Installation Manual Local Ventilation System with Heat Recovery Type e² and e² short

Similar documents
Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

READ AND SAVE THESE INSTRUCTIONS

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

e Bath Fan with Light User s Guide

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

CONTENTS WIRING DIAGRAM

Operating and assembly instructions AH Freely Suspended Insular Hood

breeze easytm model # F100-1W

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

e Heater/Exhaust Fan/Light User s Guide

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

INSTALLATION INSTRUCTIONS

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Garage Ventilation Installation Instructions

Bathroom Exhaust Fan

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

,4X IMPORTANT SAFETY INSTRUCTIONS

Please Read and Save These Instructions Safety Information

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

Use, Care, and Installation Guide

Cooker Hood LA-72-CAN.

Bathroom Exhaust Fan/Fluorescent Light Combination

EN Instruction on mounting and use

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

VH60SS 60CM VISOR HOOD STAINLESS STEEL

GB User and maintenance manual

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Silvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user -

Bathroom Exhaust Fan/Fluorescent Light Combination

Installation Instructions Exhaust Fan With Light

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

Instructions Manual SHC520X - SHC700X

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

APPUZO RANGE HOOD INSTALLATION

Imperial. Read Before Starting Installation!

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

Installation Instructions Remote Blowers

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Operating and Installation Instructions

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

INSTALLATION INSTRUCTIONS

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Ventilator insert Silvento V... Installation directions - Please pass on to the user -

Centrif Duo & Centrif Duo Plus

Ceiling Fan Installation Instructions

Hamlet 60 & 80 Wall Hood

High Power Range Hood

Rigoletto 60,90 & 120 Built-In Cupboard Hood

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer


Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Island Extractor. Instructions & Installation LAM

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

User manual. Cooker hood CMH601SS CMH901SS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

90cm Chimney Extractor

Ceiling Fan Installation Instructions

SF180 Installation Instructions

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra SELV

Instructions Manual Manuel d Instructions Bedienungsanleitung Manual de instrucciones Εγχειρίδιο οδηγιών Руководство по эксплуатации

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Stainless Steel Chimney Extractor

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

User manual. Cooker hood GHC601 GHC901

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HUMIDITY SENSING BATH FAN

Easy installation in both new construction and retrofit

Instructions for use

CVS Model Inline Multi-Port Ventilators

60cm Canopy Extractor

Leonardo 90 Wall Hood

Falcon Undercupboard Rangehoods Installation Instructions & User Guide

Transcription:

Contents Installation Manual Local Ventilation System with Heat Recovery Type e² and e² short Page: About this manual, safety instructions 1 Technical Specifications, Disposal 1 Dimensional diagrams 2 Installation position 2 Shipping units 3 Assembly: Assembly pipe and outside grid 4 Assembly: Electric installation and electric connection 5 Assembly: Heat recovery unit and indoor blind 6 Assembly: Noise absorption set 7 Replacement ALD-R 160 / ALD-R 160 L for e² 7 Filter replacement, Cleaning 8 Additional replacement parts 8 About this manual Read this manual carefully and completely before assembly. Abide by the general safety instructions and the safety symbols with information in the text. Hand out this manual to the user (tenant, proprietors, property management etc.) after completing assembly. Symbols in this manual This symbol is a danger warning in connection with risk of injury This symbol is a danger warning in connection with risk of injury from electricity Safety instructions Beware! Any assembly work to the ventilation device may only be carried out after disconnecting all phases of supply voltage! The ventilation device is fitted with protective insulation according to Protection Class II, the protection connection is superfluous! Attention! The electric connection may only be made by authorised qualified personnel and according to the applicable version of VDE 0100! Attention! This device may not be operated by children and persons (filter replacement/ cleaning) who are not able to operate the device safely due to their psychic, sensory or mental abilities or their inexperience or lack of knowledge. Children should be supervised to ensure that they do not play with the device. Technical specifications Device voltage: 12 VDC SELV Type of protection: IP 22 Volume flow: 15m³/h; 30m³/h, 38m³/h Measuring sound pressure level 16,5 db; 19,5 db Sound level difference: 42 db Disposal Dispose of the packaging correctly sorted. If you want to dispose of the device, abide by the current rules and regulations. The applicable municipal office will provide information. 1

Dimensional diagrams (all dimensions in mm) Ventilation device 180 35 300-500 17 Dimensions in mm 200 300 e² short : Installation position Local ventilation devices with heat recovery of the type e² only function in pairs in bidirectional operation. A device operates 70 s (50s for e² short) in feed air operation, the other 70 s (50s for e² short) in exhaust air operation at the corresponding volume flow level as set. Then the air direction is changed. It is thus ensured that the total of the volume flow admitted is equal to the total of the exhausted volume flow. If a device pair operating in push-pull operation is installed in two different rooms of the flat and operated, a sufficiently dimensioned interconnection between the air movement must be provided by overflow air apertures. Recommended minimum spacing when installing a pair of devices in a wall: Recommended minimum spacing when installing a pair of devices across a corner: 1m 1,4m 1 m 1m Operating conditions Temperatur conditions: -15 C to +40 C Applicable indoor up to 65% relative humidity. During heating period are small condensate formation possible. If the limitation of use are overstepped, turn of the device and close the indoor blind. Ensure the gasper supply. 2

Shipping units Check the supplies for completeness and perfect conditions! Assembly pipe (min 2x, max 4x) Outside grid (min 2x, max 4x) Type 9/R 160 Order No.: 36 765 Type 1/WE 180 white Order No.: 39 852 Type 1/GE 180 light grey Order No.: 39 853 Type 1/RE 180 red-brown Order No.: 39 854 Pipe Protection lid For cleaning Heat exchanger unit Indoor blind (min 2x, max 4x) Heat exchanger unit Indoor blind e²: Assembly pipe, outdoor grid white, heat exchanger unit, indoor blind and installation instructions can be supplied as a complete set (Order No.: 39 846). Heat exchanger unit, indoor blind and installation instructions can be supplied as replacement set of ALD-R160 (type WTB 160, Order No.: 39 847). e² short: Assembly pipe, outdoor grid white, heat exchanger unit, indoor blind and installation instructions can be supplied as a complete set (Order No.: 39 962). Heat exchanger unit, indoor blind and installation instructions can be supplied as replacement set of ALD-R160 (type WTB 160 kurz, Order No.: 39 964). 3

Assembly Assembly pipes Make the wall openings for the assembly pipes (e.g. by coring, core bit Ø 162 mm). If necessary shorten the pipe to the required installation length (e²: min. 300 mm; e² short: min. 200mm). Take care that the pipe overlaps on both sides to cope with the plaster thicknesses (after plastering the pipe must close flush with the plaster). Insert the pipe and seal it all around (assembly glue Order No. 038 733). The product is not intended for connection to rigid metal conduit. Only use the provided plastic pipe. 1 Indoors Plaster protective lid Outdoors Apply plaster indoors and outdoors. When outdoor closure is plastered first replace the plaster protection lid outdoors by an outdoor closure piece. 2 Indoors Outdoors Remove the plaster protection lid outdoors. Assemble the outdoor grid using the integrated claw fasteners (tighten screws). ➂ Tighten claw fasteners with screws Further outdoor grids upon request! 4

Assembly electric installation and electric connection Safety instructions: Beware! Any assembly work to the ventilation device may only be carried out when all phases of supply voltage have been disconnected! Make sure that the supply voltage of all connection lines is dead! (separation from the power supply with a free space between contacts of at least 3 mm, e.g. all-phase disconnecting electr. protection). Each electric circuit of this ventilation system must be fitted with a residual current protection (e.g. RCD)! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b.) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. c.) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d.) Ducted fans must always be vented to the outdoors. e.) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit. The product s installation shall not conflict with any requirement in the National Electrical Code, ANSI/NFPA 70-1999. Additional installations and electrical components in this ventilation system are prohibited! 5

Assembly Assembly of the ventilation insert and the indoor room blind Remove plaster protection lid inside, insert heat exchanger unit into the assembly pipe, ensure there is a 22 mm spacing. Motor is on the inside. Using the loop on the inside of the heat exchanger unit the said unit may be pulled out for correction purposes. 6 Motor 22 mm Connect cables to plugs, insert pin and socket connectors into the recess of the heat exchanger casing. 7 Cable + - S1/S2 Motor cable red blue violet S1 - Device 1 S2 - Device 2 Pin-and-socket connector Insert indoor closure with filter casing, snap the indoor blind into place in open position! Ready! 8 open closed 7

Assembly noise absorption set Can be used as from a pipe length of 300 mm for e² and 230mm for e² short. Position noise absorption ring and noise absorption layer as depicted. The noise absorption layer can be shortened if necessary. Noise absorption ring noise absorption layer Replace ALD-R 160 / ALD-R 160 L by e² When carrying out a replacement the following parts of ALD-R 160 are not required any more: 1. covering frame 2. wind pressure protection 3. noise absorber elements + noise absorber end fitting The minimum length L min of the assembly pipe should be 300 mm. When keeping the outside closure with clamp spring (types 1/R 180) L min is 320 mm. The assembly of the e² is then carried out as described in this manual page 5 onward L min 1 2 3 Clamp spring 8

Filter replacement The contaminated filter will be signalize. For exact functionality please show the user manual for Universal Control 5/UNI or Touch Air Comfort TAC. In other respects do the filter replacement in the following way: Put the indoor closure off, extract the filter, insert new or cleaned filter (the filter cleaning could be made for example in a dishwasher), put the indoor closure on. The ventilation opening must not delivered or covered. filter Please draw up the filter replacement below: Filter replacement date Expected filter replacement Type of filter used Cleaning If necessary wipe the indoor blind and covering frame with a dry soft cloth. Filter replacement and cleaning may neither be carried out by children nor by persons who are not able to operate the device safely due to their psychic, sensory or mental abilities or their inexperience or lack of knowledge. Additional / replacement parts Indoor blind compl. 9/IBE Order No.: 39 851 Replacement filter G3, 9/FIB3R, pack of 3 Order No.: 37 214 Noise absorption set 9/SW Order No.: 39 850 Wind pressure fuse 9/WDSE (for assembly pipe from 370 mm length) Order No.: 39 860 Acustic insulated frame 9/IBS Order No.: 39 947 9