VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Similar documents
VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Residential Heat & Energy Recovery

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

HEAT RECOVERY VENTILATOR

OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

ENERGY RECOVERY VENTILATOR

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

TECHNICAL SPECIFICATIONS

Ventilation Solutions IAQ Canada

Ventilation Solutions IAQ Canada

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Outside Air Requirements... SOLVED!

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Indoor Air Quality Product Brochure.

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Limited Lifetime core warranty. 5-year warranty on balance of unit.

10-year industry best core warranty. 5-year warranty on balance of unit.

Product Catalog Commercial Solutions US Edition

SECTION AIR DUCT ACCESSORIES

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Product Catalog Commercial Solutions US Edition

Indoor Air Quality Product Brochure.

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

IAQ VENTILATION SOLUTIONS

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

IAQ VENTILATION SOLUTIONS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

SAFETY AND INSTALLATION MANUAL MODEL 8100

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Put the V back in HVAC

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

Residential Balanced Ventilation Systems

LEED for Homes Points

VERTICAL FAN COIL UNITS

Chilled Water DOAS Fan Powered Terminal Units

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Heat or Energy Recovery Ventilation System

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

TR Series - The Ultimate ERV

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

INSTALLATION INSTRUCTION & OWNER S GUIDE

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

For performance and dimensional data, see back page.

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

BEST PRACTICE RECOMMENDATIONS

5 year fan housing and motor warranty

Ventilation Solutions Laundries. fantech

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

Indirect Gas-Fired Make-Up Air

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Single Package Vertical Air Conditioners. Vert-I-Pak

Caution: The fans must not be used in bath or shower enclosures.

Energy Recovery Ventilators

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD

62DA,DB,DC,DD,DE,DF07-38

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

1.1 This section applies to air handling units for HVAC Systems.

Heat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation

READ CAREFULLY AND SAVE R3

Direct Gas-Fired Make-Up Air

Tuning up ventilation systems

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Vert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING

COMMERCIAL VENTILATION

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

Light commercial models

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

VHR SERIES VHR 704. Installation Manual. Heat Recovery Ventilator INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Total Recovery for ALL Climates Models TR & TRC

SECTION AIR HANDLING UNIT

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

SECTION (15820) - AIR DUCT ACCESSORIES

Introduction to Indoor Air Quality

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

PA 500/1100V Ultra Quiet Ventilation Fan

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

A. Codes and Standards that are Standard at the University:

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

NU800, NU1200 & NU1600

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Transcription:

RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential Zone Register Terminals (ZRT - R) for continuous IAQ exhaust and on-demand boost exhaust. Each ZRT is installed in one bathroom in the house. These kits transfer sensible energy between stale exhaust air and fresh supply air, lowering the load on heating and cooling systems. The 24V ZRT-R's in the VentZone system are powered by the HRV, significantly reducing installation costs. Models H15-TRG and H19-TRG are ENERGY STAR Qualified (Canada). VentZone Zoned IAQ Kits with Heat Recovery Part Number System Number of Bathrooms Airflow @.2 in. w.g. Ventilator 6 ZRT-2-6-24R (24V) 1/2/3 CFM 4 ZRT-2-4-24R (24V) 1/2/3 CFM 4 ZRT-1-4-24R (24V) 2/4/6 Push Button Timer R39 321-24 VZ-IAQ-H15-P2-24V 2 142 CFM H15-TRG -- 2 -- 2 R39 322-24 VZ-IAQ-H15-P2.5-24V 2.5 142 CFM H15-TRG -- 2 1 3 R39 323-24 VZ-IAQ-H19-P2.5-24V 2.5 21 CFM H19-TRG 1 1 1 2 R39 324-24 VZ-IAQ-H19-P3-24V 3 21 CFM H19-TRG 1 2 -- 3 R39 325-24 VZ-IAQ-H19-P3.5-24V 3.5 21 CFM H19-TRG 1 2 1 4 R39 328-24 VZ-IAQ-H19-P4.5-24V 4.5 21 CFM H19-TRG 1 3 1 5 R39 329-24 VZ-IAQ-H19-P5-24V 5 21 CFM H19-TRG 1 4 -- 5 Accessories for VentZone Kits Part Number Description ZRT-1-6-24R Digital Multifunction Wall Control Shipping Weight R3955-24 ZRT and multi-function wall control 1 1 11lb HOW THE HRV WORKS HOW THE ZRT-2R WORKS DAMPER OPENING TO EXPOSE COLLAR AND ALLOW FULL EXHAUST EXHAUST TO OUTSIDE FRESH FROM OUTSIDE STALE FROM BATHROOMS VIA ZRT-2 TEMPERED SUPPLY TO LIVING SPACES MINIMUM CONSTANT FLOW REGULATOR IN DAMPER STALE TO HRV RECOVERY CORE STALE FROM BATHROOMS HRV ZRT-2R PROVIDING LOW-CONTINUOUS EXHAUST IN UNOCCUPIED LAUNDRY ROOM ZRT-1R OFF IN UNOCCUPIED HALF BATHROOM ZRT-2R PROVIDING ON-DEMAND EXHAUST IN OCCUPIED BATHROOM vz-iaq-hrv-kit_spec_517

STANDARD RESIDENTIAL H15-TRG Heat Recovery Ventilator For VentZone Systems CASING Material: Pre-painted 24-gauge galvanized steel Drain Connection: Ø 3/8 (Ø 1 mm) Duct Connections: Ø 5 (Ø 127 mm) Insulation: Molded EPS Width: 23-1/8 (587 mm) Height: 16-3/4 (425 mm) Depth: 12-3/8 (314 mm) Weight: 32 lbs (15 kg); Shipping Weight: 4 lbs (18 kg) Supply Damper: Motorized MOUNTING Suspended by chains with vibration-isolating springs Wall-mounting accessory available (P/N: 68575) RECOVERY CORE Material: Polypropylene DESCRIPTION Compact size, large performance the H15-TRG heat recovery ventilator produces approximately 142 CFM at.2 in.w.g (ESP) and recovers heat through its high-efficiency polypropylene core. The H15-TRG has been thoughtfully engineered for simple installation in apartments, condos, and small houses. The removable collars are top-mounted, which makes the unit both narrow and shallow enough to fit inside standard closets and other tight spaces. The H15-TRG has two exclusive features. EvacMAX provides on-demand boost for maximum ventilation. With FLEXControl, airflow circuits can be calibrated electronically, eliminating the need for resistance-inducing balancing dampers and improving overall efficiency. KEY FEATURES ENERGY STAR qualified (Canada) Damage-free packaging protects the unit in transit and makes it easy to remove it from the carton without damaging the collars Electronically and independently adjustable supply and exhaust blowers (FLEXControl) Gauge ports on the door for fast and reliable airflow readings Twist-in collars for easy flex-duct attachment Non-dust-loading backward-inclined impellers on totally enclosed motors Snap-out motor decks Easy access to core and filters for cleaning Extremely durable polypropylene core Standard MERV 6 filters Multiple low-voltage controller options Recirculating defrost collar snaps into pre-punched area of cabinet for ducting flexibility Compatible with third-party controls, such as smart thermostats. BLOWERS Quantity: 2 Type: Motorized impellers (backward-inclined) ELECTRICAL REQUIREMENTS 12 VAC, 6 Hz, 1.3 Amps, 156 W Cord Set: 48 (1219 mm) with ground CONTROLS Low voltage terminal strip (24VAC) for: 2/4/6 Minute Timer (P/N: 611228) Digital Multifunction Control (P/N: 611242) HVAC FAN INTERLOCK Onboard dry contact connection to allow direct interlock with a forced air system. Ensures proper air distribution during ventilation cycles when air exchanger is connected to forced air system ductwork. FROST CONTROL Automatic timed recirculation, fifth port Cycles controlled by a temperature sensor when the outdoor temperature drops below 23 F (-5 C) FILTERS Quantity: 2 Type: MERV 6 (P/N: 61249) WARRANTY Core Assembly: Limited lifetime warranty All Other Covered Components: Limited 5-year warranty APPROVALS Meets Standards: C22.2 no113 and UL 1812 ENERGY STAR qualified (Canada)

2 H15-TRG Dimensions TOP VIEW SIDE VIEW FRONT VIEW EXHAUST SUPPLY 2-1/4 (57 mm) Ø 5 Typ. (Ø 127 mm) 19 (483 mm) 16-3/4 (425 mm) RECIRCULATED OUTSIDE Performance RETURN ACCESS PANEL 12-3/8 (314 mm) 2-1/4 (57 mm) 23-1/8 (587 mm) 25-3/8 (645 mm) H15-TRG Ventilation Performance External Static Pressure in.w.g. (Pa).9 (225).8 (2).7 (175).6 (15).5 (125).4 (1).3 (75).2 (5).1 (25) () Recovery Performance Supply Temperature Net Airflow F C CFM L/s Power Consumed (W) Sensible Recovery Efficiency Apparent Sensible Effectiveness 32 52 25 44 67% 76% 32 64 3 46 65% 72% 32 99 47 11 56% 66% -13-25 68 32 73 63% 78% 6 (1) 8 (135) 1 (17) 12 (25) 14 (24) 16 (27) Airflow CFM (m 3 /h) Project: Location: Model #: Quantity: Architect: Engineer: Contractor: Comments: Submitted By: Date: vz-iaq-h15-trg_spec_517

STANDARD RESIDENTIAL H19-TRG Heat Recovery Ventilator For VentZone Systems CASING Material: Pre-painted 24-gauge galvanized steel Drain Connection: Ø 3/8 (Ø 1 mm) Duct Diameter: Ø 6 (Ø 152 mm) Insulation: 1 (25 mm) Fiberglass with FSK Width: 29-5/16 (745 mm) Height: 19-7/16 (494 mm) Depth: 15-11/16 (398 mm) Weight: 5 lbs (23 kg); Shipping Weight: 56 lbs (25 kg) Supply Damper: Motorized; Exhaust Damper: Gravity MOUNTING Suspended by chains with vibration-isolating springs RECOVERY CORE Material: Polypropylene DESCRIPTION Compact size, large performance the H19-TRG heat recovery ventilator produces approximately 199 CFM at.4 in.w.g (ESP) and recovers heat through its high-efficiency polypropylene core. The H19-TRG has been thoughtfully engineered for simple installation in small businesses and spacious houses. The H19-TRG has two exclusive features. EvacMAX provides on-demand boost for maximum ventilation. With FLEXControl, airflow circuits can be calibrated electronically, eliminating the need for resistance-inducing balancing dampers and improving overall efficiency. KEY FEATURES ENERGY STAR qualified (Canada) Electronically and independently adjustable supply and exhaust blowers (FLEXControl) Gauge ports on the door for fast and reliable airflow readings Removable top-mounted collars Twist-in collars for easy flex-duct attachment Non-dust-loading backward-inclined impellers on totally enclosed motors Easy access to core and filters for cleaning Extremely durable polypropylene core Optional high-efficiency filters Multiple low-voltage controller options Recirculating defrost collar snaps into pre-punched area of cabinet for ducting flexibility Compatible with third-party controls, such as smart thermostats. BLOWERS Quantity: 2 Type: Motorized impellers (backward-inclined) ELECTRICAL REQUIREMENTS 12 VAC, 6 Hz, 1.8 A, 216 W Cord Set: 48 (1219 mm) with ground CONTROLS Low voltage (24VAC) for 2/4/6 Minute Timer (P/N 611228) Digital Multifunction Control (P/N 611242) HVAC FAN INTERLOCK Onboard dry contact connection to allow direct interlock with a forced air system. Ensures proper air distribution during ventilation cycles when air exchanger is connected to forced air system ductwork. FROST CONTROL Automatic timed recirculation, fifth port Cycles controlled by a temperature sensor when outdoor temperature drops below 23 F (-5 C) FILTERS Quantity: 2 Type: Aluminum (P/N 612261) Optional: Carbon (P/N 612262), MERV 6 (P/N 61248) or highefficiency MERV 13 (P/N 612263) WARRANTY Core Assembly: Limited lifetime warranty All Other Covered Components: Limited 5-year warranty APPROVALS Meets Standards: C22.2 no113 and UL 1812 ENERGY STAR qualified (Canada)

2 H19-TRG Dimensions TOP VIEW FRONT VIEW SIDE VIEW 25-3/16 (64 mm) 18-15/16 (481 mm) 1-5/16 (262 mm) 4-1/8 (15 mm) ACCESS PANEL Ø 6 Typ. (Ø 152 mm) 4-1/8 (15 mm) 1-1/2 (267 mm) 19-7/16 (494 mm) 15-11/16 (398 mm) RECIRCULATED EXHAUST OUTSIDE Performance RETURN SUPPLY 29-5/16 (745 mm) 15-11/16 (398 mm) H19-TRG Ventilation Performance External Static Pressure in.w.g. (Pa) 1.1 (275) 1. (25).9 (225).8 (2).7 (175).6 (15).5 (125).4 (1).3 (75).2 (5).1 (25). () Energy Performance Supply Temperature Net Airflow F C CFM L/s Power Consumed (W) Sensible Recovery Efficiency Apparent Sensible Effectiveness 32 64 3 68 75% 84% 32 81 38 7 74% 81% 32 12 57 11 68% 76% -13-25 73 34 84 67% 86% Airflow CFM (m 3 /h) Project: Location: Model #: Quantity: Submitted By: Date: Architect: Engineer: Contractor: Comments: VZ-IAQ-H19-TRG_spec_517

FLOW & ZONE CONTROLS ZRT -R Zone Register Terminals - Residential GENERAL American Aldes patented* Zone Register Terminals (ZRT -R) are designed to introduce flexibility and on-demand control to central ventilation systems. Used in single family systems, the ZRT -R zonally regulates ventilation without the need for individual fans. Each ZRT is a combination grille, register box, control damper, and optional flow regulator(s). This unique combination provides up to four different control schemes without the need for expensive pneumatic, electronic, or DDC control systems. To ensure the proper calibration of the damper assembly, do not exceed 1. in. w.g. (25 Pa) of differential pressure across the damper door. ZRT -R Models ZRT-1R 16 o.c. Mounting Brackets (Included) ZRT-2R Integral CAR-II Minimum Flow Regulator and Damper (Not Shown) CAR-II Maximum Flow Regulator (Optional) By replacing static grilles in central exhaust systems, the ZRT-1R model provides on-off control for on-demand ventilation. This allows central fan downsizing and promotes energy savings by minimizing necessary fan horsepower and ventilation-induced heating and cooling loads on the building. The automatic operation of the CAR-II will prevent noise and excessive energy consumption caused by over-ventilation, as well as fluctuations in airflow rates as total system pressure varies. Damper Motor Cover CAR-II Maximum Flow Regulator (Optional) Damper Assembly The ZRT-2R model can be used for combination low-flow indoor air quality ventilation and on-demand high-flow spot ventilation using the same central fan system. This is achieved by integrating a minimum Constant Airflow Regulator (CAR-II) directly into the damper sub-assembly. With the damper completely closed, the factory-calibrated CAR-II will still allow steady, low-continuous ventilation during fan operation (consult the CAR-II specifications sheet for sizing and specifying information). When other ZRT -R are opened for on-demand control of spot ventilation, the closed ZRT-2R will maintain the specified lowcontinuous rate through the minimum CAR-II. By opening the ZRT-2Rs control damper, the low-flow CAR-II is removed from the air stream, allowing full maximum-boost ventilation. The ZRT -R can activate fans used in central exhaust ventilation systems. Through the use of an integral damper end-switch, the ZRT -R can trigger the remote fan to start. This provides the distinct advantage of allowing the fan to only ventilate specific spaces when called upon, without the need for separate fans ZRT -R Dimensions GG 1/2" 1/2" A SIDE 1" 1" C Exhaust/Return Air Grille (Included) Bead D E B oc BACK F 1" 1 SIZE A B C D E F G 4 8 8 4-1/2 3-7/8 2-1/2 3-1/2 7 6 1 1 5-1/2 5-7/8 3-1/2 4-1/2 8-1/2 *U.S. Pat. No. 7,766,734

2 ZRT -R in each space. This is especially important in residential bath exhaust applications using popular in-line and multi-port fans, where low noise and a single exterior vent penetration are desired. CONSTRUCTION The ZRT -R is constructed of a heavy-gauge galvanized steel housing for durability. Units are designed for installation in all ceiling types, with an overall height that allows location between floors using 1-inch or larger joist construction. The extended duct collar allows for simple attachment to rigid or flexible ducting. An integral steel mounting flange assembly encapsulates the ceiling opening and allows for simple attachment of American Aldes white all-aluminum flush-mount exhaust/return grilles. The damper assembly is provided with a long-life 24 VAC or 12 VAC actuator motor with spring return. A damper end-switch is available to allow signaling of a remote fan to activation. The gasketed tight-seal damper blade prevents air leakage and noise in the closed position. A solid one-piece damper that pivots on permanently lubricated bearings is used to support the blade assembly and to prevent deflection caused by motor torque and exposure to air velocity. The entire damper assembly can be installed or removed from below the register box without disconnecting the duct or removing the box from the ceiling. How the CAR-II Works Constant airflow is achieved by controlling the free area through the device. At minimum static pressure, the aero-wing is parallel to the air stream. As the static pressure increases, the aero-wing lifts, reducing the amount of free area through the regulator. At the same time, higher static pressure increases the air velocity resulting in CONSTANT FLOW. This occurs regardless of pressure differences in the range of.2 to.8 in. w.g. (5 to 2 Pa). The air velocity in the duct is in the range of 6 to 7 ft/min. (.3 to 3.5 m/s). CONTROL The ZRT -R can be activated using a variety of control options, on-off or timer switches, dehumidistats, occupancy sensors, or time-clock switches. Any on-off control device(s) will signal the damper to open fully, providing maximum ventilation control. Upon disconnecting the power, the ZRT -R integral spring will return the damper blade to its normally closed position. A Zone Terminal Fan Control Center (model ZTC) is available for use with up to (8) 24 VAC ZRT -R. Airflow control for both maximum and minimum flow rates is achieved using optional, integral, dynamic Constant Airflow Regulators (CAR-II). The CAR-II is an automatic modulating orifice that regulates airflows to constant levels in response to duct pressure. They require no additional power supply and are ideally suited for use in zonecontrolled systems where duct pressures can fluctuate in response to the opening and closing of dampers. MAINTENANCE The ZRT -R needs no maintenance when used in normal conditions. If the intended application includes air heavily loaded with grease or dust, a filtered grille is recommended. (6 EXAMPLE SHOWN) ZRT -R Airflow Regulator Performance Performance curves reflect airflow measurements taken at 68 F (2 C) at 1 atmosphere pressure. The CAR-II is capable of maintaining constant airflow within +/- 1% of scheduled flow rates (15% for units 15 CFM or less) within the operating range of.2 to.8 in. w.g. differential pressure. ZRT-2-4R Minimum Flow Control ZRT-2-6R Minimum Flow Control FLOW (CFM) PRESSURE DIFFERENCE (PASCALS) 7 25 5 75 1 125 15 175 2 6 5 4 3 2 1 3(5) 25(45) 2(3) 1(15).1.2.3.4.5.6.7.8 PRESSURE DIFFERENCE (IN. W.G.) FLOW (M3H) 1 8 6 4 2 3 25 2 15 1 5 FLOW (L/S) FLOW (CFM) 12 1 8 6 4 2 PRESSURE DIFFERENCE (PASCALS) 25 5 75 1 125 15 175 2 15(18) 2 9(15) 75(125) 6(1) 5(9) 45 (75) 4(7) 35(6) 25(45) 3(5) 2(3) 1(15).1.2.3.4.5.6.7.8 PRESSURE DIFFERENCE (IN. W.G.) FLOW (M3H) 16 12 8 4 6 5 4 3 2 1 FLOW (L/S) VZ-IAQ_ZRT-R_SPEC_517

RESIDENTIAL HRV/ERV Controls For Use with VentZone Systems These controls allow you to easily activate a variety of functions at the touch of a button. Each control fits inside any 2 x 4 service box. All controls include retaining screws and a white deco wall plate. Digital Multifunction Control (P/N 611242) Complete control over HRV/ERV: Dehumidistat mode ECO Mode (low-speed air exchange for 2 minutes of every hour) High Occupancy Mode (high-speed air exchange for 1, 2, or 4 hours when more people are in the space) Air exchanger maintenance indicator Relative humidity display 1 x 1 Liquid-crystal display Blue LED backlight (configurable as a nightlight) Compatible with 2/4/6 Minute Timer (P/N 611228) 24 VAC Fits inside 2 x 4 service box Includes retaining screws and white Decora -style faceplate 2/4/6 Minute Timer (P/N 611228) Activates the HRV/ERV to operate on high-speed mode for 2, 4, or 6 minutes Works with Digital Multifunction Control (P/N 611242) 24 VAC Fits inside 2 x 4 service box Includes retaining screws and white Decora -style faceplate 217 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice. American ALDES Ventilation Corporation 4521 19th Street Court East, Suite 14 Bradenton, FL 3423 USA 941.351.3441 8.255.7749 941.351.3442 (fax) info@americanaldes.com www.aldes.us VZ-IAQ- Residential Controls_spec_517