NEC Code Changes. Overview of 2011 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

Similar documents
NEC {CODE CHANGES. OVERVIEW OF 2014 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

2011 and 2014 National Electrical Code Changes Residential Only

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

Instructor: L. Keith Lofland

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Revisions for the 2011 National Electrical Code - Part 1

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

Chapter 1 General... 5

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Electrical Tech Note 107

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Overview of Significant 2017 NEC Changes

Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018.

Second Revision No. 321 NFPA [ Detail ] Submitter Information Verification. Committee Statement. Make the following changes to 210.

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

2009 ELECTRICAL CODE REQUIREMENTS

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

Residential Wiring (2014 NEC) (Homestudy)

Residential Wiring According to 2011 NEC (Homestudy)

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

The most complete line of proven safety solutions.

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Residential Wiring According to the 2011 NEC

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

2017 NEC Presented by: Russ LeBlanc

TABLE 1-E (2017) Effective July 1, 2017

Spring Test 6 due 04/26/2013

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Residential Wiring (2017 NEC) (Homestudy)

SDEC 2017 Questions, Group 1

IEC and NCCER Mapping for Year 1

TOM BURNS, PLANNING DIRECTOR

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)

Units 2, 3, 4, 5, 6, 8, 9, 10, Electrical Wiring Residential Unit 2 (Unit 5 Fourth Edition)

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

NECA 169. Standard for Installing and Maintaining Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

ll. Consistency Questions

S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

2014 National Electrical Code & NFPA 70E/Arc Flash

WIRING AND PROTECTION

2010 Residential Ques. & Ans.

FIRE ALARM: BY OTHERS, IF REQUIRED.

Electrical Systems. Electrical Plans. Electrical Plans. Essential to ensure. National Electrical Code (NES) Consider electrical needs.

Revisions for the 2011 National Electrical Code - Part 4

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Municipal Code of Chicago TITLE 14E ELECTRICAL CODE

The Safer Living Collection

How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers

TECHNICAL ARTICLE. Inspecting Existing Dwelling Electrical Systems Using NFPA 73 by Skip Walker September 2009

Important Upcoming Dates

NEC CODE QUESTIONS and ANSWERS Wisconsin Chapter IAEI Green Lake, Wisconsin May 16-18, 2012

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

GE Industrial Solutions. Residential Electronic Circuit Interrupters

BUILDER S PRE-INSPECTION CHECKLIST

SECTION (16140) - WIRING DEVICES

FIRE ALARM: BY OTHERS, IF REQUIRED.

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

Understanding Your Options: AFCI Protection and the 2015 CE Code

Sensors and Timers P&S. designed to be better. A COMPLETE LINE FOR ENERGY SAVINGS AND CONVENIENCE.

2014 NEC for. Understanding the. AFCI protection AFCI code compliant safety. Eaton is a registered trademark.

AF/GF dual-purpose receptacles

Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians.

SW District 1. 1 Tony Tadysak Craig Mulder

MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS.

Revisions for the 2014 National Electrical Code

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put Into Perspective Electrocutions Can Be Prevented

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

Job No A. Submit the following equipment, materials and products, including all fittings and accessories:

Compatibility between Smoke Alarms and Arc-Fault Circuit Interrupters

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

EFCOG Best Practice #213

Student Guide. Wiring Edition. Compliments of. Georgia EMC East Exchange Place Tucker, GA (770)

Town of Cicero Local Code Amendments

SMALL HOMES COUNCIL - BUILDING RESEARCH COU CIL CIRCULAR SERIES INDEX G4 2 NUMBER ELECTRICAL WIRING

REPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE 2003 IAEI 75 th JUBILEE MEETING

NEC Study Guide CORRECT: C NEC (A)(1)

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

A HOMEOWNERS HANDBOOK

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

GFCI Products Buying Guide

National Electrical Code

Combination Type AFCI

District 1. 1 Tony Tadysak Craig Mulder

SECTION ISOLATED POWER SYSTEMS

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

BUILDER S PRE-INSPECTION CHECKLIST

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Intellectual Properties, Trademarks and Copyrights

Data Bulletin. Determining the Cause of AFCI Tripping Class 760

Transcription:

NEC Code Changes Overview of 2011 Related to Electrical Wiring Devices Cablofil Pass & Seymour Wiremold 104 P Street Belle Chasse, LA 70037 504-394-4132, fax 504-394-6922 www.pembaserv.com

Legrand/Pass & Seymour : your source for safety. Today s NEC regulations have new safety requirements. We have new ways to help you meet them. In 1971, Pass & Seymour introduced the first in-wall GFCI receptacle. Soon, our invention was preventing injuries and saving lives throughout North America. Today, you ll find P&S innovations and safety throughout a broad range of GFCI products products that offer new versatility, save installation time and solve problems. And products that continue a proud safety tradition that we began over 35 years ago. Choose P&S GFCI products for innovation and for all your groundfault protection needs. P&S Tamper-Resistant Receptacles - the full line to meet the NEC and enhance child safety. P&S Tamper-Resistant Receptacles protect children by letting plugs in, but keeping keys and other objects out with automatic shutters that block access. Safer and more convenient than plastic outlet caps, this proven safety solution provides a simple way to prevent painful injuries. And because tamper-resistant receptacles provide a real solution to a real problem, they re required in new residential construction by the National Electrical Code. You ll find everything you re looking for in the broad P&S Tamper- Resistant Receptacle line. Protection and traditional style in our 3232 TradeMaster Duplex Receptacle. Unique models like the P&S Nightlight/GFCI Combination. Fresh style in our P&S Signature choices. And much more! For more information, ask your Pass & Seymour distributor or visit /passandseymour.

Page i TABLE OF CONTENTS NEC SECTION DESCRIPTION PAGE 210.7 Disconnection of Multiple Branch Circuits and 1 Multiwire Branch Circuits 210.8 Readily Accessible GFCIs 2 210.8(A)(7) GFCI Protection of Receptacles Near Sinks in Dwellings 3 210.8(B)(5) Exception no. 2 to (5) GFCI Protection of Receptacles 4 Near Sinks in Health Care Facilities 210.8(B)(6) GFCI Protection of Indoor Wet Location Receptacles 5 210.8(B)(7) GFCI Protection of Receptacles in Locker Rooms 6 210.8(B)(8) GFCI Protection for Receptacles in Commercial Garages 7 210.12(A) Exception 1 & 2 Arc Fault Circuit Interrupter (AFCI) 8 Protection of Outlets in Dwellings 210.12(B) Arc Fault Circuit Interrupter (AFCI) Protection of 9 Outlets in Dwellings 210.52(A)(2)(1) Receptacle Spacing in Dwelling Units 10 210.52(A)(4) Countertop Receptacles 11 210.52(C)(4) Separate Countertop Spaces 12 210.52(C)(5) & 210.52(D) Receptacles in Kitchen and Bathroom Countertops 13 210.52(E)(3) Receptacles on Balconies, Decks and Porches 14 210.52(G) Receptacles in Basements, Garages and 15 Accessory Buildings 210.52(I) Receptacle Outlets in Dwelling Unit Foyers 16 285.25 Type 3 Surge-Protective Devices 17 (Transient Voltage Surge Suppressors) 310 Conductors for General Wiring 18 314.24 Outlet and Device Box Depth 19 314.27(A) Outlet Boxes for Luminaires 20 314.27(C) Outlet Boxes for Ceiling Fans 21 380.1 & 380.23 Multioutlet Assemblies 22 390.2 Underfloor Raceways 23 404.2(C) Switches Controlling Lighting Loads 24 404.9(B) Exceptions nos. 1, 2, & 3 Grounding of Snap Switches, 25 National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Inc., Quincy, MA 02269.

Page ii TABLE OF CONTENTS Dimmers and Similar Control Switches NEC SECTION DESCRIPTION PAGE 404.14(F) Snap Switch Rating for Plug and Cord Connected Loads 26 406.2 & 406.14 Tamper-Resistant Receptacles in Child Care Areas 27 406.4(D)(4) Arc Fault Circuit Interrupter Protection of 28 Replacement Receptacles 406.4(D)(5) Tamper-Resistant Replacement Receptacles 29 406.4(D)(6) Weather-Resistant Replacement Receptacles 30 406.6 Recessed Receptacle Faceplates 31 406.9(B)(1) Receptacles in Wet Locations 32 406.12 Tamper-Resistant Receptacles for Dwelling Units 33 406.13 Tamper-Resistant Receptacles in Guest Rooms 34 and Guest Suites 430.42(C), 430.81(B), Cord and Plug Connected Motors 35 430.109(F) 517.13(B)(1)(2) Grounding of Receptacles in Patient Care Areas of 36 Health Care Facilities 517.16 Isolated Ground Receptacles in Health Care Facilities 37 517.18(B) & 517.19(B)(2) Patient Bed Location Receptacles in Health Care Facilities 38 517.20(A) Receptacles in Wet Procedure Location Patient Care Areas 39 518.3(B) Temporary Wiring in Exhibition Halls 40 525.23 GFCI Protection for Carnivals, Circuses, Fairs 41 550.13(B) GFCI Protection of Receptacles in 42 Mobile/Manufactured Homes 550.13(F)(1) Receptacles Near Bathtubs and Shower Stalls in 43 Mobile/Manufactured Homes 550.25 AFCI Protection of Branch Circuits in 44 Mobile/Manufactured Homes 551.47(L) & 552.48 (K) Receptacle Faceplates in Recreational Vehicles 45 and Park Trailers 552.59(A) Park Trailer Outdoor Receptacles and Switches 46 590.4(D)(2) Receptacles in Temporary Installations 47 604.6(A)(5) Manufactured Wiring Systems 48 625 Electric Vehicle Charging System 49 680.21(C) GFCI Protection of Pool Pump Motors 50 680.32 Receptacles Near Storable Pools 51 SECTION 210.7 Disconnection of Multiple Branch Circuits and Multiwire Branch Circuits Ungrounded conductors must be simultaneously disconnected when two or more branch circuits supply devices on the same yoke. Section 210.7 is intended to reduce the likelihood of unexpected shock hazards for persons working on devices on the same yoke that are connected to multiple branch circuits. P&S Cat. #s: 5262, 3232, 8200HI Page 1 A means to simultaneously disconnect the ungrounded conductors must be provided at the point where the branch circuits originate when two or more branch circuits supply devices on the same yoke. Although the title in the 2011 NEC for Section 210.7 has changed to clearly state this section deals with Multiple Branch Circuits, the requirement remains the same. Section 210.4(B) addresses a similar hazard when a multiwire branch circuit supplies devices on the same yoke. The ungrounded conductors must also be simultaneously disconnected at the point where the branch circuit originates. An informational note was added to Section 404.8(C) as a reminder that Section 210.7 applies if multiple circuits are supplying a multipole switch.

Page 2 Page 3 SECTION 210.8 Readily Accessible GFCIs SECTION 210.8(A)(7) GFCI protection of Receptacles Near Sinks in Dwellings 6' GFCIs installed per 210.8 must be readily accessible. Ground Fault Circuit Interrupters that provide protection for receptacles as specified in Sections 210.8 (A), (B) and (C) must now be installed in a readily accessible location. GFCIs are marked test monthly and are provided with a test button that must be operated monthly to insure that the GFCI is functioning properly. Locating a GFCI where it is accessible will increase the likelihood that the GFCI will be tested by the user. A location that is Readily Accessible is defined in Article 100 of the NEC. 15A and 20A, 125V receptacles within 6 feet of a sink in a dwelling must be GFCI protected. GFCI protection must be provided for receptacles within 6 feet of all sinks in a dwelling. Previously, the requirement applied only to laundry, wet bar and utility sinks. This revision to the 2011 NEC parallels the requirement in Section 210.8(B)(5) to provide GFCI protection for receptacles within 6 feet of sinks in commercial and other non-dwelling installations. The code now insures that the same level of GFCI protection is provided for receptacles near sinks in all installations. Although Section 210.8(A)(7) states that the requirement applies to sinks other than those in kitchens, the intent is not to exempt countertop receptacles near kitchen sinks from having GFCI protection. Kitchen countertop receptacles are to required to have GFCI protection per Section 210.8(A)(6). As a result, receptacles that serve countertops located near kitchen sinks will have GFCI protection. The wording of Section 210.8(A)(7) is intended to make it clear that other receptacles, such as dishwasher and disposal receptacles that may be within 6 feet of a kitchen countertop sink, are not required to have GFCI protection. P&S Cat. #s: 1595, 2095v P&S Cat #s: 1595, 2095

Page 4 Page 5 SECTION 210.8(B)(5) Exception No.2 to (5) GFCI Protection of Receptacles Near Sinks in Health Care Facilities SECTION 210.8(B)(6) GFCI Protection of Indoor Wet Location Receptacles PZ1624 GFCI protection is required for 15A and 20A, 125V receptacles within 6 feet of sinks except in patient bed locations in general care or critical care areas. The exception to Section 210.8(B)(5) has been revised to make it clear that GFCI protection is not required for receptacles located near sinks in patient bed locations of general care or critical care areas. There is concern that receptacles located near hand washing sinks in these areas may be used for patient care life support, monitoring, and other portable patient care equipment that should not be plugged into a receptacle protected by a GFCI. Patient Bed Locations, Critical Care Areas and General Care Areas are defined in Article 517 of the code. 15A and 20A, 125V receptacles located in indoor wet locations are required to be GFCI protected. This new section has been added to the 2011 NEC to require GFCI protection for receptacles located in indoor wet locations in other than dwellings. An indoor wet location is an area such as a car wash or food processing facility. Receptacles located in indoor wet locations are exposed to the same potentially hazardous conditions that exist in outdoor wet locations. Section 210.8(B)(4) requires outdoor receptacles to be GFCI protected. This new requirement will insure that receptacles in indoor wet locations are provided with the same level of GFCI protection. This exception does not apply to other locations in Health Care Facilities. The exception is specific to General and Critical Care Areas. A receptacle located within 6 feet of a sink in other areas must be GFCI protected. P&S Cat #s: 1595HG, 2095HG P&S Cat #s: 1595, 2095

Page 6 Page 7 SECTION 210.8(B)(7) GFCI Protection of Receptacles in Locker Rooms SECTION 210.8(B)(8) GFCI Protection for Receptacles in Commercial Garages 15A and 20A, 125V receptacles located in a locker room with an associated shower facility must be GFCI protected. GFCI protection is now required for receptacles located in locker rooms that have an associated shower facility. A shower located near a locker room may create a hazardous condition. The damp and wet conditions in a locker room due to proximity to a shower, the use of electrical personal grooming equipment, such as a hair dryer, people with bare feet exposed to the damp tile floor of a locker room, all contribute to the increased risk of electrical shock. GFCI protected receptacles will provide a significantly increased level of safety in this type of environment. 15A and 20A, 125V receptacles in garages where electrical diagnostic equipment, electrical hand tools or portable lighting equipment is used must be GFCI protected. GFCI protection for receptacles in dwelling unit garages is required by Section 210.8(A)(2). Section 511.12 requires GFCI protection for receptacles in commercial service and repair garages where volatile flammable liquids or gases are used for vehicle fuel or power. This new Section, 210.8(B)(8), ensures that the same level of GFCI protection for receptacles will be provided in all garages, service bays and similar areas where electrical diagnostic equipment, electrical hand tools and portable lighting equipment are used. An example of a garage or service area not previously covered is a service facility for plug-in electric hybrid vehicles. P&S Cat #s: 1595, 2095 P&S Cat #s: 1595, 2095

Page 8 Page 9 SECTION 210.12(A) Exception 1&2 Arc-Fault Circuit Interrupter (AFCI) Protection of Outlets in Dwellings SECTION 210.12(B) Arc-Fault Circuit Interrupter (AFCI) Protection of Outlets in Dwellings A Receptacle Type AFCI may provide protection of the branch circuit. In the 2008 NEC the definition for an AFCI was in section 210.12(A). The definition has been relocated to Article 100 in the 2011 NEC. As a result of moving the AFCI definition to article 100, the requirements for AFCI protection that were stated in Section 210.12(B) in the 2008 NEC have been moved to section 210.12(A). Section 210.12(A) in the 2011 NEC requires AFCI protection for 120 volt, 15 and 20 amp branch circuits supplying outlets in family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms or areas. The exceptions to 210.12(A) permit a receptacle type Outlet Branch Circuit AFCI to provide the required protection when located at the first outlet of the branch circuit under the following conditions: Exception No. 1 The branch circuit conductors from the origin of the branch circuit to the first outlet are installed in RMC, IMC, EMT, MC cable or steel armored AC cable. Metal outlet and junction boxes must also be used between the origin of the branch circuit and the first outlet. Exception No. 2 The branch circuit conductors from the branch circuit overcurrent device to the first outlet are installed in listed metal or nonmetallic conduit or tubing encased in at least 2 inches of concrete. A Circuit Breaker or Receptacle Type AFCI must provide protection of branch circuit extensions and modifications. Section 210.12(A) in the 2011 NEC requires AFCI protection for 120 volt, 15 and 20 amp branch circuits supplying outlets in family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms or areas. A new section, 210.12(B), has been added to require AFCI protection for branch circuit modifications and extensions of the circuits specified in Section 210.12(A). The AFCI protection for the modified or extended circuits may be a listed Combination AFCI at the origin of the branch circuit or a listed Outlet Branch Circuit AFCI located at the first receptacle outlet of the circuit. The Combination AFCI located at the origin of the branch circuit is typically a circuit breaker AFCI. The Outlet Branch Circuit AFCI located at the first receptacle outlet will be a receptacle type AFCI. Either device may be used to meet the requirements of 210.12(B).

Page 10 Page 11 SECTION 210.52(A)(2)(1) Receptacle Spacing in Dwelling Units SECTION 210.52(A)(4) Countertop Receptacles Fixed cabinets are not included in determining the unbroken wall space for receptacle spacing. Section 210.52(A) provides the spacing requirements for the installation of receptacles in dwellings. When measured horizontally along the floor line of a wall space no point may be more than 6 feet from a receptacle. Section 210.52(A)(2)(1) defines a wall space as any space that is at least 2 feet wide and is uninterrupted along the floor line by an opening. In addition to openings, this section has been revised to include fixed cabinets. This insures that fixed cabinets, such as kitchen cabinets, are taken into account and are not included when determining the unbroken width of a wall space. Receptacles serving countertops are not considered as meeting the general provisions for receptacle spacing. A new section, 210.52(A)(4), has been added to make it clear that the countertop receptacles installed to comply with Section 210.52(C) may not be considered as the receptacles that meet the general provision installation requirements for receptacles in Section 210.52(A). The countertop receptacles are intended to serve the appliances that are used on a countertop space. P&S Cat #s: 885, 3232, 885TR, 3232TR P&S Cat #s: 885, 3232, 885TR, 3232TR

Page 12 Page 13 SECTION 210.52(C)(4) Separate Countertop Spaces SECTION 210.52(C)(5) and 210.52(D) Receptacles in Kitchen and Bathroom Countertops Receptacles are required in separate countertop spaces. The conditions describing when a countertop space is divided into separate countertop spaces by a counter-mounted cooking unit, range or sink have been moved from the general Section 210.52(C) to subsection 210.52(C)(4). Although the requirement has not changed, it was recognized that Section 210.52(C)(4) is the section that deals with separate countertop spaces. Listed receptacle assemblies may be installed in kitchen and bathroom countertops. Section 406.4(E) prohibits the installation of receptacles in a face up position in countertops. However, sections 210.52(C)(5) and 210.52(D) have been revised to permit listed receptacle outlet assemblies to be installed in kitchen and bathroom countertops. This change has been made to allow the installation of receptacle assemblies in the top surface of a countertop. The receptacle assemblies must be listed to insure that they have been evaluated to function properly when exposed to conditions likely to be encountered in countertop installations, such as liquid spills and splashing. A typical receptacle assembly for this application is a pop up type of receptacle having a cover that is flush with the countertop when not in use and pops up when operated to reveal the receptacle face. P&S Cat #s: 1595, 2095 Wiremold Cat. #s: KP2345, KP9999

Page 14 Page 15 SECTION 210.52(E)(3) Receptacles on Balconies, Decks and Porches SECTION 210.52(G) Receptacles in Basements, Garages and Accessory Buildings The receptacle must be located within the perimeter of the balcony, deck or porch. At least one 125 volt, 15 or 20 amp outdoor receptacle must be provided to serve a balcony, deck or porch of a dwelling. The receptacle must be located within the perimeter of the balcony, deck or porch. This requirement is intended to avoid the use of extension cords routed from an inside receptacle through windows or doorways to supply holiday lighting and other electrically operated products used outdoors. The 2008 NEC had an exception stating that for areas less than 20 ft 2 a receptacle was not required. The 2011 NEC has deleted this exception recognizing that electrically operated products could be used on decks, porches and balconies having an area less than specified in the exception. At least one receptacle outlet is required in each basement, garage and accessory building in one family dwellings. Accessory buildings have been added as a location where at least one receptacle must be installed. Many dwellings have additional buildings, other than garages, where electrical equipment is utilized. Section 210.8(A)(2) requires the receptacle to be GFCI protected. P&S Cat #s: 1595TRWR, 2095TRWR, 1595DS, 2095DS, WIUC10 P&S Cat #s: 1595TRWR, 2095TRWR, 1595DS, 2095DS

Page 16 Page 17 SECTION 210.52(I) Receptacle Outlets in Dwelling Unit Foyers SECTION 285.25 Type 3 Surge-Protective Devices (Transient Voltage Surge Suppressors) Receptacles must be installed in foyers. Receptacle outlets will now be required in foyers. This change recognizes that many homes are built with large foyers. Lamps and other cord and plug connected electrical equipment will be located in these foyers and receptacles are required for connection of this equipment. A foyer having an area of greater than 60 ft² must have a receptacle located in each continuous wall that has a width of at least 3 ft that is unbroken by a floor to ceiling window, a door or other similar opening. Type 3 SPDs are permitted to be installed on the load side of the branch circuit overcurrent protection. Type 3 Surge Protective Devices (SPD) installed on the load side of the branch circuit overcurrent protection were required by Section 285.25 of the 2008 NEC to be located at least 30 feet from the service. In the 2011 NEC this section has been revised to state that the requirement to install the Type 3 SPD at least 30 feet from the service is necessary only when specified in the manufacturers instructions. This change recognizes that a Type 3 SPD that has been subjected to additional testing may be installed anywhere in the branch circuit on the load side of the overcurrent protection. UL 1449, the Standard for Surge Protective Devices, requires a Type 3 SPD that has not been evaluated by the additional testing to be marked CAUTION Do not install this device if there is not at least 10 meters (30 feet) or more of wire between the electrical outlet and the electrical service panel. If this marking does not appear on the SPD or in the instruction sheet the Type 3 SPD may be installed anywhere in the branch circuit. Type 3 SPDs are typically cord connected power strips or receptacle type devices. P&S Cat #s: 885TR, 3232TR P&S Cat. #s: 5362GRYSP, TR5362GRYSP, PT5362GRYSP Wiremold Cat. #s: M6BZ, M6S

Page 18 Page 19 ARTICLE 310 Conductors for General Wiring SECTION 314.24 Outlet and Device Box Depth Article 310 has been reorganized and renumbered. The reorganization of Article 310 has resulted in the renumbering of most of the sections and tables and the relocation of some of the requirements. One notable change is that Table 310.16 for the allowable ampacities of conductors is now Table 310.15(B)(16) in the 2011 NEC. The ambient temperature correction factors have been removed from the allowable ampacity Tables and now appear relocated to new section 310.15(B)(2) and Tables 310.15(B)(2)(a) and 310.15(B)(2)(b). There have also been changes to the allowable ampacities for several different conductor sizes in Table 310.15(B)(16). A box must have sufficient depth for the installation of a large device or utilization equipment. This section of the code requires boxes to have sufficient depth to prevent damage to the conductors when devices or utilization equipment are installed as intended in the box. Section 314.24 has been revised for the 2011 NEC to include devices. This requirement previously applied only to utilization equipment. Section 314.24 specifies the depth of the box and the required clearance, taking into consideration a variety of conductor sizes. Wiremold Cat #s: V2400D, MC-V2400BC P&S Cat #s: S118R, S122R, P118R, P122R

Page 20 Page 21 SECTION 314.27(A) Outlet Boxes for Luminaires SECTION 314.27(C) Outlet Boxes for Ceiling Fans Outlet boxes are permitted to support luminaires in walls and ceilings. Section 314.27(A) has been revised to more clearly state the outlet box requirements for supporting luminaires at wall and ceiling outlets. Ceiling outlet boxes intended to support a luminaire must be able to support at least 50 pounds. A box may be used to support a luminaire weighing more than 50 pounds if the box is listed and marked for the maximum luminaire weight to be supported. A wall box intended to support a luminaire must be marked to indicate the maximum weight of the luminaire to be supported, if other than 50 pounds. An exception allows wall type luminaires weighing 6 pounds or less to be supported by device boxes, plaster rings or other boxes when the luminaire is secured by at least two No. 6 or larger screws. A box listed for support of a ceiling-suspended fan must be installed when a spare ungrounded conductor is provided. When a ceiling box is installed in a location where a ceiling-suspended fan may be installed and when a spare, separately switched, ungrounded conductor is provided, the box must be listed for support of a fan. Section 314.27(C) has been revised to recognize that when a ceiling box is installed under these conditions it is likely that a ceilingsuspended fan will be installed on the box. This requirement applies only to single and multi-family dwellings. P&S Cat #s: 55501, S120RAC, S120HAC, C118WAC, S118W www.passandseymour.com P&S Cat #s: 55025, 55501, 22200 www.passandseymour.com

Page 22 Page 23 SECTION 380.1 and SECTION 380.23 Multioutlet Assemblies SECTION 390.2 Underfloor Raceways Field assembled Multioutlet Assemblies must comply with wire bending space and pull box requirements. Article 380 provides the installation requirements for Multioutlet Assemblies. A new Section, 380.23, specifies the wire bending space and pull requirements for conductors in field assembled multioutlet assemblies. Section 380.23 does not apply to listed, factory assembled multioutlet assemblies. Section 380.23(A) requires insulated conductors installed in a field assembled multioutlet assembly to comply with the wire bending space specifications in Table 312.6(A). Where a multioutlet assembly is used as a pull box for 4 AWG or larger insulated conductors, Section 380.23(B) requires compliance with Section 314.28(A)(1) for straight pulls and Section 314.28(A)(2) for angle pulls. A new definition for Underfloor Raceway has been added to the code. Although the requirements in Article 390 for Underfloor Raceways remain the same, Section 390.2 now provides a definition. Underfloor Raceways are installed flush or beneath the floor surface and are intended for the installation of conductors. The underfloor raceway may be equipped with junction boxes for access to the conductors as well as a wide variety of fittings such as floor boxes and pedestals that allow power, voice and data connectivity. Section 380.23 applies only to field assembled multioutlet assemblies. There was concern that conductors could be damaged when installed in field assembled multioutlet assemblies. Another change to this Article is that Section 380.1 has been revised to add an informational note that directs the user to the definition of a Multioutlet Assembly in Article 100. Wiremold Cat #s: 20GB306, 20GB506 Wiremold Cat #s: D21210, D41210, 2-0, 4-0

Page 24 Page 25 SECTION 404.2(C) Switches Controlling Lighting Loads SECTION 404.9(B) Exceptions Nos. 1, 2, & 3 Grounding of Snap Switches, Dimmers and Similar Control Switches A grounded circuit conductor shall be provided at the switch location. This is a new section that requires the grounded circuit conductor of the lighting circuit to be provided at the switch location. Many lighting control devices, such as an occupancy sensor, require low levels of stand-by current for proper operation. In many installations, the equipment grounding conductor is the only available conductor that can be used as a circuit conductor for this low level stand-by current. The intent of this change in the code is to be certain that the lighting circuit grounded conductor is available for the proper operation of the lighting control device. This ensures that operation of the control device does not rely on connection to the equipment grounding conductor. The result is that there will be no undesirable current on the equipment grounding conductor. The use of electronic lighting control devices is expected to increase due to increased emphasis on energy efficient lighting systems. Exceptions to Section 404.2(C) allow for future installation of the grounded circuit conductor where there is access to the switch box in cable installations or where raceway is used to provide the conductors. In either case, the grounded circuit conductor can be provided after the initial installation. A snap switch, dimmer or similar control switch shall be connected to the equipment grounding conductor. This section requires snap switches, dimmers and similar control switches to be connected to the equipment grounding conductor by the means specified in Section 404.9(B)(1) and (2). This rule ensures that a metal faceplate installed on the switch will be grounded. There are three exceptions to this requirement: Exception No. 1 A replacement switch is not required to be connected to the equipment grounding conductor where the equipment grounding conductor is not available in the switch enclosure. Where the replacement switch is installed 8 feet vertically or 5 feet horizontally from ground or grounded metal objects it must have a nonconducting faceplate secured by nonmetallic screws or the circuit must be protected by a GFCI. Exception No. 2 listed switch assemblies of nonmetallic construction as described in this new exception are not required to be connected to the equipment grounding conductor. Exception No. 3 a snap switch with an integral nonmetallic enclosure as described in Section 300.15(E) is not required to be connected to the equipment grounding conductor. This type of switch is commonly known as a self contained device (SCD). P&S Cat #s: PTWSP250, WDT100, WSP250 www.passandseymour.com P&S Cat #s: PS20AC1, PT20AC1, CSB15AC1, TM870, 660

Page 26 Page 27 SECTION 404.14(F) Snap Switch Rating for Plug and Cord Connected Loads SECTION 406.2 and 406.14 Tamper-Resistant Receptacles in Child Care Areas Snap switches must be rated not less than the rating of the overcurrent device protecting the circuit. This new section establishes the rating of a switch used to control receptacle outlets. The switch must be rated not less than the rating of the overcurrent device protecting the circuit. The exception permits the switch to be rated not less than the receptacle rating where the switch controls only one receptacle. Tamper-resistant receptacles are required in child care facilities. Section 406.14 has been added to the code to require that all nonlocking 125 volt, 15 and 20 amp receptacles installed in child care facilities must be tamper-resistant. Section 406.2 defines a child care facility as a location where educational, supervision or personal care services are provided for more than four children under the age of seven. This change in the code recognizes that even in supervised facilities, such as child care areas, children have access to electrical receptacles and the potential for shock and burn incidents exist if a child inserts a foreign object into a receptacle. P&S Cat #s: PS20AC1, TM870, CSB15AC1, 2621, TM870, 660 P&S Cat #s: 3232TR, 885TR, TM8HWLTR, 1595TR, TR5262, TR26262 www.passandseymour.com

Page 28 Page 29 SECTION 406.4(D)(4) Arc Fault Circuit Interrupter Protection of Replacement Receptacles SECTION 406.4(D)(5) Tamper-Resistant Replacement Receptacles AFCI protection must be provided for replacement receptacles on branch circuits that require AFCI protection. This new section requires AFCI protection for a replacement receptacle. When a replacement receptacle is installed on a branch circuit that requires AFCI protection, the replacement receptacle must be provided with AFCI protection. Branch circuits that require AFCI protection are specified in Section 210.12. AFCI protection for the replacement receptacle may be provided by one of the following methods: - the replacement receptacle is a listed Outlet Branch Circuit type AFCI - the replacement receptacle may be protected by a listed Outlet Branch Circuit type AFCI receptacle located upstream from the replacement receptacle - a listed combination type AFCI circuit breaker providing protection of the branch circuit Replacement receptacles must be tamper resistant where tamperresistant receptacles are required by the code. Sections 406.12, 406.13, 406.14 and 517.18(C) require the installation of listed tamper-resistant receptacles in child care facilities, guest rooms, guest suites, specified areas of dwelling units and pediatric locations. Section 406.4(D)(5) is a new section that requires a replacement receptacle to be tamper-resistant when installed in any of the locations specified in the code that require a tamper-resistant receptacle. Section 406.4(D)(4) becomes effective January 1, 2014. P&S Cat #s: 1595TR, 885TR, TM8HWLTR, 3232TR

Page 30 Page 31 SECTION 406.4(D)(6) Weather-Resistant Replacement Receptacles SECTION 406.6 Recessed Receptacle Faceplates Replacement receptacles must be weather resistant where weatherresistant receptacles are required by the code. Section 406.9 requires the installation of listed weather-resistant receptacles in wet and damp locations. Section 406.4(D)(6) is a new section that requires a replacement receptacle to be a weatherresistant receptacle when installed in any of the locations specified in the code that require a weather-resistant receptacle. Faceplates for recessed mounted receptacles must effectively close the opening. This new requirement has been added to section 406.6 to ensure that faceplates for receptacles installed in a recessed box effectively close the opening. P&S Cat. #s: 1595TRWR, 2095TRWR, WIUC10 Wiremold Cat #s: CRFB4, RFB4, RFB9, RFB11

Page 33 Page 32 SECTION 406.9(B)(1) SECTION 406.12 Receptacles in Wet Locations Tamper-Resistant Receptacles for Dwelling Units Extra Duty While-In-Use Covers are required when the outlet box is Section 406.9(B)(1) requires a weatherproof cover for 15 and 20 amp, 125 and 250 volt receptacles installed in wet locations. These covers, commonly referred to as While-In-Use covers, provide protection for the receptacles both when a plug is inserted and when there is no plug inserted into the receptacle. This section has been revised to require an Extra Duty While-In-Use cover in installations where the box is supported from grade in other than one and two family dwellings. The intent of this revision in the code is to ensure that covers mounted on boxes supported by conduit, stanchions, wood braces or other free standing rigid supports can withstand the severe service conditions expected in these installations. The Extra Duty covers are evaluated to more demanding test requirements than general purpose covers. The covers must be listed and marked Extra Duty. P&S Cat #s: WIUCAST1, WIUC10 15A and 20A, 125V receptacles in dwellings must be listed tamper resistant. supported from grade. This section was previously added to the code in response to the numerous reported electrical injuries to children resulting from the insertion of conductive foreign objects into receptacles. Section 406.12 requires that 15 and 20 amp, 125 volt receptacles in all areas of dwellings specified in Section 210.52 must be tamper-resistant. Section 406.12 has been revised to allow exceptions to the tamperresistant receptacle requirement. The exceptions include receptacles located more than 5-1/2 feet above the floor, receptacles in a dedicated space for appliances that cannot be easily moved and receptacles that are part of a luminaire or appliance. The exceptions recognize that there are receptacles that cannot be easily reached by children and there are receptacles specified in Section 210.52 that are not considered to meet the receptacle installation requirements in dwellings. In addition, Section 406.12 has been revised to limit the tamper-resistant requirement to the nonlocking type of receptacle. P&S Cat #s: 1595TR, 885TR, TM8HWLTR, 3232TR

Page 34 Page 35 SECTION 406.13 Tamper-Resistant Receptacles in Guest Rooms and Guest Suites SECTIONS 430.42(C), 430.81(B) and 430.109(F) Cord and Plug Connected Motors 15A and 20A, 125V receptacles in guest rooms and guest suites must be listed tamper-resistant. Section 406.13 is a new Section that requires nonlocking 15 and 20 amp, 125 volt receptacles in guest rooms and guest suites to be tamper-resistant. Guest rooms and guests suites are defined in Article 100 of the NEC. These locations are often occupied by children and present hazards similar to other locations such as dwellings that require tamper-resistant receptacles. Motors may be connected to the branch circuit by a plug and receptacle or a cord connector. The motor disconnect may be a plug and receptacle or a flanged surface inlet and a cord connector. Both of these sections have been revised to recognize that a motor may be connected to the branch circuit by not only a plug and receptacle but also by a cord connector. Per Section 210.50(A), a cord connector may be supplied by a permanently connected cord pendant. Section 430.109(F) has been revised to include a flanged surface inlet and cord connector as a motor disconnect means. Previously, this section recognized only a plug and receptacle as the disconnect means. P&S Cat #s: 1595TR, 885TR, TM8HWLTR, 3232TR, TR5262, TR26262 P&S Cat #s: 5262, PS5266XGCM, PS5269XGCM, 5278SS, WPG1

Page 36 Page 37 SECTION 517.13(B)(1)(2) Grounding of Receptacles in Patient Care Areas of Health Care Facilities SECTION 517.16 Isolated Ground Receptacles in Health Care Facilities This section is restructured to provide the requirements for the connection of the insulated equipment grounding conductor in patient care areas. The revisions to Section 517.13(B) are intended to more clearly state the requirements for the connection of the insulated equipment bonding conductor to receptacles, metal boxes and non-current carrying conductive surfaces. An exception permits an equipment bonding jumper to connect the receptacle and box to the equipment grounding conductor. Isolated ground receptacles are no longer permitted in patient care areas. Section 517.16 has been revised to prohibit the use of isolated ground receptacles in patient care areas. There was concern that the redundant grounding required by Sections 517.13(A) and (B) may not be adequately achieved when using isolated ground receptacles. P&S Cat #s: TRIG8300, IG8300 P&S Cat #s: TR62HI, 8300HI

Page 38 Page 39 SECTION 517.18(B) and 517.19(B)(2) Patient Bed Location Receptacles in Health Care Facilities SECTION 517.20(A) Receptacles in Wet Procedure Location Patient Care Areas Patient bed location receptacles may be single, duplex or quadruplex. The requirements for patient bed receptacles in general care areas and critical care areas have been revised to include quadruplex receptacles, in addition to single and duplex receptacles, as the type of receptacles that may be installed to meet the minimum receptacle requirements for theses areas. The power distribution system must limit the ground fault current. Section 517.20(A), titled Receptacles and Fixed equipment, requires the power distribution system in wet procedure patient care areas to either limit the ground fault current due to a first fault to a low value without interrupting the power, or, to interrupt the power supply if the ground fault current exceeds 6 ma. The revision to this section closely parallels the wording in NFPA 99, Section 4.3.2.2.8.1. P&S Cat #s: 420HI, 8201, 8200HI P&S Cat #s: 8300HI, PTTR8300, 8300W, PT8300

Page 40 Page 41 SECTION 518.3(B) Temporary Wiring in Exhibition Halls SECTION 525.23 GFCI Protection for Carnivals, Circuses, Fairs Ground fault circuit interrupter protection required in exhibition halls. Temporary wiring in exhibition halls may be installed in accordance with Article 590, with the exception that the ground fault circuit interrupter (GFCI) requirements of 590.6 do not apply. However, section 518.3(B) has been revised to state that all other GFCI requirements in the code apply in this type of installation. An additional revision to this section requires that portable GFCIs must meet the requirements for a listed product. This effectively means that portable GFCIs should be listed products. GFCI protection is required for 15A and 20A, 125V nonlocking receptacles. Section 525.23(A) has been rewritten to clearly state in enforceable language the requirement for GFCI protection of 15A and 20A, 125V receptacles. Section 525.23(B) previously stated that receptacles are not required to be GFCI protected if the receptacles are of the locking type and they are used for the quick connect and disconnect of equipment. A revision to this section includes the additional condition that the receptacles that are unprotected by a GFCI must also not be accessible from grade level. P&S Cat #s 1594CMM P&S Cat #s: 1595, 2095

Page 42 Page 43 SECTION 550.13(B) GFCI Protection of Receptacles in Mobile/Manufactured Homes SECTION 550.13(F)(1) Receptacles Near Bathtubs and Shower Stalls in Mobile/Manufactured Homes 15A and 20A, 125V receptacles requiring GFCI protection. Section 550.13(B) specifies the receptacles that must be GFCI protected in mobile and manufactured homes. This section has been revised to delete the exception which allowed receptacles not to be GFCI protected where the receptacles were installed for use with appliances in a dedicated space. This section now references the exceptions in Section 210.8(A) as the only permitted exceptions. Receptacles shall not be installed within or directly over a bathtub or shower stall. This section restricted the installation of a receptacle within a bathtub or shower stall. In addition to the previous wording of the requirement, the section has been revised to make it clear that a receptacle may not be installed directly over a bathtub or shower stall. P&S Cat #s: 1595, 2095 P&S Cat #s: 1595, 2095

Page 44 Page 45 SECTION 550.25 AFCI Protection of Branch Circuits in Mobile/Manufactured Homes SECTION 551.47(L) and SECTION 552.48(K) Receptacle Faceplates in Recreational Vehicles and Park Trailers Additional 15 and 20A, 120V branch circuit outlets must be AFCI protected. This section previously required AFCI protection for 120V branch circuits that supply 15A and 20A receptacles installed in bedrooms. In addition to the AFCI protection for bedroom branch circuits, Section 550.25 has been revised to require AFCI protection for 120 volt branch circuits supplying 15A and 20A receptacles in family rooms, dining rooms, living rooms, parlors, libraries, dens, sunrooms, recreation rooms, closets, hallways, or similar rooms or areas. The AFCI protection must comply with Section 210.12(B). Faceplates must comply with Section 406.5(A) and (C). The title of Section 551.47(L) and Section 552.48(K) has been changed to Receptacle Faceplates. Both sections have been revised to refer to Section 406.5(A) and (C) for the specific requirements for metallic and nonmetallic faceplates. P&S Cat #s: 5262, TP8

Page 46 Page 47 SECTION 552.59(A) Park Trailer Outdoor Receptacles and Switches SECTION 590.4(D)(2) Receptacles in Temporary Installations Switches and receptacles must meet outdoor installation requirements. In the 2008 NEC, outdoor receptacles on park trailers had to be provided with a gasketed cover for use in wet locations. Section 552.59(A) has been revised to require outdoor receptacles to comply with Sections 406.8(A) and (B). A requirement for outdoor switches to comply with Section 404.4 has also been added to this section. These revisions make certain that the appropriate protection is provided for switches and receptacles installed outdoors. Receptacles in wet locations in temporary installations must meet the requirements in section 406.9(B)(1). Section 509.6(D)(2) is a new section that requires receptacles that are in wet locations in temporary installations to comply with Section 406.9(B)(1). This change in the code recognizes that receptacles in temporary installations will be exposed to the same wet locations environment as any other outdoor installation and must be provided with the necessary protection to ensure continued safe operation of the receptacle. P&S Cat #s: WR20TR, WR5362 P&S Cat #s: WR20TR, WR5362

Page 48 Page 49 SECTION 604.6(A)(5) Manufactured Wiring Systems SECTION 625 Electric Vehicle Charging System Section 604.6 provides the construction requirements for Manufactured Wiring Systems. Section 604.6(A)(5) is a new section that specifies listed prewired, modular, surface raceway as one of the construction components of a manufactured wiring system. This type of surface raceway construction when used as a manufactured wiring system has a rating of 600 volts, 20 amps. A listed surface raceway intended for use as a manufactured wiring system is evaluated to UL 183, the Standard for Manufactured Wiring Systems. The code also covers other types of surface raceway products, such as Multioutlet Assemblies in Article 380 and Surface Metal and Nonmetallic Raceways in Articles 386 and 388. These products are evaluated to UL5 and UL5A, the standards for metal and nonmetallic surface raceways. A prewired, modular, surface raceway that is a component of a Manufactured Wiring System must meet the requirements of Article 604. Other surface raceway type products must meet the requirements of the code article that applies, such as, Article 380, Multioutlet Assemblies, Article 386, Surface Metal Raceways and Article 388, Surface Nonmetallic Raceways. Article 604 applies only to Manufactured Wiring Systems. Article 625 includes a definition for the Plug-In Hybrid Electric Vehicle (PHEV). A PHEV is a type of electric vehicle powered by both an electric motor and an internal combustion engine. Both all-electric vehicles and PHEV s can be charged using cord connected Electric Vehicle Supply Equipment. These are electric vehicle chargers that have a plug for connection to the EV inlet and also have a means for connection to the premises wiring to provide power. The 120 volt charger is typically a portable unit that plugs into a standard NEMA 5-15 or 5-20 receptacle. There is also a 240 volt charger that provides a faster charge time. The NEC requires that all chargers have a number of integral safety features, including personnel protection against electric shock. Wiremold Cat #s: ALA3800 Series, ALA4800 Series P&S Cat #s: L1EVSE, L2EVSE16

Page 51 Page 50 SECTION 680.21(C) SECTION 680.32 GFCI Protection of Pool Pump Motors Receptacles Near Storable Pools 20' Outlets supplying pool pump motors must be GFCI protected. Receptacles within 20 feet of a storable pool must be GFCI protected. The requirement for the GFCI protection of pool pump motor outlets has been moved from Section 680.22(B) to Section 680.21(C). The requirement remains the same except that the voltage ratings have been changed from 120 or 240 volt to 120 through 240 volt. GFCI protection is required for both plug connected and direct connected pool pump motors. P&S Cat #s: 1595TRWR, 2095TRWR, WIUC10, 1595DS, 2095DS 125 volt, 15 and 20 amp receptacles within 20 feet of the inside walls of a storable pool must be GFCI protected. The change to this section adds the 15 and 20 amp ratings of the receptacle which were not previously specified. P&S Cat #s: 1595TRWR, 2095TRWR, WIUC10, 1595DS, 2095DS

Page 52 Page 53 NOTES NOTES

Page 54 NOTES

For product and application information, please call the Legrand/Pass & Seymour Technical Assistance Group at 1-800-223-4185 /passandseymour

designed to be better. 2011, Legrand/Pass & Seymour CTM1095 7/11 2/11 AGI/CGXTP AGI/DG For additional technical or application-specific information, call 800-223-4185 or visit our website at /PassandSeymour. We re eager to put our expertise to work for you. Distributed by: P.O. Box 4822 Syracuse, NY 13221-4822 800-776-4035 /PassandSeymour Legrand Canada 570 Applewood Crescent Vaughan, ON, L4K 4B4 Phone: 905.738.9195, Fax: 905.738.9721 www.legrand.ca