INSTALLATION AND OPERATING INSTRUCTIONS DÜRR DAYLIGHT LOADER DL 24, DL 26, DA 24

Similar documents
Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Periomat Plus. Installation and Operating Instructions / /08

POLYMIX PX-IG 2000 Operating Instructions

Dürr Dental X-ray Film Developer XR 24 Pro

SHORT WAVE INFRARED PANEL DRYER

INTERNATIONAL STANDARD

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

INTERNATIONAL STANDARD

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

1www.blackanddecker.co.uk

VC 45 Surgical Suction Unit

Table of Contents. English

Model Number Structure

Operating Instructions

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

AirStar Clinical Air Compressor AS60, AS90 and AS120. Installation & Operating Instructions

Dyna-Form Air. Alternating Pressure Relief Overlay System

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

CombiGrinder. Instruction manual. Grinder for cattle, horse and pet clipper blades. swiss made. Version/Index: CombiGrinder/A 09-16

EtherCAT Box Modules (EPxxxx-xxxx)

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

SSJ 4050NP. EN Slow Juicer. Copyright 2017, Fast ČR, a.s

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Pressurized Filter Up to 1250 gallons

INTELLIHEAT LUXURY FOOTWARMER TYPE G0002

Ireland Australia New Zealand

CPX RIGID PENDANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

AS 500. Instructions for Use. Version 1.0. December

Masticating Slow Juicer

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

Operating Manual. VIENNA Hot Display

NV3610N NV7210N NV9610N.

Operating instructions (translation) Stunning Device for Small Animals

Blender. brushed stainless steel housing BTBL55

NEPTUN I Sole cleaning unit Art.-No.:

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

ENGLISH USER S MANUAL PRE SOAKER 3600

EN Z Subject to change due to technical improvements! Operating instructions

USER GUIDE. Intra - X Intra - XE. Operation and Maintenance manual. Automatic X-Ray Film Processor

No Touch Thermometer

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

XR 24 NDT. Manual /30

Operating instructions Page 6. Refrigerator Read the operating instructions before switching on for the first time

BENSON LINEAR RADIANT TUBE

Tornado Operations & Maintenance Manual

A measured step forward

INSTALLATION AND OPERATING INSTRUCTIONS DÜRR XR 24 PRO X-RAY FILM DEVELOPING APPLIANCE

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

FloorXcenter. Floor cleaning machine. Operation Instructions. Content:

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Operating instructions Page 8. Freezer G_

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Read these instructions before using and keep them available at all times!

Operating instructions Page 12. Wine storage cabinet WKt

Energy management function at adsorption dryer PDAD

Multifunction Electric Can Opener

DV7215EL DV1015EL DV1415EL DV1815EL.

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6

Protégé Eclipse LED Keypad User Manual PRT-KLES

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

V80-H Multistage Pump Instruction Manual

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Paralda Air Purifier USER MANUAL

INSTALLATION INSTRUCTIONS FOR FLUE KIT

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Service package PDAD- -SP (en) Assembly instructions d [ ]

XT Series Thermostats

Installation manual plugs and connectors QUICK-CONNECT (63 A)

INSTRUCTIONS AND WARRANTY

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

Operating instructions Page 12. Freezer Read the operating instructions before switching on for the first time GGU 15

1.5L slow cooker XJ instruction manual. High. Low. Off MONTH WARRANTY

Remote alarm case VENTIremote alarm 10 m WM VENTIremote alarm 30 m WM Device description and instructions for use

Part No KEMPER Filter-Master XL

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

Amalgam separator CA 4

Operating instructions Page 7. FDv 4613 / FDvb 4613 / FDv 4643 / FDvb 4643 / Fv 3613 / Fvb 3613 / Fv 3643 / Fvb 3643

ANNEX GD-CERT-EX-EN SIT

15 20 kw kw kw

Fig. 2. Fig. 1. Fig. 3. Fig. 4. Fig. 5. Fig. 7 Fig. 6. Fig. 9. Fig. 8. Fig. 10 MAX H2O

Installation and Operating Instructions. Models: T4-12LOW-9IS

Please read operating instructions carefully before use and keep for further reference.

Read these instructions before using and keep them available at all times!

Operating instructions Page 8. Chest freezer

Operating instructions Page 6. Commercial refrigerator Read the operating instructions before switching on for the first time

FTA-1 Aspirator with trap flask

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

SOVEREIGN W Grass Trimmer (Model: GT2317) Instruction Manual. Important - Please read these instructions fully before starting assembly

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Safety Warnings. Work area safety. Electrical Safety. Personal Safety

Transcription:

INSTALLATION AND OPERATING INSTRUCTIONS DÜRR DAYLIGHT LOADER DL 24, DL 26, DA 24 2005/05

2

CONTENTS Important Information 1. Notes... 4 1.1 Conformity... 4 1.2 General Notes... 4 1.3 General Safety Notes... 4 1.4 Warning Information and Symbols... 5 2. Product information... 6 2.1 Use for the Intended Purpose... 6 2.2 Use other than that for the intended purpose... 6 2.3 Product Description... 6 3. Delivery Contents... 6 4. Technical Data... 6 4.1 Measurements... 6 Installation 5. Sleeve Attachment... 8 5.1 Mounting adjustable feet... 8 5.2 Installation note... 9 5.3 Attaching seal... 9 Use 6. FilmProcessing... 10 7. Film Storage... 10 3

1. NOTES IMPORTANT INFORMATION 1.1 Conformity This product was tested according to the guidelines as laid down in 93/42/EWG of the European Union. This product has been shown to conform to all the fundamental requirements as per these guidelines. 1.2 General Notes The installation and operating instructions are part of the appliance. They should always be at hand near the unit. Correct observation of these instructions is a prerequisite for correct usage and handling of the appliance. New colleagues should be made aware of the contents. These instructions should be handed over to any subsequent owner or user of the appliance. The safety of operators and trouble-free operation of the appliance can only be guaranteed when original parts are used. Furthermore, only parts as listed in the technical documentation or parts explicitly approved by Dürr Dental may be used. Dürr Dental cannot guarantee either troublefree operation or functional safety where parts or products from other manufacturers are used. No claims for compensation of any kind will be accepted, where damage results from the use of parts or products from other manufacturers. Dürr Dental does not accept responsibility for the safety, reliability and function where installation, resetting, alterations, additions or repairs have not been carried out by either Dürr Dental or by a responsible party authorized by Dürr Dental, and where the appliance has not been used in accordance with the operating instructions. The installation and operating instructions are designed for this appliance and conform to the techno-logical standard valid at the time the appliance was first used. All switches, processes, trade marks, software programs and appliances named in this document are registered names. Copying of all or part of the technical documentation is subject to the prior approval of Dürr Dental. 1.3 General Safety Notes This appliance has been so designed and constructed by Dürr Dental that virtually no possible danger can arise provided it is installed and operated according to the instructions. However, in order to avoid any possible damage or injury we feel obliged to point out the following safety measures. When operating this appliance observe all local and national rules and regulations! Converting or altering this appliance in any way is not permitted. Dürr Dental cannot provide any guarantee or admit liability where any modifications have been carried out. In the interests of ensuring problem-free running the owner and operator are responsible for observing all rules and regulations. Retain all packing material in case the device must be returned to the manufacturers. Take care that it does not fall into the hands of children. Only the original packing guarantees optimal safety of the appliance during transport. Should it be necessary to return the product to the manufacturer during the guarantee period, Dürr Dental will not accept claims for damage arising from using incorrect packing materials! This product is a medical technical appliance and may only be used by those persons whose training and/or experience guarantees correct usage. Before each use of the appliance the operator should check both the safety and that it is in fully working order. The operator must be fully aware of how to use the appliance correctly. 4

This product is not suitable for use in areas of medical rooms where there is the danger of explosion. Examples of unsuitable operating rooms are those where combustible anesthetics, skin-cleaning agents, oxygen or skin disinfectant materials are present. The appliance is not to be used in rooms with combustible-inducing atmospheres. 1.4 Warning Information and Symbols In the Installation and Operating Instructions use is made of the following terms or symbols to denote information of special importance. Information and/or mandatory regulations or prohibitions for the prevention of personal injury or substantial property damage Special information regarding the economical use of the equipment and other information Observe Installation and Operating Instructions! For the protection of both staff and patients, protective gloves must be worn when using X-ray processors 5

2. PRODUCT INFORMATION 2.1 Use for the Intended Purpose Dürr Dental daylight loaders DL 24, DL 26 and daylight attachment DA 24, are only designed to be used in conjunction with the X- ray processors XR24 etc. The daylight loaders DL 24 and DL 26 are attached where no darkroom is present. The daylight attachment DA 24 can be integrated where a darkroom already exists; the darkroom can be more rapidly exited after introduction of the X-ray film into the processor. 1 2.2 Use other than that for the intended purpose Any other use or use beyond what is specified is deemed to be not for the intended purpose. The manufacturer accepts no liability for damage resulting therefrom. All risk is borne solely by the user. 2.3 Product Description DL 24 and DL 26 allow the sleeves to be used as preferred, i.e. from in front or from the side, as illustrated in figs. 1-2. Daylight attachment DA 24 does not have sleeves. 3. DELIVERY CONTENTS 2 DL24 (with red filter pane)... 1700-910-00 for intra- and extra-oral dental films or DL26 (with red filter pane)... 1700-920-00 e.g. for 24x30 films in cassette holder or DA24 (without red filter pane)... 1700-930-00 without sleeves 4. TECHNICAL DATA 4.1 Measurements DL24 W = 28cm, L = 43cm, H = 38cm DL26 W = 43cm, L = 43cm, H = 38cm DA24 W = 28cm, L = 43cm, H = 38cm 3 6

7

4 INSTALLATION 4 5 1 3 2 5. SLEEVE ATTACHMENT The side panels with the sleeves (2) can be mounted as desired Remove screws from cover DL24: 4 screws (4) DL26: 6 screws (4) Remove lid (1) of daylight loader The side panels with the sleeves (2) are lifted vertically and exchanged with the appropriate side panel (3) as preferred 5.1 Mounting adjustable feet Attach daylight loader DL24/DL26 or daylight attachment DA24 in place. Place the threaded sleeve (5) as supplied into the daylight loader or daylight attachment: for DL 26 in the two central inside sockets, for DL 24 in the two outside sockets. Place the threaded sleeve (5) with the threaded flanges to the bottom onto the adjustable foot (6) and rotate approx. 3 times. The sleeve should not be screwed onto the foot too far, otherwise the sleeve cannot be placed properly into the daylight loader or daylight attachment. Place the sleeve together with foot into the molding of the daylight loader or daylight attachment. See Fig 5. 6 5 8 6

5.2 Installation note Fix the daylight loader or daylight attachment to the X-ray processor XR24 using the 4 quicklock screws (7) at the back of the processor. Turn the quick-lock screws clockwise until they click in place! 7 7 Place the cassette holder (8) right or left on the floor of the daylight loader as desired. 8 8 9 10 5.3 Attaching seal After installation of the daylight loader the seal must be placed in position: Open the cover of the daylight loader. Place the seal (10) of the film feed (9) in position on the X-ray processor. The side with moldings should be to the bottom. In order to avoid faulty exposures press the seal firmly in place. After successful installation of the daylight loader test that it totally excludes all light. 9 9

USE 11 6. FILMPROCESSING During processing of thin layer (Extraoral) films, lid (11) must be completely closed otherwise films will be pre-exposed 10 11 12 13 7. FILM STORAGE The film depot (13) can be used to store a maximum of 10 extra-oral films. For the protection of both staff and patients, protective gloves must be worn when using X-ray processors. When storing film in the film depot (13) the following must be observed: Use up all films once a pack has been opened! This prevents films from being stored for too long and avoids the consequent grain effect on such film material. For films in the formats 12 x 30, 13 x 18, 15 x 30 hang the film holder (12) in the film depot (13). Place the film material in the film holder (12) For films in the format 24 x 30 or 24 x 18 the film holder is not required. Place the film material in the film depot (13); 24 x 18 films should be placed vertically in position Close the lid of the film depot (13) after every removal of a film; otherwise there is the danger of a double exposure. 10