Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE What You Measure, We Manage
ABOUT US ABOUT US DRM Technic is a global manufacturer and supplier of gas analysis solutions and gas detection products. We provide expert solutions to our clients which range from small independents to global manufacturers. We offer unrivalled customer service which is supported by our unique guarantee, and implemented by our valued, motivated and skilled team. We believe in quality, honesty and reliability. It is our vision to be our customers preferred full service provider (including installation, spares and service) and to create and maintain strong, valued and trusted relationships with all of our customers. PURCHASE OPTIONS We accept cheques, credit/debit cards and electronic bank payments. We also offer monthly credit accounts, subject to status. We are an established exporter and are pleased to offer a complete export service for our large product range. We can export our products worldwide. CONTACT DETAILS Address: DRM Technic Ltd, 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB, UK Telephone: +44 (0)1782 638491 Email: sales@drmtechnic.com 2
Heated Sample Lines Contents CONTENTS Probe Finder 4 GAS 222.15 5 GAS 222.17 6 GAS 222.20 7 GAS 222.20 ATEX 8 GAS 222.20 ATEX 2 9 GAS 222.21 10 GAS 222.21 ATEX 11 GAS 222.21 ATEX 2 12 GAS 222.31 13 GAS 222.31 ATEX 14 GAS 222.31 ATEX 2 15 GAS 222.35 16 GAS 222.35 ATEX 17 GAS 222.35 ATEX 2 18 RSS 24 / RSS 230 Blowback Controllers 19 GAS 222 Accessories 20 3
PROBE FINDER Non-Hazardous Areas Both Hazardous Areas Dust Concen. Filter Type Heated; Self-Regulated Heated; Regulated Unheated Heated Zone 1 Heated Zone 2 Max Process Temp. Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 200 o C GAS 222.15 GAS 222.20 GAS 222.10 GAS 222.20 ATEX GAS 222.20 ATEX 2 Up to 2 g/m 3 downstream filter GAS 222.17 GAS 222.21 GAS 222.11 GAS 222.21 ATEX GAS 222.21 ATEX 2 1600 o C - - Steam Heated GAS 222.20 DH - - > 2 g/m 3 in-situ filter - GAS 222.31 GAS 222.30 GAS 222.31 ATEX GAS 222.31 ATEX 2 1000 O C > 2 g/m 3 in-situ and downstream filter - GAS 222.21 - GAS 222.21 ATEX GAS 222.21 ATEX 2 1000 o C > 2 g/m 3 easy remove in-situ filter - GAS 222.35 GAS 222.35U GAS 222.35 ATEX GAS 222.35 ATEX 2 600 o C Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 120 o C > 2 g/m 3 in-situ filter - - ECO-01 - - 260 o C Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 600 o C > 2 g/m 3 in-situ filter - - APO - - 600 o C 4
GAS 222.15 GAS 222.15 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, allowing them to be easily adaptated for applications with specific requirements. The probes are assembled-to-order, easy to install and have low operational costs. Heated with Downstream Filter Easy Filter Element Replacement Effective Insulation and Protection Shield Self-Regulating with Low Temperature Alarm For Dust Concentrations of up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.15 1.4571 SS Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 115/230 V, 50/60 Hz Temperature +180 C (Self-regulating) Contact is open at Low Temp. Alarm operating temperature, closes at < 140 C, current max. 4 A Ambient Temp. -20 to + 80 C 5
GAS 222.17 GAS 222.17 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, allowing them to be easily adaptated to application specific requirements. The probes are assembled-to-order, easy to install and have low operational costs. Heated Probe with Downstream Filter and Weather Protection Shield Self-Regulating Up to 180 C with Low Temperature Alarm For Dust Concentrations of Up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.17 1.4571 SS Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 115/230 V, 50/60 Hz Temperature Self-regulating; +180 C Contact is open at Low Temp. Alarm operating temperature, closes at < 140 C, current max. 4 A Ambient Temp. -20 to + 80 C 6
DRM Technic -- Sample Probes -- Sample Probes GAS 222.20 GAS 222.20 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Downstream Filter and Weather Protection Shield Electronic Heater (up to 200 C) with Low/High Temp. Alarm & Display Easy Filter Replacement Effective Insulation and Protection Shield For Dust Concentrations up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.20 1.4571 SS Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; + 5... 30 K Alarm from set point; factory set 15 K, max. current 1 A Protection Class - IP54 Ambient Temp. - 20... + 70 C 7
GAS 222.20 ATEX GAS 222.20 ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated with Downstream Filter, Weather Protection Shield and Junction Box Easy Filter Element Replacement C-US and CSA Approval For Dust Concentrations of up to 2 g/m³ Self-Regulating at up to 130 C (T3) / 70 C (T4) Product No. Max. Flow Rate Max. Inlet Temp. Process Media GAS 222.20 ATEX 1.4571 SS Graphite, 1.4404 SS + filter elements 1000 l/h 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60 Hz Type C: External Circuit Breaker 2A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature -20 to 50 C Temperature Self-regulating; approx. 80 C Ex-marking of the basic unit 1 GD / 2 GD T4 T130 C 8
DRM Technic -- Sample Probes -- Sample Probes GAS 222.20 ATEX 2 GAS 222.20 ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated with Downstream Filter and Weather Protection Shield Effective Insulation and Protection Shield For Dust Concentrations of up to 2 g/m³ Self-Regulating at up to 130 C (T3) / 70 C (T4) Specified for Use in Hazardous Areas Product No. GAS 222.20 ATEX 2 1.4571 SS Graphite, 1.4404 SS + filter elements Heater 115-230 V, 50/60 Hz Temperature Self-regulating; + 130 C (T3) / + 70 C (T4) Contact is open at operating temperature; Low Temperature Alarm closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C II 3G EEx na L IIC T3 3G c IIC T3 II 3G EEx na L IIC T4 3G c IIC T4 9
GAS 222.21 GAS 222.21 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated with Shut Off Valve, alongside an In-Situ and/or Downstream Filter Tool-less Downstream Filter Element Replacement Effective Insulation and Protection Shield Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.21 1.4571 SS; ball valve: 1.4408 SS PTFE, Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; + 5... 30 K Alarm from set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp. - 20... + 70 C 10
DRM Technic -- Sample Probes -- Sample Probes GAS 222.21 ATEX GAS 222.21 ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with In-Situ / Downstream Filter and Weather Protection Shield Tool-less Filter Replacement Self-Regulating at up to 90 C For Dust Concentrations of up to 2 g/m³ with In-Situ Filter and 10 g/m³ with In-situ and Downstream Filters ATEX Certified Product No. Max. Flow Rate Max. Inlet Temp. Process Media GAS 222.21 ATEX 1.4571 SS; ball valve: 1.4408 SS PTFE, Graphite, 1.4404 SS + filter elements 1000 l/h 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 90 C External Circuit Breaker Type C: 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Filter Type In-situ and/or downstream Ex-marking of the Basic Unit. 1 GD / 2 GD T4 T130 C 11
GAS 222.21 ATEX 2 GAS 222.21 ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, plus an In-Situ and/or Downstream Filter Easy Tool-less Filter Element Replacement Effective Insulation and Protection Shield Self-Regulating at up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of up to 2 g/m³ ATEX Certification Product No. GAS 222.21 ATEX 2 1.4571 SS ball valve: 1.4408 SS Graphite, 1.4404 SS + filter elements Temperature Self-regulating; 130 C (T3) / 70 C (T4) Low Temperature Alarm Contact is open at operating temp.; closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C Pressure Shut-Off Valve 6 to 8 bar Suitable for II 3G EEx na L IIC T3; 3G c II C T3; II 3G EEx na L IIC T4; 3G c IIC T4 12
DRM Technic -- Sample Probes -- Sample Probes GAS 222.31 GAS 222.31 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, In-Situ Filter and Weather Protection Shield Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of Up to 200 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.31 1.4571 SS; ball valve: 1.4408 SS PTFE, Graphite, 1.4404 SS Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; + 5... 30 K Alarm from set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp. - 20... + 70 C 13
GAS 222.31 ATEX GAS 222.31 ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, Internal Filter and Weather Protection Shield Self-Regulating at Up to 90 C For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS 222.31 ATEX 1.4571; ball valve: 1.4408 PTFE, Graphite, 1.4404 SS Max. Flow Rate 1000 l/h Max. Inlet Tempertature Process Media 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 90 C Type C: External Circuit Breaker 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Filter Type In-situ Ex-Marking of the Basic Unit 1 GD / 2 GD T4 T130 C 14
DRM Technic -- Sample Probes -- Sample Probes GAS 222.31 ATEX 2 GAS 222.31 ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated with Shut-Off Valve, In-Situ Filter and Weather Protection Shield Self-Regulating at Up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS 222.31 ATEX 2 1.4571 SS; ball valve: 1.4408 SS PTFE, Graphite and 1.4404 SS Self-regulating; Temperature + 120 C (T3) / + 70 C (T4) Contact is open at operating temperature; closes at < 95 C (T3) Low Temperature Alarm resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C II 3G EEx na L IIC T3; 3G c IIC T3; Suitable for II 3G EEx na L IIC T4 ; 3G c IIC T4 15
GAS 222.35 GAS 222.35 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with an In-Situ Filter and Weather Protection Shield Tool-less Filter Replacement Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of Up to 200 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.35 1.4571 SS Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Range 50 to 200 C Adjustable; 5... 30 K from Alarm set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp. - 20... 70 C 16
DRM Technic -- Sample Probes -- Sample Probes GAS 222.35 ATEX GAS 222.35 ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with In-Situ Filter and Weather Protection Shield Tool-less Element Replacement Self-Regulating at Up to 80 C For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS 222.35 ATEX 1.4571 PTFE, Graphite, 1.4404 SS + filter elements Max. Flow Rate 1000 l/h Max. Inlet Temperature Process Media 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 80 C Type C: External circuit breaker 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Ex-Marking of the Basic Unit 1 GD / 2 GD T4 T130 C 17
GAS 222.35 ATEX 2 GAS 222.35 ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated Probe with an In-Situ Filter and Weather Protection Shield Self- Regulating at Up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS 222.35 ATEX 2 1.4571 SS PTFE, Graphite,1.4404 SS + filter elements Voltage 115-230 V, 50/60 Hz Temperature Self-regulating; + 125 C (T3) / + 70 C (T4) Contact is open at operating temperature; Low Temperature Alarm closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C Suitable for II 3G EEx na L IIC T3; 3G c IIC T3; II 3G EEx na L IIC T4; 3G c IIC T4 18
DRM Technic -- Sample Probes -- Sample Probes RSS 24 / RSS 230 Blowback Controllers RSS 24 / RSS 230 BLOWBACK CONTROLLERS The Blowback Controllers RSS 24 and RSS 230 are meant for controlling the cleaning cycles of a probe filter. They are designed for use with probe types GAS 222.30, GAS 222.31 and ECO-01, but may also be used to control other external valves. Programmable Blowback / Sample Time Status Control Wall Mounted Product No. RSS 24 RSS 230 Power Supply 24 V DC ± 10% 85-265 V AC 50/60 Hz Fuse 5 A (slow) 1 A (slow) Relais Output Max. 10 A / 24 V DC / 75 W Max. 10 A / 230 V AC / 690 VA Ambient Temperature 0-55 o C 0-55 o C Blowback Time 0-60 s 0-60 s Sample Time 1 min - 99:59 h 1 min - 99:59 h Protection Class IP 65 IP 65 Weight Approx. 3 kg Approx. 3 kg Dimensions (H x W x D mm) 300 x 300 x 180 300 x 300 x 180 TIME FLOW DIAGRAM For more information, please feel free to contact our sales department 19
GAS 222 Sample Probe Accessories GAS 222 SAMPLE GAS PROBE ACCESSORIES We have a large range of Accessories for GAS 222 Sample Gas probes. See below for our Blowback Accessories, including Capacitive Vessels, Pneumatic Actuators, 3/2-way Solenoid Valves and Blowback Controllers. Overleaf are the details of our Sample Tubes, In-Situ Filters, Protection Sheilds and Extensions, all available in various materials, in various dimensions, and as heated and non-heated versions. 20
DRM Technic -- Sample Probes -- Accessories GAS 222 Sample Probe Accessories 21
DRM Technic Ltd 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB United Kingdom Tel: +44 (0)1782 638491 Email: sales@drmtechnic.com