Pond Oxygenator. Single / Twin / Four.

Similar documents
pond and garden LED feature light

PHOTECH AMPHIBIOUS PA35/PA320/PA520 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

Complete Cleaning System

UV Biological Pond Filter. Inlet /Outlet Size

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

INSTALLATION AND INSTRUCTION MANUAL IMPORTANT PLEASE READ:

Vorton 11/18/36/55 2YEAR. GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

SUBMERSIBLE DIRTY WATER PUMP

6000, 8000, & 15000

AQUARIUM HEATER RANGE AH-25 / AH-50 AH-100 / AH-200 AH-300

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

EASYCLEAR 3000 YEAR GUARANTEE

SUBMERSIBLE WATER PUMPS

WARNING: Ensure that the UV is switched off at the mains before you attempt to conduct any type of maintenance on the EazyPod Complete.

Hand Dryer Installation & User Manual

aquamanta the experts in aquatic technology

WARNING: Ensure that the unit is switched off at the mains before you attempt to conduct any type of maintenance on the evouv.

NON-SUBMERSIBLE WATER PUMP

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

submersible water pumps

WC2 & WC3 Installation & Maintenance Instructions

2 IN 1 JUICER AND BLENDER

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Sunbeam Tower Fan with Night Mode

SimplyClear Pressurized Filter Product Manual

Flomate Mains Boost Pump Installation & Maintenance Instructions

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

2.8KW ELECTRIC FAN HEATER

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

SHORT WAVE INFRARED PANEL DRYER

EFX 200/300/400. aquamanta. the experts in aquatic technology. 4year guarantee. Instruction Manual. >400 Litres

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

model No: ir20.v2 FUSE

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Tempest TP420/180 Electric Pressure Washer

s l it l on for Infrared Heaters

Radiant Heater. Instruction Manual QH-200 N13275

14 Bottle Wine Chiller with Digital Display CZ51186

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final 120v 60Hz. Copyright 2017 Page of 20

BLOW DRY & GO HAIR KIT

Contents. Warning: Installation... 2 Warning: Operation...2 Warning: Disposal...3

Piranha. Models: 800/1500/2500/3500/5000/8000/ Instruction Manual

CoCo LoCo BLOW & GO NUTS DRYER. LSHD24 Instruction Manual

HEAVY DUTY BRASS SHOWER PUMPS

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20

Air Pump Up to 800 gallons

Model No: Little Devil II (inc ss)

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

V80-H Multistage Pump Instruction Manual

OPERATION & MAINTENANCE INSTRUCTIONS

LINEAR AIR PUMPS INSTRUCTION MANUAL SERIES PRO TM

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

PTC Ceramic Heater. Instruction Manual THE SCIENCE BEHIND HEAT

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

1.8l Rice Cooker. Instruction Manual

Convection Panel Heater

Operating Instructions UniTech Perfect

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Aquience 1200/1500 R

GARDENA. F 3000 Art F 6000 Art F 9000 Art F Art. 7929

Sunbeam Remote Controlled Tower Fan

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX

INFRARED PARAFFIN/KEROSENE/ DIESEL HEATER 28/37kW 230V

INSTALLATION & USER INSTRUCTIONS

3KW ELECTRIC FAN HEATER

PERFORMANCE SLIMMING BELT

AllClear G2 Series Pressurized Filters Product Manual

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Pressurized Filter Up to 1250 gallons

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

51AKB / 51 AKC OWNER S MANUAL

FHA 1100 A1 Domestic Water Pump

air conditioner/dehumidifier 9000btu/hr

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

DEVIL CERAMIC SPACE HEATERS

30KW ELECTRIC FAN HEATER

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Manual for MC21A SETUP INSTRUCTIONS

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

Omelette Maker. Thank you for your purchase. We hope that you are satisfied with

Installation, Operation & Maintenance Instructions

APW PSI PRESSURE WASHER

Installation and Wiring Instructions

Transcription:

Pond Oxygenator Single / Twin / Four www.blagdonwatergardening.co.uk www.interpetcentral.com

Congratulations on buying a Blagdon Pond Oxygenator air pump. These air pumps have been specifically designed for water gardening applications, where sufficient aeration is an essential part of a successful pond. BENEFITS OF POND AERATION Fish and other pond life require oxygen-rich water in order to remain healthy. Filter bacteria, essential to the breakdown of highly toxic ammonia and nitrite, also require oxygen to flourish and keep the pond free form the build up of toxic waste. Use of a Blagdon Pond Oxygenator will increase the level of oxygen in the pond and reduce levels of carbon dioxide, thus aiding in preventing the pond from stagnating, by injecting air into the water. Additionally, by placing the air stones directly into the filter chambers, beneficial filter bacteria will be encouraged to grow. This will improve the efficiency of a pond filter, as well as improve fish health. Aeration in a pond is especially important during spells of warm weather, when water holds much less oxygen, and at night when plants stop producing oxygen and begin to use it. Fish seen gulping at the surface or swimming lethargically may be showing signs of a lack of oxygen. In winter, use of an air pump will keep an area of the pond ice-free, preventing the build up of toxic gases which can be fatal to fish and other aquatic life. Oxygenation, provided by the use of an air pump, is essential when treating fish diseases, as suffering fish require higher levels of oxygen, and many treatments deplete oxygen levels in the water. IMPORTANT: PLEASE ATTACH PROOF OF PURCHASE TO THIS MANUAL AND FILE IN A SAFE PLACE

CONTENTS Getting to know your Pond Oxygenator... 2 Parts descriptions / Spares codes / Exploded diagrams / Technical Specification...2-7 Installation... 8 Electrical installation... 8 Location... 9 Connecting air line and air stones... 9 Maintenance...10 Replacing the intake filter...10 Replacing the Outlet O-Ring...10 Replacing the diaphragm/flapper valve Pond Oxygenator Single, Twin & Four... 11 Troubleshooting...12 Troubleshooting and maximising performance...12 Faults/Problems Procedure...13 Consumer advice contact details...13 Returning faulty air pumps...13 Guarantee...13 1

GETTING TO KNOW YOUR POND OXYGENATOR Pond Oxygenator Single Parts Diagram: 1 2 14 3 5 4 9 6 7 8 10 11 12 13 2

GETTING TO KNOW YOUR POND OXYGENATOR Part No. Part Description Spare Code 1 Pond Oxygenator Single Lid N/A 2 Cable Gland N/A 3 Air Filter Pad Holder 1055940 4 Pond Oxygenator Single Lid O-ring 1055940 5 Air Filter Pad Holder O-ring 1055940 6 Pond Oxygenator Single Diaphragm & Flapper Valve 1055940 7 Pond Oxygenator Single Motor N/A 8 Pond Oxygenator Single Base N/A 9 Pond Oxygenator Outlet N/A 10 Pond Oxygenator Outlet O-ring 1055940 11 Pond Oxygenator Single Rubber Feet 1055940 12 Pond Oxygenator Single Base Screws 1055940 13 Pond Oxygenator Single Base Screw Caps 1055940 14 Air Filter Pad 1055940 Technical Specification Pond Oxygenator Model Single Twin Four Cable length 1.5m 1.5m 1.5m Power input 230v/50Hz 230v/50Hz 230v/50Hz Power Consumption (Watts) 3.2 4.2 8.3 Maximum flow (ltr/hr) 140 320 640 Maximum pumping depth in metres (ft/inches) 1.2 (3 11 ) 1.4 (4 7 ) 1.6 (5 2 ) CE Rating IPX4 IPX4 IPX4 3

GETTING TO KNOW YOUR POND OXYGENATOR Pond Oxygenator Twin Parts Diagram: 1 2 16 5 3 4 9 10 12 11 6 7 13 8 14 15 4

GETTING TO KNOW YOUR POND OXYGENATOR Part No. Part Description Spare Code 1 Pond Oxygenator Twin Lid N/A 2 Cable Gland N/A 3 Air Filter Pad Holder 1055941 4 Pond Oxygenator Twin Lid O-ring 1055941 5 Air Filter Pad Holder O-rings 1055941 6 Pond Oxygenator Twin Motor N/A 7 Pond Oxygenator Twin Base N/A 8 Pond Oxygenator Twin Rubber Feet 1055941 9 Pond Oxygenator Outlet Bridge & Screws N/A 10 Pond Oxygenator Twin Diaphragm and Valve Screw & Clamp N/A 11 Pond Oxygenator Twin Diaphragm and Flapper Valves 1055941 12 Pond Oxygenator Outlet N/A 13 Pond Oxygenator Outlet O-ring 1055941 14 Pond Oxygenator Twin Base Screws 1055941 15 Pond Oxygenator Twin Base Screw Caps 1055941 16 Air Filter Pads 1055941 5

GETTING TO KNOW YOUR POND OXYGENATOR Pond Oxygenator Four Parts Diagram: 1 2 16 5 3 4 10 9 12 11 6 7 13 8 14 15 6

GETTING TO KNOW YOUR POND OXYGENATOR Part No. Part Description Spare Code 1 Pond Oxygenator Four Lid N/A 2 Cable Gland N/A 3 Air Filter Pad Holder 1055942 4 Pond Oxygenator Four Lid O-ring 1055942 5 Air Filter Pad Holder O-rings 1055942 6 Pond Oxygenator Four Motor N/A 7 Pond Oxygenator Four Base N/A 8 Pond Oxygenator Four Rubber Feet 1055942 9 Pond Oxygenator Four Outlet Bridge & Screws N/A 10 Pond Oxygenator Four Diaphragm and Valve Screw & Clamp N/A 11 Pond Oxygenator Four Diaphragm and Flapper Valves 1055942 12 Pond Oxygenator Outlet N/A 13 Pond Oxygenator Outlet O-ring 1055942 14 Pond Oxygenator Four Base Screws 1055942 15 Pond Oxygenator Four Base Screw Caps 1055942 16 Air Filter Pads 1055942 7

INSTALLATION Electrical installation The power supply must meet the specifications on the product. The air pump is designed to be used with either a weather-proof cable connector or connected to the mains by means of a plug and socket. The cores in the supply cable are coloured in accordance with the following code: Brown = Live, Blue = Neutral, Green/Yellow = Earth The electrical cable is permanently connected inside the air pump body. If the supply cable is damaged the air pump must not be used. Do not use the supply cable to lift the air pump, as this may cause damage. WARNING - A Residual Current Device (RCD), also known as the Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the supply circuit. A means of disconnection from the supply having a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring. For permanent installations to the mains supply, it is necessary to conform to the regulations of the local electricity authority and this would include the use of a metal or plastic conduit to protect the cable. Attention has been drawn to the fact that the special rules may exist concerning the installation of your pond air pump (i.e. local building regulations). These air pumps must not be used in swimming pools, or areas where people are in contact with the water. Always disconnect and isolate the product from the mains electricity supply whilst the equipment is being installed, repaired, maintained or handled. Consult a qualified electrician if you are in any doubt about wiring this product to the mains supply. WARNING - The air pumps must not be submerged in the pond, they are for external installation only. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 8

INSTALLATION Location The Pond Oxygenator Pumps have been designed to be weather-proof, so they are able to be installed in most locations around the garden, or in a shed or garage, close to your chosen power supply. Ensure that the air pump is installed above the pond water level to avoid back siphoning of pond water into the air pump in the event of a mains power failure. Alternatively, if the air pump can only be installed below the pond level install Aqua Air Check Valves into each piece of air line. The air pump should be located on a firm surface which will not vibrate and act as a sounding board, a concrete floor or paving slab would be ideal. Position the air pump in a clean and dust free environment. Excessive dirt will block the air filters, reducing the air pumps performance and increase the speed of wear on replaceable parts. IMPORTANT - The air pump must be stood the correct way up with all four rubber feet touching the surface on which it is installed. This will ensure the maximum protection from adverse weather conditions. Water ingress will cause damage, and void the warranty. Connecting the air line and air stones Your Pond Oxygenator has been designed to run continuously and ideally unrestricted. This will maintain maximum performance and the best possible life span for all replaceable parts e.g. diaphragms and flapper valves. Ideally all outlets should have an air line and air stone connected, this will give your pond maximum aeration and ensure that damaging back pressure is kept to a minimum. Over time, air stones will become blocked leading to a reduction in air pump performance, therefore it is advised to replace the air stones every twelve months as a minimum, or more frequently depending on the cleanliness of the air pumps environment. Attach one end of the air line to the metal outlet on the Pond Oxygenator, attach the air stone to the other end of the air line. Then simply place the air stone into your pond or filter, and turn on the air pump. The air stones should be positioned to provide maximum aeration and circulation in the pond. (Note: for use in winter, the air stones should be placed no lower than 30cm from the bottom of the pond, this will ensure the warmer lower water regions remain undisturbed.) 9

MAINTENANCE IMPORTANT - The power supply to the air pump must be turned off before any maintenance is performed. Replacing the air intake filter (all sizes) 1 Slide out Air filter Pad Holder (part 3) from the rear section of the air pump. 2 Remove the felt pad inside the holder. 3 Insert new, clean felt pad. 4 Reinsert Air Filter Pad Holder in the rear section of the air pump. Replacing the outlet O-ring (all sizes) 1 Remove base screw rubber caps, and unscrew the base screws. 2 Lift off air pump lid. 3 Disconnect the air line in between diaphragm/flapper valve and the metal outlet. 4 Unscrew outlet lock-nut on the front of the air pump. 5 Push the outlet into the air pump for removal. 6 Remove the O-ring and replace with new. 7 Follow the above steps in reverse to reassemble. 10

MAINTENANCE Replacing the Diaphragm & Flapper Valve (Pond Oxygenator Single) Step Two Gently remove lid. Step Three Disconnect the air line between the diaphragm/ flapper valve and the metal outlet. Step Four Remove old diaphragm and flapper valve assembly - replace with new. Step One Remove base screw rubber caps, and unscrew the base screws. Step Five Follow steps 1, 2 and 3 in reverse order to reassemble. Replacing the Diaphragm & Flapper Valve (Pond Oxygenator Twin and Four) Step Two Gently remove lid. Step Three Disconnect the air line between the diaphragm/ flapper valve and the metal outlet. Step Five Unscrew the diaphragm and flapper valve clamp. Step Four Unscrew outlet bridge. Step Six Remove old diaphragm and flapper valve assembly - replace with new. Step One Remove rubber base screw caps and screws. Step Seven Follow steps 1 to 5 in reverse order to reassemble. 11

TROUBLESHOOTING Low air output/noisy operation Is the pump on a sounding board, such as a wooden shed floor, if so place the pump on a patio slab, which will reduce the effect, or relocate the pump to a more suitable location. Are the air lines and check valve free from obstruction, or is the air line kinked. Placing the air stones deeper in the water increases the back pressure, as it works harder to push the air, the noise generated by the air pump will increase. Check and replace any blocked air stones. Replace blocked or dirty air filter pads. Check diaphragm and flapper valve assembly for wear and tear replace as necessary. No air output/pump stopped Check the power supply is on. Check fuses and wiring. If the pump has been installed below the pond level, and without check valves, water may have siphoned back into the motor if this is the case, cease using the pump. The flapper valves and diaphragms may have failed replace as necessary. Air filter pads may be severely blocked replace as necessary. If none of the above resolves the fault, contact Interpet (Blagdon) Consumer Advice Department (see faults problem procedure inside back cover) 12

IMPORTANT FAULTS - PROBLEMS PROCEDURE Before returning your Blagdon air pump to your dealer or contacting our Consumer Advice Department, please carry out the following steps. These will solve most problems quickly and easily: 1. Ensure electrical procedure has been followed fully. Check fuses and any cable connectors or switchboxes. 2. Follow the maintenance steps from pages 10-11, follow the troubleshooting options from page 12 3. Return pump to point of purchase for inspection and advice (proof of purchase may be required) CONSUMER ADVICE CONTACT DETAILS: Interpet (Blagdon) Consumer Advice Department Vincent Lane, Dorking, Surrey, RH4 3YX E-mail: customercare@interpet.co.uk GUARANTEE This product is guaranteed against defects in material and workmanship for 3 years from the date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper use, negligence, lack of maintenance or accidental damage either to the pump, controller, or impeller. If the air pump fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge. Liability is limited to replacement of the faulty product only, no other costs will be reimbursed. This guarantee is not transferable and does not affect your statutory rights. This guarantee does not confer any rights other than those expressly set out above. Excludes all replaceable parts (diaphragm & flapper valves, air line, air stones, air filter pads and O-rings), which may become worn over time. If any parts need replacing, spares are available from your local retailer. ENVIRONMENT FRIENDLY DISPOSAL You can help to protect the environment, please remember to respect local regulations: hand in non-working electrical equipment to an appropriate waste disposal centre. 13

Established over 50 years ago, Blagdon are committed to producing a comprehensive range of high quality and easy to use water gardening equipment. We have an on-going programme of research and development that ensures excellent product performance and value for money for our customers. Our products are brought together with half a century of expertise and knowledge so you can be assured of a successful and creative water garden. INNOVATIVE DESIGN Interpet, Vincent Lane, Dorking, Surrey, RH4 3YX www.interpet.co.uk www.blagdonwatergardening.co.uk Leaflet Code: 31/8/17 MB