AC6/6H & AC8/8H Horizontal Metric Models

Similar documents
AC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY ELECTRICAL CONNECTIONS INSTALLATION

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

GP22/32 SERIES Sealed Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

SP22 Series Self-Priming Pumps. Assembly, Installation and Operation Manual

PREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS DB & SP SERIES

569, 570, 571, 572 Series

569, 570, 571, 572 Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

568X, 587X, 588X Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

LS-JRE OPERATION & INSTRUCTION MANUAL

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

Model 53 Macerator Pump Installation, Operation, Repair Manual

PENGUIN SERIES HSC PUMPS INTRODUCTION

STAINLESS STEEL UNITS

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

INSTRUCTION AND MAINTENANCE MANUAL: ORIGINAL INSTRUCTIONS FZX 2000 Series Pump

CR20-07 A-F-A-E-HQQE 3x400/ HZ

OWNERS GUIDE TO INSTALLATION AND OPERATION

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:

CR A-F-A-E-HQQE 3x400/ HZ

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Operating Instructions & Parts Manual Models 99533, 99532

Models: FM FM WARNING

LC Series - Light Commercial Pump Station Installation and Operation Manual

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Vertical Inline Models

CC Series VACUUM PUMPS

FLUSH WATER SAVER DUAL FLUSH KIT

INSTRUCTION AND REPAIR MANUAL

TITAN FLOW CONTROL, INC.

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

This label warns for risk of electrical shock when failing to observe.

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

QUICK PRIME INSTALLATION AND SERVICE MANUAL

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

52 SAN LUCAS CEILING FAN

Models Series Series

D1C HP Centrifugal Grinder Pump Installation & Service Manual with Parts List. Grinder Pump for Residential and Pressure Sewer Applications

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

QUICK PRIME INSTALLATION AND SERVICE MANUAL

IPT Series 2P5X, 2S5X, 2S5XC & 3S5X Pumps Refer to pump manual for General Operating and Safety Instructions.

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Mechanical seals external, single or double, to DIN EN 12756

Pressurized Filter Up to 1250 gallons

Mechanical Seal RG-4 stationary, double, liquid sealed

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

SuperKlean Washdown Products

E.2 series high efficiency circulator. Installation and operating instructions

55-Gallon Dispenser Package

Models Series Series

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

CL & CLG Clamp Mount Mixers

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

TP /4-A-F-A-BQQE 400D 50HZ

INSTRUCTION MANUAL HS-229G

MN908 No. 282C Replaces 282B LB7013

Audi-Larm Audible Alarm

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

ENERVEX RSV CHIMNEY FAN

Elite Primer Baldor Series External Pond Pump

Types TMUB, TMUAH and. J Jockey Pumps

52 CEILING FAN. Owner s Manual Models #50336, 50337

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

M Series Fan Filter Units

Installation and operating instructions. E.2 Series high efficiency circulator

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

LIMITED LIFETIME WARRANTY

Transcription:

AC6/6H & AC8/8H Horizontal Metric Models ASSEMBLY, INSTALLATION AND OPERATION MANUAL Part No. 108203

EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements as specified by the EU Directives listed. The product may not be taken into service until it has been established that the drive motor for the centrifugal pump complies with the provisions of all relevant EU Directives. The complete product complies with the provisions of the EC Directive on machinery safety provided motors carry CE marking. This declaration is valid provided that the devices are fully assembled and no modifications are made to these devices. Type of Device: Centrifugal Pumps Models: AC/AK/AV - 400/500/600/800 GP-11/22/32 VKC-5.5/6/6H/7/8/10 DB-3/4/5/5.5/6/6H/7/8/9/10/11/15/22 MSKC SP-10/11/15/22 KC-3/4/5/5.5/6/6H/8/10/11/22/32 MSVKC UC-1516/1516L/1518/1518L/2110/3158/326/326H/328/436/438/4310H/326H/4310H/6410 EU Directives: Machinery Safety (2006/42/EC) Applied Harmonized Standards: EN ISO 12100 EN 809 Manufacturer: Finish Thompson Inc. 921 Greengarden Road Erie, Pennsylvania 16501-1591 U.S.A Signed, President 1 August 2016 Person(s) Authorized to Compile Technical File: Finish Thompson GmbH Otto-Hahn-Strasse 16 Maintal, D-63477 DEU Telephone: 49 (0)6181-90878-0

EU Declaration of Conformity Manufactured by: Finish Thompson, Inc. 921 Greengarden Road Erie, Pennsylvania 16501 U.S.A. Phone: 1-(814)-455-4478 Fax 1-(814)-455-8518 Email: fti@finishthompson.com Web: www.finishthompson.com 1026 II 2GD Ex h IIC TX Gb Ex h IIIC TX Db FTZU 05 A127-05 This declaration applies to Finish Thompson AC Series pumps. Finish Thompson declares under our sole responsibility that the product listed above conforms to the relevant provisions of EU directive 2014/34/EU of 26 February 2014 for equipment and protective systems intended for use in potentially explosive atmospheres, and is certified for safe use in Atmosphere Group IIC/IIIC category 2 areas. This product has used the following harmonized standards to verify conformance: Non-electrical equipment for potentially explosive atmospheres: EN ISO 80079-36:2016 Basic Methods and Requirements. Non-electrical equipment intended for use in potentially explosive atmospheres: EN ISO 80079-37:2016 Protection by construction safety ch. and control of ignition source bh This product must not be used in areas other than specified above. If in doubt consult an authorized distributor, or refer to the manufacturer Finish Thompson. Approved by: Date: 5/5/2017

TABLE OF CONTENTS Description Page Number Model/Serial Number... 5 Important Notice... 5 Chemical Reaction Disclaimer... 5 Safety Precautions... 5-6 Capabilities... 6 Maximum Working Pressure & Temperature... 6 Solids... 6 Minimum Flow Rate... 6 Section 1 - Assembly... 7 Section II - Installation... 8 Section III - Start-up & Operation... 8-9 Start-up... 9 Shutdown... 9 Flush Systems... 9 Section IV - Maintenance... 9 Disassembly... 9 Reassembly... 10 AC6/AC6H Exploded View Diagram... 11 AC6/AC6H Parts List... 12 AC8/AC8H Exploded View Diagram... 12 AC8AC8H Parts List... 12 Section V - Troubleshooting... 13 Section VI - Warranty... 13 For factory assistance with repairs or maintenance, call 1-800-888-3743. FTI Contacts: Tech Service: 800-888-3743 or techservice@finishthompson.com Order Fax: 814-459-3460 or 814-455-8518 Sales: 814-455-4478; 800-934-9384 (U.S. & Canada)

Model Number and Serial Number Record the model number and serial number below for future reference. This is important information when ordering replacement parts or when technical assistance is required. The numbers are found on a label located on the motor adapter. MODEL NUMBER SERIAL NUMBER Chemical Reaction Disclaimer The user must exercise primary responsibility in selecting the products materials of construction, which are compatible with the fluid(s) that come(s) in contact with the product. The user may consult Finish Thompson, Inc. (manufacturer) and a manufacturer s representative/distributor agent to seek a recommendation of the products material of construction that offers the optimum available chemical compatibility. However neither manufacturer nor agent shall be liable for product damage or failure, injuries, or any other damage or loss arising out of a reaction, interaction or any chemical effect that occurs between the materials of the products construction and fluids that come into contact with the products components. Safety Precautions WARNING: READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND OPERATING THIS UNIT. FAILURE TO FOLLOW THESE PRECAUTIONS CAN RESULT IN SERIOUS INJURY OR DEATH. WARNING: Hot surfaces. This pump is capable of handling liquids with temperatures as high as 300 F (149 C). This may cause the outer areas of the pump to become hot as well and could cause burns. WARNING: Rotating Parts. This pump has components that rotate while in operation. Follow local safety standards for locking out the motor from the power supply during maintenance or service. WARNING: Chemical Hazard. This pump is used for transferring many types of potentially dangerous chemicals. Always wear protective clothing, eye protection and follow standard safety procedures when handling corrosive or personally harmful materials. Proper procedures should be followed for draining and decontaminating the pump before disassembly and inspection of the pump. There may be small quantities of chemicals present during inspection. WARNING: Never run pump at less than minimum flow or with the discharge valve closed. This could lead to pump failure. WARNING: The pump and associated components are heavy. Failure to properly support the pump during lifting and movement could result in serious injury or damage to the pump and components. CAUTION: This pump should never be started without liquid in the casing. IT CANNOT BE RUN DRY WITHOUT CAUSING DAMAGE TO THE PUMP. It is recommended that run dry protection be used. Optional electronic power monitors are available to help protect against run dry. CAUTION: Never start or operate with a closed suction valve. WARNING: Operation without priming or against a closed discharge valve can result in high temperatures that can result in injury or damage to pump components. CAUTION: Always provide adequate NPSHa (net positive suction head available). It is recommended to provide at least 2 feet (61 cm) above the NPSHr (net positive suction head required). CAUTION: If pump is used on variable speed drive, do not exceed the frequency for which the pump was designed (for example, if the pump is a 50 Hz model, do not exceed 50 Hz). 5

Safety Precautions for ATEX Pumps CAUTION: Proper o-ring material must be chosen for the fluid being pumped. Improper material selection could lead to swelling and be a possible source of leaks. This is the responsibility of the end user. WARNING: The pump must be checked for leaks on a regular basis. If leaks are noticed, the pump must be repaired or replaced immediately. WARNING: The pump must be cleaned on a regular basis to avoid dust buildup greater than 5 mm. WARNING: ATEX pumps must use a power monitor, flow switch, pressure switch or similar device to help protect against running dry or closed discharge valve. Any of these conditions could lead to a rise in surface temperature of the pump. WARNING: The surface temperature of AC6 & 8 Series pumps is completely dependent on operating conditions. Pump will transfer heat from the piping system, motor and fluid. These items must be considered as a system when assessing an ATEX application. WARNING: In the event of a motor bearing failure, the ceramic stationary seal face will protect the pump shaft from making metal on metal contact until the power monitor shuts the pump down. Pump must be fitted with a power monitor that will shut down the pump within 3 seconds of a motor bearing failure. AC6 & 8 Capabilities Maximum Working Pressure: AC6-100psi (6.9 bar) AC8-120psi (8.3 bar) Maximum Temperature: 300 F (149 C) NOTE: Maximum temperature is application dependent. Consult a chemical resistance guide or the chemical manufacturer for chemical compatibility and temperature limits. Solids: Maximum particle size is 100 microns for slurries and 1/64 (0.4 mm) for occasional solids. Maximum hardness is 80 HS. Maximum concentration is 10% by weight. NOTE: If solids are being pumped, it is recommended that the pump have a Silicon Carbide mechanical seal. Pumping solids may lead to increased wear. Minimum Allowable Flow Rate: AC6 = 10 gpm (2.3 m 3 /hr) AC6H = 3 gpm (0.7 m 3 /hr) AC8 = 20 gpm (4.5 m 3 /hr) AC8H = 5 gpm (1.1 m 3 /hr) 6

AC6 & 8 Assembly, Installation and Operation Unpacking and Inspection Unpack the pump and examine for any signs of shipping damage. If damage is detected, save the packaging and notify the carrier immediately. Section I - Assembly Tools Required: Metric box wrench set & metric deep well socket set - Pumps with Motors 1. No assembly required. Unpack the pump and motor and examine for any signs of shipping damage. If damage is detected, save the packaging and notify the carrier immediately. 2. Proceed to the Installation section of these instructions. - Pumps without Motors - 90, 100/112, 132 & 160 frame with B5 flange: All motors must have motor feet. Very Important: Do not remove shipping plug located in suction port of the pump until the pump is completely assembled onto the motor. Note: B5 flange motors require customer supplied hardware 1. Unpack the pump and examine for any signs of shipping damage. If damage is detected, save the packaging and notify the carrier immediately. 2. Insert key into motor keyway. (See Figure 1). Visually determine key location in pump end. Align keyway slots on motor shaft and pump impeller sleeve. Slide pump assembly over the motor shaft until the pump motor adapter (item 8 for AC6 or 22 for AC8) is completely seated over the motor rabbet. Install 4 bolts with flat washers and lock washers (items 9, 10 & 11 for AC6 or 19, 20 & 21 for AC8) through the face of the motor & into the motor adapter. Securely tighten bolts using the torque specifications in the table below. 3. Lubricate o-ring of self-sealing bolt (item 6) with suitable, compatible lubricant. Insert self-sealing bolt through shipping plug and into the eye of the impeller using a deep well socket. Insert a screwdriver into the motor fan to prevent motor shaft from rotating. Securely tighten bolt using the torque specifications in the table below. 4. Remove the shipping plug from the suction port. 5. Rotate the motor fan by hand and check for impeller rubbing. If the impeller rubs, verify that the self-sealing bolt is properly installed. 6. Proceed to the Installation section of these instructions. Flange hole thread size: Motor Frame 90 B5 = M10 x 1.5 Motor Frame 100/112/132 B5 = M12 x 1.75 Motor Frame 160 B5 = M18 x 2.5 Torque bolts to the following: Motor Frame 90 frame B5 (M10) = 240 in-lb (27.1 N-m) Motor Frame 100/112/132 B5 (M12) = 480 in-lb (54.3 N-m) Torque impeller bolt to the following: Motor Frame 90 frame B5 (M8) = 130 in-lb (14.7 N-m) Motor Frame 100/112 B5 (M10) = 240 in-lb (27.1 N-m) Motor Frame 132 B5 (M12) = 480 in-lb (54.3 N-m) Motor Frame 160 B5 (M16) = 118 ft-lb (160.3 N-m) Fig 1 7

Section II - Installation Pump motor base should be securely fastened to a solid foundation. CAUTION: The NPSH available to the pump must be greater than the NPSH required. NPSH available should be two feet (.6 meters) greater than NPSH required. Install the pump as close to the suction source as possible. Support the piping independently near the pump to eliminate any strain on the pump casing. In addition, the piping should be aligned to avoid placing stress on the pump casing. The suction side of the pump should be as straight and short as possible to minimize pipe friction. The suction line should not have any high spots. This can create air pockets that can reduce pump performance. The suction piping should be level or slope slightly upward to the pump. If flexible hose is preferred over pipe, use a reinforced hose rated for the proper temperature, pressure and is chemically resistant against the fluid being pumped. The suction valve must be completely open to avoid restricting the suction flow. When installing pumps with flanges, we recommend use of low seating stress gaskets such as Gore-Tex or Gylon (expanded PTFE). Motor/Electrical Install the motor according to NEC requirements and local electrical codes. The motor should have an overload protection circuit. Wire the motor for clockwise rotation when facing the fan end of the motor. CAUTION: Do not operate the pump to check rotation until the pump is full of liquid. Check all electrical connections with the wiring diagram on the motor. Make sure the voltage, frequency, phase and amp draw comply with the supply circuit. To verify correct rotation of the motor: 1. Install the pump into the system. 2. Fully open the suction and discharge valves. 3. Allow fluid to flow into the pump. Do not allow the pump to run dry. 4. Jog the motor (allow it to run for 1-2 seconds) and observe the rotation of the motor fan. Refer to the directional arrow label on pump housing if necessary. NOTE: A pump running backwards will pump but at a greatly reduced flow and pressure. Section III - Start-up and Operation CAUTION: Do not run the pump dry. This pump should never be started without liquid in the casing. The fluid being transferred by the pump lubricates the pump components. Even short periods of running the pump dry could damage the pump. It is recommended that run dry protection is used. Optional electronic power monitors are available to help protect against run dry. 1. This pump must be filled from a flooded suction tank (gravity) or primed with liquid from an outside source. The AC6 & 8 pumps are not self-priming. 2. Open the inlet (suction) and discharge valves completely and allow the pump to fill with liquid. 3. Close the discharge valve. 4. Turn the pump on. Slowly open the discharge valve. Adjust the flow rate and pressure by regulating the discharge valve. Do not attempt to adjust the flow with the suction valve. Shutdown 1. Use the following procedure to shutdown the pump. 2. Slowly close the discharge valve. 3. Turn off the motor. 4. Close the suction valve. 8

Flush Systems CAUTION: Some fluids react with water; use compatible flushing fluid. 1. Turn off the pump. 2. Completely close the suction and discharge valves 3. Connect flushing fluid supply to flush inlet valve. 4. Connect flushing fluid drain to flush drain valve. 5. Open flushing inlet and outlet valves. Flush system until the pump is clean. Section IV Maintenance Recommended maintenance schedule The recommended maintenance schedule depends upon the nature of the fluid being pumped and the specific application. If the pump is used on a clean fluid, it is recommended that the pump be removed from service and examined after six months of operation or after 2,000 hours of operation. If the pump is used on fluids with solids, high temperatures or other items that could cause accelerated wear, then this initial examination should be sooner. After the initial examination of the internal components and wear items are measured, a specific maintenance schedule can be determined. For best results, it is recommended that the pump be removed from service annually for examination. Disassembly WARNING: Rotating Parts. This pump has components that rotate while in operation. Follow local safety standards for locking out the motor from the power supply during maintenance or service. WARNING: Chemical Hazard. This pump is used for transferring many types of potentially dangerous chemicals. Always wear protective clothing, eye protection and follow standard safety procedures when handling corrosive or personally harmful materials. Proper procedures should be followed for draining and decontaminating the pump before disassembly and inspection of the pump. There may be small quantities of chemicals present during inspection. WARNING: Stop the pump, lock out the motor starter, close all the valves that are connected to the pump, and drain/decontaminate the pump. WARNING: The pump must be thoroughly flushed of any hazardous materials and all internal pressure relieved prior to opening the pump. Allow the pump to reach ambient temperatures prior to performing maintenance. Seal Replacement & Disassembly 1. Disconnect power. Remove electrical wiring. 2. Close the suction and the discharge valves. Disconnect the piping. Remove any mounting bolts. 3. For AC6 pumps - Remove the v-clamp (item 2) and the impeller housing (item 1), first apply a thread lubricant to the threaded rod portion of the v-clamp then remove the nut. Remove the v-clamp, the housing, and the o-ring (item 3). For AC8 pumps - Remove the 8 housing bolts and all the hardware (items 15, 16, 17, 18). Remove the impeller housing (item 1) and the o-ring (item 3). 4. Place a screwdriver in the motor fan to prevent rotation and remove the self-sealing bolt (item 6). Note: Do not reuse the self-sealing bolt. 5. Remove impeller (item 4), rotating seal component, seal spring and seal spring retainer. Discard seal components after removal. (See Figure 2). 6. Remove back head assembly (item 7) and press out the stationary seal component. Discard stationary seal component after removal. Fig 2 9

Reassembly 1. Lubricate the rubber portion of the new stationary seal (item 5) with P-80 (or equivalent) or use soapy water. Do not use petroleum products to lubricate the rubber. Note: Keep the polished surface of the seal face clean. Use a piece of cardboard to protect the seal while pressing against the stationary face. 2. Press the stationary seal into the seal seat of the back head assembly so that the seal surface points away from the motor face. Place the back head into the motor adapter. 3. Place the spring retainer and seal spring onto the impeller sleeve. 4. Lubricate the inside diameter of the rotating seal component with P-80 (or equivalent) or soapy water and press it over the impeller sleeve (item 4) with the rotating face pointed away from the impeller as shown in Figure 2 (towards the stationary face). 5. Insert key into the motor keyway. Visually determine key location in impeller sleeve. Align keyway slots on motor shaft and impeller sleeve. Slide impeller assembly over the motor shaft. Lubricate o-ring of new self-sealing bolt (item 6) with suitable, compatible lubricant. Insert self-sealing bolt into the eye of the impeller using a deep well socket. Insert a screwdriver into the motor fan to prevent motor shaft from rotating. Tighten the bolt to 12-ft lbs. 6. Place impeller housing (item 1) over back head (item 7) and o-ring (item 3) and make sure discharge is in the correct orientation (usually 12 o clock). 7. For AC6 pumps - Place the v-clamp (item 2) over the impeller housing, back head, and the mounting plate (item 14). Make sure the discharge is level and in the correct orientation. (See Figure 3). Tighten the nut on the v-clamp. Firmly tap the v-clamp with a mallet in several spots, and then retighten the nut. For AC8 pumps - Insert the mounting bolts with flat washer (items 15 &16) through the impeller housing (item 1), the back head (item 7), and the mounting plate (item 14), and tighten with the correct hardware (items 15, 17, & 18). Fig 3 8. Rotate the motor fan by hand and check for impeller rubbing. If the impeller rubs, verify that the self-sealing bolt is properly installed. 9. Reinstall the pump into the system. 10

AC6/AC6H Exploded View AC6-AC6H Spare Parts Item Description Part No. 1 2 3 4 5 6 7 8 9 10 11 12 13 Impeller Housing AC6SJS - 1-1/2" x 1-1/4" FBSP A102184-3 AC6SJS - 2" X 1-1/2" FBSP A102184-4 AC6HJS - 1-1/4" x 3/4" FBSP A102232-1 AC6SJS - 1-1/2" x 1-1/4" FNPT A102184-1 AC6SJS - 2" X 1-1/2" FNPT A102184-2 AC6HJS - 1-1/4" x 3/4" FNPT A102232 V Clamp 304 stainless steel J103090 Housing O-Ring FKM J103084 EPDM J103085 PTFE encapsulated silicone J103257 Impeller 316 Stainless Steel 5.25" Standard w/ IEC 90 B5 (AC6) 106185-2 5.75" Standard w/ IEC 90 B5 (AC6) 106185-1 6.00" Standard w/ IEC 90 B5 (AC6) 106185 5.25" Standard w/ IEC 100/112 B5 (AC6) 105981-2 5.75" Standard w/ IEC 100/112 B5 (AC6) 105981-1 6.00" Standard w/ IEC 100/112 B5 (AC6) 105981 6.25" High Head w/ IEC 90 B5 (AC6H) A102735-4 Mechanical Seal (Not Shown) See AC6 Seal Options Table on this page Impeller Bolt w/ O-ring with FKM for AC6/AC6H IEC 90 B5 107885 with EPDM for AC6/AC6H IEC 90 B5 107886 with PTFE for AC6/AC6H IEC 90 B5 107887 with FKM for AC6 IEC 100/112 B5 107251 with EPDM for AC6 IEC 100/112 B5 107252 with PTFE for AC6 IEC 100/112 B5 107268 Backhead IEC 90 B5 316 stainless steel A102677-3 IEC 100/112 B5 316 stainless steel A102677-4 Cast Iron Motor Adapter AC6SJS 106184 AC6HJS 106022 Hex Head Cap Screw (4 req'd.) Customer to supply - Lock Washer (4 req'd.) Customer to supply - Flat Washer (4 req d) Customer to supply - Socket Head Cap Screw (4 req d) 1/4 stainless steel J103396 Lock Washer (4 req d) 1/4 stainless steel J100672 AC6-AC6H Spare Parts - cont. Item Description Part No. 14 Mounting Plate IEC 90 B5 J103389-2 IEC 100/112 B5 105993 AC6-AC6H Mechanical Seal Options Option Part Seals for 90 Frame Only Number Rotating Face Stationary Face Elastomer D01 J103556 Carbon Ceramic FKM D02 J103557 Carbon Ceramic EPDM D04 J103560 Carbon Ceramic Kalrez D05 J103558 Silicon Carbide Silicon Carbide FKM D06 J103559 Silicon Carbide Silicon Carbide EPDM Option Part Seals for 100/112 Frame Only Number Rotating Face Stationary Face Elastomer D01 105995 Carbon Ceramic FKM D02 106395 Carbon Ceramic EPDM D05 107940 Silicon Carbide Silicon Carbide FKM 11

AC8/AC8H Exploded View AC8-AC8H Spare Parts Item Description Part No. Impeller Housing AC8HJS - 1-1/4" x 3/4" FBSP A102528-1 AC8SJS - 2" x 1-1/2" FBSP A102747-4 1 AC8SJS - 2-1/2" x 2" FBSP A102747-3 AC8HJS - 1-1/4" x 3/4" FNPT A102528 AC8SJS - 2" x 1-1/2" FNPT A102747-1 AC8SJS - 2-1/2" x 2" FNPT A102747-2 Housing O-Ring 3 FKM J103087 EPDM J103088 PTFE encapsulated silicone J103258 Impeller 316 Stainless Steel 6.25" High Head (AC8H) 107164 7.00" High Head (AC8H) 107164-1 8.00" High Head (AC8H) 107164-2 6.50" Standard (AC8 IEC 100/112 B5) 108046-1 7.00" Standard (AC8 IEC 100/112 B5) 108046 7.50" Standard (AC8 IEC 100/112 B5) 108046-2 8.00" Standard (AC8 IEC 100/112 B5) 108046-3 6.50" Standard (AC8 IEC 132 B5) 105340-1 7.00" Standard (AC8 IEC 132 B5) 105340-3 4 7.50" Standard (AC8 IEC 132 B5) 105340-2 8.00" Standard (AC8 IEC 132 B5) 105340-4 6.50" Standard (AC8 IEC 160 B5) 107096-2 7.00" Standard (AC8 IEC 160 B5) 107096-3 7.50" Standard (AC8 IEC 160 B5) 107096-4 8.00" Standard (AC8 IEC 160 B5) 107096-5 6.50" Standard (AC8 high flow IEC 100/112 B5) 108046-4 7.00" Standard (AC8 high flow IEC 100/112 B5) 108046-5 6.50" Standard (AC8 high flow IEC 132 B5) 105340 7.00" Standard (AC8 high flow IEC 132 B5) 105340-5 6.50" Standard (AC8 high flow IEC 160 B5) 107096-1 7.00" Standard (AC8 high flow IEC 160 B5) 107096 5 Mechanical Seal (Not Shown) See AC8 Seal Options Table on this page Impeller Bolt w/ O-ring with FKM for AC8/AC8H IEC 100/112 B5 107259 with EPDM for AC8/AC8H IEC 100/112 B5 107260 with PTFE for AC8/AC8H IEC 100/112 B5 108047-1 6 with FKM for AC8 IEC 132 B5 107253 with EPDM for AC8 IEC 132 B5 107254 with PTFE for AC8 IEC 132 B5 107272 with FKM for AC8 IEC 160 B5 107257 with EPDM for AC8 IEC 160 B5 107258 with PTFE for AC8 IEC 160 B5 Contact FTI Backhead 316 Stainless Stell 7 AC8H IEC 100/112 B5 A102677-5 AC8 IEC 100/112 & 132 B5 105336 AC8 IEC 160 B5 107092 12 AC8-AC8H Spare Parts Item Description Part No. Motor Adapter AC8H IEC 100/112 B5 - painted steel 107166 8 AC8 IEC 100/112 B5 - painted steel 108041 AC8 IEC 132 B5 - painted steel 105333 AC8 IEC 160 B5 - painted cast iron 107089 9 Hex Head Cap Screw (4 req'd.) IEC 160 B5* J103782 10 Lock Washer (4 req'd.) IEC 160 B5* J101023 11 Flat Washer (4 req d) IEC 160 B5* J101360 12 Socket Head Cap Screw (8 req d) 1/4 stainless steel J100320 13 Lock Washer (8 req d) 1/4 stainless steel J100672 14 Mounting Plate IEC 100/112, 132, & 160 B5 J103857 15 Flat Washer (16 req d) 3/8 stainless steel J100128 16 Hex Head Cap Screw (8 req d) 3/8x1 stainless steel J100114 17 Lock Washers (8 req d) 3/8 stainless steel J100115 18 Hex Nut (8 req d) 3/8 stainless steel J100135 19 Lock Washer (4 req'd.) Customer to supply - 20 Hex Head Cap Screw (4 req'd.) Customer to supply - 21 Flat Washer (4 req d) Customer to supply - 22 Motor Adapter Flange IEC 160 B5 only - painted steel 107088 *Customer responsible for supplying this hardware for all other frame sizes. AC8 Mechanical Seal Options Option Part AC8H Seals for 100/112 Frame Only Number Rotating Face Stationary Face Elastomer D01 105995 Carbon Ceramic FKM D02 106395 Carbon Ceramic EPDM D05 107940 Silicon Carbide Silicon Carbide FKM Option Part AC8 Seals for 100/112 & 132 Frame Number Rotating Face Stationary Face Elastomer D01 105339 Carbon Ceramic FKM D02 106518 Carbon Ceramic EPDM D04 105605 Carbon Ceramic Kalrez Option Part AC8 Seals for 160 Frame Only Number Rotating Face Stationary Face Elastomer D01 107152 Carbon Ceramic FKM D02 107153 Carbon Ceramic EPDM

Section V - Troubleshooting General Notes: Contact our Technical Service Department If you have any questions regarding product operation or repair: Phone: 1-800-888-3743 E-mail: techservice@finishthompson.com. No or Insufficient Discharge Air leaks in suction piping Pump not primed System head higher than anticipated Closed valve Viscosity or specific gravity too high Suction lift too high or insufficient NPSH Clogged suction line or impeller vanes Motor rotation incorrect (correct rotation when viewed from the fan end is clockwise) Insufficient Pressure Air or gas in liquid Impeller diameter too small System head lower than anticipated Motors speed insufficient (too low) or motor rotation incorrect (correct rotation when viewed from the fan end is clockwise) Loss of Prime Leak in suction piping Foot valve or suction opening not submerged enough Foot valve too small or leaking Air or gas in liquid Foreign matter in impeller Leaking valve. Suction lift too high or insufficient NPSHa. Excessive Power Consumption Head lower than rating Excessive flow Specific gravity or viscosity too high. Section VI - Warranty Finish Thompson, Inc (manufacturer) warrants this pump product to be free of defects in materials and workmanship for a period of one year from date of purchase by original purchaser. If a warranted defect, which is determined by manufacturer s inspection, occurs within this period, it will be repaired or replaced at the manufacturer s option, provided (1) the product is submitted with proof of purchase date and (2) transportation charges are prepaid to the manufacturer. Liability under this warranty is expressly limited to repairing or replacing the product or parts thereof and is in lieu of any other warranties, either expressed or implied. This warranty does apply only to normal wear of the product or components. This warranty does not apply to products or parts broken due to, in whole or in part, accident, overload, abuse, chemical attack, tampering, or alteration. The warranty does not apply to any other equipment used or purchased in combination with this product. The manufacturer accepts no responsibility for product damage or personal injuries sustained when the product is modified in any way. If this warranty does not apply, the purchaser shall bear all cost for labor, material and transportation. Manufacturer shall not be liable for incidental or consequential damages including, but not limited to process down time, transportation costs, costs associated with replacement or substitution products, labor costs, product installation or removal costs, or loss of profit. In any and all events, manufacturer s liability shall not exceed the purchase price of the product and/or accessories. Warranty Registration Thank you for your purchase of this quality Finish Thompson product. Be sure to take a minute to register your pump at Finishthompson.com/warranty. Simply provide the model number, serial number and a few other pieces of information. Ordering Spare Parts Spare parts can be ordered from your local distributor. Always refer to the pump model to avoid error. Vibration/Noise Pump cavitating from improper suction or feed Motor or piping not properly secured Foreign object in impeller 13

Part No. 108203, Rev.2, 5/10/2017