546 In-Line Submersible Patented ultra-stable Axial Ion Path reference cell. Sulfide, oxidizer, and poison proof! Chemically resistant CPVC, KYNAR, Polypropylene or PEEK body 300 psig insertion system 150 0 C max temperature 546 sensors and assembly parts are interchangeable with ABB TBI-Bailey Models TB556 and TBX556 ph and ORP The Platinum Bullet - ORP Solid Platinum billet non-glass electrode Flat tip eliminates breakage, reduces build up and simplifies cleaning. Longer lasting, minimal maintenance and customer convenience Patented ultra-stable Axial Ion Path reference cell. Sulfide, oxidizer, and poison proof! 547 Ball Valve Insertion Assembly The Ball Valve Insertion Assembly is our most popular installation system for the 547 cartridge. This allows maintenance and replacement of the sensor without shutting off the process line or draining the tank. Operationally rated to 100 psig. Insertion depths, materials and cleaning systems are customer selectable to insure the best measurement with the lowest total cost of ownership. Hardware interchangeable with ABB/TBI-Bailey 557 systems. The Pressure Monster Tested and certified to 2,500 psig! Chemically resistant CPVC, KYNAR, Polypropylene or Peek sensor cartridge Armored Hi-Pressure body made from SS316, Titanium or Hastelloy C Can be equipped to provide triple redundancy against toxic gas escape Patented ultra-stable Axial Ion Path reference cell. Sulfide, oxidizer, and poison proof! 1 551 Quick Change Patented Axial Ion Path reference cell. Sulfide, oxidizer, and poison proof! Chemically resistant CPVC, KYNAR or Polypropylene body 300 psig Quick-change hardware 150 0 C max temperature Ideal for sample lines and valved side-streams 551 sensors and assembly parts are interchangeable with ABB TBI-Bailey Models TB551 and TBX551 sensors Electrode & Tip Protection Options Dual Notched Tips Impact protection with easy cleaning Recessed Tips Maximum protection Mining and abrasives Flush Tips Pulp streams, and auto-cleaning systems
Transmitters Stratos Pro A2 & A4 The Universal Analyzer : Accepts Memosens, ISM, and digital sensors, as well as classic electrochemical ph/orp, 2- and 4- electrode, and inductive conductivity, and electrochemical oxygen sensors. The backlit display of the Stratos Pro changes between six different colors to clearly signal operating states, reducing the risk of operator error during analyzer maintenance. 2 wire loop powered or 4 wire mains powered versions HART, on all models ATEX Zone 1, FM/CSA Class 1, Div 1 / Div 2 option Stratos ECO 2405 Industrial performance at a commodity price! Industrial 4-wire transmitter for ph/orp, conductivity, and electrochemical oxygen. FM/CSA Class 1, Div 2 approval On-board limit controller 2 analog outputs for measurement variable and temperature Full diagnostic suite for analyzer and sensor NEMA 4X, PBT enclosure For pipe, panel, or rail mount Stratos e-2000 transmitters Protos 3400 The Protos 3400 measuring system is a modular hardware and software concept for liquid analysis, and offers flexible solutions precisely tailored to the measuring task. It is possible to easily measure several process variables simultaneously, such as ph/cond, ph/ph, Cond/Oxy etc. with the appropriate configuration. Similar to a PC, the device is fitted with 3 slots, and can be retrofitted or modified at any time. FM/CSA Class 1, Div 2 Portamess 911 Portable ph Analyzer Calimatic automatically recognizes the right buffer automatic calibration at the press of a button 8 buffer sets to choose from Simultaneous ph/mv and temperature display Automatic device test during power-on Sensoface electrode monitoring Temperature detection with automatic Pt 1000 / NTC 30 kohm recognition 2000 operating hours on just 3 AA batteries Battery indicator Auto switch-off EMC design Portamess 913 Portable ph Analyzer 2-wire loop powered or 4-wire mains powered FM/CSA IS Class 1, Div 1, and Div 2, groups A, B, C, D ATEX II 2 (1) G EEx ib [ia] IIC T6 Hart, Profibus, Fieldbus On-board PID controller NEMA 4X, PBT enclosure Wall, pipe, or rail mount Diagnostic suite for both transmitter and sensor Sensor auto-cleaning relay 3 year warranty! Same features as 911, plus Integrated real-time clock, with date stamp. 1-, 2-, and 3-point calibration. Manual memory storage. Automatic recording of measured values over longer periods. Serial interface. Convenient. Paraly SW 109 transfer software. Transfers measured values to a PC. 2
Oxygen - Gas and Dissolved Phase - 4401OXY IDEAL FOR: Boiler Feed Water Gas Concentration Breweries and Wineries Tank Purging Packaging Hazardous Area Approval FM/CSA Class 1, Div 2 Gas Phase range from.5 ppm to 100% v/v Dissolved Oxygen range from 1 ppb up to 45 ppm Optical Fluorescence Technology Excellent long-term stability and low maintenance Normal calibration quarterly to yearly More than 100,000 data points without drift No membranes or chemical consumables Serviceable sensor element lifetime up to 5 years Quick response - full reaction and stabilization to T90 in less than 90 seconds. Robust Stainless Steel NEMA 4X Enclosure options. Wide range of sensor installation options, including: 12 mm PG13.5 Ball-valve insertion 3/4 MNPT or Quick-change in-line Custom sensors available Signal independent of flow velocity Not affected by electrical interferences and magnetic fields Not affected by pressure changes Pressure Capability to 2,500 PSI 3
PDO 2 Optical Oxygen Sensor Sensor configurable for Electrochemical, 4-20mA, or RS485 output Hi-temp, Lo-loss cable VP-8 Quick disconnect Available in standard BAT body forms, including 546, 551, 547 Body material Polypropylene for best price/process match 546 model includes 3/4 Threaded In-line insertion depths 1 1/2 suitable for jet-cleaner Replaceable O-ring sealed lumiphore tip for easy maintenance Wide temperature capability: -10C to 30C Applications: Waste Water control and monitoring Mid to hi-level O2 monitoring and control Submerged, threaded in-line, Quick-change, and Ball valve-insertion models Dissolved Oxygen - PDO 2 Specifications: Single-Input Classic Configuration 100 psig in-line, 175 psig with Hi-pressure system 30 0 C (auto shut off at 80 0 C)- Polypropylene See chemical compatibility chart for body material choice See pressure / temperature charts for specific limitations Benefits: Numerous connection options Connect via wire or wireless to standard single-or multi input analyzer/controller, or direct to DCS Connect to customer s existing traditional membrane-style transmitter High pressure capability: -1 to 175 psi (impulses to 80BAR) BOS-2 lumiphore LLD 15ppb, 0.05% to 30% Oxygen/Air Saturation Not affected by H 2 S, CO 2, SO 2 Industrial Construction Tolerant of hydrocarbons, and other common industrial chemicals Adaptive sampling rate Longer lumiphore life, 1 to 3 years Options: Wired or wireless operation Jet cleaner Optional cable lengths via VP-8 connector Portable calibrator Wired or Wireless 1401 OXY Multi-Input Configuration Any combination of Wired or Wireless Replacement for Membrane Sensor Wired only Customer s Existing E-chem transmitter 1401DO Oxygen Analyzer 4-wire Industrial Oxygen Analyzer Power: 12-24 VDC, 20-53 VAC/DC, 110-240 VAC, 48 0 63HZ User-friendly menu structure User configurable On-board diagnostic suite Outputs: 2 X 0/4-20 ma or 0-10V 2 Relays - Control + Rinse Input: PDO 2 Sensor Binary for Key lock, Hold, or Alarm stop Display units: ppm, mg/liter, % saturation NEMA 4X enclosure Wall, pipe, or panel mount Economically priced single-input system Warranty: 1 year 4
Conductivity Sensors Boiler Feed 4-Electrode Conductivity Sensor 4-Electrode, ultra stable, coating tolerant design Insulator - Industrial Sapphire High Pressure - High Temperature 900 PSIG @ 500 o F (6.205 MPa @ 260 0 C) Hi-Performance 4-Electrode Conductivity Sensor Hi-performance 4-electrode contacting conductivity sensor Self-compensating for corrosion and scale build-up Ultra-stable measurement Installation options - threaded in-line, submersible, quick-change or ball-valve insertion style Uses standard Barben Analyzer installation systems Toroidal Conductivity Sensors BAT Toroidal Conductivity Sensors are low maintenance wide range conductivity measurement cells for inline, valve insertion and submersible applications. The toroidal design provides a wide range of chemical compatibilities and is highly resistant to scaling and other forms of performance loss due to chemical coating. High Pressure, High Temperature 2-Electrode Conductivity Sensor Hi-Temp, Hi-Pressure, perfect for boiler applications 205 0 C @ 250 PSIG Supplied standard with 8 integral lead and terminal strip 3/4 MNPT process connection In-Line and Submersible 2-Electrode Conductivity Sensors General purpose 2 electrode conductivity sensors Wide range of installation options Low-cost, economical configurations Wide range of cell constants to suit most conductivity ranges, and work with most transmitters 5
Suspended Solids/Turbidity Suspended Solids - S10, S20, S40 2 pairs of infrared light emitting diodes & photo-detectors pulsed in sequence Ratiometric signal processing compensates for changes due to aging and surface coating Effects of color, temperature and changes in background ambient light are virtually eliminated S10, S20, and S40 selectable to cover 0-25 g/l TSS MSSD53 microprocessor based transmitter provides both relay and/or analog outputs Auto-clean options Immersion Hygienic S10 S20 S40 Turbidity Sensor - T30 Ratiometric signal processing compensates for changes in the optical properties of the emitters and detectors due to ageing and surface coating Effects of color, temperature and changes in background ambient light are virtually eliminated 0-1,000 NTU (5 NTU LLD) The T30 sensor is designed for use with the Quadbeam MSSD53 microprocessor based transmitter MSSD53 Microprocessor based transmitter provides both relay and/or analog outputs Auto jet-spray feature standard Suspended Solids and Turbidity Transmitter - MSSD53 The MSSD53 transmitter is an advanced microprocessor based instrument for use with Barben Analyzer suspended solids & turbidity sensors. The instrument is supplied as standard with typical entry level defaults in the configuration program. Only the measurement range, probe signals, current output and alarm levels have to be entered for the unit to be commissioned. However, with a simple menu driven operator interface the full potential of the MSSD53 can be used to quickly set up any measurement strategy. Sludge Blanket Controller - MSSD33 The MSSD33 transmitter is an advanced microprocessor based suspended solids controller capable of accurately controlling and determining the sludge blanket level. 6
Accessories JB40 Integral Filtration System 10 micron filter excludes most coatings Submersion, In-Line or Flow-cell options Automatic Blow-back capability Replaceable filter element Uses 551 Quick-change sensor Polypropylene body & SS316 filter Hastelloy option Jet Spray Cleaners for ph Sensors Improves sensor life Reduces cleaning labor Reduces handling damage Improves responsiveness Eliminates dehydration Wetted Materials: SS 316, Kynar, CPVC, Titanium Use with B4 fluid distribution unit & Stratos 2402pH controller Fluid Distribution Unit The BAT B40/41 Fluid Distribution Unit allows you to operate your jet cleaner or mechanical scrubber with a minimum of assembly or maintenance time. Designed to connect between a local pressurized water or air line and your BAT auto-cleaning system, the B40/41 is a perfect companion to our Stratos or Protos Analyzers with on-board cleaning timers and control relays. Custom Sample Panels Hi-Purity Flow Cell SS 316 body provides EMF shielding Controls water impingement on electrode 1/4 inlet and outlet Holes for panel mounting Utilizes proven BAT 547 sensor cartridge Hi-Pressure Ball Valve Insertion System Insertion system for hi-pressure process lines or vessels Reduced insertion pressure in slurries and scaling processes Integral reaction housing with flush ports to facilitate cleaning and calibration Utilizes standard 546 sensors Double O-rings for retention process Anti-blowout flange for improved safety Sensor Scrubber Pot The BAT Sensor Pot allows you to submerge your sensor and scrubber assembly in a wet/dry sewer line, insuring that the sensor is kept hydrated while keeping the tip clean and free of biologic sludge or other buildup. Available in either PVC or Stainless, with 1 or 2 inlet and outlet. Sensor Extension Cables B39, B68 and VP8 Extension cables allow you to specify a single ph sensor for your entire plant even though you have differing distances between your probes and transmitters. ***COMING SOON*** Digital Sensors Expanded Quick Disconnect Cabling Contact Your Local Representative 7