Research Article. Analysis of moisture content of pulses pellets using fluidized bed dryer

Similar documents
Performance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

Inclined Fluidized Bed Dryer Performance in Energy Saving Option

Drying Parawood with Superheated Steam

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Measurement of Drying Rates in a Domestic Scale Fluidized Bed Dryer

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

QAQC LABS ANALYTICAL DRYING

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Drying principles and general considerations

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

American International Journal of Research in Science, Technology, Engineering & Mathematics

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Mathematical Simulation of Longan Fruit Drying

Cassava Chip Drying by Using a Small-Scale Hot-Air Microwave Oven

[1] Lecture 2 Particulate emission control by mechanical separation & wet gas scrubbing

HUMIDITY RELATIONSHIP DETERMINATED IN THE DRYING CEREAL SEED FLUIDIZED BED

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Evaluation of moisture content in drying of grated coconut meat using grain moisture meter

INFLUENCE OF DRYING CONDITIONS ON THE MOISTURE DIFFUSION DURING SINGLE STAGE AND TWO STAGE FLUIDIZED BED DRYING OF BOVINE INTESTINE FOR PET FOOD

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

ROTATION-PULSED FLUID BED SALT DRYER. Todor Djurkov

An Experimental Study on Drying of Pistacia Terebinthus in a Fixed Bed Dryer

Research Contributions of Professor Arun S. Mujumdar, NUS, Singapore Arun S. Mujumdar

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Specific Energy Consumption of Heat Pump Drying System

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Solar Drying Techniques And Performance Analysis: A Review

Heater Surface Coating Effect on Fluidized Bed Heat Transfer Coefficient

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Performance investigation of Air-conditioning system using ejector as expansion device

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

A study of Transient Performance of A Cascade Heat Pump System

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Design and Construction of VFBD and Drying Kinetics of Muskmelon Seeds

Available online at I-SEEC Proceeding - Science and Engineering (2013) 19 26

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Komline-Sanderson Paddle Dryer. Drying technology for biosolids, sludges and by-products

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Study on the Effect of Blade Angle on the Performance of a Small Cooling Tower

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

INFLUENCE OF DIFFERENT TEMPERING PERIOD AND VACUUM CONDITIONS ON THE RICE GRAIN BREAKAGE IN A THIN LAYER DRYER

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

Optimizing Chemistry and Coater Settings for Faster Drying

Lecture # 5: SOLVED PROBLEM

Use of heat pump dehumidifiers on industrial drying of chili

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

CLOVER DRYING PROCESS BY FORCED CONVECTION

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

Refrigerant Mass and Oil Migration During Start-up Transient

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

A new test procedure to measure the soil-water characteristic curves using a small-scale centrifuge

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Performance Evaluation of Paddy Rice Pneumatic Dryer

Design, Development and Experimental Investigation of Volumetric Air Receiver

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

New Software for Simulation of Drying and Evaporation Systems

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Hot Air-Microwave Combined Drying Characteristics of Gypsum Board. Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1

Drying paddy by microwave vibro-fluidized bed drying using single mode applicator

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

ENSC 388: Engineering Thermodynamics and Heat Transfer

Effect of Magnetic Field on Convective Drying Of Ceramic Clay

Downstream Processing Prof. Mukesh Doble Department of Biotechnology Indian Institute of Technology, Madras. Lecture - 36 Drying

Effect of different air velocities on convective thin-layer drying of alfalfa for livestock feeding

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

Chapter 3 DESIGN OF THE STUDY

MODEL AND SIMULATION OF DEEP-BED CLOVE DRYING: EFFECT OF FERMENTED TREATMENT

Enhancement of COP using Nanoadditives in Domestic Refrigerator

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Purdue e-pubs. Purdue University

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

A Microcontroller-Based Monitoring System for Batch Tea Dryer

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

A Study of Heat Transfer Using Corrugated Al 2 o 3 microparticles

Thermal Performance Of Low Cost Solar Bamboo Dryer

Effect of Vacuum Cooling Operation Parameters on Cooling Time and Weight Loss of Chinese Cabbage

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Performance Enhancement of Mini Refrigerator with Phase Change Materials

Drying of Fruits, Vegetables, Spices and Medicinal Plants with a Mixed-Mode Solar Drying System with Internal Reflectors

Transcription:

Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 215, 7(6):447-451 Research Article ISSN : 975-7384 CODEN(USA) : JCPRC5 Analysis of moisture content of pulses pellets using fluidized bed dryer Vibha Verma Deshmukh, Neeraj Chandraker, R. S. Thakur and A. K. Chandrakar* Department of Chemical Engineering, IT Guru Ghasidas Vishwavidyalaya (GGV), Bilaspur, Chhatisgarh, India ABSTRACT Fluidized is formed when solid particulate substance (usually present in a holding vessel) is placed under appropriate conditions to cause the solid/fluid mixture to behave as a fluid. This is usually possible by the introduction of pressurized fluid through the particulate medium. Fluidized bed dryer are primarily used in almost all chemical, pharmaceutical, food, dyestuff and other process industries to dry materials by fluidization with hot and/ or dehumidification air, which create a turbulence in the wet product (not totally liquid) while flowing through it. It is gives best result for powders, granules, agglomerates, and pellets with an average particle size between 5 and 5, microns. Very fine, light powders or highly elongated particles may require vibration for successful fluid bed drying. It is operated when moist material is feed onto a shaking perforated steel/glass bed through which the drying air flows. Fluidizes, the bed of material allowing intimate contact with each and every particle. On the introduction of air, shaking will occurs to the total length of the dryer bed. Moisture is removed by the flow of hot air throughout the bed having different type of grams. Air flow is controlled along the length of the dryer to maximize fluidization. After the grams moisture removed it will send to the cooling zone where hot air will be replaced by the cool ambient air, which will reduce the (desired) product temperature. The drying rate increases as increasing the velocity of the drying air, while decreases with increases solids holdup. This article deals with the study of initial and final moisture content, temperature and weight of grams or moisture content at different intervals, pressures and comparison between all the three pulses moisture content using fluidized bed dryer of split pea gram, Split, and Split pellets. Key words: Fluidized bed dryer (FBD), split pea gram, Split, and Split INTRODUCTION Fluid bed dryers are used extensively for drying of wet particulate and granular materials such as agricultural products, foods, chemicals, ceramics, minerals, and pharmaceuticals. Fluid bed systems give important advantages such as good material mixing, high rates of heat and mass transfer, low capital and maintenance costs, and ease of control and material transportation [1]. Based on moisture content of the products, drying kinetics from the text books refers constant rate period followed by falling rate period with the demarcation based on the critical moisture content. Drying of cereal grains, including rough rice, mostly occurs in the falling rate period and the moisture transfer during drying is controlled by internal moisture diffusion [2]. On the other hand, these materials have a very short duration constant rate period and a longer curvy linear falling rate period [3, 4]. The principle behind the drying process is to blow a hot gas upward through a bed of particulate material to be dried. The gas is distributed evenly through small orifices supporting the material at a rate sufficiently high to cause incipient fluidization of particles but not so high as to give the appearance of a vigorously bubbling bed. The fluidized bed drier can be operated continuous or batch wise. The fluidized bed drier can be operated continuous or batch wise. The drying kinetics is important for the estimation of the performance of the drier. A complex transport phenomenon takes place during drying process including unsteady state heat and mass transfer which occurs simultaneously [5]. Heat necessary for evaporation is supplied to the particles and moisture vapor is removed from the material into the drying medium. Heat is transported by 447

A. K. Chandrakar et al J. Chem. Pharm. Res., 215, 7(6):447-451 convection from the surrounding to the particle surfaces and then by conduction from there into the inside of particles. Moisture is transported in the opposite direction as a liquid or vapor on the surface evaporates and passes on to the surroundings by convection [6]. The heat and moisture transfer rates are related to drying air temperature and Reynolds number as a function of velocity of circulating air. Thus mass and energy balance mechanisms are involved in drying operations. The developments of the regime of fluidization and subsequent design modifications have made fluidized bed drying a desirable choice among other driers. However the efficiency of the conventional drying system is usually low. It is therefore desirable to improve the efficiency of the drying process. Drying process has usually three typical drying rate periods [7] namely pre-warming period, constant rate and falling rate period. The different theories have been used to describe moisture evaporation in the different periods. The diffusion controls the drying process especially in the falling rate period [8]. Sender et. al. [9] reviews common air distributors used in fluidized bed drying of food particulates and also reviews special methods of fluidizing larger irregular food particulates. Depending on the size and shape of the materials, methods employed to achieve effective fluidization during fluid bed drying varies from use of simple hole distributors for small, light weight materials to special techniques for larger and/or moist materials [9]. This article deals with the drying of pulses, which are most important gram and having lost of protein and fiber. Now a day s consumption of pulses is increases as population increases. Lots of pulses destroyed due to moisture content. So, drying operation is the best way to protect the pulses from moisture. EXPERIMENTAL SECTION Material: Fluidized bed dryer consist of a glass column, the conical portion, which is filled with fluidizing material. The material is supported on the screen mesh held between two flanges. Air from the compressor is heated in the heater box and passed through the column. Air rotameter is provided to measure the air flow rate. The flow rate can be adjusted by SS needle valve provided for air supply to the column. Sensors are given at different position to measure the temperature at different points. Pulses of three different varieties (split pea gram, split bengal gram, and split red gram pulses) had been taken to know its drying rate, moisture content with respect to time and temperature. Initially take pulses of each sample and dipped it into water for 3 hrs. After 3 hrs keep that pulses into fluidized bed dryer for drying. Method: Take about 2gms of split pea gram, split bengal gram, and split red gram pulses. Add known amount of water in it i.e. 25ml for 3 hrs after 3 hrs that pulses will become wet and its weight as well as moisture content will increases then load the conical portion of the dryer with that wet material from the top of the column. Close the lid. Start the blower and adjust the air flow rate at the desired level i.e. 7-9 LPM. Start the heater and adjust the varies to obtain the desired air temperature (i.e. 8 to 1 o C ). Allow the air to pass through the bypass line till desired air temperature is reached. Allow the hot air at prefixed flow rate and temperature to pass through the dryer. The flow rate should be sufficient to fluidize the material. At regular intervals of time interval of time take out 5 gram of wet material and weigh it. Dry it completely and weigh it again and hence record the moisture present. Repeat the procedure 1-7 times to know its moisture content at different time intervals. There are two procedures they are: A. Theoretical Analysis There are two ways of specifying the moisture content [1]. Moisture content in any sample is calculated as the percentage difference between the wet weight of the sample and the dry weight of the sample. If the percentage difference is calculated relative to the wet weight of the sample, it is called the wet basis moisture content and if it is calculated relative to the dry weight of the sample, it is called the dry basis moisture content. Thus wet-weight basis (M w ) and dry-weight basis (M d ) are calculated as the following. M d = w d/ d M w = w d/ w (1) (2) where, w = total weight of product, kg & d = weight of dry product, kg Moisture content on dry basis has been used for all calculation purpose in this paper. 448

A. K. Chandrakar et al J. Chem. Pharm. Res., 215, 7(6):447-451 B. Equilibrium moisture Drying generally occurs in three different periods, or phases, which can be clearly defined. In first phase, the sensible heat is transferred to the product & the contained moisture, which will increases the evaporation rate & removed the free moisture. Whereas on second phase or constant rate period, drying rate are high and higher inlet air temperatures than in subsequent drying stages can be used without detrimental effect to the product and relatively small increase in the product temperature during the second period. A common interesting occurrence is that the time scale of the constant rate period may determine and affect the rate of drying in the next phase. The third phase, or falling rate period, is the phase during which moisture migrate from the inner interstices of each particle to the outer surface becomes the limiting factor that reduces the drying rate. Drying usually occurred in the falling rate period for all materials during this investigation. The variation of average moisture content of the sample as non-dimensional moisture ratio with time of drying [11] operation is expressed as: MR= M-Me/ (Mo- Me) (3) RESULTS AND DISCISSION Mass in dry basis (Md): As the time increases rate of dryness also increases because the moisture is evaporated when heat will provided and best result were found among three gram i.e. in split red gram, shown in figure 1.data or values are calculated by using equation 1. Mass in wet basis (Mw): Similarly in case of wet basis, best result is found in case of split red gram. Data s are calibrated by equation 2 and shown in figure 2. Effect on moisture ratio: As the temperature increases the rate of drying is also increases where as moisture content ratio is continuously decreases as the time increases. The best rate of drying among them in the case of pea gram was found, shown in figure 3.Moistur ratio are calculated by using equation 3. Effect of moisture content to the initial moisture content: Ratio between moisture content to the initial moisture content increases as the time increases and more drying will occur in case of split pea gram on comparing with others, shown in figure 4. M d (M ass in dry-w eigh t basis, kg) 1.9.8.7.6.5.4.3 pea gram 5 1 15 2 25 3 35 4 time (min.) Figure 1. Graph between mass in dry weight basis, kg verses time in minutes between split, split red gram and split pea gram 449

A. K. Chandrakar et al J. Chem. Pharm. Res., 215, 7(6):447-451 Mw (Mass in wet-weight basis, kg).6.5.4.3 5 1 15 2 25 3 35 4 Figure 2. Graph between mass in wet weight basis, kg verses time in minutes between split, split red gram and split pea gram.6.5.4 MR.3 5 1 15 2 25 3 35 4 Figure 3. Graph between moisture ratio verses time in minutes between split, split red gram and split pea gram.6.5.4 C /Ci.3 5 1 15 2 25 3 35 4 Figure 4. Graph between moisture content to the initial moisture content verses time in minutes between split, split red gram and split pea gram 45

A. K. Chandrakar et al J. Chem. Pharm. Res., 215, 7(6):447-451 CONCLUSION The drying characteristics of materials (pulses granules) have been assessed in the fluidized bed dryer with respect to the various operating variables and distributor plates. The drying rate is found to increase significantly with increase in temperature and flow rate of the heating medium as the time increases. Best result were found in case for moisture ratio and initial to the final moisture content is split pea gram and split red gram is found in case of mass in dry basis and wet basis. The results can be improved by using more time intervals. The results or drying rate can be decreases when the equipment becomes over loaded. Acknowledgment We acknowledge the valuable guidance and support to my guide during the course of our work. His constant encouragement, insight and close attention to details have ensured the successful completion of this work. We sincerely express our thanks to the Head of the Department and all faculty members of the department for the encouragement and help. We are also obliged to all the staff members of the Chemical Engineering department for giving the much needed help whenever required. We would like to thank all the people associated with the project and those who helped us directly or indirectly to complete the project. NOMENCLATURE Mw: Mass in wet-weight basis, kg Md: Mass in dry-weight basis, kg w: Total weight, kg d: Dry weight, kg M: Moisture Content, % wet basis Mo: Initial Moisture Content, % wet basis Me: Equilibrium Moisture Content, % wet basis MR: Moisture ratio, non-dimensional T: drying time, min C: moisture content (dry basis), at time t, minute. Ci: initial moisture content (dry basis) REFERENCES [1] A. S. Mujumdar, Handbook of Industrial Drying, 3 rd Edition, Taylor and Francis Group, London, 26; 164-165. [2] N. Wang and J.G Brennan, Effect of water binding on the drying behavior of potato. In: Drying,Eds, A.S. Mujumdar. Elsevier Science Publishers, London, 1992; 135-1359. [3] C. Strumillo and T. Kudra, Drying: Principles, Applications and Design. Gorden and Breach, New York, 1986; 67-98. [4] C. Srinivasakannan, S. Subbarao, and Y.B.G. Varma Industrial and Engineering Chemistry Research, 1994, 33, 363-37. [5] S. Husain, H. Akihiko and H. Naoto, Memories of the Faculty of Engineering, Okayama University, 27, 41, 52-62. [6] D. Mowla, and H. Montazeri, J. Aerosol Sci., 2, 31 (Suppl. 1), 793-794. [7] C. Vanecek, M. Markvart and R. Drbohlar, Fluidized bed drying, Lenard Hill, London, 1996. [8] H.G. Wang, T. Dyakowski, P. R. S Senior and W. Q. Yang, Chemical Engineering Science, 27, 62, 1524-1535. [9] W. Senadeera, B., R. Bhandari, G. Young and B. Wijesinghe, Drying Technology, 2 18(7), 1537-1557. [1] A. Boonloi and P. Promvonge, The 2nd joint international conference on sustainable Energy and Environment, Bangkok, Thailand, 26, E-59(P) 1-4. [11] W. Senadeera, 16thInternational Drying Symposium (IDS 28), Hyderabad, India, 28, 326-329. 451