IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Similar documents
TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Chapter 1 General... 5

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

2011 and 2014 National Electrical Code Changes Residential Only

ORDINANCE NO

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

Overview of Significant 2017 NEC Changes

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

IEC and NCCER Mapping for Year 1

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

TOM BURNS, PLANNING DIRECTOR

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

2017 NEC Presented by: Russ LeBlanc

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Photovoltaic (Solar) Array Installation Guide

Instructor: L. Keith Lofland

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

Revisions for the 2014 National Electrical Code

Electrical Tech Note 107

NEC {CODE CHANGES. OVERVIEW OF 2014 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

PANELBOARDS & BUILDING DISTRIBUTION

Revisions for the 2011 National Electrical Code - Part 4

TABLE 1-E (2017) Effective July 1, 2017

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

National Electrical Code

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

ll. Consistency Questions

Spring Test 6 due 04/26/2013

Revisions for the 2014 National Electrical Code Part 3

Town of Cicero Local Code Amendments

Residential Wiring (2014 NEC) (Homestudy)

Second Revision No. 321 NFPA [ Detail ] Submitter Information Verification. Committee Statement. Make the following changes to 210.

2014 National Electrical Code & NFPA 70E/Arc Flash

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

GPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators

SDEC 2017 Questions, Group 1

TABLE OF CONTENTS. Part I Administrative... 1

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

WIRING AND PROTECTION

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

2009 ELECTRICAL CODE REQUIREMENTS

NEC CODE QUESTIONS and ANSWERS Wisconsin Chapter IAEI Green Lake, Wisconsin May 16-18, 2012

Residential Wiring According to the 2011 NEC

Residential Wiring (2017 NEC) (Homestudy)

S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE

Residential Wiring According to 2011 NEC (Homestudy)

SERIES & NO. SMI SUBJECT: SAFE CONSIDERATIONS FOR AN APPLICATION OF SPECIAL ELECTRICAL SYSTEMS

BUILDER S PRE-INSPECTION CHECKLIST

SECTION AUTOMATIC TRANSFER SWITCHES

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

BUILDER S PRE-INSPECTION CHECKLIST

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

Revisions for the 2011 National Electrical Code - Part 1

NEC Code Changes. Overview of 2011 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

Requirements for Electrical Installations

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU ELECTRICAL PLAN REVIEW CHECKLIST

Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018.

Alberta Municipal Affairs

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

Bold items are particular to the City of Euless

Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)

NECA 169. Standard for Installing and Maintaining Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)

CHAPTER 14 ELECTRICAL CODE

Schedule of Approved Fees

Program, Code Panel Questions, & Survey/Comments

ENGINE GENERATORS AND ACCESSORIES

Municipal Code of Chicago TITLE 14E ELECTRICAL CODE

NEC CODE QUESTIONS. Western Section IAEI 103 rd Annual Meeting September 17-19, 2007

2016 Electrical Supplemental Plan Review List

ELECTRICAL BULLETIN

SECTION ISOLATED POWER SYSTEMS

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

SAN JOAQUIN COUNTY ELECTRICAL PLAN CHECK CORRECTION SHEET (209) FAX (209)

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

FIRE ALARM: BY OTHERS, IF REQUIRED.

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

2009 WESTERN SECTION CODE PANEL QUESTIONS

Electrical Safety Requirements

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

Electrical Design Guidelines Table of Contents

Understanding Your Options: AFCI Protection and the 2015 CE Code

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

City of Calabasas Building and Safety Division Fee Schedule

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

FIRE ALARM: BY OTHERS, IF REQUIRED.

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Page 1 of General

Important Upcoming Dates

Transcription:

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS June 17th, 2016 RE: City Council Adopts 2014 National Electrical Code with Pool Alarm Requirements On April 25th, 2016 the North Richland Hills City Council formally adopted the 2014 National Electrical Code (NEC) as published by the National Fire Protection Association. Please note that the city has amended the 2014 NEC utilizing the North Central Texas Council of Governments Recommended Regional Amendments, as well as a number of specific local amendments. All regional and local amendments can now be found under Chapter 98 of the North Richland Hills Code of Ordinances at www.nrhtx.com or directly at the following link: https://www.municode.com/library/tx/north_richland_hills/codes/building_and_land_use_regulati ons?nodeid=ptiicoor_ch98bubure The National Electrical Code is a copyrighted document and is not reproduced on the city's website; however, copies of the NEC can be found at the North Richland Hills Public Library or purchased from the International Code Council at www.iccsafe.org. General 2014 NEC Changes: 1) Throughout the 2014 NEC you will find many references where the voltage threshold has been increased from 600-volts to 1000-volts. 2) 110.26 (C) (3). Personnel Doors. Entrance/Egress door requirements are now required where equipment rated 800A is installed. (2011 was 1200A) 3) 110.26 (E) (2). Dedicated equipment space now required for outdoor electrical equipment. 4) 200.4 (B). Where more than one neutral conductor is in an enclosure with different circuit conductors, it shall be identified or grouped with the corresponding ungrounded circuit conductors. 5) 210.5 (C) (2). New requirements for identifying branch circuits supplied

from DC systems. 6) 210.8 (A) (7). GFCI protected receptacles are required within 6ft of all sinks in a dwelling unit. 7) 210.8 (A) (9). GFCI protected receptacles are required within 6ft of bathtub and shower stalls. 8) 210.8 (A) (10). GFCI protected receptacles are required in all laundry areas. 9) 210. 8 (D). GFCI protection is required for outlets that supply dishwashers in dwelling units. 10) 210.12 (A). Kitchen and laundry areas have been added to the list of rooms requiring AFCI protection. 11) 210.12 (B) exception. AFCI protection is not required for an extension of conductors not more than 6ft and does not include any additional outlets or devices. (Extension from a new panel to the old panel, using it as a junction box). 12) 210.12 (C). AFCI protection now required for Dormitory Units. 13) 210.13. Requirement for Ground Fault Protection of Equipment. Branch circuits 1OOOA or more and installed on solidly grounded wye systems of more than210.17. 150 volts to ground and not exceeding 600 volts phase-to-phase shall be provided with GFP of equipment in accordance with the provisions of 230.95. 14) 210.17. Outlet(s) installed for the purpose of charging electric vehicles shall be supplied by a separate branch circuit, and shall have no other outlets. 15) 210.52 (E) (1) & (2). This is a revised requirement for the outdoor receptacles required at the front and back of 1 & 2 family, and Multifamily dwelling units. The receptacles must be readily accessible from grade and not more than 6-1/2ft above grade level. (Previous language stated they must be accessible while standing at grand level). 16) 210.52 (G) (1). For attached and detached garages with electric power, the branch circuit supplying the garage receptacle(s) will not supply any outlets outside the garage. And at least one receptacle outlet shall be installed for each car space. 17) 210.64. New requirement for the installation of at least one 125-volt 15 or 20A rated receptacle outlet shall be installed within 50ft of the electrical service equipment. (This is for indoor and outdoor equipment, with an exception for 1 & 2 Family dwellings). 18) 215.12 (C) (1) (2). New requirement for the identification of Ungrounded Feeder Conductors. (1) Is for AC feeders supplied from more than one nominal voltage system. (2) Is for DC Feeder Conductors. 19) 230.82 (3). A meter disconnect shall be field marked on its exterior in a manner suitable for the environment as follows: METER DISCONNECT-NOT SERVICE EQUIPMENT. (This would be for a lever bypass inside a self-contained meter socket). 20) 240.87. Arc Energy Reduction. Only applicable to overcurrent devices rated 1200A or higher. (If you are dealing with an installation meeting this criteria, please familiarize yourself with the requirements of this section).

21) 334.40 (B). Non-metallic sheathed cable interconnector devices that are listed shall be permitted to be used without boxes for exposed cable wiring and for repair wiring in existing buildings where the cable is concealed. (An example is the TYCO tap/splice device for NM cable. It can now be used for the repair of existing cable and concealed.) 22) 406.3 (E). Controlled Receptacle Marking. Where non-interlocking 15 and 20A 125- volt receptacles are controlled by an automatic control device as part of an energy management or building automation system, these devices shall be marked with the symbol shown in figure 406.3 (E). 23) 406.9 (B) (1). All15 and 20A receptacles installed in wet locations shall have an inuse cover installed that is listed and identified as "Extra Duty". 24) 408.55 (C). New requirement for Back Wire Bending Space. This is for conductors entering the back of an enclosure opposite of a removable cover. The bending space must comply with tables 312.6 (A) & (B). 25) 422.51. GFCI protection is required for vending machines not utilizing a cord and plug connection. (Hardwired). 26) 424.66 (A) & (B). Working clearances are clearly defined here for duct heaters both below and in a space above the ceiling. 27) 450.10 (A). A terminal bar for all grounding and bonding conductors shall be installed inside the transformer enclosure, and shall not be mounted on or over any vented portion of the enclosure. 28) 450.11 (B). A transformer shall be permitted to be supplied at the marked secondary voltage, provided the installation is in accordance with the manufactures instructions. (Using a step down transformer as a step up transformer, it must be identified for "reverse wiring" by the manufacture). 29) 517.18 (B), 517.19(B), and 517.19 (C), Changes to these sections of code now require many more receptacles be installed at General Patient Bed locations, Critical Care Areas, and Operating rooms. (If performing this type of work, familiarize yourself with these new requirements). 30) 517.30 (B). The use of the term Emergency System has been removed, leaving simply the Essential Electrical System. This is comprised of 3 branches, life safety, critical, and equipment. 31) 517.30 (G). Overcurrent protective devices service the essential electrical system shall be coordinated for the period of time a faults duration extends beyond 0.1 sec. (with exceptions). This is to allow the downstream device closest to the overcurrent event to open before any upstream device can. 32) 600.6 (A) (1). The disconnect for a sign or outline lighting system shall be located where the feeder of branch circuit enters the sign enclosure or pole and shall disconnect all wiring where it enters the enclosure. 33) 680.21 (C). Outlets supplying pool pump motors connected to single-phase, 120 thru 240-volt branch circuits whether by receptacle or direct connection shall be provided with GFCI protection. (The limitation of 15 & 20A rated circuits has been removed). 34) 680.25 (A) (1) exception. A feeder between a remote panelboard and the service equipment shall be permitted to run in flexible metal conduit or an approved cable assembly provided it includes an "insulated" equipment grounding conductor. (The

term existing feeder has been removed. So a pool or hot tub being installed and fed from an existing sub panel will have to comply with the "insulated" equipment grounding conductor requirement). 35) 690.7 (F). New requirement for disconnecting means and overcurrent protection of energy storage device output conductors. (If performing this type of work, familiarize yourself with these new requirements). 36) 690.12. Rapid Shutdown of PV Systems on Buildings. This is a new requirement for the shutdown of the PV Source Circuits for a system mounted on a building. (If performing this type of work, familiarize yourself with these new requirements). 37) 690.47 (D). Additional Auxiliary Electrode for ground and pole mount arrays, as well as those on the building. (If performing this type of work, familiarize yourself with these new requirements). 38) 700.8. Surge Protective Devices are now required on all Switchboards and Panelboards that are part of an emergency system. 39) 700.19. Branch circuits service emergency lighting and power shall not be part of a multiwire branch circuit. 40) 700.28. Selective Coordination for overcurrent devices of Emergency Systems shall be selected by a professional engineer or other qualified person engaged primarily in the design, installation, or maintenance of electrical systems. 41) 702.7 (C). Power Inlet identification. Where a power inlet is used for the temporary connection to a portable generator, a warning sign shall be posted near the inlet to indicate the type of derived system that the system is capable of based on the wiring of the transfer equipment. (If performing this type of work, familiarize yourself with this new requirement and the language that needs to be used). 42) 728. NEW ARTICLE. Fire Resistive Cable Systems. 43) 750. NEW ARTICLE. Energy Management Systems. Swimming Pool & Spa Alarms (local amendment) The City Council also adopted a local amendment requiring door alarms on all exterior openings that provide access to a swimming pool, spa or hot tub. These amendments include the following: 1) Alarms must be on all doors with direct access to a pool, spa or hot tub area. 2) The alarm must sound within 7 seconds after the door is opened. 3) The alarm must capable of creating an audible notification that is at least 85 dba at the source and must be audible throughout the house. 4) The alarm must be installed at least 54 inches above the floor and be mounted to the door/wall so that it cannot be easily removed. 5) The alarm must have a manual means to temporarily deactivate the alarm for a single opening 6) In existing homes, the alarm can be battery powered or connected to the permanent electrical wiring system. New homes must have alarms that are permanently connected to the building s electrical wiring system. 7) In new homes constructed after the adoption of this ordinance, exit doors which may be capable of providing access to a future swimming pool, hot-tub or spa must be pre-wired

to the electrical system to accommodate the installation of a hardwired door alarm. This will require all new homes to have a junction box with an appropriately capped electrical power conductor to be installed at all rear exit doors (54 inches above the floor). 8) An additional Pre-Plaster/Safety Inspection has been added to all pool/spa construction projects. In order to pass this inspection, all door alarms, permanent fencing, and selfclosing gates must be installed and function properly. As always, we appreciate our contractors and look forward to working with everyone as we transition to the newly adopted code. Please note that houses currently approved and/or under construction as of the date of this notice will not be required to provide hardwiring for door alarms. Please feel free to call our office at 817.427.6300 if you have any questions. We re here to help. Most sincerely, David B. Pendley, AICP, CBO, LEED Green Associate Chief Building Official City of North Richland Hills North Richland Hills, Texas 76180