IMR EX610. Portable Gas Detector. Operation Manual

Similar documents
E1000 Portable gas detector

IMR IX176 Portable Gas Detector User Manual

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

TC100N. Fixed Gas Detector Operation Manual

QD6310. Fixed Gas Detector Operation Manual

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

ALTAIR 5X Multigas Detector Product Specification

GasAlertMicroClip X3 Specifications

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

CP01 Fixed gas detector

Safe Operation Manual. Honeywell IQ Force Gas Detector

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

EST User Manual. (Please read this manual carefully before using)

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Operate the Mutli-Gas Monitor PID

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

For the Safety of Your

1.1 Definitions of alert icons. For your safety

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

G450. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

RAE Systems Systems. User Presentation. October Protection Through Detection

M004 combustible gas module

BST-MG01 Single Gas Detecting Alarm Manual Instruction

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector

Using the QRAE Plus personal multigas monitor

ALTAIR 4 Four Gas Multigas Detector

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

Portable type of Carbon Dioxide Detector Model: GT220

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

Dräger X-am 7000 Multi-Gas Detection

Operator s Manual. 1, 2, 3, and 4-Gas Detector

Sirius MultiGas Detector

Operator s Manual. 1, 2, 3, and 4-Gas Detector

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

IT S WHAT S INSIDE THAT

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

SP-220. Features. Combustible handheld gas leakage detector

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

X5 Personal Gas Detector. Operating Manual

KAE Gas Alarm Operation Manual

Warranty Registration

Dräger Pac 7000 Single-Gas Detection Device

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Personal Single Gas Monitor. Activation Operation Troubleshooting

User Manual. Single Gas Detector

ALTAIR 5X Multigas Detector

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

GasAlert. Introduction. WWarning. Table 1. GasAlert Models. Gas Monitored

Dräger X-am 5000 Multi-Gas Detection

PERSONAL COMBUSTIBLE GAS DETECTOR

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Model D12-IR. Digital Gas Transmitter...

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

KAB Gas Alarm Operation Manual

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

T.ex Single Gas Detector VISA

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

SC-01 Operator s Manual

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

Multi-gas Monitor. Product Manual Set-up Operation Service. Part Number: Version 12

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

RAE Systems RAE Systems RAE Systems Presented by David Lucha RAE Systems Protectio n Through Detection

SIL 2. Ultima X Series Gas Monitors CERTIFIED

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

ALTAIR 5X Multigas Detector

Two-Channel Gas Controller

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Model GX-2001 Canadian Version Operator s Manual Part Number: RK Revision: 0 Released: 1/17/05

GAS DETECTORS EXPLOSIMETERS/CATHAROMETERS EX 2000/EX 2000 C/GD 2000/GDP Your environment, your safety, let s master them together

Instruction Manual Eagle Series

Dräger X-am 7000 Multi-Gas Detection

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

B -MG0 i gle G Detecti A rm Ma a nstructio. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Bacharach Bodyguard 4 User's Guide

MICRO III (G202 / G202s / G212) Single Gas Detector

QUICK REFERENCE GUIDE

Portable Gas Leak Detector SP-220 Series TYPE F Operating Manual

Ml ['l>l'ol]

Dräger X-am 2500 (MQG 0011) Technical Manual

Transcription:

IMR EX610 Portable Gas Detector Operation Manual IMR Environmental Equipment, Inc. 3634 Central Ave. St. Petersburg, FL 33711 Phone: 727-328-2818 email: info@imrusa.com Read this manual carefully before using the detector. 1

2

Table of Contents SAFY INFORMATION... - 1-1. BRIEF INTRODUCTION... - 3-2. MAIN FUNCTION AND TECHNICAL SPECIFICATION... - 3-2.1 MAIN FUNCTION AND FEATURES... - 3-2.2 TECHNICAL SPECIFICATION... - 4-3. CONFIGURATION AND FUNCTION... - 5-3.1 APPEARANCE... - 5-3.2 DISPLAY INFORMATION... - 6-3.3 BUTTONS... - 7-4. USING THE DETECTOR... - 7-4.1 TURN ON THE DEVICE... - 7-4.2 TURN OFF THE DEVICE... - 9-4.3 IMPACT TEST...- 10-4.4 ALARM... 10 4.5 ALARM INFORMATION... 12 4.6 CHECK DEVICE STATUS... 14 4.7 AUTO ZERO CALIBRATION... 14 4.8 CALIBRATION AND ALARM LEVEL ADJUSTMENT...- 15-5. POWER CHARGE... 19 6. USB COMMUNICATION (OPTIONAL)... 19 3

7. USING AND REPLACEMENT OF THE SENSOR... 19 8. USING OF ACCESSORIES... 20 9. TROUBLE SHOOTING GUIDANCE... 21 10. PRECAUTIONS... 21 4

Safety Information Please read the following security information carefully before using the detector: Do not use the damaged gas detector. Before using the detector, please check whether there's crack or parts missing. If the detector is damaged or uncompleted, please contact with us or our agent immediately. We highly recommend do "impact test" as in 4.3 (put the detector in the target gas which the concentration is higher than high-alarm level, you can use standard gas) to make sure the good performance of detector. Calibrate as in 4.8 if the test value is beyond detection range. Do "impact test" periodically to confirm sensor's ability of good response to gas. Ensure that the audio, visual and vibration alarms working properly Use only accessories specially designed for EX610 or accessories approved by the distributor. Use only the charger supplied with the detector, Do not recharge the detector in hazardous area. For Detectors with catalytic or semiconductor sensor, if to be long time exposed to the target gas which concentration is beyond its detecting range, will increase its working load, thus badly affect its function or damage the detector. Detectors with catalytic or semiconductor sensor will be poisoned if exposed to environment containing lean chromate, sulfur compound, phosphorus compound or silicon; do not use the detector in such environment. Please don't expose the device to the environment which consists of hydrogen sulfide, halogenated hydrocarbon or high corrosive gases for long time. Otherwise, it will restrain the response of the gas sensor and reduce the sensitivity. If the - 1 -

device has to be used in the above environment, please follow Clause 4.3 to carry out the Impact Test before using it. Please don't expose the device to the environment which has electric shock, strong magnetic field or serious continuous mechanic shocking. There's lithium battery inside the detector and do not put the used-battery together with rubbish. The used-battery should be handled by the qualified recoverer or dangerous goods handling operators. Unauthorized disassemble, adjustment or repair of the gas detector is forbidden Avoid falling from high or severe vibration to the detector For any problem beyond the description of this manual, please contact the distributor or the manufacturer for help. - 2 -

1. Brief Introduction EX610 portable single gas detector (hereinafter refer to as detector ) is an intrinsically safe instrument which can make continuous detection to combustible and toxic gases. It is suitable for combustible and toxic gas leakage detection in underground pipe or mines, and keeps the workers safe, prevents the facilities from being destroyed. The detector, adopting excellent-quality sensor, makes detection in the way of natural diffusion. It has good sensitivity and repeatability. The detector adopts embedded MCU controller, easy to operate. The shell adopts special high strength material and anti-smooth rubber, with the characters of water-proof and dust-proof. 2. Main Function and Specification 2.1 Main Function and Features Advanced 16-digit MCU control with low power consumption; Wide view LCD screen; Adjustable high alarm and low alarm setting; Adjustable calibrating level, easy for customers to calibrate. Device with LEL range has high-concentration protection function Self-test for the combustible gas sensor; Under-voltage alert; Real time clock display Real-Smart Sensor module design, easy for maintenance and replacement; Self-adjustment function, reduce the detecting error. Audio, visual and vibration alarming method; Data uploading STEL and TWA alarming for toxic gases - 3 -

Self-test after power on; advanced fault diagnosis and auto reset; Password management to avoid wrong operation; Intrinsically safe. 2.2 Technical Specification Range: See attached table 1. Gas Detected: combustible gas, toxic gas, oxygen Response time: Semiconductor, Catalytic, Thermal conductivity t 90 <30s Oxygen, Carbon monoxide, hydrogen sulfide t 90 <30s Indication method: LCD displays the real time data and status; Alarm method:audio, video and vibration alarm Working Temperature: Cumbustile Gas: -40 ~70 Toxic Gas -20 ~50 Working humidity: 95%RH no condensation Power source: DC3.7V (Lithium battery 1800mAh LIS103450) Charging time: 4~6 hours Continuous working time: 8 hours (for combustible gas) 300 hours (for toxic gas under temperature of 20 ) Protection Grade: IP65 Weight: about. 191g (with battery) Dimensions: 108.4mm 61mm 36mm (L W H) - 4 -

3. Configuration and function 3.1 Appearance NO NAME NO NAME 1 Alarm light 4 Sensor Port 2 LCD Screen 5 Button 3 Buzzer port 6 Buckle - 5 -

3.2 Display information NO 1 Battery Condition 2 Lock on or Password 3 Buzzing Status 4 Vibrating Status 5 Alarm information 6 Warning or Max Value 7 Gas Concentration 8 Error 9 Record 10 Clock Icon 11 Zero Calibration FUNCTION 12 Calibration Point or Calibration Status 13 Communication icon 1 14 Data Setting 15 Unit Note: 1only appear when your device has data uploading function. - 6 -

3.3 Buttons Button Function Press and hold for more than 3 seconds to turn on the device. Press to cancel the data setting. When power off, press and for more than 5 seconds to calibrate the device. Hold for seconds to turn off the device. Press to adjust the value Press to enter setup for selected item Press and for over 3 seconds to set the data. Press and to review temperature, time, STEL, TWA1and Max Value 2 Press to check the setup Press to save the setting. In alarming status, press to cancel audible alarming and vibration. Notic: 1Only available for toxic gas detector 2Oxygen has Max/Min exposer value 4. Using the detector 4.1 Turning ON the Detector In power off status, hold for over 3 seconds and the device will be turned on. Then the device starts self test as follows: - 7 -

1)All the data and figures displayed; back light on; 2)Buzzer gives a sound; 3)All the alarming signal function; 4)Version number displayed. 5)Date & Time display 6)Gas type Year Date Time 7)L-alarm and H-alarm L-alarm H-alarm 8)Display STEL and TWA levels: STEL TWA - 8 -

Note: Only available for Toxic gas. 9)Self test pass After self test, the device starts a short warm-up time countdown (3-30 seconds). After warm-up, the screen display as below which means the device finish starting up. Note: If self test failed, it will display relative information. Please refer to the "Time fault alarm" and "Storage fault alarm" in the manual, if self test passed, detectors will automatically choose a warm up time from 3s~30s basing on different sensors. 4.2 Turn off the device In power on status, when the device is not in detection status, hold and the screen displays as follows: The buzzer gives beep sound. After 3 seconds, when the screen displays as follows, please release and the detector is turned off. - 9 -

Note: When the device is not in detection interface, you can press again and again till the device exits to detection interface. 4.3 Impact Test Perform an Impact Test before each day s use to check if the detector functions properly. Method: After turning on the device, put the device into gas which concentration is higher than the H-alarm level or standard gas. If the device works normally, then the user can carry the device to enter the detection area. If the reading on the screen is beyond the error range, please follow Clause 4.8 to re-calibrate the device. If the device doesn't response or displays abnormally, please contact the seller for solution. 4.4 Menu Description The menu includes the following:: Zero translation. Date and time setting. Vibration on / off Keytone on/off Communication mode1 Password setting Note: 1 only available when the purchased instrument is supplied with USB communication function. In normal detection status, press both and, the screen displays as follows. After 1 second, it enters into menu interface. - 10 -

Press instruction on each item. Display to adjust the item you need. The following is the detailed Meaning and function When these figures are flickering, press to zero the detector. When these figures are flickering, press to set time. When it appears, press turn on / off the sound. to When the it appears; press to turn on / off vibration. 1 When the it appears; press to enter communication mode1. When it appears, press to set the password (initial passwords is 0000). Note: 1 only available when the purchased instrument is supplied with USB communication function. Press to make adjustment for selected items, then press to confirm the changes or press to exit the selected item without saving the change; below are the meanings of the items - 11 -

Display Meaning To turn off the function To turn on the function 4.5 Alarm information Alarm type L-alarm: Slow sandhi alarm sound Flickering alarm lights Vibration 1 H-alarm: Fast sandhi alarm sound Flickering alarm lights Vibration 1 High concentration protection: Slow sandhi alarm sound Flickering alarm light 2 Display Sensor fault alert: Fast sandhi alarm sound STEL Alert: Slow sandhi alarm sound Flickering alarm lights Vibration 1-12 -

TWA Alert: Slow sandhi alarm sound Flickering alarm lights Vibration 1 Over range Alert: Slow sandhid alarm sound Alarm LED flickering Time fault: The device will try to solve this problem by itself. If solved, the device will enter into time setting after power on. The user can set the time. If failed, the device will turn off automatically. Please contact the seller for solution. Storage fault: The device will try to solve this problem. If solved, the device will enter into calibration status after power on. Please follow Clause 4.7 to set the device. If failed, the device will turn off automatically. Please contact the seller for solution. Low voltage alert: Sandhi alarm sound once every 1 minute. In severe under-voltage, the device can work 15 minutes at most. Please charge the device in safety area. Otherwise, it will turn off automatically. Note: 1Only available when vibration function is on. 2Only available for Combustible Gas detector. - 13 -

In continuous alarm status, user can press to turn off audio alarm and vibration. The and icon on the screen will flicker. 4.6 Status Checking In detection status, press, the screen displays in turns the temperature, time, Max. Value, Min Value2, STEL Value1, TWA Value2, etc Note: 1 Only availiable for toxic gas detector 2 Only availiable for Oxygen detector 4.7 Zero calibration If the display in the clean air is not zero, please follow the following steps to calibrate zero point. In detection status, hold both and for more than 1 second till the screen indicates the setup interface, During this period, the screen will display as follows: Status When holding both and, it displays as the right picture. After 1 second, it will enter into the next status. When the display show the right picture, press to enter into the next status. When the device is auto-calibrating zero, it displays as the right picture, calibration will be finished in 5s and then it will return to detecting interface. Display - 14 -

Note: Zero calibration must be in the clean air. Otherwise, it will influence the detection accuracy. Oxygen detectors use a concentration of 20.9%VOL for the above calibration as in air. 4.8 Calibration and alarm level adjustment If the detector needs to be re-calibrated or adjusted the alarm level, please follow the below steps. 1)Enter into the mode of calibration and alarm level adjustment. In power off status, hold both and for 3 seconds, the detector starts self test and then a short delay. Then it indicates to input the password. The display is as follows: Input the correct password to enter into the calibration mode. Note: As all the parameters of this mode may endanger the safety of the operator, so please operated prudently. The detector will power off automatically if there is no operation within 5s after indicating inputting the password or the input password is incorrect. So please input the correct password in time. If you forget the password, please contact to the supplier. 2)Warming Up After inputting the password, the device will count down to warm up the gas sensor. The counting down time will be different depending on different gasses(30s~90s). During this status, you can press to skip the calibration procedure and enter into the mode of Alarm Level Setting(see following items 6,7). 3)Zero point adjustment mode - 15 -

In this mode, the detector will display a figure which is detected currently as shown in the following chart: At this status, if there is no operation within 1 minute, the detecor will accept the present concentration as the zero point, and then enters into the mode of SPAN Calibration. During this status, you can press to skip the calibration procedure and enter into the mode of Alarm Level Setting(see following items 6,7). During this status, if press it will display the AD value, then press to return to display current gas concentration. Warning: This operation should be carried out in the clean air. Otherwise the accuracy of the detector will be affected severely. When entering into the next mode, it will displays E if the air is not clean or the sensor is damaged. So please change to another place for adjustment or replace the sensor. 4)Span point adjustment In this mode, the screen displays a set of flickering figures. Press or to modify this figure. This figure is the standard sample gas level with which the operator will need to calibrate the detector, as shown in the following chart: - 16 -

If there is no operation within 10 minutes, the detector will consider as preparation work not ready, and then display Calibration Error and enter into Alarm Level Setting mode(see following items 6,7). If gas has been input within 10 minutes, the detector will consider the figure showing on the display as the concentration of the calibrating gas, and then enter into the SPAN Calibration mode. Note: See Chart 1 for the available adjustable range of the calibration gas concentration. 5)SPAN Calibration In this mode, the detector displays a concentration value detected as shown in the following chart: At this time, please cover the gas response hole with the calibration cap and input the calibration gas. Within 30 seconds, if the detector detects the calibration gas, the detector will start up the calibration data analysis procedure by itself. And the detector will automatically adjust the conversion arithmetics till all the standard gas complete the response. Then the detector saves the best arithmetics and complete the calibration. After that it enters into the L-alarm set up. Note: Please contact the supplier or local service center to get the flow rate of different calibration gases. In this mode, please avoid touching any buttons, otherwise the accuracy will be effected badly. If the detector indication figure can t reach half the calibration figure within 30s, or the gas concentration is beyond the maximum drift range of the sensor, the icon will light, which means the gas is not proper for calibration or the sensor is damaged. Please replace the gas or the sensor. - 17 -

The calibration of O2 sensor will jump over step 3. and 4. 6)Low Alarm Level Setting In this mode, the L-alarm level can be adjusted, and the screen displays as the following chart, with the figure flickering. Press or to adjust the flickering figure according to your need, and then press to hold the figure and complete the set up. meanwhile it enters into the H-alarm set up. If you don t need to adjust the setting, press L-Alarm setting and enter into H-Alarm setting. to skip the Note: Adjusting range of L-Alarm for different gases please find Chart 2. 7)High Alarm Level Setting (H-Alarm) In this mode, the H-alarm level can be adjusted, and the screen displays as the following chart, with the figure flickering. Press or to adjust the flickering figure according to your need, and then press to hold the figure and complete the set up. After that the device will turn off automatically. - 18 -

Note: Adjusting range of H-Alarm for different gases please find Chart 1. 5. Recharging When the battery power is low or the detector cannot work normally due to the low voltage, please charge in time. Note: You can t activate the detector when it is being charged in the status of power off. In order to avoid fire or explosion, please do not charge the detector when it is working in the working spot. Please do not charge when the detector is power on, otherwise the charge speed will be affected. 6. Data Uploading (Optional) Connect the detector to PC through the USB cable. Then open the software for uploading the detection record. Note: This function can be available only when the product you bought has the function of data communication. 7. Using and Replacement of the sensor As the sensor of the detector is modularized, so please pay attention to the life of the sensor. When it is overdue, please replace it. Every half year you need to calibrate the sensor in order to guarantee the accuracy of the detector. The sensor replacement should be carried out by the seller or the local repairing department. If there is no distributor or repairing department, please replace the sensor after you get permission from the manufacturer. The sensor should be replaced with the same modularized sensor supplied by the manufacturer. - 19 -

8. Using of Accessories For the user s convenient, we equip buckle, crocodile buckle and flying ring with the detector. If you need the above accessories, you can fix them on the back shell of the detector with the screw. If you mainly use the buckle, please take out the crocodile buckle and then fix the buckle. 1 Buckle 3 Fixing hole 2 Flying ring 4 Screw hole - 20 -

9. Trouble Shooting Guidance Trouble Possible Reason Solutions Unable to turn on the detector No response to gas Display not correct Wrong time display Zero calibration function not available It displays -0 If it displays Too low voltage Detector dead PCB fault Warm up not finish PCB fault Overdue sensor Not calibrated long time Battery used up Electromagnetic interference Too much drift Too much drift Charge in time Contact the seller Contact the seller Wait till it finishes Contact the seller Replace the sensor Calibrate in time Charge and reset the time Reset the time Calibrate or replace the sensor Calibrate or replace the sensor Sensor fault Replace the sensor 10. Precautions 10.1. Prevent the detector from falling down high places or serious vibration. 10.2. When there is interferential high-concentration gas, the detector may not work normally. 10.3. Please operate and handle in strict accordance with the - 21 -

introduction, otherwise the result may be incorrect or you may destroy the detector. 10.4. The detector should not be stored or used under the circumstance with caustic gas (such as CL2 gas), or be use or stored under the other rigorous circumstances (including excessive high and low temperature, higher humidity, electromagnetic field and strong sunlight). 10.5. After long-term use, if there is dust on the surface of the detector, please clean it lightly with clean soft cloth, instead of caustic impregnant or hard objects. Otherwise, the surface of the machine may be scratched. 10.6. To assure the testing accuracy, the detector should be calibrated termly, and the calibration period should not more than one year. 10.7. Do not recharge nor upload data in dangerous area. 10.8. Please send the abandoned Li batteries from the detectors to the appointed places or our company. Don t throw them into the dustbin at random. 10.9. Any malfunction not being included in this manual, please contact us for solutions. - 22 -

Table--Gas List Gas Detecting Range L-Alarm setting range H-Alarm setting range L-Alarm H-Alarm TWA STEL CH 4 0-100%LE L 10%LEL~ 25%LEL 25%LEL~ 80%LEL 20%LEL 50%LEL N/A N/A C 3H 8 0-100%LE L 10%LEL~ 25%LEL 25%LEL~ 80%LEL 20%LEL 50%LEL N/A N/A H 2 0-100%LE L 10%LEL~ 25%LEL 25%LEL~ 80%LEL 20%LEL 50%LEL N/A N/A H 2 0-1000ppm 20ppm~ 150ppm 150ppm~ 500ppm 35ppm 250ppm N/A N/A H 2S 0-100ppm 5ppm~ 15ppm 15ppm~ 30ppm 10ppm 15ppm 10ppm 15ppm CO 0-1000ppm 25ppm~ 100ppm 100ppm~ 500ppm 35ppm 200ppm 35ppm 200ppm CO 0-2000ppm 25ppm~ 100ppm 100ppm~ 500ppm 35ppm 200ppm 35ppm 200ppm O 2 0-30%vol 16%vol~ 19.5%vol 22.5%vol~ 24%vol 19.5%vol 23.5%vol N/A N/A C 2H 5OH 0-100%LE L 10%LEL~ 25%LEL 25%LEL~ 80%LEL 20%LEL 50%LEL N/A N/A NH 3 0-100ppm 20ppm~ 30ppm 30ppm~ 70ppm 25ppm 50ppm 25ppm 35ppm CL 2 0-20ppm 3ppm~ 10ppm 5ppm~ 15ppm 5ppm 10ppm 0.5ppm 1.0ppm SO 2 0-100ppm 1ppm~3ppm 3ppm~ 10ppm 2ppm 5ppm 2ppm 5ppm 1

2