READ AND SAVE THESE INSTRUCTIONS. SE400E & SE800E Smoke Eliminator. TRION

Similar documents
Eliminator Series. SE400E and SE800E ELECTRONIC AIR PURIFICATION SYSTEM. Electrostatic Precipitators for Commercial Applications

Model CAC 500M Media Air Cleaner

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

T1001 Module T2002 Module T1300 T2600. Air Boss T-Series Custom Packaged Electronic Air Cleaner READ AND SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL. '»'"',' ','"* Self-contained Ceiling Mount Electronic Air Cleaner.

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

Operation And Maintenance Manual MODEL SSC-7 SEMI-FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

PACKAGED ELECTRONIC AIR CLEANER. Air Boss T-Series. Model T5200 INSTALLATION OPERATION SERVICE. Electrostatic Precipitator for Industrial Applications

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

AIR PURIFIER WITH GERMICIDAL UV LIGHT

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

WAILEA OWNER S MANUAL

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Electrostatic Air Cleaners for Commercial and Industrial Applications

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

HI Industrial Utility Heater HI Soleus Air International

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

e Heater/Exhaust Fan/Light User s Guide

Series 650 Read ALL INSTRUCTIONS carefully.

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Bath Fan with Light User s Guide

INSTALLATION AND OPERATIONS MANUAL

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

15-Year Limited Warranty

installation and operation manual for Hunter Ceiling Fans

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

installation and operation manual for Hunter Ceiling Fans

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

Lifetime Limited Warranty

Air Bear Accu-Fit TM. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

e Bath Fan with Light User s Guide

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

Academy Owner s Manual

CA3500, BA3500, CH3500 New Comfort

MALIBU STAR OWNER S MANUAL

Atria Ceiling Fan Owner s Manual

Owner s Guide and Installation Manual

Kenmore. Air Cleaning System. Compact Console Electronic Air Cleaner OWNERS MANUAL MODEL NO

Electric Space Heater

M-11 Series. Installation and Service Manual

Owner s Guide and Installation Manual

e Bath Fan with Light User s Guide

SUPRA 52. U.S. Patents: D450,830 INSTRUCTION MANUAL WARRANTY CERTIFICATE

Owner s Guide and Installation Manual

Oscillating Ceiling Fan

ELECTRONIC AIR CLEANERS

INSTALLATION, OPERATION AND SERVICE MANUAL MIGHTY ION MODEL MI SERIES

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

Lifetime Limited Warranty

LIMITED LIFETIME WARRANTY

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual

Series 375 Read ALL INSTRUCTIONS carefully.

INDUSTRIAL ELECTROSTATIC AIR CLEANER MODEL: SH-SSP-300

Larson by Hampton Bay

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

Owner s Manual STAINLESS CONICAL CHIMNEY HOOD CONTENTS

OVHM80 Max Air Purifier

TRION Air Purification systems

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT INSTRUCTIONS READ & SAVE

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Installation & Maintenance Instructions

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

IMPORTANT INSTRUCTIONS READ & SAVE

62" LED SPYRA. Product images may vary slightly from actual product. INSTRUCTION MANUAL

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

Lynwood 52 in Ceiling Fan Owner s Manual. Lynwood Ventilador de Techo de 1,32 m Manual del Propietario

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

30-YEAR LIMITED WARRANTY

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Parts and Instruction Manual CRV Clean Room Vacuum

ST. KITTS CEILING FAN

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Owner s Guide and Installation Manual

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INFO - LINE: After reading this manual, if you have any questions or comments on your Kenmore Air Cleaner, call

IMPORTANT INSTRUCTIONS READ & SAVE

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

User s Manual and Operating Instructions

Transcription:

READ AND SAVE THESE INSTRUCTIONS SE400E & SE800E Smoke Eliminator TRION www.trioniaq.com

Smoke Eliminator SE400E & SE800E Table of Contents Design Introduction... 2 Specifications... 2 The Filter System... 3 Installation Installation... 3 Diagrams... 5 Servicing and Maintenance Servicing / Maintenance... 6 Parts List... 7 Exploded Views... 8 Reference SE400E Wiring Diagram... 9 SE800E Wiring Diagram... 10 This manual provides information for installation, operation, and maintenance of your TRION SE400E & SE800E. Before installing and using the air purifier, carefully read these instructions to ensure maximum benefits from the unit and to avoid needless service costs that may result from improper installation and maintenance. WARNING! RISK OF ELECTRIC SHOCK These service instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. 1 www.trioniaq.com SE400E & SE800E Smoke Eliminator

Design Introduction The TRION Smoke Eliminator SE400E & SE800E are commercial air purifiers that have been specifically designed to remove airborne pollutants - including tobacco smoke, dust, pollen, and mold spores - in rooms and areas where people work or relax. They are designed to be mounted onto a solid ceiling, semirecessed into a suspended ceiling, or wall-mounted (SE400E only). Where appropriate, they can also draw in additional fresh air. Their features make them the ideal air purifier for installations into areas such as offices, conference rooms, restaurants, designated smoking areas, institutions and waiting rooms, or any other place where people gather. HOW THEY WORK The TRION SE400E & SE800E utilize the principle of Electrostatic Precipitation. Air is drawn into the intake, through the metal pre-filter, which traps lint and large dust particles. The remaining particles, some as small as 0.01 microns*, pass into a strong electrical field (ionizing section) where the particles receive an electric charge. The charged particles pass onto a series of equally spaced parallel plates (collector section). Each alternate plate is charged with the same polarity as the particles, which are repelled, while the interleaving plates are grounded, and therefore attract and collect the particles. * The diameter of a human hair is about 100 microns. Specifications Model SE400E SE800E Dimensions Depth: 9.5 Depth: 9.5 Width: 22.5 Width: 22.5 Length: 22.5 Length: 46.12 Installation Surface mounted, recessed into suspended ceiling, or wallmounted (SE400E only) Weight 42 lbs 80 lbs 48 lbs shipped 86 lbs shipped Input Power 120V, 1 Phase, 60 Hz Consumed Power 1.8 Amps 3.4 Amps 155 Watts 270 Watts Controls Hard-wired remote control with 3-speed selector switch with air dry (fan only) option Motor 1/20 HP (2) 1/20 HP 3-speed 3-speed Ball Bearing Ball Bearing Air Flow 200, 300 400, 600 400 CFM 800 CFM Sound Rating 38, 55, 62 dba 41, 58, 65 dba Safety Feature Interlock to cell access door Features Anti-arc circuitry Power to cell indicator Fresh air inlet, 6 diameter Dry (fan only) cycle SE400E & SE800E Smoke Eliminator www.trioniaq.com 2

The Filter System There are two filters in your air cleaner. The Pre-Filter: This is the mechanical filter that lies behind the inlet grill. It is designed to remove large particles and can be washed many times before replacement. The Electrostatic Filter: This is the deep aluminum assembly (Collector Cell) located immediately behind the pre-filter and is the heart of your air cleaner. It uses an electrostatic charge to remove particles so small that it would take a pile of many millions to cover a pinhead. When dirty, it can be washed and reused indefinitely. FILTER REMOVAL TRION SE400E: Turn the control switch off before removing cell. Press the two cell access latches, and the hinged door will swing down. Remove pre-filter by turning pre-filter clip 90 degrees (page 5, figure 2). While supporting the weight of the Collector Cell, loosen the filter retaining screw (figure 3). The filter retaining plate will now open, allowing the filter to be removed (figure 4). To reinstall the filter, simply reverse above procedure. TRION SE800E: The two hinged access doors are secured with retaining screws (figure 3). Release screws to allow the doors to swing down. Remove the Collector Cells as described above. INSTALLATION LOCATION The most effective location for the air purifier is the center of the area to be cleaned, because the dirty air is pulled into the center of the unit and discharged equally out the four sides. If more than one unit is required, space them evenly over the area to be cleaned. Installation Installation CAUTION ELECTRONIC AIR CLEANERS CANNOT BE USED IN AREAS WHERE COMBUSTIBLE GASES OR VAPORS ARE PRESENT. MECHANICAL The unit has been designed so that it can fit either surface mounted or into the ceiling, semi-recessed into a T-bar suspended ceiling, or wall-mounted (SE400E only). When installed with a T-bar suspended unit, NEVER support the unit from the T-Bars; the unit must be supported from the permanent ceiling. SUSPENDED CEILING INSTALLATION To hang the unit into a suspended ceiling, proceed as follows: 1. Unpack the unit, open filter access door, and remove pre-filter and cell (see filter removal in section 2). 2. Install 1/4-20 eyebolts into the mounting slots with large diameter washer and lock-nuts as shown in sketch A (page 4). 3. Install trim as shown in sketch A. 4. Select and remove a ceiling tile near the center of the area to be cleaned by the unit. 5. Attach a length of safety chain to each of the four eyebolts or fit threaded rod. Fasten securely. 6. Lift unit into place and support unit while securing to permanent ceiling, ceiling joists, etc. See sketch A. 7. Make electrical connections as detailed in next section. 8. Re-install cell and pre-filter. 9. Close access door, and unit is ready for operation. CAUTION IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE ADEQUATE MOUNTING COMPONENTS ARE USED. DO NOT ALLOW WEIGHT OF UNIT TO REST ON SUSPENDED CEILING SUPPORT RAILS. 3 www.trioniaq.com SE400E & SE800E Smoke Eliminator

SOLID CEILING MOUNTING To mount the unit to a solid ceiling, proceed as follows: 1. Unpack the unit, open filter access door, and remove pre-filter and cell (see filter removal in section 2). 2. Select a location near the center of the area to be cleaned. If you are fitting to wooden ceiling joists, locate the position of joists. 3. Using the template provided, drill four holes into the ceiling and fit four 5/16 lag screws in the joists. Hex-headed screws will give easier access for final tightening. Do not tighten fully home. 4. Lift the unit to where the large end of the keyhole slots in the top of the cabinet fit over the screw heads. Slide the unit so that the narrow ends of the mounting slots are located under the screw heads. Tighten the screws fully home. 5. Install the lockdown location screw as shown on template. 6. Make electrical connections as detailed in next section. 7. Re-install cell and pre-filter. 8. Close access door, and unit is ready for operation. ELECTRICAL WARNING: THIS APPLIANCE MUST BE ELECTRICALLY GROUNDED. NOTE: This unit is designed to be permanently connected to fixed wiring. Installation must comply with all applicable electrical codes. Hard Wired Remote Control Two sets of wiring are required to connect the unit. Main power to the unit is 120V, 60Hz, 1Ph, rated 5 Amp - Live, Neutral, and Ground. A 5-conductor 16 AWG cable is required from the unit to remote control. Run the 5-conductor cable and the main power connection through the cable entry knockouts (see page 5, figure 5) in the cabinet and connect to the input terminal block (figure 6) as shown in the wiring diagram on page 9 and 10. Mount the remote control in the desired position and connect the 5-conductor cable leads to the numbered terminals as shown in the wiring diagram. WALL-MOUNTED (SE400E ONLY) Filter removal will be simpler if the unit is positioned with the access door hinge in a vertical plane. Locate the wall studs and follow the mounting instructions for SOLID CEILING MOUNTING. SE400E & SE800E Smoke Eliminator www.trioniaq.com 4

Diagrams 5 www.trioniaq.com SE400E & SE800E Smoke Eliminator

Servicing and Maintenance Servicing / Maintenance Beyond an occasional wipe down with a damp cloth, the units need little in the way of maintenance. However, the units are designed to collect airborne dirt and, from time to time, will require routine servicing to remove the accumulation. The service interval varies considerably between applications, but typically will range from six weeks in a busy bar up to several months in a quiet office. During normal operation, the unit will make an occasional snapping noise. This is caused by large pieces of dirt accumulating on the electronic filter and is not dangerous. The TRION SE400E & SE800E units have anti-arcing circuitry to eliminate the nuisance of constant arcing. If, however, the arcing occurs every minute or two, it is an indication that the unit needs cleaning. When a service is due, proceed as follows: 1. Remove pre-filter and either vacuum clean it or wash as described below. 2. To clean the electronic filter, soak it in a hot (not boiling), strong non-caustic detergent cleaner. TRION can supply an excellent detergent - TriDex - obtainable through your Dealer. Alternatively, a dishwasher detergent does an excellent job. Soak the collector cell for several hours, then rinse with clean water. Do not physically try to rub the dirt off, since this can cause damage to the filter. 3. Allow the filter to dry thoroughly - preferably overnight - and replace into the unit or, alternatively, use force air dry setting on the unit. TRION has a policy of continuous product improvement and reserves the right to make chances in design and specification without notice. SE400E & SE800E Smoke Eliminator www.trioniaq.com 6

Parts List Item Part Number Description Qty/Unit SE400E 1 454027-001 Cabinet Assembly, SE400E 1 - Qty/Unit SE800E 2 454028-001 Cabinet Assembly, SE800E - 1 3 453844-001 Cell Access Cover 1-4 453844-003 Discharge Cover 1 2 5 453845-001 Cell Access Cover - 2 6 153853-001 Hinge Pin 2 4 7 453855-001 Grill 4 6 8 453856-001 Corner 4 4 9 453857-001 Grill Filter - 2 10 253863-001 Pre-filter 1 2 11 441730-103 Collector Cell 1 2 12 150685-001 Cell Retaining Clip 1 2 13 353842-001 Cell Latch 1 2 14 153854-001 Thumb Screw 1 2 15 244225-002 Bolt Retainer 1 6 16 345109-001 Cell Contact Assembly 1 2 17 453840-001 Cell Contact Support 1-18 453841-001 Cell Contact Support - 1 19 242404-002 Interlock Switch 2 4 20 147214-001 Insulator 2 4 21 350950-003 Power Supply Assembly 1 1 22 254167-003 Step-down Transformer 120V/24V 1-23 254167-004 Step-down Transformer 120V/24V - 1 24 453847-001 Motor Mounting Bracket 1 2 25 254026-002 Motor, 120V/60Hz 1 2 26 142153-001 Ground Contact 1 2 27 254101-001 Fan 1 2 28 453858-001 Inlet Ring 1 2 29 EST-1124 Terminal Block 1 1 30 253850-001 Terminal Block Cover 1 1 31 253851-001 Duct Cover Plate 1 2 32 153848-001 Interlock Switch Actuator 1-33 153849-001 Interlock Switch Actuator - 2 34 253852-001 Access Cover Latch 2-35 120035-210 Flat Head Screw - 4 36 234711-002 Retaining Nut - 4 37 354267-001 Remote Control Assembly 1 1 37a 250056-001 Rotary Switch 1 1 37b 242235-001 Switch Knob 1 1 7 www.trioniaq.com SE400E & SE800E Smoke Eliminator

Exploded Views SE400E & SE800E Smoke Eliminator www.trioniaq.com 8

B Installation, Operation, & Maintenance Manual Reference Wiring Diagram SE400E MOTOR CELL POWER SUPPLY POWER K (-) POWER A (+) YEL YEL 8-132 WH 7 6 5 4 3 2 1 N -142-141 LED -120-119 BL RD BR RD BL BK OR WH\BL WH\BN GY RD (LO) BL (MED) BK (HI) -111 WH GY GY WH BLK L BN BL B TB1 A 2NO 1NO 2C 1C BL BN -139-140 4 3 2 1 BR RD BL BK OR 6 5 4 3 2 1 INCOMING POWER N H E TEST CONTROL 9 www.trioniaq.com SE400E & SE800E Smoke Eliminator

Wiring Diagram SE800E Warranty All TRION air cleaners are warranted for component failure and workmanship for a period of three years after purchase. Do not return defective parts without prior permission from the factory. Contact your local TRION Distributor or TRION Customer Service Department at 800-884-0002 or fax 800-458-2379 to obtain material return authorizations and service information. SE400E & SE800E Smoke Eliminator www.trioniaq.com 10

TRION 101 McNeill Rd. Sanford, NC 27330 P: 800.884.0002 F: 800.458.2379 www.trioniaq.com customerservice@trioniaq.com Form No. 154385-002 Rev. 08/17 TRION 2017. All Rights Reserved.