THE QUALITY BRAND IN FANS

Similar documents
THE QUALITY BRAND IN FANS

F6102 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER

WYND DC 54 CEILING FAN Installation Manual

Ceiling Sweep Fan Assembly Instructions

LUCCI AIRFUSION QUEST II CEILING FAN

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

FANAWAY CLASSIC CEILING FAN

CEILING FAN OWNER'S MANUAL

OWNERS INSTRUCTION MANUAL

CEILING FAN OWNER'S MANUAL

LUCCI AIRFUSION ARIA CEILING FAN

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

LUCCI AIRFUSION AIRMOVER CEILING FAN

LUCCI AIRFUSION AIRLIE II ECO SERIES CEILING FAN

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

FANAWAY LED EVO1 RETRACTING BLADE CEILING FAN

CEILING FAN OWNER'S MANUAL

LUCCI AIRFUSION SHOALHAVEN CEILING FAN

LUCCI ALTITUDE ECO LED CEILING FAN

LUCCI AIRFUSION TAKEKO CEILING FAN

AERO SERIES CEILING FAN

CEILING FAN OWNER S MANUAL

Torrena 42 Ceiling Fan

Camarillo 52 Ceiling Fan

THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS

CEILING FAN OWNER S MANUAL

FUTURA ECO SERIES CEILING FAN

52 STRATHMERE CEILING FAN

LUCCI NORDIC DC CEILING FAN

LUCCI WHITEHAVEN DC CEILING FAN

LUCCI AIRFUSION RESORT DC CEILING FAN

READ AND SAVE THESE INSTRUCTIONS OWNERS INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

CEILING FAN OWNER S MANUAL

DC CEILING FAN MODELS ICF72, ICF96

FUTURA SERIES CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

BAYSIDE CALYPSO CEILING FAN

AIRFUSION MOONAH SERIES CEILING FAN

52 BAYTOWNE CEILING FAN

BAYSIDE JETSTREAM CEILING FAN

LUCCI AIRFUSION MARINER CEILING FAN

FOR AMD SAVE THESE INSTRUCTIONS OWNER'S INSTRUCTION MANUAL CAUTION. Intertek. Note: Approximate time of assembly is 30 min to 1 hour.

Installation and Operation Manual For Hunter Ceiling Fans /16/2004

LUCCI AIRFUSION FRASER DC CEILING FAN

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

LUCCI FUTURA MOOD LED CEILING FAN

BAYSIDE NAUTILUS CEILING FAN

IMPERIAL. SERIES Ceiling Fan Instruction Book. Models: MIF123 MIF1233 MIF1234 MIF124 MIF1243 MIF1244

52 BARSTOW CEILING FAN

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

Ceiling Fan Ow n e r s Manual

INSTALLATION MANUAL CFFCHZ4WHW - CFFCHZ4WHR - CFFCHZ4BRW - CFFCHZ4BRR CFFCHZ3WHW - CFFCHZ3WHR - CFFCHZ3BRW - CFFCHZ3BRR

Ceiling Fan Installation Instructions

installation and operation manual for Hunter Ceiling Fans

WAILEA OWNER S MANUAL

CEILING FAN MANUAL INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION LUCCI AIRFUSION COMMAND II CEILING FAN CAUTION

52 SAN LUCAS CEILING FAN

DC CEILING FAN MODELS ICF72, ICF96

48 TAYLOR CEILING FAN

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

installation and operation manual for Hunter Ceiling Fans

Turin LED Ceiling Fan

Model: AC-108. Instruction Manual

Electrician Installation Manual EM-E Ceiling Fan

Owner s Guide and Installation Manual

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

30-YEAR LIMITED WARRANTY

MALIBU STAR OWNER S MANUAL

Electrician Installation Manual Icon 52 inch (132cm) Ceiling Fan

CEILING FAN OWNER'S MANUAL

LIMITED LIFETIME WARRANTY

National Warranty Line

Owner s Guide and Installation Manual

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

READ AND SAVE THESE INSTRUCTIONS

Installation and Operation Manual For Hunter Ceiling Fans

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

CEILING FAN OWNER S MANUAL

Model No: 56DFH-L HS-1289-C. Cover for non-light option

52 BERKSHIRE CEILING FAN

SPRINGHILL 44 CEILING FAN

CEILING FAN OWNER'S MANUAL

Owner s Guide and Installation Manual

LUCCI GRENADA SERIES CEILING FANS

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

5SLR52XXD-B Series Fan UL Model No. : 5SLR52. Owner s Guide and Installation Manual

The Monaco Patio. Please read and save these instructions

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

#ADENCE4- $ESIGNED )NCLUDES #OOL4OUCH4- +ICHLER )NSTRUCTION #USTOMER KHA

THE GUSTO CEILING FAN INSTALLATION INSTRUCTIONS

TOUCHDOWN 48 CEILING FAN

CEILING FAN OWNER'S MANUAL

Ceiling Fan Installation Instructions

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

ARTEMIS. U.S. Patents: D535,011; D535,015; D535,387; D535,388; D536,083; 7,481,626 INSTRUCTION MANUAL WARRANTY CERTIFICATE

Item:89522 P.1.

Transcription:

THE QUALITY BRAND IN FANS Minor design changes or otherwise may result in slight variations between the product illustrated and that which is contained within this package INSTALLATION AND OPERATION INSTRUCTION BOOK, REV 4.0 GRANGE SERIES Models: FC032128BS, FC032128WH, FC032134BK, FC032134BS, FC032134WH CEILING FANS

TABLE OF CONTENTS INTRODUCTION... 1 SAFETY PRECAUTIONS... 2 UNPACKING YOUR CEILING FAN... 4 FAN INSTALLATION INSTRUCTIONS... 5 WIRING DIAGRAMS... 8 INFORMATION FOR LICENSED ELECTRICIAN AND FAN OWNERS... 10 FAN OPERATION... 11 IMPORTANT FACTS... 12 A Rev 4.0

INTRODUCTION CONGRATULATIONS ON YOUR CHOICE Thank you and we are delighted you have chosen a MERCATOR ceiling fan for your home. Please read all instructions carefully before assembly and use. SAFETY NOTICES WARNING / CAUTION A WARNING / CAUTION notice denotes a hazard. It calls attention to an installation procedure, operating procedure, maintenance procedure, or the like, that if not correctly performed or adhered to, could result in damage to this appliance, personal injury or death. Do not proceed beyond a WARNING / CAUTION notice until the indicated conditions are fully understood and met. SAFETY SYMBOLS Alternating current Protective earth Warning/Caution 1 Rev 4.0

SAFETY PRECAUTIONS Please observe the following general safety precautions carefully before and during all phases of handling, installation, removal, operation and maintenance of this product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Mercator Lighting assumes no liability for customer s failure to comply with these requirements. SAFETY WARNINGS 1. Read all instructions and safety information. Review assembly diagrams provided before installing your new ceiling fan. 2. This fan must be installed by a licensed and qualified electrician according to SAA and local authority regulations. 3. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 4. Young children should be supervised to ensure that they do not play with the appliance. 5. All electrical works must only be undertaken after disconnection of the power by removing fuses or turning off the circuit breaker, to ensure all pole isolation of the electrical supply. 6. Do not use outdoors where it could be exposed to water or moisture. 7. This manual is not intended to instruct or assist untrained or unqualified persons to install this ceiling fan. 8. It is the responsibility of qualified, licensed installer and user to apply common sense and care at all times during installation and operation. HOW TO CHOOSE A PROPER LOCATION FOR CEILING FAN 1. According to regulations and to provide a safe clearance from the floor, the lowest point on the fan blade must be at least 2.1 metres (7 feet) from the floor. 2. For fan installed enclosed outdoors, the fan must be installed at least 1.5m from the perimeter of roof/eaves of the enclosure to protect the product from direct or indirect rain water or sunlight. 3. The chosen location for the fan must not allow the rotating blades to come into contact with any object. 4. Please check carefully and make sure that ceiling joists are strong enough and of adequate size to support the weight of about 35 kg. 5. To reduce the risk of fire, electrical shock or personal injury, please make sure that the fan mounting bracket is directly supported from the building structure. Do not mount to an outlet box. 6. The mounting bracket must be firmly screwed to a load bearing building structure e.g. a concrete ceiling, steel structure, or a timber frame. If additional timber frames are to be added, those must be securely nailed or screwed between the beams. 7. Attach fan blades after the fan motor housing is installed and properly secured. Keep the fan motor and blades in the original package until it is ready to be installed. 2 Rev 4.0

SAFETY PRECAUTIONS 8. Check and confirm, after the fan is completely installed, that all connections are proper and secure to prevent the fan from falling or causing property damages or personal injury. 9. Take care not to bend or damage the motor Drive Shaft or Fan Blades when handling or installing them. If such defect is noticed, please contact the Customer Service before installation of the ceiling fan. 10. Both the fan with light kit (accessory) and the hanging bracket must be earthed. 11. Use of an unapproved wall controller voids the warranty. Only Mercator wall controllers are approved for use with Mercator ceiling fans. Do not use solid state wall controllers. 12. This fan is compatible with some HOME IT systems. Please contact Mercator for further details. 13. Do not remove the fan from the ceiling after installation. 14. Make sure electricity is turned off at the main power box before commencing work. Turn off the power by removing fuse or turning off circuit breaker before installing the fan and replacing lamps. 3 Rev 4.0

UNPACKING YOUR CEILING FAN Open the original carton and verify the following items are available for the standard purchase of this product. It there are any missing or mechanically damaged items, contact the Mercator Customer Care. Do not throw away the carton or other packaging material as it may be needed if warranty replacement or repair is ever necessary. 1 x Hanger Bracket 1 x Motor Assembly 4 x Blades BALANCING KIT & SCREWS PACKAGE 1 x Glass Diffuser 1 x Wall Controller 1 x INSTRUCTION BOOK WARRANTY CARD 1 x 1x Use of an unapproved wall controller voids the warranty. Therefore do not control the operation of this fan from any wall controller that is not approved by Mercator for use with this fan. Do not use solid state controllers. 4 Rev 4.0

FAN INSTALLATION INSTRUCTIONS Make sure electricity is turned off at the main power box before commencing work. Turn off the power by removing fuse or turning off circuit breaker before installing the fan and replacing the lamps. The lowest point on the fan blade must be at least 2.1 metres (7 feet) from the floor. Make sure that ceiling joists are strong enough and of adequate size to support the weight of the fan of about 35 kg. 1. Fan, hanger bracket and light kit must be earthed during installation. Secure the mounting bracket to the ceiling joist or suitable piece of timber inserted between the ceiling joists. The bracket should be attached with two wood screws and washers supplied. 2. Remove covering plate on top housing by loosening two screws. Insert one blade through one of the slots on the side of motor housing. Align blade holes with holes on blade bracket. Secure the blade using screws and fibre washers supplied. Repeat the same step until all blades are installed. 3. Secure covering plate by tightening the two screws 5 Rev 4.0

FAN INSTALLATION INSTRUCTIONS 4. Carefully lift motor assembly onto hanger bracket. Install ball joint onto the hanger bracket opening. Rotate fan until notch on downrod ball engages the ridge on the hanger bracket. This will allow hands free wiring. Connect the wires in accordance to the wiring diagram provided. 5. Lift the canopy up to the hanger bracket, making sure not to break any wire connection. Secure the canopy using canopy screws supplied. Cover up canopy screws using screw cover. 6. This fan is approved for and can safely be used with 2 x MAX 20W CFL globes. For optimum lighting effect we recommend 2 x 12W CFL globes. Insert two B22 CFL globes (not supplied) into lamp holders. Dry your hands before installing globes. Keeping the globe clean is important as useful lifetime of a dirty globe could be shorter than a clean globe. Locate indentations on the neck of lamp diffuser and align them with protrusions on light kit. Lift the diffuser allowing the protrusions to engage the indentations on the diffuser. Twist the diffuser clockwise to lock it into place. Note: Twist the diffuser anticlockwise to remove it for lamp replacement. 6 Rev 4.0

FAN INSTALLATION INSTRUCTIONS LAMP REPLACEMENT Make sure electricity is turned off at the main power box before commencing work. Turn off the power by removing fuse or turning off circuit breaker before replacing the lamps. HOW TO INSTALL WALL CONTROLLER Do not mount wall controller near heat producing equipment. Wall controller provided is designed to be connected with the ceiling fan supplied in this package only. Other uses may cause personal injury or fire hazard. Use of wall/remote controller other than those approved by MERCATOR will void warranty. Make sure electricity is turned off at the main power box before commencing work. Turn off the power by removing fuse or turning off circuit breaker before installing the wall/remote controller. 1. Disconnect the power and remove the existing wall plate and switch (if any). 2. Set the speed control knob on the wall controller in the off position. 3. Tighten screws on the terminal blocks; make sure wire connections are wired correctly and secure. 4. Secure the wall controller to the wall with two screws provided. 7 Rev 4.0

WIRING DIAGRAMS WIRING DIAGRAM FOR FAN CONTROLLED WITH WALL CONTROLLER 8 Rev 4.0

WIRING DIAGRAMS WIRING DIAGRAM FOR FAN CONTROLLED WITH REMOTE CONTROLLER (OPTIONAL) 9 Rev 4.0

INFORMATION FOR LICENSED ELECTRICIAN AND FAN OWNERS Please read fault finder before calling for warranty. 1. FAN WILL NOT START I. Check that mains circuit breakers are in the ON position. II. Check that isolation wall switch is in the ON position. III. Check that speed control knob/pull chain is NOT in the OFF position. IV. Check that reverse control switch (if any) is FULLY turned to up (left) or down (right) position. V. Check that batteries in the remote handset (if any) are in good condition. VI. Check that transmission code setting (if any) on remote control handset and receiver is identical. VII. Check that live, neutral, ground and light (if any) wires from isolation wall switch, remote receiver (if any) through to fan are all wired correctly is accordance with wiring diagram. VIII. Check that all wire connections at wall switch, wire connector and/or terminal block are secured (not loosened). 2. FAN SOUNDS NOISY. I. Check suggested bulbs and fully tighten light fitting (version with light). II. Re-tighten all screws on fan blades (do not over tighten). III. Re-tighten all screws in the hanging bracket and covering plate. 3. MECHANICAL NOISE I. Let the fan run for about 8 hours for settling in period. 4. FAN TURNS BUT DOES NOT MOVE MUCH AIR I. The fan may be running in reverse (for fans with reverse running option). II. The distance from the ceiling to the fan blades is too small. III. The room may contain items which obstruct the air flow. IV. The fan may be too small for the size of the room. 5. FAN WOBBLES Check for wobble after each step. I. Check that all blade brackets are tightened securely. II. Most wobble problems result from inconsistent blade level. To check blade level, measure the distance from each blade tip to the ceiling. If measurements are inconsistent, adjustments of brackets will be required. III. Wobble problem could also result from deviations in distance from blade to blade. To check blade separation, measure the distance from blade tip to blade tip. Should measurements vary, loosen screws connecting blades and brackets (one at a time) then shift the blade to proper position and re-tighten screws. 10 Rev 4.0

FAN OPERATION A ceiling fan is an environmentally smart choice when it comes to cooling as well as helping to warm your room. You should see a reduction in both cooling and heating costs by regular use of your fans. SWITCHING SUMMER/WINTER SETTING Make sure fan is off and blades have stopped spinning before changing the summer/winter switch. Summer setting (marked S) Fan turns in counter clockwise direction. A downward airflow creates a cooling effect. This also allows you to set your air conditioner on a higher temperature setting without affecting your comfort. Winter setting (marked W) Fan turns in clockwise direction. An upward airflow creates moves warm air off the ceiling area. This also allows you to set your heating unit on a lower setting without affecting your comfort. 11 Rev 4.0

IMPORTANT FACTS All electric motors, including fan motors make some noise and may feel hot to touch - this is not a fault. Ceiling fans tend to move during operation as they are not generally rigid-mounted. Rigid mounted ceiling fans generate excessive vibration and stress on their mountings. Movement of a couple of centimetres is quite normal and does not suggest the fan will fall down. Please note - all ceiling fans are not the same, even in the same model some may move more or less than others. Fan lights can rattle, if they are not supplied with the fan. They are not covered by warranty. FAN OPERATION A ceiling fan is an environmentally smart choice when it comes to cooling as well as helping to warm your room. You should see a reduction in both cooling and heating costs by regular use of your fans. Do not hesitate to use your fans in both summer and winter months. In summer place the reverse switch in the downward position (fans should spin in anti clockwise direction) so cool air is blowing down producing a cool breeze. In winter, reverse the switch (fan should spin in clock wise direction) so that an upward airflow will push warm air off the ceiling and circulate it downwards into the living areas. In winter months use the fan on a lower speed than in summer. Make sure fan is off and blades have stopped spinning before changing the summer/winter switch. NORMAL WEAR AND TEAR. Threaded components working slightly loose, or blade carriers becoming slightly bent due to vigorous cleaning or bumping can cause extra wobble and noise. This is not covered under warranty, but a little care and maintenance can reduce or prevent this problem. NIGHT NOISES This is the biggest cause of service calls, which are outside the manufacturer s warranty. If a fan has a fault it will be noticeable at all times. Naturally when everything is quiet at night you will be more inclined to hear small noises, which may not be noticeable at other times. Even slight signals super imposed in your electricity supply for off peak hot water control may cause a change in the fan motor noise. This is normal. 12 Rev 4.0