VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

Similar documents
VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

PERSONAL COMBUSTIBLE GAS DETECTOR

Safe Operation Manual. Honeywell IQ Force Gas Detector

Instruction Manual Model GX-82 Portable Three Gas Monitor

NJSP HMRU. Module 5 B HM Operations 1

Instruction Manual Model GX-86 Portable Four Gas Monitor

INSTRUCTION MANUAL MODEL GX-82A

Dräger X-am 7000 Multi-Gas Detection

GAS DETECTORS EXPLOSIMETERS/CATHAROMETERS EX 2000/EX 2000 C/GD 2000/GDP Your environment, your safety, let s master them together

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detection

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

T.ex Single Gas Detector VISA

INSTRUCTION MANUAL MODEL GX-82A

IMR IX176 Portable Gas Detector User Manual

For the Safety of Your

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

GasAlertMicroClip X3 Specifications

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detection

Model GX-2001 Canadian Version Operator s Manual Part Number: RK Revision: 0 Released: 1/17/05

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

(Vendor Signature) By Mail: Mark sealed proposal with Bid/Proposal No.2014'33' Vendor Contact I nformation :

Portable type of Carbon Dioxide Detector Model: GT220

Reference Manual. MultiPro Gas Detector

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Reference Manual MultiPro Gas Detector

CO warning instruments and gas spillage detectors

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

Monitores Personales. Personal Monitor

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Choosing the best confined space gas detector

WATCHMAN MULTIGAS MONITOR

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

E1000 Portable gas detector

ALTAIR 5X Multigas Detector Product Specification

Toxi Vision IR CH 4. Single Gas Detector. Reference Manual

Reference Manual. MultiVision Gas Detector

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

QD6310. Fixed Gas Detector Operation Manual

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

IMR EX610. Portable Gas Detector. Operation Manual

GX-2009 Portable Gas Monitor Operator s Manual

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

RLD-H10P Refrigerant Leak Detector

GfG s EXOTECTOR has been tested for EX-protection by DMT (BVS) Dortmund

Portable Gas Detector Instruction Manual

Dräger X-am 7000 Multi-Gas Detection

EST User Manual. (Please read this manual carefully before using)

We measure it. testo 316-Ex CH 4 testo 316-1

Dräger X-am 5000 Multi-Gas Detector

Bristol Babcock Oil Content Monitor "oil in water"

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

Model GP-01 Combustible Gas Monitor Operator s Manual

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

G-TECTA TM. Portable Gas Detection Instruments

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Instrumentation Understanding Environmental Surveillance

Using the QRAE Plus personal multigas monitor

Model GX Operator s Manual

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

GX-2009 Portable Gas Monitor Operator s Manual

Pressure measuring instruments

Tetra 3. User Manual. Personal Multigas Monitor. M07654 January 2007 Issue 3

Hygrometer / Air Quality Meter

SENSIT HXG-2d Combustible Gas Detector

Registered address: 7 Drakes Drive, Crendon Business Park Long Crendon, HP18 9FE

Bacharach Bodyguard 4 User's Guide

Reference Manual Ex Chek Alkaline Version Combustible Gas Detector

Datalogging as standard

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Polytector III G999 for Ex zone 0

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

GAS-Mate. Combustible Gas Leak Detector

Dräger X-am 2500 Multi-Gas Detector

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

LS1. Operator Manual. Kane International Ltd

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

testo 316-EX gas leak detector Instruction manual

intrinsically safe detector for hydrocarbon gases

RAE Systems Systems. User Presentation. October Protection Through Detection

Model GX Operator s Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

GENERAL STANDARD FOR GAS DETECTORS ORIGINAL EDITION MAY 1997

GX-2009 Portable Gas Monitor Operator s Manual

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Transcription:

Vasthi Explosive Meter Sheet No. 1 of 5 000000000000000000000 Vasthi Monitors for Combustible Gas.

Vasthi Explosive Meter Sheet No. 2 of 5 Description : Vasthi (Model VS-70 E) HAND HELD PORTABLE COMBUSTIBLE GAS DETECTOR is a compact battery operated portable instrument used for taking an air sample and indicating the presence and concentration of combustible gas. Samples of the air under test are drawn by means or a rubber aspirator bulb and analysed for combustible gas content on a heated platinum filament in a Wheatstone bridge measuring circuit. A built-in meter indicates combustible gas content in units of explosibility. Power for operation or the instrument is provided by Lithium ion battery. A probe and extension hose permit withdrawal of samples from remote locations and the instrument fits in a compact leather case with over the shoulder carrying strap. The model VS-70 E is suitable and recommended for testing tanks, manholes, vessels, pressure cylinders, pipelines, and other closed systems or confined spaces to determine presence or absence of combustible gas. It is a valuable aid for safety of operations whenever combustible gases or vapors are handled. Examples of confined spaces: Storage tanks and vessels Sewers and manholes Underground utility values Railcar tanks Marine vessel tanks Tunnels Grain elevators Petro refinery industries Operation:- Before using the instrument for job, check battery status. If it cannot be set beyond mark batteries need recharge with Vasthi Make Charger for recharging purpose. The display should show the battery indication while you kept for charging. And the display should show zero reading. If it not showing zero. Continue with the next steps of preliminary adjustment as follows: A. Select the Calibration mode. B. Select the Auto zero. C. Provide the password which is set by factory. D. Than select the set zero, press ok. E. Than display will show the zero reading at safe area. F. With sample inlet in fresh air, squeeze bulb several times to flush out any remaining gas.

Vasthi Explosive Meter Sheet No. 3 of 5 G. Check zero setting by turning switch to ON position. Meter should read close to zero. Lift and turn ZERO knob to bring reading to exactly 0. H. Couple sampling hose to instrument inlet on left hand end, and connect probe to end of hose.hold finger over probe to block flow and squeeze bulb. Bulb should remain squeezed while finger blocks inlet. I. Admit a sample of some combustible gas to end of probe, and confirm that meter rises upscale. Instrument is adjusted and ready to use. lt may be turned off and carried to the job. About Calibration & Working Principle: Vasthi Explosive Meter readings are taken on a scale graduated 0-100% LEL. The abbreviation L.E.L. stands for Lower Explosive Limit, and represents the lowest concentration, which can be ignited by a source of ignition, hence the lowest concentration which can produce an explosion. This quantity is also spoken of as the Lower Flammable Limit (L. F. L.). The model VS-70 E is calibrated before shipment to read directly in percent L.E.L. of methane in air, based on the known L.E.L. for methane of 5.0% by volume. That is, a 5.0% by volume will produce a reading of 100%, and smaller concentrations will read in proportion. Other combustible gases will read in approximate terms of explosibility. For maximum accuracy, the unit should be calibrated to the gas intended to be detected. Concentrations may also be interpreted in terms of volume percent by multiplying the percent L.E.L. in the sample (determined from the meter reading and the curve) by the published figure for L.E.L. in volume percent. as noted on the curve. The maximum concentration allowable in a space where men are working or where welding operations are carried out is primarily a matter of local regulation and of judgement based on knowledge of conditions. A maximum reading of 10% or 20% is usually allowed. If 20% is selected, this is often spoken of as a factor safety of 5, as the concentration must be increased five times before explosive conditions are reached.

Vasthi Explosive Meter Sheet No. 4 of 5 GA DRAWING

Vasthi Explosive Meter Sheet No. 5 of 5 Modus operandi: - This Model is battery operated. They transmit warnings via a series of audible and visible signals such as alarms and flashing lights, when dangerous levels of gas vapors are detected. As detectors measure a gas concentration, the sensor responds to a calibration gas, which serves as the reference point or scale. As a sensor s detection exceeds a preset alarm level, the alarm or signal will be activated. As units, gas detectors are produced as portable or stationary devices. Originally, detectors were produced to detect a single gas, but modern units may detect several toxic or combustible gases, or even a combination of both types. INSTRUMETN SPECIFICATIONS:- Sampling Method : Diffusion or Auto Suction Sensors Life : 5 years for Catalytic. Measurement : 0-100 % LEL Continuous. Readout : Graphical Digital Resolution : 0.1 Accuracy : +/- 1 % Repeatability : +/- 1 %. Response Time : < 10 seconds at 95 % variation. Alarms : Low & HI Visual and Audible (Different Tones). Low Battery Alarms: Audio & Visual. Power Supply : Standard batteries Battery backup : continuous 8 hours. Temperature Range: 0 55 Deg. C. Warranty : One year. Display : 128 X 64 Pixels Graphical LCD Power : Single cell lithium ion Battery with In built charge control Weight : 445 grams (approx.) Dimensions : Refer to GA Drawing Degree of Protection: IP 65 Vasthi Engineers Pvt Ltd D.No.4 17 91/18A, 3 rd Lane Velangini Nagar, Guntur 522 002 Andhra Pradesh, India Visit on us: www.vasthi.com Write us vasthi.engineers@hotmail.com, info@vasthi.com T: +91 863 2238 667, +91 95816 78685, +91 73827 08685