K-76 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

Similar documents
K-44 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

K-64 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

K-66 SERIES. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

K-86 SERIES. Exclusive Features: Standard Features: ENERGY STAR Qualified. Options: Models:

K-66 SERIES HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

K-86 SERIES HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

K-400 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

B-US 281 LPW HOT WATER SANITIZING FLIGHT-TYPE WAREWASHERS. Standard Features: Options:

DV The clean solution. Special Features: Standard Features: Options: HOT WATER SANITIZING DOOR-TYPE DISHWASHER

The clean solution HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS K-M54 SERIES. Special Features: Standard Features: Optional Features:

The clean solution HOT WATER SANITIZING MULTIPLE-TANK FLIGHT TYPE WAREWASHERS B-M74 SERIES. Special Features: Standard Features: Optional Features:

Standard Features. Performance/Capacities

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

FT1000S BASE FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT1000 FLIGHT-TYPE DISHWASHER

Model 80 DRHDPW 44 Single Tank with 36 Heavy Duty Prewash High Temperature Rack Conveyor Dishwashing Machine with

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

MODEL 86 PW MODEL 86 PW RACK CONVEYOR STANDARD FEATURES SPECIFIER STATEMENT. Project Item No. Quantity

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

CL64T INDUSTRIAL TOTE WASHER

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

C44A/C44AW DISHWASHER

Models. Options. Standard Features. LoH 2 O

FT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT

FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine FT SERIES FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER

CLPS86eN-BAS DISHWASHER

TECHNICAL MANUAL INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS FOR JACKSON MODELS: AJ-86CE AJ-86CGP AJ-86CS

FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine. FT SERIES FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER

Tall Hood Door-Type Variotronic High Temperature Sanitizing Utensil Washer (USA Version)

84 Series 84, 106 PW, 110 FFPW, 120 HDPW High-Temperature Rack Conveyor Dishwashing Machine

CL64eN-BAS DISHWASHER

Device and Duo Rinse r/hr. Warewashing

CL44eN-BAS DISHWASHER

FT900 FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

CLCS76eN-BAS DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

FT900BD FLIGHT-TYPE DISHWASHER

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

BASIL 6000 TUNNEL CAGE WASHER

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

CLCS76eN-EGR ENERGY RECOVERY DISHWASHER

EUCCW SERIES. EUCCW4, EUCCW6 and EUCCW8 Upright 29 Conveyor Dual Rinse Dishwashing Machine. Champion, an Ali Group Company

BASIL 6700 TUNNEL CAGE WASHER

STERO SCT-94SC/108SC/120SC CONVEYOR SERIES

CL64eN-EGR ENERGY RECOVERY/CL64eN-ADV DISHWASHER

Standard Features. Performance/Capacities. Operating Capacity Racks per hour. Hi-temp sanitization Chemical sanitization

CLPS66eN-EGR ENERGY RECOVERY/CLPS66eN-ADV DISHWASHER

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

K Tronic Series Installation and Start Up Checkout Procedure.

Door-Type Dual-Rack High Temperature Sanitizing Dishwasher (USA Version)

Warewashing. Warewashing. Single Tank Rack Type Dishwasher with Atmospheric Boiler

MEIKO K-Series Dishwashers

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ

GIRTON CABINET WASHER MODEL 794A

EUCC SERIES Upright 24" Conveyor Dual Rinse Dishwashing Machine

INSTALLATION/OPERATION & TECHNICAL MANUAL

green&clean multi-rinse Rack Type, Energy Saving Device, medium

Installation Manual. PRO Series Ventless Heat Recovery Rack Conveyor Dishwashers LISTED.

electric, 150r/h, R>L Warewashing Warewashing green&clean multi-rinse Rack Type, Energy Saving Device, large dryer, electric, 150r/h, R>L

LXGeR and LXGePR GLASSWASHER

Installation Manual. Manual P/N rev. B. PRO Series Standard Rack Conveyor Dishwashers LISTED. Models.

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.17A

Version 7 1/ LX

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

Detergent Dispenser. Warewashing. Warewashing. green&clean hood type Dishwasher, Manual with Filtering System & Detergent Dispenser

UW50 UTENSIL WASHER MODEL. FORM Rev. J (July 2013) (Electric machines only)

TECH WASH. ranges. TECH Main Features

CLe-series Dishwashers

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

FT SERIES FT1000e ELECTRIC

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

UW50 UTENSIL/PAN WASHER

electric, 150 r/h, left>right Dishwashing Dishwashing Multi-rinse Rack Type Dishwasher with Energy Saving Device, electric, 150 r/h, left>right

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

Version 7 1/ LXP

TURBOWASH TM... Pot and Pan Sink

! ATTENTION INSTALLER! THIS DISHWASHER IS EQUIPPED WITH A CONDENSATE REMOVAL VENT SHROUD WHICH WAS SHIPPED SEPARATELY IN ITS OWN PACKAGING.

TURBOWASH TM... Pot and Pan Sink

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

High Temperature Sanitizing Pot and Pan Washer (USA Version)

KLE-235D DOUBLE RACK IN-LINE CONFIGURATION KLE-175GTM SINGLE RACK THREE-DOOR CONFIGURATION KLE SERIES ULTRA WASH DISHMACHINE INSTRUCTION MANUAL

I N ST R UC T I ON C-LINE A, W, & AW DISHWASHERS MODEL R-L OPERATION L-R OPERATION C44A ML ML CRS66A ML ML-38948

VENTLESS DOOR-TYPE DISHWASHER

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

MODEL CMA-180UC PARTS MANUAL Rev 1.16

MODEL CMA-180UC PARTS MANUAL Rev 1.18

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

CLe-series Dishwashers

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2014

STERO SD3. Door-Type Dishwasher MODEL: ML

Repair Parts List DISHWASHER MODEL NUMBER DW871UQA. When requesting service or ordering parts, always provide the following information:

AM60E DISHWASHER INSTALLATION AND OPERATION INSTRUCTION

Owner s Manual. Keep with machine for reference PKD24A INSTALLATION & OPERATION. Rev

Transcription:

The clean solution pecial Features: ynchronized side-drive dual rack rail pawl-bar system ensures complete water coverage from every angle, even the bottom of the rack Large, insulated front are spring-loaded to open easily and TAY open, without latching Optimally-positioned wash arms in easily-removed assemblies. Arms and assemblies are stainless steel, eliminating high-wear gaskets and O-rings Concave, slotted nozzles minimize clogging. Nozzles are optimally-positioned at varying angles to maximize water coverage over all areas of the ware Powerful hp wash pump is 50% more powerful than the industry standard for outstanding cleaning Large separation between wash and rinse ( / 5mm upper, /559mm lower) avoids splashing of soiled water onto sanitized ware Front-sloping tanks for complete drainage and easier cleaning External, easily-operated lever drain system makes draining fast, safe and simple tandard Features: Capacity 9 racks per hour ater consumption 0.4 gallons (.6 liters) per rack 04-series stainless steel construction ouble-wall insulated construction on front, top and back to improve operator safety, conserve heating energy, and reduce noise and heat loss into the dishroom Large, easily-removed pan strainers with separate prewash scrap basket Fully automatic operation including auto-fill and autostart. Prewash, wash and final rinse are activated only when a rack is in place to conserve water and detergent Powerful hp (. k) wash pump. Pumps are verticallymounted to be self-draining and easily removed for servicing Electromechanical controls for reliability and easy operation. Low-voltage 4VAC control circuit for operator safety Easily accessible detergent and rinse aid injection ports for fast and easy chemical dispenser installation ingle-point electrical, water and drain s. Internal booster heater option adds an additional terminal block for simpler replacement of an existing external booster heater Low-level heater protection External vent fan control Pressure reduction valve ( with internal booster heater) Page K-76 eries Updated 7-4 K-76 ERIE HOT ATER ANITIZING INGLE-TANK RACK CONVEYOR IHAHER Options: Choice of two heights (standard 8 /457mm or tall hood 6 /660mm) Internal booster heater (steam or electric heat) External booster heater (steam or electric heat) limit switch (end stop or whisker switch versions) Vent cowl collars irect drive sideloader 90 powered loader or unloader Flanged feet rain water tempering kit hock arrestor Pressure reduction valve ( without internal booster heater) Models: K-76E: 8 vertical, electric heat K-76: 8 vertical, steam coil heat K-76ET: 6 vertical, electric heat K-76T: 6 vertical, steam coil heat This dishwasher is compliant with the Reduction of Lead in rinking ater Act (0) amendment to the afe rinking ater Act (A). MEIKO 49 Heil Quaker Blvd. LaVergne, TN 7086 (800) 55-MEIKO www.meiko.us sales@meiko.us

K-76 eries, left-to-right - electric heat w/o internal booster OR steam heat (all) (0mm) Control Vent cowl collar(s) (optional) 7" (78mm) T 8" (0mm) ' 6" (067mm) lip-in height ' 0" (864mm) 9-5/8" (44mm) 6-/" (65mm) 4-/ (mm) rain 8-/8 (05mm) 9-/ (4mm) ' -/ (95mm) 7-/" (89mm) 7/8" (mm) T -/" (90mm) 6 0-/ (096mm) 5" (7mm) irection of travel 7-/8" (485mm) 5-/" (40mm), " (80mm) " (5mm) -/8" (80mm) ' (405mm) ' 8-/" (5mm) ' -/ (74mm) ' -/" (95mm) ' 6-/ (768mm) 8" (0mm) ' 0" (559mm) 4' 6" (7mm) -to-table 6' (90mm) Vent cowl collar centerline 7 -/ (7mm) 7' 8" (7mm) Horizontal ' 8-/" (50mm) Variable imensions All dimensions from floor are +/- /" due to adjustable feet. ishtabling shown for dimensional purposes only. All dishtabling to be provided by others. tandard height Tall hood ' 6" (457mm) ' (660mm) open Vertical T 4 4' 9-7/8" (47mm) 5' 5-7/8" (67mm) 6' 7-7/8" (00mm) 7' -7/8" (45mm) 4 5' 9-/8" (756mm) 6' 5-/8" (45mm) 5 5' (66mm) 6' (89mm) ash section rain Page K-76 eries Updated 7-4 5 Utility Connection ymbols Utility ratings and specifications on Page 6. rain Ventilation ater team Condensate return T etergent MEIKO 49 Heil Quaker Blvd. LaVergne, TN 7086 (800) 55-MEIKO www.meiko.us sales@meiko.us

K-76 eries, right-to-left - electric heat w/o internal booster OR steam heat (all) Vent cowl collar(s) (optional) Control (0mm) 7" (78mm) T 8" (0mm) ' -/ (95mm) 9-/ (4mm) 4-/ (mm) rain 8-/8 (05mm) 6-/" (65mm) 9-5/8" (44mm) lip-in height ' 0" (864mm) ' 6" (067mm) ' 6-/ (768mm) -/8" (80mm) ' -/ (74mm) ' -/" (95mm) " (80mm) ' (405mm) ' 8-/" (5mm) " (5mm), -/8" (948mm) 5-/" (40mm) irection of travel 5" (7mm) 6 0-/ (096mm) -/" (90mm) T 7/8" (mm) 7-/" (89mm) ishtabling shown for dimensional purposes only. All dishtabling to be provided by others. Horizontal ' 8-/" (50mm) 4' 6" (7mm) -to-table 6' (90mm) Vent cowl collar centerline 7 -/ (7mm) 7' 8" (7mm) ' 0" (559mm) Variable imensions All dimensions from floor are +/- /" due to adjustable feet. 8" (0mm) tandard height Tall hood ' 6" (457mm) ' (660mm) open Vertical T 4 4' 9-7/8" (47mm) 5' 5-7/8" (67mm) 6' 7-7/8" (00mm) 7' -7/8" (45mm) 4 5' 9-/8" (756mm) 6' 5-/8" (45mm) 5 5' (66mm) 6' (89mm) ash section rain Page K-76 eries Updated 7-4 5 Utility Connection ymbols Utility ratings and specifications on Page 6. rain Ventilation ater team Condensate return T etergent MEIKO 49 Heil Quaker Blvd. LaVergne, TN 7086 (800) 55-MEIKO www.meiko.us sales@meiko.us

K-76 eries, left-to-right - electric heat with internal booster (0mm) Control Vent cowl collar(s) (optional) 7" (78mm) T 8" (0mm) ' 6" (067mm) lip-in height ' 0" (864mm) 4-/ (mm) rain 9-5/8" (44mm) 6-/" (65mm) 7-/" (89mm) 7/8" (mm) T -/" (90mm) 6 0-/ (096mm) (0mm) 5" (7mm) irection of travel -/8" (84mm) (0mm) (0mm) ' (405mm) ' 8-/" (5mm) ' -/ (74mm) ' -/" (95mm) ' 6-/ (768mm) 8" (0mm) ' 0" (559mm) 4' 6" (7mm) -to-table 6' (90mm) Vent cowl collar centerline 7 -/ (7mm) 7' 8" (7mm) Horizontal ' 8-/" (50mm) Variable imensions All dimensions from floor are +/- /" due to adjustable feet. ishtabling shown for dimensional purposes only. All dishtabling to be provided by others. tandard height ' 6" (457mm) Tall hood ' (660mm) open Vertical T 4 5' 9-/8" (756mm) 6' 5-/8" (45mm) 6' 7-7/8" (00mm) 7' -7/8" (45mm) 4 5' (66mm) 6' (89mm) 5 5' " (576mm) 5' 0" (778mm) rain Page 4 K-76 eries Updated 7-4 ater 5 Utility Connection ymbols Utility ratings and specifications on Page 6. rain Ventilation ater T etergent MEIKO 49 Heil Quaker Blvd. LaVergne, TN 7086 (800) 55-MEIKO www.meiko.us sales@meiko.us

K-76 eries, right-to-left - electric heat with internal booster Vent cowl collar(s) (optional) Control (0mm) 7" (78mm) T 8" (0mm) 4-/ (mm) rain lip-in height ' 0" (864mm) ' 6" (067mm) 6-/" (65mm) 9-5/8" (44mm) ' 6-/ (768mm) (0mm) ' -/ (74mm) ' -/" (95mm) (0mm) ' (405mm) ' 8-/" (5mm) -/8" (84mm) 6 0-/ (096mm) ' 0-/ (564mm) -/" (90mm) 5" (7mm) irection of travel T 7/8" (mm) 7-/" (89mm) ishtabling shown for dimensional purposes only. All dishtabling to be provided by others. Horizontal ' 8-/" (50mm) 4' 6" (7mm) -to-table 6' (90mm) Vent cowl collar centerline 7 -/ (7mm) 7' 8" (7mm) ' 0" (559mm) Variable imensions All dimensions from floor are +/- /" due to adjustable feet. 8" (0mm) tandard height ' 6" (457mm) Tall hood ' (660mm) open Vertical T 4 5' 9-/8" (756mm) 6' 5-/8" (45mm) 6' 7-7/8" (00mm) 7' -7/8" (45mm) 4 5' (66mm) 6' (89mm) 5 5' " (576mm) 5' 0" (778mm) rain Page 5 K-76 eries Updated 7-4 ater 5 Utility Connection ymbols Utility ratings and specifications on Page 6. rain Ventilation ater T etergent MEIKO 49 Heil Quaker Blvd. LaVergne, TN 7086 (800) 55-MEIKO www.meiko.us sales@meiko.us

K-76 eries Utility Connections T rain -5/6 (75mm) O vertical, gravity-fed drain outlet (HPE piping). Recommend placement directly above 4 floor drain. Additional piping to drain (if so required) to be supplied by customer. Connection is 9-5/8" (44mm) AFF. If using optional NPT adapter, is 8-/ (4mm) AFF. Refer to etail View: rain for suggested. ingle electrical ingle terminal block inside control box (4-wire with ground - no neutral). ual electrical s - with internal electric booster heater Two terminal blocks inside control box (4-wire with ground - no neutral). - Machine electrical supply - Booster heater electrical supply supply (or supplies) should be routed into control box through strain relief(s) on rear of control box. Incoming leads must be appropriately sized for electrical supply. Individual disconnect with lockout/tagout strongly (provided by customer). Connection for standard-height is 5 4 (66mm) AFF. Connection for tall hood is 6 (89mm) AFF. Refer to utility chart on Page 7 for electrical load information. Vent - with optional vent cowl collars Refer to etail View: Vent for suggested. The waste air must be corrosion-resistant and frost-free. In particular, provisions must be made to prevent air temperatures of F/0 C or colder from reaching the machine at any time. A provision for draining moisture from the waste air pipe is strongly. Load end - 50 CFM (55 m h) Unload end - 50 CFM (55 m h) Total - 00 CFM (50 m h) etergent Connection is 6 (067mm) AFF. Provided hole is end of pre-plumbed detergent conduit. Feed external detergent line through conduit to wash tank. Hot water - without internal booster heater /" NPT female pipe is 9-/" (4mm) AFF. Temperature 80 F (8 C) Pressure 5-5 PI (.0-.7 bars) Initial fill 50. U.. gals. (90.4 liters) Consumption 0.0 U.. gals per hour (86. liters) per hour Recommended hardness -6 grains/u.. gal. ater - with internal booster heater only For steam heat, /" NPT female pipe is 9-/" (4mm) AFF. For electric heat, /" NPT female pipe is 5' " (576mm) AFF for standard- 5' 0" (778mm) AFF with tall hood option. Temperature: Machines with 40 F booster: 40 F (60 C) Machines with 70 F booster: 0 F (4 C) Pressure 5-5 PI (.0-.7 bars) Initial fill 50. U.. gals. (90.4 liters) Consumption 0.0 U.. gals per hour (86. liters) per hour Recommended hardness -6 grains/u.. gal. team - steam-heated Pipe is ' -/ (95mm) AFF. Machines without internal steam booster heater: / male NPT Machines with internal steam booster heater: -/ male NPT 0-0 PI CONTANT steam pressure is REQUIRE. If pressure is above 0 PI, use of a regulator is REQUIRE (supplied by customer). The pipe does NOT reflect the steam line size from the boiler to the dishwasher. The necessary steam line sizing must be determined by the facility's steam engineer based on the pressure and volume requirements. Consumption: Refer to utility chart on Page 7 Condensate return - steam-heated / NPT male pipe is 8-/8" (05mm) AFF. Condensate line MUT be pressure-free. Vent Connection Machines equipped with optional vent cowl collars may be installed underneath a ventilation hood, or may use pant leg ventilation ducts (to be supplied by the customer). To determine the dimensions of the duct, first determine how they will be installed: uct sleeved outside collar Inside dimensions of duct: 4 x 6 (0 x 406mm). uct sleeved inside collar Outside dimensions of duct: -/4 x 5-/4 (95 x 400mm). The duct must not interfere with the adjustable baffle, as shown. Adjustable baffle uct sleeved outside collar () 4 x 6 (0x406mm) inside dimensions " (50mm) max. uct sleeved inside collar (if required) -/4 x 5-/4 (95x400mm) outside dimensions / (mm) max. rain Connection The machine is equipped with a -5/6" (75mm) O vertical, gravity-fed drain. If possible, the machine drain can simply be positioned directly above a floor drain. If a floor drain is not in the correct location, or if local codes require a trap, a " indirect drain line may be attached using the supplied " NPT male adapter. Choose a piping material that: Complies with any applicable local and national codes Is rated for use with water temperatures up to 80 F/8 C Is rated for - ph to accommodate detergents and rinse aid in the drain water 9-5/8 (44mm) 8-/ (4mm) Optional NPT adapter Recommended Tabling Construction top (864mm) AFF Check that the table lip overlaps BOTH the inner and outer s. Use silicone sealer between the table lip and the machine to prevent leakage. Ensure that the detergent supply tube can be routed to the injection port. A vertical tapered rear edge to the backsplash (without an angled top) is. turndown flange / (9mm) max. Inner Outside view Outer (with support lip) All dishtabling by others 0-/ (55mm) Inside view Inner Angled top on tapered section not Outer (with support lip) Page 6 K-76 eries Updated 7-4 MEIKO 49 Heil Quaker Blvd. LaVergne, TN 7086 (800) 55-MEIKO www.meiko.us sales@meiko.us

K-76 eries Technical pecifications Operating Capacities (NF Rated) Racks per hour... 9 ishes per hour... 5,975 Glasses per hour... 8,604 Conveyor pecifications Conveyor belt speed... 6.64 feet/min. (.0m/min.) Horizontal... 8-/ (50mm) Vertical (K-76E, K-76)... 6 (457mm) Vertical (K-76ET, K-76T)... (660mm) This machine may not pass through standard doorways without machine disassembly or doorway modification. Check all dimensions carefully prior to ordering, or contact MEIKO at sales@meiko.us for assistance. ater pecifications Minimum water temperatures: Prewash tank... No minimum - 0-40 F (4-60 C) typical ash tank... 60 F (7 C) Final rinse... 80 F (8 C) Minimum incoming water temperature: Machines without internal booster... 80 F (8 C) Machines with internal booster... 0 or 40 F (4 or 60 C) Initial fill... 50. U.. gals. (90.4 liters) Prewash tank capacity... 7. U.. gals. (65. liters) ash tank capacity.... U.. gals. (5. liters) Venting pecifications Load end... 50 CFM (55m /h) Unload end... 50 CFM (55m /h) Total... 00 CFM (50m /h) hipping Information K-76E, K-76: hipping weight... 877 lbs. (98kg) Crating (LxxH)... 08 x 46 x 75 (74 x 68 x 905mm) K-76ET, K-76T: hipping weight... 967 lbs. (49kg) Crating (LxxH)... 08 x 46 x 85 (74 x 68 x 59mm) ome options and accessories may affect shipping weight or dimensions. Contact MEIKO at sales@meiko.us for assistance. Incoming water line size... / NPT Recommended water hardness... -6 grains/u.. gal. Consumption at 00% capacity:... 0.0 U.. gals. (86. liters)/hr. 0.4 U.. gals. (.6 liters)/rack Final rinse flow pressure... 5-5 PI (.0-.7 bars) Flow rate....70 U.. gals.(6.44 liters)/min. rain line size... -5/6 (75mm) O, NPT adapter supplied Maximum drain flow rate... 5 gals. (56.8 liters) per minute pecifications Machine supply Peak Minimum Maximum current supply circuit breaker/ draw ampacity disconnect K-76E (standard electric tank heat) 08V/60 Hz/ Ph 54.4 A 70 A 70 A 0V/60 Hz/ Ph 49. A 70 A 70 A 460V/60 Hz/ Ph 4.6 A 5 A 5 A K-76ET (tall hood, electric tank heat) 08V/60 Hz/ Ph 66.7 A 90 A 90 A 0V/60 Hz/ Ph 58.0 A 80 A 80 A 460V/60 Hz/ Ph 8.4 A 40 A 40 A K-76, K-76T (standard height and tall hood, steam coil tank heat) 08V/60 Hz/ Ph.7 A 0 A 0 A 0V/60 Hz/ Ph.8 A 0 A 0 A 460V/60 Hz/ Ph 5.8 A 5 A 5 A Internal booster heater Rating, Rating, Peak Minimum Maximum supply machine machine current supply circuit breaker/ startup operation draw ampacity disconnect 40 F rise electric booster (40 F/60 C water supply temperature) 08V/60 Hz/ Ph 8.0 k 0.8 k 50.0 A 70 A 70 A 0V/60 Hz/ Ph 8.0 k 0.8 k 45.0 A 60 A 60 A 460V/60 Hz/ Ph 8.0 k 0.8 k.6 A 0 A 0 A 70 F rise electric booster (0 F/4 C water supply temperature) 08V/60 Hz/ Ph 8.8 k.6 k 79.9 A 00 A 00 A 0V/60 Hz/ Ph 8.8 k.6 k 7. A 00 A 00 A 460V/60 Hz/ Ph 8.8 k.6 k 6. A 50 A 50 A Electric tank heater ratings (K-76E, K-76ET) 08V/60Hz/Ph 0V/60Hz/Ph 460V/60Hz/Ph K-76E 5.0 k 4.6 k 5.0 k K-76ET 9.5 k 8.0 k 8.0 k Prewash pump motor... 0.75 hp (0.55 k) ash pump motor....0 hp (. k) Conveyor motor... 0.5 hp (0.09 k) team pecifications (K-76, K-76T) team line : Machines without internal steam booster heater... /4 NPT Machines with internal steam booster heater... -/4 NPT Condensate return... /4 NPT team pressure... 0-0 psi (0.7-.0 bars) team consumption: Tank heat... 60 lbs./hr. 40 F rise steam booster (40 F/60 C water supply temperature)... +50 lbs./hr. 70 F rise steam booster (0 F/4 C water supply temperature)... +00 lbs./hr. Page 7 K-76 eries Updated 7-4 External Booster Heater Recommendations (for without optional internal booster heater) Booster ratings are based on peak capacity of 0.0 U.. gals. (86. liters) per hour and a flow rate of.70 U.. gals. (6.44 liters) per minute. Recommended boosters are one size larger than required to help compensate for any local conditions that may prevent full performance. ater supply Required Recommended temperature temperature rise booster rating 0 F/4 C... 70 F/9 C... 4 k 40 F/60 C... 40 F/ C... k Note: All specifications are subject to change without notice based on MEIKO s dedicated product improvement program. MEIKO 49 Heil Quaker Blvd. LaVergne, TN 7086 (800) 55-MEIKO www.meiko.us sales@meiko.us

Equipment pecification: K-76 Rack Conveyor ishwasher- Item No. Item will be an NF and ETL-listed MEIKO K-76 single tank, rack conveyor dishwasher, consisting of a prewash zone with /4 hp (0.55 k) pump motor, a wash zone with hp (. k) pump motor, and a final rinse zone. Total length of the tank section (not including vent cowls) will be 6 4 (90mm). Unit will utilize a 80ºF/8 C minimum fresh water sanitizing rinse. Unit will have a capacity of 9 racks per hour at an NF-rated belt speed of 6.64 feet (.0m) per minute. Unit will consume an NF-rated 0.0 U.. gals./86. liters per hour (0.4 U.. gals./.6 liters per rack). characteristics: 08V/60 Hz/ Ph 0V/60 Hz/ Ph 460V/60 Hz/ Ph ash tank temperature will be maintained at a minimum of 60 F/7 C. Tank heating will be accomplished by: Thermostatically-controlled electric heating elements (K-76E, K-76ET) Thermostatically-controlled stainless steel steam coils (K-76, K-76T) irection of conveyor travel will be: Right-to-Left Left-to-Right Unit will have the following standard features: ouble-wall, insulated construction on top, front, and rear. Two upper prewash arms and one lower prewash arm. Five upper wash arms with 9 (48mm) wash area and five lower wash arms with 8 (457mm) wash area. ash arm spray pattern ensures effective coverage with varying angles and offset spray jets. lotted, concave wash nozzles and captivated end caps for easier cleaning. Minimum separation between wash and final rinse of (5mm) upper and (559mm) lower. ynchronized rack rail pawl bar system for smooth rack movement. ide drive system provides easy cleaning access and eliminates wash pattern obstruction. Front-sloping tanks for complete tank drainage, accessibility, and cleanability. Fully automatic operation including auto-fill and auto-start. eparate compartment actuator switches to ensure prewash, wash and final rinse are energized only when a rack is in place. External, easily operable, lever-operated drain system. Low level heater protection. Prewash and wash pump motors are self-draining, internal and vertically installed for easy access and serviceability. ash pump housing and impeller constructed of stainless steel. Electromechanical controls with a 4 VAC control circuit. ingle point electrical. Easily removable wash arm assemblies, prewash arms and final rinse arms. Large front access can be opened with one hand and remain open without latches, aiding machine accessibility and cleanability. Large, removable stainless pan strainers with separate prewash scrap basket. External vent fan control. ingle point drain. Pressure reduction valve ( with internal booster heater only). Unit will have the following optional features (check all that apply): Tall hood option to increase vertical from 6 (457mm) to (660mm) Internal booster heater (steam or electric per machine spec). ly-heated internal booster heater adds electrical terminal block to machine ( total). ized for a minimum 40 F ( C) rise and 40 F (60 C) min. incoming water temperature ized for a minimum 70 F (9 C) rise and 0 F (4 C) min. incoming water temperature External booster heater ized for a minimum 40 F ( C) rise and 40 F (60 C) min. incoming water temperature ized for a minimum 70 F (9 C) rise and 0 F (4 C) min. incoming water temperature team heated ly heated limit switch Inline (whisker switch) style End stop style Vent cowl collar(s) with adjustable damper 4 x 6 x 7 H (0x406x78mm) At both ends At load end only At unload end only 90 side loader (unhooded), long 90 side loader (hooded), long 90 power loader, 4-/4 long 90 power unloader, 4-/4 long Flanged, bolt-down feet rain water tempering kit hock arrestor Pressure reduction valve ( without internal booster heater only) Page 8 K-76 eries Updated 7-4 MEIKO 49 Heil Quaker Blvd. LaVergne, TN 7086 (800) 55-MEIKO www.meiko.us sales@meiko.us