Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE. What You Measure, We Manage

Similar documents
SITRANS F M MAG 3100 P:

OilSET-1000 (12 VDC)

Snifter ATEX22 VERSION. User Manual. Distributor

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Gas cooler series TC-Standard+ X2

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Reliably Advanced Extinguishing Control

Dräger Polytron 7000 Fixed gas detector

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

SET-2000 Hi Level/Oil

Reliably Advanced Extinguishing Control

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

SET Installation and Operating Instructions. Level switch for one sensor

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger Polytron Pulsar 2 Open Path Gas Detector

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Hazardous Area Zirconia Oxygen Systems

Certification Supplement Manual

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Technical Specification VFD

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Gas cylinder scale Model GCS-1

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

Sample Gas Probes Series GAS 222

Building Services Brochure

Dräger Polytron 5720 IR Detection of carbon dioxide

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

Condensate drains WA/PWEA

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

BKA-EN Fire Damper. Additional operating instructions according to

Autocalibration Systems for In Situ Oxygen Analyzers

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

Certification Supplement Manual

Rotameter series 250 metal tube variable area flowmeter

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

BSK-RPR Fire Damper. Additional operating instructions according to

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

Dräger Polytron 5700 IR Detection of flammable gases and vapours

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Illumination unit For sight glass level indicator Model LGI

Integrated Solutions Low Voltage Systems

AUDIBLE SIGNALIZATION

MICROSENSE FLOW SWITCH

DESCRIPTION. 42 mm. 125 mm

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Inductive slot sensor

Technical Data. Dimensions

Dual-point heat-tracing control system

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

COMPACT FLAME CONTROLLER CFC 2000

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Dräger Polytron 5720 IR Toxic Gas Detection

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Zircomat Oxygen Analyzers

Ar-Mite TM Low Flow Armored Flowmeter

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Instrumentation Products and Applications

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Instrumentation for Nuclear Applications

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

POWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Continuous level measurement Ultrasonic transmitters

COMPACT FLAME CONTROLLER CFC 1000

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

RAYCHEM NGC-30 COMPONENTS

Gas cooler series RC 1.1

Enraf Servo Gauge 854 XTG

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

INSTRUCTION MANUAL. Change Over Unit ECO for ETC 24R MOBATIME BE

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Portable sample gas conditioning PCS.smart+

Products Overview. Your trusted partner in process instrumentation

Ultrasonic Level Measurement nivopuls FDU 10 S

Gas cooler series TC-Standard+

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Centro-Matic Automated Lubrication Systems System Controls

Compressed air treatment. Condensate drains OMEGA AIR

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

Peristaltic condensate pumps CPsingle, CPdouble X2 (Versions with ATEX 2, IECEx and Cl.1 Div.2 approval)

Bristol Babcock Oil Content Monitor "oil in water"

PEPPERL+FUCHS GmbH

Rittal roof-mounted fans Efficiency on top

Transcription:

Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE What You Measure, We Manage

ABOUT US ABOUT US DRM Technic is a global manufacturer and supplier of gas analysis solutions and gas detection products. We provide expert solutions to our clients which range from small independents to global manufacturers. We offer unrivalled customer service which is supported by our unique guarantee, and implemented by our valued, motivated and skilled team. We believe in quality, honesty and reliability. It is our vision to be our customers preferred full service provider (including installation, spares and service) and to create and maintain strong, valued and trusted relationships with all of our customers. PURCHASE OPTIONS We accept cheques, credit/debit cards and electronic bank payments. We also offer monthly credit accounts, subject to status. We are an established exporter and are pleased to offer a complete export service for our large product range. We can export our products worldwide. CONTACT DETAILS Address: DRM Technic Ltd, 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB, UK Telephone: +44 (0)1782 638491 Email: sales@drmtechnic.com 2

Heated Sample Lines Contents CONTENTS Probe Finder 4 GAS 222.15 5 GAS 222.17 6 GAS 222.20 7 GAS 222.20 ATEX 8 GAS 222.20 ATEX 2 9 GAS 222.21 10 GAS 222.21 ATEX 11 GAS 222.21 ATEX 2 12 GAS 222.31 13 GAS 222.31 ATEX 14 GAS 222.31 ATEX 2 15 GAS 222.35 16 GAS 222.35 ATEX 17 GAS 222.35 ATEX 2 18 RSS 24 / RSS 230 Blowback Controllers 19 GAS 222 Accessories 20 3

PROBE FINDER Non-Hazardous Areas Both Hazardous Areas Dust Concen. Filter Type Heated; Self-Regulated Heated; Regulated Unheated Heated Zone 1 Heated Zone 2 Max Process Temp. Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 200 o C GAS 222.15 GAS 222.20 GAS 222.10 GAS 222.20 ATEX GAS 222.20 ATEX 2 Up to 2 g/m 3 downstream filter GAS 222.17 GAS 222.21 GAS 222.11 GAS 222.21 ATEX GAS 222.21 ATEX 2 1600 o C - - Steam Heated GAS 222.20 DH - - > 2 g/m 3 in-situ filter - GAS 222.31 GAS 222.30 GAS 222.31 ATEX GAS 222.31 ATEX 2 1000 O C > 2 g/m 3 in-situ and downstream filter - GAS 222.21 - GAS 222.21 ATEX GAS 222.21 ATEX 2 1000 o C > 2 g/m 3 easy remove in-situ filter - GAS 222.35 GAS 222.35U GAS 222.35 ATEX GAS 222.35 ATEX 2 600 o C Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 120 o C > 2 g/m 3 in-situ filter - - ECO-01 - - 260 o C Max. Allowed Operating Pressure: Max. Probe Inlet Temperature: 600 o C > 2 g/m 3 in-situ filter - - APO - - 600 o C 4

GAS 222.15 GAS 222.15 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, allowing them to be easily adaptated for applications with specific requirements. The probes are assembled-to-order, easy to install and have low operational costs. Heated with Downstream Filter Easy Filter Element Replacement Effective Insulation and Protection Shield Self-Regulating with Low Temperature Alarm For Dust Concentrations of up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.15 1.4571 SS Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 115/230 V, 50/60 Hz Temperature +180 C (Self-regulating) Contact is open at Low Temp. Alarm operating temperature, closes at < 140 C, current max. 4 A Ambient Temp. -20 to + 80 C 5

GAS 222.17 GAS 222.17 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, allowing them to be easily adaptated to application specific requirements. The probes are assembled-to-order, easy to install and have low operational costs. Heated Probe with Downstream Filter and Weather Protection Shield Self-Regulating Up to 180 C with Low Temperature Alarm For Dust Concentrations of Up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.17 1.4571 SS Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 115/230 V, 50/60 Hz Temperature Self-regulating; +180 C Contact is open at Low Temp. Alarm operating temperature, closes at < 140 C, current max. 4 A Ambient Temp. -20 to + 80 C 6

DRM Technic -- Sample Probes -- Sample Probes GAS 222.20 GAS 222.20 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Downstream Filter and Weather Protection Shield Electronic Heater (up to 200 C) with Low/High Temp. Alarm & Display Easy Filter Replacement Effective Insulation and Protection Shield For Dust Concentrations up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.20 1.4571 SS Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; + 5... 30 K Alarm from set point; factory set 15 K, max. current 1 A Protection Class - IP54 Ambient Temp. - 20... + 70 C 7

GAS 222.20 ATEX GAS 222.20 ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated with Downstream Filter, Weather Protection Shield and Junction Box Easy Filter Element Replacement C-US and CSA Approval For Dust Concentrations of up to 2 g/m³ Self-Regulating at up to 130 C (T3) / 70 C (T4) Product No. Max. Flow Rate Max. Inlet Temp. Process Media GAS 222.20 ATEX 1.4571 SS Graphite, 1.4404 SS + filter elements 1000 l/h 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60 Hz Type C: External Circuit Breaker 2A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature -20 to 50 C Temperature Self-regulating; approx. 80 C Ex-marking of the basic unit 1 GD / 2 GD T4 T130 C 8

DRM Technic -- Sample Probes -- Sample Probes GAS 222.20 ATEX 2 GAS 222.20 ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated with Downstream Filter and Weather Protection Shield Effective Insulation and Protection Shield For Dust Concentrations of up to 2 g/m³ Self-Regulating at up to 130 C (T3) / 70 C (T4) Specified for Use in Hazardous Areas Product No. GAS 222.20 ATEX 2 1.4571 SS Graphite, 1.4404 SS + filter elements Heater 115-230 V, 50/60 Hz Temperature Self-regulating; + 130 C (T3) / + 70 C (T4) Contact is open at operating temperature; Low Temperature Alarm closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C II 3G EEx na L IIC T3 3G c IIC T3 II 3G EEx na L IIC T4 3G c IIC T4 9

GAS 222.21 GAS 222.21 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated with Shut Off Valve, alongside an In-Situ and/or Downstream Filter Tool-less Downstream Filter Element Replacement Effective Insulation and Protection Shield Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of up to 2 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.21 1.4571 SS; ball valve: 1.4408 SS PTFE, Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; + 5... 30 K Alarm from set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp. - 20... + 70 C 10

DRM Technic -- Sample Probes -- Sample Probes GAS 222.21 ATEX GAS 222.21 ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with In-Situ / Downstream Filter and Weather Protection Shield Tool-less Filter Replacement Self-Regulating at up to 90 C For Dust Concentrations of up to 2 g/m³ with In-Situ Filter and 10 g/m³ with In-situ and Downstream Filters ATEX Certified Product No. Max. Flow Rate Max. Inlet Temp. Process Media GAS 222.21 ATEX 1.4571 SS; ball valve: 1.4408 SS PTFE, Graphite, 1.4404 SS + filter elements 1000 l/h 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 90 C External Circuit Breaker Type C: 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Filter Type In-situ and/or downstream Ex-marking of the Basic Unit. 1 GD / 2 GD T4 T130 C 11

GAS 222.21 ATEX 2 GAS 222.21 ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, plus an In-Situ and/or Downstream Filter Easy Tool-less Filter Element Replacement Effective Insulation and Protection Shield Self-Regulating at up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of up to 2 g/m³ ATEX Certification Product No. GAS 222.21 ATEX 2 1.4571 SS ball valve: 1.4408 SS Graphite, 1.4404 SS + filter elements Temperature Self-regulating; 130 C (T3) / 70 C (T4) Low Temperature Alarm Contact is open at operating temp.; closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C Pressure Shut-Off Valve 6 to 8 bar Suitable for II 3G EEx na L IIC T3; 3G c II C T3; II 3G EEx na L IIC T4; 3G c IIC T4 12

DRM Technic -- Sample Probes -- Sample Probes GAS 222.31 GAS 222.31 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, In-Situ Filter and Weather Protection Shield Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of Up to 200 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.31 1.4571 SS; ball valve: 1.4408 SS PTFE, Graphite, 1.4404 SS Max. Operating Temp. 200 C Voltage 230 V, 2.0 A, 50/60 Hz; or 115 V, 3.8 A, 50/60Hz Temperature Range + 50 to +200 C Adjustable; + 5... 30 K Alarm from set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp. - 20... + 70 C 13

GAS 222.31 ATEX GAS 222.31 ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with Shut-Off Valve, Internal Filter and Weather Protection Shield Self-Regulating at Up to 90 C For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS 222.31 ATEX 1.4571; ball valve: 1.4408 PTFE, Graphite, 1.4404 SS Max. Flow Rate 1000 l/h Max. Inlet Tempertature Process Media 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 90 C Type C: External Circuit Breaker 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Filter Type In-situ Ex-Marking of the Basic Unit 1 GD / 2 GD T4 T130 C 14

DRM Technic -- Sample Probes -- Sample Probes GAS 222.31 ATEX 2 GAS 222.31 ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated with Shut-Off Valve, In-Situ Filter and Weather Protection Shield Self-Regulating at Up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS 222.31 ATEX 2 1.4571 SS; ball valve: 1.4408 SS PTFE, Graphite and 1.4404 SS Self-regulating; Temperature + 120 C (T3) / + 70 C (T4) Contact is open at operating temperature; closes at < 95 C (T3) Low Temperature Alarm resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C II 3G EEx na L IIC T3; 3G c IIC T3; Suitable for II 3G EEx na L IIC T4 ; 3G c IIC T4 15

GAS 222.35 GAS 222.35 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with an In-Situ Filter and Weather Protection Shield Tool-less Filter Replacement Electronic Heater (up to 200 C) with Low/High Temperature Alarm and Display For Dust Concentrations of Up to 200 g/m³ Specified for Non-Hazardous Areas Product No. GAS 222.35 1.4571 SS Graphite, 1.4404 SS + filter elements Max. Operating Temp. 200 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Range 50 to 200 C Adjustable; 5... 30 K from Alarm set point; factory set 15 K, max. current 1 A Protection Class IP54 Ambient Temp. - 20... 70 C 16

DRM Technic -- Sample Probes -- Sample Probes GAS 222.35 ATEX GAS 222.35 ATEX SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-to-order, are easy to install and have low operational costs. Heated Probe with In-Situ Filter and Weather Protection Shield Tool-less Element Replacement Self-Regulating at Up to 80 C For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS 222.35 ATEX 1.4571 PTFE, Graphite, 1.4404 SS + filter elements Max. Flow Rate 1000 l/h Max. Inlet Temperature Process Media 135 C Voltage 230 V, 50/60 Hz; or 115 V, 50/60Hz Temperature Self-regulating approx. 80 C Type C: External circuit breaker 2 A for 230 V, 50/60 Hz 3 A for 115 V, 50/60 Hz Ambient Temperature - 20 to + 50 C Ex-Marking of the Basic Unit 1 GD / 2 GD T4 T130 C 17

GAS 222.35 ATEX 2 GAS 222.35 ATEX 2 SAMPLE GAS PROBE In gas analysis, the sample point is a critical interface between the process and the analysis system. The GAS 222 series of probes have a robust modular design, come assembled-toorder, are easy to install and have low operational costs. Heated Probe with an In-Situ Filter and Weather Protection Shield Self- Regulating at Up to 120 C (T3) / 70 C (T4) with Low Temperature Alarm For Dust Concentrations of Up to 200 g/m³ ATEX Certification Product No. GAS 222.35 ATEX 2 1.4571 SS PTFE, Graphite,1.4404 SS + filter elements Voltage 115-230 V, 50/60 Hz Temperature Self-regulating; + 125 C (T3) / + 70 C (T4) Contact is open at operating temperature; Low Temperature Alarm closes at < 95 C (T3) resp. < 45 C (T4); Umax=30VDC, Imax= 100mA, CI/Li~0 Ambient Temperature - 20 to 80 C Suitable for II 3G EEx na L IIC T3; 3G c IIC T3; II 3G EEx na L IIC T4; 3G c IIC T4 18

DRM Technic -- Sample Probes -- Sample Probes RSS 24 / RSS 230 Blowback Controllers RSS 24 / RSS 230 BLOWBACK CONTROLLERS The Blowback Controllers RSS 24 and RSS 230 are meant for controlling the cleaning cycles of a probe filter. They are designed for use with probe types GAS 222.30, GAS 222.31 and ECO-01, but may also be used to control other external valves. Programmable Blowback / Sample Time Status Control Wall Mounted Product No. RSS 24 RSS 230 Power Supply 24 V DC ± 10% 85-265 V AC 50/60 Hz Fuse 5 A (slow) 1 A (slow) Relais Output Max. 10 A / 24 V DC / 75 W Max. 10 A / 230 V AC / 690 VA Ambient Temperature 0-55 o C 0-55 o C Blowback Time 0-60 s 0-60 s Sample Time 1 min - 99:59 h 1 min - 99:59 h Protection Class IP 65 IP 65 Weight Approx. 3 kg Approx. 3 kg Dimensions (H x W x D mm) 300 x 300 x 180 300 x 300 x 180 TIME FLOW DIAGRAM For more information, please feel free to contact our sales department 19

GAS 222 Sample Probe Accessories GAS 222 SAMPLE GAS PROBE ACCESSORIES We have a large range of Accessories for GAS 222 Sample Gas probes. See below for our Blowback Accessories, including Capacitive Vessels, Pneumatic Actuators, 3/2-way Solenoid Valves and Blowback Controllers. Overleaf are the details of our Sample Tubes, In-Situ Filters, Protection Sheilds and Extensions, all available in various materials, in various dimensions, and as heated and non-heated versions. 20

DRM Technic -- Sample Probes -- Accessories GAS 222 Sample Probe Accessories 21

DRM Technic Ltd 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB United Kingdom Tel: +44 (0)1782 638491 Email: sales@drmtechnic.com