AC-046 Peltier-Thermoelectric Air Cooler

Similar documents
AC-162 Peltier-Thermoelectric Air Cooler

SEALED ENCLOSURE COOLING

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

Enclosure Temperature Control

SEALED ENCLOSURE COOLING

Ambient (ºF) Temperature Rise Above

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

Enclosure Temperature Control

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

SPECTRACOOL Indoor & Outdoor Air Conditioners

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

SPECTRACOOL Indoor & Outdoor Air Conditioners

TEC PELTIER TEC 30X30 4MM 2.5A x30 4. TEC PELTIER TEC 30X30 3.2MM 3.9A x30 3.

Product Management, Rev 3 December 2009

Users Manual Pury 250e Gas Purification System

GENESIS Indoor Air Conditioners

Cabinet Cooler Systems

Top-Mount Air Conditioners

VA G 052 S

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

Climate Control Quick Reference

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

Safe Enclosure Cooling

Project Number: P15441

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S

Quality Enclosures and cooling solutions for every environment

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP

HEATING. Anticondensation Heaters

SPECIFICATION FOR APPROVAL

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

NEW! TSX Series high-performance undercounter refrigerators

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

BULLETIN 600 SINGLE PHASE

Product Information Packet

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

NEW! TSX Series high-performance undercounter refrigerators

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

WHITE PAPER: Cooling Industrial Enclosures with Filter Fans

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

Premier External TD. Installation Manual INS352-3

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

P266 Series Single-Phase Condenser Fan Speed Control

International Engineering Research Journal Performance assessment of multistage thermoelectric cooling module based refrigerator

High Efficiency Motors

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

AIR TO AIR HEAT EXCHANGERS

QAW70. Room Unit. Building Technologies. for use with heating controllers

1592P01. for liquids in piping DN

INSTRUCTION MANUAL (ATEX / IECEx)

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

Application. Specifications. Finish

PROAIR Harsh Environment/Wash Down Air Conditioners

Construction. Electrical. Enclosure Protection IS19 - Industry Standards UL Recognized Type 3, 3R, 4 & 12 IEC IP56

TIMER CONTROLLED DRAINS

ENCLOSURE COOLING. Glossary

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

Eliminator Series. SE400E and SE800E ELECTRONIC AIR PURIFICATION SYSTEM. Electrostatic Precipitators for Commercial Applications

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

Performance Data. curus Component Recognized; File No. E IP 20

Installation Instructions

Global Series Screw Air Compressors Life source of industries

EG Series Screw Air Compressors Life source of industries kw

Chargebuster Ion Gun Installation, Operation and Maintenance

PT9420 (Extended Range)

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

"SAN ACE MC" for Pentium *

X10 Mini, Midi & Maxi

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Product Information Packet

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

Positive Temperature Coefficient (PTC2) Heater Manual

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

AC Backward Curved Motorized Impellers

for Refrigeration Applications

Guide To Troubleshooting INEFFICIENT COOLING FANS

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Technical Manual. Operation and installation cooling units PKS 3000 SERIES 115V / 230V / 460V. Version 1.0, March 2018

INTRODUCTION / TABLE OF CONTENTS

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

The A-series Eletta Flow Monitor with local indication and analog output

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Comparative analysis of power supply single speed air mover and an entire electronics enclosure system fan

READ AND SAVE THESE INSTRUCTIONS. SE400E & SE800E Smoke Eliminator. TRION

Global Series Screw Air Compressors Life source of industries HP

INSTRUCTION & SERVICE MANUAL

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

Use. For 2-pipe fan coils

Transcription:

AC-046 Peltier-Thermoelectric Air Cooler Heats as well as cools (when used with heat & cool / bipolar controller) great for refrigeration of small containers and small heat loads. High density extruded heat sink and cold sink for high performance at low cost. High quality dual ball bearing fans. Keeps the air inside and outside of the enclosure separated, and 25 mm thick insulation can be used on the enclosure without impeding air flow to the cold sink. Maintains cabinet at NEMA 12 rating; production volumes can be customized for NEMA 4 (IP54 for the ambient-side fan). Powered by 12 VDC, its low power consumption makes it compatible with a wide range of our temperature controllers. Can be customized for production-sized order to meet your exact requirements. CE marked, RoHS compliant. AC-046 27-JULY-2018 Page 1 of 8

AC-046 Specifications Thermoelectric (TE) Power (typical) 1,3 : 24 VDC at 4.5 A Thermoelectric (TE) Power (maximum) 2,3 : 24 VDC at 5.4 A External (ambient) Fan Power: 24 VDC at 0.21 A Internal (enclosure) Fan Power: 24 VDC at 0.10 A External (ambient) Fan Noise: 44 dba Internal (enclosure) Fan Noise: 34 dba NEMA Rating: 12 Weight (kg): 2.5 Please review the product manual: Thermoelectric Cooling Assembly (TCA) Instruction Manual, FAQ s and related technical information, and ordering information posted on our web site before purchasing or using this product. Performance is based on unrestricted air flow to fans and from air-flow outlets. Do not operate if the ambient, enclosure air, heat sink, or cold sink temperatures exceed 70 C. Do not operate fan at air temperatures below -20 C or above 70 C. 1 Current, at steady-state, is rated at +25 C ambient, +25 C internal, maximum heat removal. At -10 C internal, the typical steady-state current is 4.5 A. 2 Current, at steady-state operation under-worst case conditions, is rated at -20 C ambient, +70 C internal, maximum heat removal. 3 Total current consumption is sum of TE current and Fan current. 177.8 127 25.4 23.5 RoHS Compliant Directive 2011/65/EU 104.6 80 127 A 3D PDF,.stp, and.sldprt solid models are also available from the website. Contact TE Technology for 3D solid models in other formats. 11.2 12.7 152.4 1 2 3 4 5 6 All dimensions in millimeters. Internal (enclosure) side shown in blue; External (ambient) side shown in red. 4X M5 x 0.8 THREADING TAPPED 9.7 DEEP INTERNAL (ENCLOSURE)-SIDE AIR FLOW INLET 25 DEEP HOLE with M3 x 0.5 THREADING TAPPED 9.7 DEEP for SENSOR MOUNTING 7.87 43.9 INTERNAL (ENCLOSURE)-SIDE AIR FLOW OUTLET INTERNAL (ENCLOSURE)-SIDE AIR FLOW OUTLET 96.5 65.6 3.05 EXTERNAL (AMBIENT)-SIDE AIR FLOW OUTLET Download manual www.tetech.com EXTERNAL (AMBIENT)-SIDE AIR FLOW OUTLET 79.4 48.5 38.35 EXTERNAL (AMBIENT)-SIDE AIR FLOW INLET THREAD BOSS FOR MOUNTING AC-046 27-JULY-2018 Page 2 of 8

70 AC-046 Cooling Performance Graph (removing heat from enclosure) Internal Air Temperature of Enclosure ( C) 60 50 40 30 20 10 0-10 50 C ambient 35 C ambient 25 C ambient -20 0 10 20 30 40 50 60 70 80 90 Heat Removed from Enclosure (watts) How to use the Performance Graph: 1. Select Performance Line The diagonal lines represent cooling performance at the indicated ambient air temperature (intake temperature on the ambient-side fan). If the cooler is to operate at a different ambient, then you must sketch in a new performance line. This can be drawn parallel to one of the existing lines, using the distance between the existing lines as a scale to properly locate the new line. 2. Select Enclosure Temperature Draw a horizontal line on the graph corresponding to the desired internal air temperature of the enclosure. Make the line intersect with the performance line corresponding to the ambient temperature at which the cooler is to operate. 3. Determine Cooling Capacity The maximum amount of heat that the cooler can remove from the enclosure is determined by the intersection point (determined in the previous step). The cooler will be able to maintain the desired enclosure temperature if the cooling capacity exceeds the heat load. If the heat load exceeds the cooling capacity then a higher capacity cooler will be needed. Example: You need to maintain the enclosure at 15 C while in a 25 C ambient. The cooler can remove a maximum of approximately 33 W of heat from the enclosure. If the heat load (internally generated heat plus the heat gain through insulation, solar, vapor condensation, etc.) in the enclosure exceeds this, you would need more coolers and/or a larger cooler. AC-046 27-JULY-2018 Page 3 of 8

70 AC-046 Heating Performance Graph (adding heat to enclosure) Internal Air Temperature of Enclosure ( C) 60 50 40 30 20 10 0-10 -20 25 C ambient 0 C ambient -20 C ambient 0 20 40 60 80 100 120 140 160 180 200 220 Heat Added to Enclosure (watts) How to use the Performance Graph: 1. Select Performance Line The diagonal lines represent heating performance at the indicated ambient air temperature (intake temperature on the ambient-side fan). If the cooler is to operate at a different ambient, then you must sketch in a new performance line. This can be drawn parallel to one of the existing lines, using the distance between the existing lines as a scale to properly locate the new line. Example: You need to maintain the enclosure at 30 C while in a -20 C ambient. The cooler can add a maximum of approximately 90 W of heat to the enclosure. If the heat dissipation from the enclosure exceeds this (plus anything else generating heat), you would need more coolers and/or a larger cooler. 2. Select Enclosure Temperature Draw a horizontal line on the graph corresponding to the desired internal air temperature of the enclosure. Make the line intersect with the performance line corresponding to the ambient temperature at which the cooler is to operate. 3. Determine Heating Capacity The maximum amount of heat that the cooler can add to the enclosure is determined by the intersection point (determined in previous step). If the heat added to the enclosure (including heat generated by equipment inside) is greater than the enclosure s heat loss, then the cooler will be able to heat to the desired temperature. A higher capacity cooler will be needed if the total heat added is less than the enclosure s heat loss. AC-046 27-JULY-2018 Page 4 of 8

Terminal Block Configuration for Continuous Operation at Full Power As-Shipped Configuration 1 of 2 1 REMOVE TERMINAL BLOCK COVER FOUR ELECTRICAL JUMPERS INSTALLED (ORIGINAL CONFIGURATION) 2 LOOSEN TWO SCREWS KEEP JUMPERS INSTALLED AC-046 27-JULY-2018 Page 5 of 8

Terminal Block Configuration for Continuous Operation at Full Power 2 of 2 3 Power supply (+) Red Wire to POSITION 6 Power supply (-) Black Wire to POSITION 1 4 INSTALL WIRES, TIGHTEN SCREWS TO 1.0 N-M, AND REPLACE COVER AC-046 27-JULY-2018 Page 6 of 8

Terminal Block Configuration for Operation with Temperature Controller 1 of 2 1 REMOVE TERMINAL BLOCK COVER FOUR ELECTRICAL JUMPERS INSTALLED (ORIGINAL CONFIGURATION) 2 LOOSEN SIX SCREWS REMOVE TWO ELECTRICAL JUMPERS FROM 2-3 AND 4-5 AC-046 27-JULY-2018 Page 7 of 8

Terminal Block Configuration for Operation with Temperature Controller 2 of 2 3 Power supply (+) Red Wire to POSITION 6 Temperature Controller (+) Red Wire to POSITION 4 Temperature Controller (-) Black Wire To POSITION 3 Power supply (-) Black Wire to POSITION 1 4 INSTALL WIRES, TIGHTEN SCREWS TO 1.0 N-M, AND REPLACE COVER AC-046 27-JULY-2018 Page 8 of 8