Living Air Electronic Air-Purification Systems

Similar documents
Eagle 2500 TM OWNER S MANUAL. Electronic Air Purification 110 and 220 volt Systems. EcoQuest International. Application.

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 0905 FAOM15_0905

CA3500, BA3500, CH3500 New Comfort

Electronic Air Purification System

AIR PURIFIER CLASSIC INSTRUCTION MANUAL. CAUTION: Read manual carefully for correct procedures and proper operation.

Electronic Air Purification System 100, 120, 220, and 240 Volt Systems

installation operation specifications features maintenance user guide read these instructions before use save this user guide

FATG OM 0604 OWNERS MANUAL. Anywhere. Everywhere. Fresh Air... To Go.

Air Purification Unit MODEL 300/RHO2 USER GUIDE. Because You Care, Clean the Air

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Multi-Tech S1000 / S1000-Ultra Air Purifier

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Introduction (Thanks / Warnings / Records) Features / Benefits Controls / Diagrams Initial Setup (Placement / Settings) Operations Maintenance

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

3 963/963E Benchtop Air Ionizer Instructions

Eliminator Series. SE400E and SE800E ELECTRONIC AIR PURIFICATION SYSTEM. Electrostatic Precipitators for Commercial Applications

Comefresh CF-8608 Air Purifier

Owners Manual Model: XXL

Instruction Leaflet. 99% HEPA air cleaners MODEL BAP

WARNING CAUTION ATTENTION. Q: What is an ozone alert? Q: How does it compare to air filters? Q: Is ozone safe?

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

Note: Verify that plastic bags are removed from filters, if equipped or installed, before first use (see page 8) CONTENTS

OWNER S MANUAL. Model No. B-16 STAND PET DRYER

Multi-Tech S5000 Air Purifier

INSTALLATION, OPERATION AND SERVICE MANUAL MIGHTY ION MODEL MI SERIES

Models 30755, & (remote included) Replacement Filter Information

Surgically Clean Air Inc.

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

SHARPER IMAGE. Professional Electrostatic Air Purifier with Permanent Stainless Steel Filter Model: and USE AND CARE GUIDE

Models & Replacement Filter Information

Please read this manual carefully before use to ensure proper usage and save

Model & Replacement Pre-Filter Information Model Pre-Filter F Hunter Fan Company

BioZone AirCare. The AirCare series contains the following units:

User Manual Manual del usuario Guide d utilisation. Blueair 400 Series

HEPA Air Purifier with Ion Flow Technology

READ AND SAVE THESE INSTRUCTIONS. SE400E & SE800E Smoke Eliminator. TRION

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

EAC ELITE ELECTRONIC AIR CLEANER INDOOR AIR QUALITY ENGINEERING DATA FEATURES

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Operation And Maintenance Manual MODEL SSC-7 SEMI-FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

ELECTRONIC AIR PURIFIER

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

INDUSTRIAL ELECTROSTATIC AIR CLEANER MODEL: SH-SSP-300

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

Get Cleaning... User Guide Vax Service line AU: NZ: Bagged Cylinder What s your Vax s model number?

7. CARE AND MAINTENANCE

Bench Top Ionizer Installation, Operation and Maintenance

Replacement Filter Information

instructions for use Air Purifier with ionizer _00/

TRION Air Purification systems

Kitchen Exhaust Fume Solutions CFM ELECTROSTATIC AIR CLEANER

HEPAtech. Air Purifier. English. Owner s Manual. Model Hunter Fan Co.

Design Manual Installation Operation Maintenance

INSTALLATION AND OPERATIONS MANUAL

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

infrared paraffin / kerosene / diesel heater

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

Bring Mountain Freshness Indoors

Ozone Generator Air Purifier HE-500/O3

Residential Duct Mount Builder s Box Media Air Cleaner

Installation and Operation Manual

AIR PURIFIER OZONE GENERATOR

IMPORTANT INSTRUCTIONS OPERATING MANUAL

Model LA-2SP. Air Purification Unit. User Guide. Bring Freshness Indoors

Blueair Pro User Manual

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

GENANO AIR PURIFICATION TECHNOLOGY

UV PRO 15, ozone generator instruction manual ****IMPORTANT****

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

AIR PURIFIER WITH GERMICIDAL UV LIGHT

TA-12. Tabbing System USER'S GUIDE

ELECTRONIC AIR CLEANERS

BioZone Scientific International contact information

F112A,C; F113A,C Portable Air Cleaners

WHYNTER Eco Pure Air Purifier

M-11 Series. Installation and Service Manual

OPERATION INSTRUCTION

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

Owner s Manual. Table of Contents

RINGMASTER 5-1/2 & 7 COTTON CANDY MACHINE

Operation and Maintenance Manual 120V/60HZ

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

Clean Air Optima HEPA UV ionizer air purifier CA-508

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

Instruction Leaflet. pure indoor living MODEL: BAP1502WO-CN. filter series AIR PURIFIER WITH ODOR ELIMINATOR FILTERS

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

AIR PURIFIER MODEL NO: APA240 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC1114

Heat Recovery Ventilation Systems OWNER S GUIDE

ultrasonic diffuser diffuseur ultrasonique

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

PA / PA-PRO PORTABLE AIR PURIFIER Instruction Manual

OPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45

Ultra Lightweight Household & Commercial Vacuums

PP Owner s Manual

Transcription:

Living Air 310 T. Elmer Cox Drive Greeneville, TN 37743 800/989-2299 Owners Manual Living Air Electronic Air-Purification Systems Model EPI *Installation *Operation *Maintenance *Warranty Caution: Read manual carefully for proper procedures and operation.

Model EPI CONTENTS: OUTSTANDING FEATURES 3 MODEL SPECIFICATIONS 3 INSTALLATION 4 PRINCIPLES OF OPERATION 4-5 PLACING THE UNIT 5 ADJUST/SETTING THE UNIT CONTROLS 6 APPLICATIONS 6 MAINTENANCE AND TROUBLESHOOTING 6-7 WARRANTY INFORMATION 7 Please record the serial number of your Living Air Model EPI below: Serial # 2

OUTSTANDING FEATURES COMPACT NO DUCT WORK REQUIRED NO CHEMICALS NO INSTALLATION REQUIRED NO RESIDUAL CONTAMINATION PORTABLE PLUGS INTO 110 VOLT OUTLET LOW ELECTRICAL USE LOW MAINTENANCE COMPLETE USER CONTROL MODEL EPI SPECIFICATIONS *Negative and positive ion generation Features: Adjustable fan speed control Washable permanent lint filter Fixed and balanced DC ion output circuit Electrical: 120 volt 60hz ac line operation Less than 30 watts power consumption 12 KV DC ion generator Mechanical: 400 CFM free air delivery fan Front access control for governing fan speed Size: Height 11 3/4"; width 8"; depth 9 3/4" Weight 21 pounds Warranty: 3 years parts and labor 3

INSTALLATION AND INSPECTION OF MODEL EPI -Remove unit from shipping carton -Remove all protective materials -Check for shipping damage or loose or broken parts -Plug the unit into a 110 volt outlet and adjust controls according to the application. (See: "Placement of unit" and "Adjust/setting unit controls".) PRINCIPLES OF OPERATION Nature cleanses the air with the lightning and the rain. Lightning bolts produce positive and negative ions which cleanse the air naturally. Rain helps bring ions closer to the earth's surface. The ions are then attracted to atmospheric contaminants and either removed from the air, or attached to grounded objects. The Living Air purification Model EPI produces billions of negative or positive ions, which will function in two ways: 1. Airborne particles, contaminates, and pollution are electrically charged, precipitated together, and they adhere to a grounded surface or are then heavy enough to be influenced by gravitational forces. 2. Static electricity is directly related to an imbalance between positive and negative ions. The Model EPI will create an equilibrium between the negative and positive charges in very high quantities, thereby reducing the total static electrical imbalance. 4

IONS - INDOOR SPACE TRAVELERS Living Air's ion field generator re-establishes the ratio of negative to positive ions found in the outdoors. Ionized (charged) particles are removed from the air by attraction to solid surfaces. Negative Ion attaches to + particle and drops them from the air Positive (+) and Negative (-) Ions. PLACING THE UNIT Elevate the unit as much as possible to insure complete purification. Some pollutants such as smoke rise and the unit, when elevated, can more effectively eliminate the pollutant. The Living Air Model EPI is most effective when placed in a position that allows the ions to be spread evenly and be thoroughly mixed with the polluted air. Suggested locations, listed in the order of preference: 1) In or near the air stream or current within the room that will best disperse the ions. 2) Nearest the source of the worst pollution. 3) In the area most heavily used to achieve maximum benefit. FOR MAXIMUM CONTROL, THE IONIZER SHOULD BE PLACED WHERE EASY ACCESS TO THE CONTROLS IS POSSIBLE. THE UNIT SHOULD ALWAYS BE PLACED AT LEAST ONE INCH AWAY FROM THE WALL TO ACHIEVE UNRESTRICTED AIR FLOW. 5

ADJUST/SETTING CONTROLS 1. FAN CONTROL The disbursement of ions is best accomplished with good air circulation. The fan control should be set as high as possible without creating an undesirable noise level. This will be determined by personal preference and the distance you wish the ions to be dispersed. APPLICATIONS COMPUTER ROOMS ANIMAL DANDER COPY ROOMS SAW DUST AIRBORNE BACTERIA DUST STATIC ELECTRICITY PHOTO LABS PRINTERS AGRICULTURE DUST FEATHER DUST SMOKE PLASTIC OPERATIONS * AND MANY OTHERS The Living Air Model EPI is designed for heavy duty removal of airborne particles and pollution from the air. The system is effective in the range of air movement. The use of auxiliary air moving equipment such as fans and recirculation equipment will help to increase its effective range. The Model EPI will cover approximately 1500 square feet without auxiliary air movement. MAINTENANCE/TROUBLESHOOTING Rear screen of filter cleaning - When visibly dirty, remove the filter screen from the back of the unit and wash it with warm soapy water. Dry completely before reinstalling. DO NOT WASH IN A DISHWASHER! 6

The Ion Generator - The electronic ionizer may need periodic cleaning of the needles. Energy may be stored in the circuitry, even though the unit is unplugged. Discharge each set of needles to a grounded object by using a wire with an inch of insulation stripped from each end. Connect one end of the wire to a grounded object, such as a water pipe, and touch the other end to each set of needles. (Remove 2 screws at the base of each ion needle assembly for easier access to the needles.) Clean them with a cotton swab and alcohol. The indicator lights inside the A unit will not light if the ions are not being produced; however, the fan may continue B to operate. Figure A represents assembled needles. Figure B represents disassembled needles. Cleaning the fan - The fan requires no maintenance except on rare occasion it may be necessary to give it a gentle push the first time it is used. If the fan squeaks, a drop of lightweight oil may be needed on the fan shaft. Troubleshooting - What to look for first Is the unit plugged in? Are you sure the outlet is active? Is the unit off/on switch activated? Is the rear filter screen installed properly to depress the safety switch? Warranty Living Air Purification Products are of solid state construction and carry a full three- year limited warranty, from the date of purchase, to be free from defect in materials and workmanship. See warranty card. 7

Copyright 1998 Alpine Industries All rights reserved