Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Similar documents
Purge Ventilation Unit. Product Manual. ventilation systems TP625

Warnings, Safety Information and Guidance

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Lo-Carbon Quadra Centrifugal Fan

Silhouette Installation and Wiring Instructions

aura-t TP536/GBR ventilation systems

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Heat Recovery Ventilation Units. LED Status Indicator. Product Manual. ventilation systems. auralite compatible HRV units

G Installation manual Solitude - dmev unit

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

aura-t TP536/EU ventilation systems

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Centrif Duo & Centrif Duo Plus

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon SELV Tempra

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

HRV10 Q Plus TP440A TP440ABD TP440ABS. HRV10M Q Plus TP441A TP441ABD TP441ABS. Heat Recovery Ventilation Unit Product Manual

Lo-Carbon Quadra SELV

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Installation & Operating Instructions

HR200WK Through the wall Heat Recovery Ventilator

WHHR Midi & Midi Lite

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Xpelair Simply Silent TM Contour Fan

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

Installation & Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

CG60/ 70/ 80/ 90/ 100 SS/BK

18 INCH HIGH VELOCITY FLOOR FAN

Xpelair Simply Silent TM DX100 Fan

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Simply Silent Contour 4 (100mm) Axial Extraction Fan

User and maintenance manual

Section HMB/HMBE. Section B/BE. Heat Recovery Ventilation Units. LED Status Indicator. Product Manual. ventilation systems

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Lo-Carbon PoziDry Pro

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Xpelair Simply Silent DX150

ART cm Island Curved Glass

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

Xcell 270 Longlife DC wholehouse heat recovery unit

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

200W Frostwatch Radiant Heater Operation Manual

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

Xpelair Simply Silent DX100

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

100cm Chimney Hood GB IE

KADO LUX LED EXHAUST FAN 200

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

5KW ELECTRIC FAN HEATER

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

Installation and Maintenance

VENT TREX. Product Guide

Xpelair Simply Silent DX100B

HOTLINE:

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

Installation and Maintenance

GB User and maintenance manual

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

Lucci Designer Hi Flow Exhaust Fan

Installation and Maintenance

EVP61/91/101/121. Extractor. Installation, use and maintenance.

USER MANUAL DOWN-DRAFT HOOD. UBDDCHC60_90A, UBDDCHC60_90ABK Version 02

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance.

3KW ELECTRIC FAN HEATER

15KW ELECTRIC FAN HEATER

D100, D125 & D150. Installation Instructions

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Installation and Maintenance

2 KW OIL FILLED RADIATOR

30KW ELECTRIC FAN HEATER

ISCG90SS _03 ISCG90SS

Hand Dryer Installation & User Manual

Installation and Maintenance

Installation and Operating Manual Drying Cabinet

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

User Instruction Manual

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A

irconcentre.co.uk airooncentre.co.uk

Wiring the fan correctly...

Instructions for use

EDD61 & EDD91 Extractors

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Transcription:

EN Trimbox Mixed Flow Fans TP220T TP221T TP222T TP223T Product Manual ventilation systems

Safety Information Important Information Important: read these instructions fully before the installation of this appliance 1. Installation of the appliance and accessories must be carried out by a qualified and suitable competent person and be carried out in clean, dry conditions where dust and humidity are at minimal levels. 2. This manual covers the installation of the Titon In-Line Fans 3. All wiring must conform to current I.E.E. Wiring Regulations and all applicable standards and Building Regulations. 4. The units must be connected to a local three pole isolation switch with a contact separation of at least 3mm. 5. The units are suitable for 230V ~ 50/60Hz single phase suppy. 6. The units are DOUBLE INSULATED and marked with symbol. There are no Earth terminals and these units MUST NOT BE EARTHED. 7. Ensure cable clamp is used and fully tightened. 8. Cable entry must be made using the grommet supplied. 9. The unit must be stored in a clean and dry environment. 10. Do not install the appliance in areas where the following may be present or occur; Excessive oil or a grease laden atmosphere, Corrosive or flammable gases, liquids or vapours, Ambient temperatures above 50 C or below 0 C, Obstructions which would hinder access to the fan unit. Ducting bends or duct transformations close to the fan unit. Humidity levels above 90% or is a wet environment. 2

11. The appliance is not suitable for installation to the exterior of the dwelling. 12. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 13. The unit must not be connected to a tumble dryer or a cooker hood. 14. Precautions must be taken to avoid the back-flow of gases into the room from an open flue appliance. 15. Ensure impellor rotates and is free from obsructions and debris before conneting ducting. 16. Ensure all ducting associated pipe work is free from debris and blockages before switching on the unit. Important environment information about this product. This symbol on this unit or package, indicates that disposal of this unit after its life cycle could harm the environment. Do not dispose the unit as municipal waste; it should be disposed by a specialized company for recycling. This unit should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt contact your local authorities about waste disposal rules. 3

Explanation of symbols on the appliance. Read instruction Manual. Risk of Electric Shock. Isolate from the mains power supply before removing the cover. + Contains rotating mechanical parts. Following isolation from the mains power supply allow sufficient time for all moving parts to stop before removing any ducting. Airflow Direction 4

Contents Safety Information Important Information 2 Explanation of symbols on the appliance. 4 Product Information Product Features 6 Packaging Contents 6 Dimensions 7 Component Identification 8 Fixing 8 Ducting 9 Wiring 10 Commissioning 11 Overrun Timer 11 Speed Setup 12 Product Fiche 13 Maintenance Routine Maintenance 15 Cleaning 15 Faults 15 When this document is viewed as a PDF the headings & sub headings on this page are hyper links to the content. 5

Product Information Titon In-Line Fans are designed to extract humid & stale air and expel it to the exterior. They are also suitable for extracting air from one room and expelling it to another room. The fan unit is usually fitted in the ceiling void, well away from the inlet. This In-Line feature allows the inlet grille to be mounted in wet areas (eg near the splash zones of bathrooms) or even above a shower. As the unit is in the ceiling cavity (away from the inlet grille), noise from the fan is minimized Product Features Three speed Low, Medium & High. Overun timer, 3-30 minutes. Part Number TP220T TP221T TP222T TP223T Duct Diameter ID Ø100mm Ø125mm Ø150mm Ø160mm Supply Voltage 220-240V~ 50Hz Power Rating 30W 60W Supply Voltage 220-240V~ 60Hz Power Rating 38W 84W Fuse Rating 3A Protection Class Class II IP Rating IP55 Weight 1.9Kg 2.0Kg 3.0Kg 3.1Kg Packaging Contents Inspect the unit when taking delivery. Check the unit for damage and that all accessories have been supplied. Package supplied with; In-Line Fan Unit x 1. Product Manual x 1. Any shortages or damage must be immediately reported to the supplier. 6

Dimensions The diagram details the overall size of the unit. Installer must allow additional space around the unit to allow for future servicing and maintenance. Part Number TP220T TP221T TP222T TP223T Duct Diameter ID Ø100mm Ø125mm Ø150mm Ø160mm Dimensions mm ØA 98 123 148 158 ØB 173 200 C 111 131 D 295 269 289 271 E 100 110 F 195 231 G Fixing Centres 135 136 H Fixing Centres 176 214 7

Component Identification Terminal Box Gromet INLET Fixing Holes Impellor Fixing The units are designed as in-line duct fans to be fitted between two duct runs. 1. Choose a suitable mounting location for the inlet grille. Ensure there is adequate clearance for the ducting. 2. Choose a suitable location for the extract grille ensuring there is adequate clearance for the ducting. 3. Choose a suitable mounting location for the fan unit. Ensure that a power outlet is installed near the intended location of the unit. 4. The fan unit must be positioned at the highest point on the system so the ducting will slope downwards to both grilles. 5. The airlfow direction is marked on the rating label. 6. Do not cover the fan unit with thermal insulation. Keep at least 100mm clearance between the unit and any thermal insulation. 7. Mount the unit to a support using suitable fixings through the four fixing holes. 8

8. The unit should be positioned so that the power cord is pointing downwards. 9. Orientation of the junction box can be adjusted to suit the fan units location 10. Unscrew and open the clamps. 11. Rotate the motor unit to the desired position. 12. Replace the clamps and tighten the screws. 13. The duct must not be installed vertically into a roof terminal - the product is not designed or intended for this type of installation. Ducting 1. Titon recommend using rigid ducting, any flexible ducting used should be fully extended. 2. All ducting joints must be fixed using a method that ensures a long term seal is achieved. 9

Wiring 1. Access to the wiring terminals is via the terminal box on top of the unit. 220-240V~ TP 2xxT 50/60Hz N Ls L N L 10

Commissioning Overrun Timer The Overrun Timer is factory set to approximately 3 minutes. The Overrun Timer can be set between 3 and 30 minutes. Access to Overtime Timer Control is via the terminal box on top of the unit. WARNING: Unit uses a 220-240V~ supply and contains rotating mechanical parts. ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop before Commissioning. Adjust the Overrun Timer Control on the PCB with using a small flat bladed screwdriver. Clockwise Increase. Counter clockwise Decrease.. 11

Speed Setup Access to Speed Selection is via the terminal box on top of the unit. WARNING: Unit uses a 220-240V~ supply and contains rotating mechanical parts. ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop before Commissioning. The Titon Mixed Flow Fans runs at one of 3 speeds; 1. Low [L]; 2. Medium [M]; 3. High [H]. The factory default is Medium. To change the speed of the fan; disconnect the wire and reconnect to the terminal corresponding to the desired speed. 12

Documentation Product Fiche Supplier Name Supplier Address Titon 894 The Crescent Colchester Business Park Colchester Essex CO4 9YQ Model Ø100mm Trimbox Ø125mm Trimbox Mixed Flow In-line fan Mixed Flow In-line fan Model Identifier TP220T TP221T Declared Typology NRVU - UVU NRVU - UVU Type of Drive installed Multi-speed drive Multi-speed drive Type of heat recovery system none none Thermal efficiency of heat recovery not applicable not applicable Nominal NRVU Flow Rate (m3/s) 0.083 0.083 Effective power input (kw) 0.03 0.03 SFPint W/(m3/s) n/a n/a Face velocity in m/s n/a n/a Nominal external pressure in Pa 85 85 Internal pressure drop in Pa n/a n/a Static efficiency of fan in accordance with (EU) No 327/2011 22% - < 125W motor 22% - < 125W motor Declared maximum internal leakage rate (%) n/a n/a Energy performance of the filters n/a n/a Filter Warning (RVU) n/a n/a 13

Model Ø150mm Trimbox Ø160mm Trimbox Mixed Flow In-line fan Mixed Flow In-line fan Model Identifier TP222T TP223T Declared Typology NRVU - UVU NRVU - UVU Type of Drive installed Multi-speed drive Multi-speed drive Type of heat recovery system none none Thermal efficiency of heat recovery not applicable not applicable Nominal NRVU Flow Rate (m3/s) 0.138 0.138 Effective power input (kw) 0.06 0.06 SFPint W/(m3/s) n/a n/a Face velocity in m/s n/a n/a Nominal external pressure in Pa 150 150 Internal pressure drop in Pa n/a n/a Static efficiency of fan in accordance with (EU) No 327/2011 33% - < 125W motor 33% - < 125W motor Declared maximum internal leakage rate (%) n/a n/a Energy performance of the filters n/a n/a Filter Warning (RVU) n/a n/a Internet address (for dissassembly instructions) www.titon.co.uk 14

Maintenance Routine Maintenance WARNING: The unit uses a 220-240V~ supply and contains rotating mechanical parts. ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop before undergoing any Servicing or Maintenance. All ventilation units require periodic maintenance, units should be inspected and cleaned. Routine maintenance must only be carried out by a suitably qualified and competent person. Cleaning This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used. In the event of any queries please contact the system installer. Faults This product contains no serviceable parts and no attempt should be made to repair it. If the product is faulty it should be discarded. 15

In the event of any queries please contact the system installer. Ensure this booklet is passed to the householder once installation & commissioning of the ventilation system is complete. This Product Manual must be kept in the Home Information Pack and used as a service record. Installed by: MARKETING DIVISION 894 The Crescent, Colchester Business Park, Colchester, CO4 9YQ Tel: +44 (0) 1206 713800 Fax: +44 (0) 1206 543126 Email: ventsales@titon.co.uk Web: www.titon.com 2018 TITON DO 5581 Iss 02