Low air consumption vacuum generators

Similar documents
Self-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.

Self-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.

Self-regulating vacuum pumps. Characteristics. bar (Nl/s) Specifications

Characteristics. Ø nozzle. model

Air. Pressure. Motion. nnnnnnnn

FIPA Vacuum Components

Vacuum generation Content

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

multi-stage vacuum generators - general information

MVG. Modular Vacuum Grippers. US5

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

Vacuum generators VADM/VADMI

VS LD series vertical steam sterilizers

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Vacuum generators VADM/VADMI

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

C 9000 Polymer Quick-Acting Safety Coupler Range

MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI

AIR-OPERATED OIL PUMPS 73. Air-operated pumps for distribution

Compact. Cost effective. Productive. GSW-V Vacuum Gripper

Collaborative Robot Vacuum Tool Unparalleled flexibility in collaborative robotics. We make things MOVE

NEW! Dosing Cell 3E. 2-component low-pressure mixing and dosing system

1,000W (DAP-60K: 100 W per digestion vessel)

½ Monitored Pneumatic Valve Patented Technology

REVO JOB INSTALLATION AREA. REVO Job SELECTION TABLE MAIN FEATURES OF THE PRODUCT PROFESSIONAL. CE marking. Automatic filter cleaning

Vacuum suction nozzle OVEM-...-1P/1N

Introduction pisave optimize pisave onoff pisave release pisave sense pisave restrict...488

½ Monitored Pneumatic Valves On Series Ported Manifold

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

TopMaster Air Handling unit. Technical data

ERGONOMIC TECHNOLOGY. 1

Getinge 8666/8668 Washer Disinfectors

STERILIZER STEAM - GLOBO 6412 INNOVATING TRADITION

Product Specification RobExtractSpray 2400/4400

KIT-UR-V. IST-KIT-UR-V Page 1 of 12 REVISIONS DOCUMENT LAYOUT MOUNTING INSTRUCTIONS AND OPERATING MANUAL

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

FINISHING EQUIPMENT NOVA-S-PLUS. Vacuum/blowing ironing table

INSTRUCTIONS & PARTS LIST FOR NO. 658, 660, 690, 697 SIOUX AIR RANDOM ORBITAL SANDER INCLUDES B, V, VV, & X SUFFIXES (SERIAL E )

Monitored Pneumatic Valves On Series Ported Manifold

07 WASTE OIL EQUIPMENT

Crimping tools for D-Sub contacts Crimping tools for other contacts Crimping machine TC-C

TOX -Spray System SP. Data sheet /

Vacuum generators. Festo core product range Covers 80% of your automation tasks

1 VICTRIX ZEUS Superior kw I features

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

CPF PRODUCT DESCRIPTION

Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)

Vacuum generators VAD/VAK

Vacuum- Generation and Monitoring. Product brochure 2015/16. > Vacuum Generation. > Vacuum Monitoring. Ejectors for efficient vacuum generation

Practic - HLE. Piston Compressors 2 TO 10 HP 6 TO 500 LITRES


When reliability is vital. Alemite Carbon Shield TM Systems deliver

VACUUM PUMP Micro Cartridge Pump

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

Capture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING

L30 - L250. Oil Injected Rotary Screw Compressors. Engineered to Save

The Safest Connections...

Central Vacuum Systems SINCE 1993 PRODUCT RANGE. Expertise & innovation

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve

u JOSSI FIRE SHIELD U JOSSI METAL SHIELD U JOSSI COMBO SHIELD Technical Data

PRINCIPLE FOR DEHUMIDIFYING CRAWL SPACES

Fluid Bed Processor LFP LÖDIGE ALWAYS THE RIGHT MIX

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

Mink MV. Claw Vacuum Pumps for Rough Vacuum Industrial Applications. Claw Vacuum Technology by Busch

Solar Controller Training Presentation

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Operating instructions

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

M700-Series Multifunction OTDR

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Tools for other contacts Tools for FOC contacts Crimping machine TK-M Crimping machine TC-C

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

Operation Manual. Mobile Dustfree Pressure Air Blasting System HSP-20

Screw Compressors ESD SERIES. Capacities from: 816 to 1522 cfm Pressures from: 80 to 217 psig

Technology that works fast. Inverter Ducted Systems

ADSORPTION DRYERS. For all applications which require perfectly dry compressed air : Advantages of "ALC" dryers :

BULLETIN: APPL-QAF-133R1

NHR-25 Feed Hopper with Agitator

PBT-1 Internal Pipe Blasting Tool

Suction Vacuum Cups and Pads A huge selection, high quality and efficiency have made us the fastest growing source in North America for suction cups,

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN ZVSHK 1) DVGW 2) for Professionals

Digital LEAD FREE. Soldering Soldering. Temperature range. Station. N1-06 Nozzle ø0.6 N1-08 Nozzle ø0.8 N1-10 Nozzle ø1.0 N1-13 Nozzle ø1.3. ø2.

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

OIL COOLER INSTRUCTION HANDBOOK

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Fume extraction system FEC.

CONVEYING. Single units - Conveying METRO

COMPANY PROFILE

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Room Unit. Building Technologies SYNERGYR

Air to water Heat Pump System

SPACEMOTION SERIES SMM 01

Transcription:

Low air consumption vacuum generators

Regulated venturis, series GVMAX Electric Gripping display LED 168 50.2 35 61 ø.2 Exhaust 1/2 Gas 1/ Gas or Quick-connect 68 8 5.5 bar compressed air network 35 56.7 ø30 92.2 Release display LED 70.2 Vacuum 1/2 Gas 5 ø.2 Vacuum switch PSA 100 C Blowing flow restrictor White: CONTACT output Brown: +2 V DC (gripping) Applications: Dialogue between two components, the electronic vacuum switch and the gripping valve controller, allows the consumption of compressed air to be regulated and, above all, considerably reduced. This range of venturis is strongly recommended for the gripping and holding of non-porous materials, and for medium or long cycles. An electrically controlled blowing device is built in for the release function. Characteristics Max. vacuum Drawn-in air L2 Weight as % Nl/min mm g Models X T N X T N S K* GVMAX E1 50 75 90 360 20 200 60 121 510 (*) Supplied with version X on standard basis See page 5 for air consumption. Black: + 2 V DC (blowing) Blue: Common 30.2 1/ Gas Tube 6x8 Specifications: Compressed air Filtered, non-lubricated 2 to 6 bars, optimal 5 bars Temperature 0 to 60 C Contact output PNP on-off, NO or NC, adjustable hysteresis Anti-interference Integrated with display LED Gripping flow rate Adjustment by flow rate reducer Operating principle: When the selected vacuum level is reached, the compressed air supply is shut off. This shutoff has no effect as the non-return function of the check valve maintains the negative pressure generated and thus gripping of the object. The vacuum switch ensures continuous analysis of vacuum requirements. As soon as the minimum threshold is reached, it opens the venturi and the preselected vacuum level is restored. Safety: The GVMAX E1 is equipped, on a standard basis, with a non-return valve enabling it to maintain the vacuum in the system in the event of electric power failure. This feature provides the operator with maximum safety during handling operations. GVMAX 1 2 3 E1 1: Characteristics X 50% vacuum T 75% vacuum N 90% vacuum 2: Silencer - Without silencer S Large reduction in db K Through 3: C.A. coupling 1 1/ G BSPP 68 Tube 6x8 Curves and characteristics on page 5. 2

Applications with air economy venturis Clamping: During the finishing stage, a snowboard must be held in position for several minutes. Using venturis with the air economy device results in considerable energy savings. Emptying a container: 1/ turn valve for venting For this type of application, we use venturi regulation capabilities. The hysteresis of the on-off regulating control can be adjusted to between 1 and 25% vacuum on electric models. Caution: For the regulation of vacuum levels in a tank with a capacity of more than 10 litres: consult us for pneumatic versions. Safe holding: Sealed parts The safety functions on both the electric and compressed air power supplies ensure that, in the event of failure of one of the two power sources (or both of them), the sealed parts being handled are held while the operator makes the machine completely safe. Holding in case of failure of electric power supply or compressed air supply.

Curves for low air consumption venturis under negative pressure with a venturi GVE NS 1 E1 at 5.5 bars. 10 0.2 0.9 20 0.3 1.8 30 0.6 2.9 0 0.8.2 50 1.1 5.9 60 1.5 7.8 70 2.1 10.9 80 3.0 15.7 85.0 21.0 under negative pressure with a venturi GVEMAX TS 68 E1 at 5.5 bars. 10 0.2 0.9 20 0. 1.8 30 0.6 3.1 0 0.9.5 50 1.3 6.6 60 1.8 9.6 70 3.2 16.7 under negative pressure with a venturi GVEMAX XK 1 P1 at 5.5 bars. 10 0.1 0.5 20 0.3 1.1 30 0. 2.1 0 0.7 3.5 5 1.0 5.1 Vacuum in vessel Curves: Vacuum level with respect to time for a regulating cycle Vacuum in vessel Venturi consumption Delta t depends on the leak rate and the regulated volume Time 5

Regulated venturi, series GVMAX SP 35 The intelligent venturi GVMAX SP 35 The regulated venturi GVMAX SP 35 has a number of integrated functions which meet the demand of automatic devices in industry : security, energy-saving and high performance. The compactness of this venturi simplifies its integration to all production lines. Its easy installation and maintenance allows the reduction of operation costs. This venturi is highly requested by the main European car manufacturers and in other fields as aeronautics, robotics etc. On request, special literature available in French, English, Spanish, Italian and German. 6