062 R4; ARI 880 (Sound power components only); ARI 885 (Sound power components only); ARI 890 (Sound power components only); ISO 3741; AS 1217:1972; AS 1277 Static and dynamic insertion loss and generated noise level of air distribution system silencers, fan coil units, unit heaters and unit coolers ISO 3741 Clause 8.3 (Method 11) over the frequency ranges : - 63 Hz to 8 khz in one third octave bands ; - 63 Hz to 8 khz in octave bands Electrical equipment approval and safety evaluation Electrical appliances, coupling devices and accessories; Enclosures for electrical equipment; Laboratory and electromedical equipment; Effect of environmental exposure on electrical equipment and enclosures Cold; Damp heat; Dry heat; Humidity; Shock (impact); Solar radiation; Temperature; Vibration; AS IEC 60068:2003; AS IEC 60068.2.1; AS IEC 60068.2.2; AS IEC 60068.2.5; AS IEC 60068.2.27; AS IEC 60068.2.30; AS IEC 60068.2.64; Temperature in the range -40 to 60ºC only; Relative humidity in the range 5 to 97% RH only; Vibration - Broad-band random Evaluation of electrical appliances and devices - Energy efficiency classification Air conditioners; Clothes dryers; Dishwashers; Heat pumps; Liquid chilling devices; Refrigerators; Washing machines; Water heaters; Electrical energy consumption; Energy labelling and minimum energy performance standards (MEPS) evaluation; Standby power; AS/NZS 4474.2; AS/NZS 2007.2; AS/NZS 2040.2; AS/NZS 2442.2; AS/NZS 4692.2; AS/NZS 3823.2; AS/NZS 4776.2; Page 4/8 February 23, 2018

AS/NZS 4965.2; AS/NZS 4234; AS/NZS 62301 Evaluation of electrical appliances and devices - Performance Clothes dryers; Dishwashers; Freezers; Refrigerators; Washing machines; Water heaters; Air conditioners and heat pumps; Evaporative air conditioners; Air temperature; Cabinet and chamber volumes; Current; Cycle times; Drying effectiveness; Electrical voltage; Enamel thickness and imperfections; Evaporation efficiency; Ice making capability; Lining solubility; Liquid temperature; Load capacity; Power; Pull down time; Rinsing effectiveness; Strength and dimensions of components; Temperature control; Temperature distribution; Temperature limits in dryers; Vibration; Washing or soil removal; Water consumption; Water extraction effectiveness; Water pressure range; Whiteness retention; Condensate disposal; Dehumidifier capacity; Dehumidifying effectiveness; Enclosure sweat appraisal; Freeze up appraisal; Maximum operating efficiency; Sensible cooling effectiveness; Sensible AS/NZS 4474.1 ISO 8561 ISO 15502 IEC 62552 AS/NZS 2007.1 AS/NZS 2040.1 AS/NZS 2242.1 AS 1056.1 AS 3498 AS/NZS 4692.1 NZS 4602 NZS 4606 AS/NZS 60335.2.21 Air enthalpy method AS 2913 AS/NZS 3823.1.1 AS/NZS 3823.1.2 AS/NZS 3823.1.3 AS/NZS 3823.1.4 AS/NZS 3823.1.5 AS/NZS 3823.4.1 AS/NZS 3823.4.2 AS/NZS 3823.4.3 AS 3498 Section 7.2, Appendices A, B, C ; AS/NZS 60335.2.21: Clause 22.47 and Annex AA 22.47 Page 5/8 February 23, 2018

including liquid chilling packages heating effectiveness; Thermal capacity check; Total cooling effectiveness; Volumetric air flow rate; AS/NZS 4755.3.1 AS/NZS 4776.1.1 AS/NZS 4776.1.2 AS/NZS 4965.1 (Calorimeter and air enthalpy methods only); AS/NZS 5125.1 EN 14511-2 EN 14511-3 EN 14511-4 EN 14825 ISO 5151 ISO 13253 ISO 13256.1 ISO 15042 ISO 16358-1 ISO 16358-2 ISO 16358-3 GB/T 7725 GB 21455 AHRI 1160 (I-P) AHRI 1161 (SI) AHRI 1230 ANSI/AHRI 400 ANSI/AHRI 1360 (I-P) ANSI/AHRI 1361 (SI) ANSI/AHAM DH-1 Evaluation of gas appliances - Performance and safety Commercial gas cooking Cabinet temperature - appliances; Decorative gas Refrigerators; Carbon log and other fuel effect monoxide/carbon dioxide appliances; Direct gas-fired ratio; Drying performance - air heaters; Domestic gas Laundry dryers; Durability; cooking appliances; Emission; Flow rate - Domestic gas heating Components; Flue draft AS 2658 AS/NZS 5263.0 AG 101/AS 4551 and AS/NZS 5263.1.1 AG 102/AS 4552 and AS/NZS 5263.1.2 AG 103/AS 4553 and AS/NZS AS/NZS 1869 Hose and hose assemblies, Classes A- D only, excluding clause 2.4 - resistance to ozone Page 6/8 February 23, 2018

Evaluation of solar appliance and photovoltaic system performance Products and appliances connected to the water supply - Physical evaluation appliances; Domestic gas laundry dryers; Domestic gas refrigerators; Domestic outdoor gas barbeques; Flue cowls; Gas appliance hoses, hose components and hose assemblies; Gas pool heaters; Gas water heaters; LPG portable and mobile appliances; Pressure limit devices; Radiant gas heaters for outdoor and nonresidential indoor use; Regulators; Shut-off valves; Thermostats; Integrated energy storage systems; Solar panel systems; Combination washer/dryers; Dishwashers; Flow controllers; Sanitary fixtures - Urinals, water closet pan/suites, bidets, and spillage; Flue gas temperature; Gas leakage; Heat resistance; Ice making efficiency; Ignition and flame safeguard; Linting evaluation; Mechanical stability; Oven baking evenness; Radiant efficiency; Rain effects - Outdoor appliance; Safety shut down; Static pressure assessment; Temperature hazards; Temperature variation; Temperature variation assessment; Thermal efficiency; Turndown consumption; Vitiation effects; Voltage variation assessment; Wind generator evaluation - Outdoor and room sealed appliance; Effective thermal capacity; Flow rate in pumped collector loops; Incident angle modifier; Pressure drop across a collector; Sensible heat transfer; Steady-state efficiency; Time constant of a collector; Hydrostatic pressure; Rating of products for water efficiency; Torque; 5263.1.3 AG 104/AS 4554 AG 105/AS 4555 AG 106/AS 4556 AG 107/AS 4557 and AS/NZS 5263.1.7 AG 108/AS 4558 AG 110/AS 4560 AG 201/AS 4617 AG 214/AS 4629 AG 300/AS 4563 AS 4565 AG 604/AS 4566 AS/NZS 1869 Solar irradiance simulator AS/NZS 2535.1; AS/NZS 2712; AS/NZS 4234 (Flow rate in pumped collector units only); ISO 9806.1; ISO 9806.2; ISO 9806.3 AS/NZS 6400 ; AS/NZS 4692.1 ; AS 1056.1 AS/NZS 6400 (Sections 2.1, 2.2, 2.3, 2.4, 2.5, 2.6, 2.7, Tables 3.1 and 3.2 only) ; AS/NZS 4692.1 (Clauses 2.2.2 and 2.2.4 only) ; Page 7/8 February 23, 2018

Powered by TCPDF (www.tcpdf.org) National Association of Testing Authorities, Australia douche seats, cisterns and purpose built bathroom modules; Showers and shower modules; Tap assemblies; Water service products - Connectors, filters, fittings, hoses and pipes; AS 1056.1 (Clauses 2.7 and 2.9 only) Page 8/8 February 23, 2018