Installation & Operation Manual

Similar documents
Installation & Operation Manual

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE

INSTALLATION and OPERATION INSTRUCTIONS

Preparing the Cabinet

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS.

INSTALLATION and OPERATION INSTRUCTIONS

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

INSTALLATION and OPERATION INSTRUCTIONS

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

INSTALLATION and OPERATION INSTRUCTIONS

Operation Manual and Parts Directory

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINETS SELF CONTAINED AND REMOTE

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

CR24 INSTALLATION INSTRUCTIONS

Technical Manual and Replacement Parts List. f Real Freezers

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

CABINET PARTS For Model: KBFC42FTS03 (Stainless Steel)

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

Outdoor Beverage Center

INSTALLATION and OPERATION INSTRUCTIONS

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

User Manual / Installation Instructions

Operation Manual and Parts Directory

INSTALLATION AND OPERATION INSTRUCTIONS CONCESSIONAIRE PORTABLE DISPENSERS MODEL NOS.

CABINET PARTS For Model: KBLC36FTS06 (Stainless Steel)

Repair Parts List REFRIGERATOR MODEL NUMBER GT15B83V. When requesting service or ordering parts, always provide the following information:

Operation Manual and Parts Directory

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

CABINET PARTS For Model: KBLC36FTS04 (Stainless Steel)

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

RPI Industries, Inc.

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

Instruction Manual MODEL: GDUF Cu. Ft. Capacity 120V~, 60Hz, 115W

CABINET PARTS For Models: KBRS22KGWH0, KBRS22KGAL0, KBRS22KGBL0 (White) (Almond) (Black)

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) REV: LN PN

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

CABINET PARTS For Models: 7GS2SHEXPQ03, 7GS2SHEXPL03 (White) (Stainless VCM) REFRIGERATOR

Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT27

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

Outdoor Beverage Center

Freestanding Wine Cooler Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS for HOAM and VOAM Open Air Merchandisers

CABINET PARTS. REFRIGERATOR For Models: GR2SHKXKQ00, GR2SHKXKT00, GR2SHKXKB00, GR2SHKXKS00 (White) (Biscuit) (Black) (Stainless Steel)

CABINET PARTS. For Models: KBLC36FMS00 (Stainless Steel) 9 05 Litho In U.S.A. (kdj) Part No " BOTTOM MOUNT BUILT IN REFRIGERATOR

REF5-BB Undercounter Blood Bank Refrigerator

Installation and Operations Manual for HORIZONTAL DISPLAY MERCHANDISERS

CABINET PARTS For Model: KBLC36FMS02 (Stainless Steel)

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

RPI Industries, Inc.

CABINET PARTS REFRIGERATOR. For Models:ET21PKXGW03, ET21PKXGT03 (White) (Biscuit) Part No Litho In U.S.A. (cre) 1

REPAIR PARTS LIST. Model Nos (White On White) (Bisque) (Black) (Graphite) REFRIGERATOR

REPAIR PARTS LIST REFRIGERATOR

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)

CABINET PARTS. For Models: KSRT25CRWH00, KSRT25CRBT00, KSRT25CRBL00, KSRT25CRSS00 (White) (Biscuit) (Black) (Stainless Steel)

SERIES NAV S Display Merchandisers

CABINET PARTS For Models: ET18GKXBW00, ET18GKXBN00 (White) (Almond)

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Silver on Black) 106.

REFRIGERATOR Models:

CABINET PARTS For Models: ET21MMXJW01, ET21MMXJT01 (White) (Biscuit)

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

BULL INSTRUCTION MANUAL. Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

REF Series Undercounter Refrigerator

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

CABINET PARTS For Models: ET21GKXGW00, ET21GKXGN00 (White) (Almond)

Installation & Operation Manual. 24" C-Series Refrigerator Wine Reserve Beverage Center

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

CABINET PARTS For Model: IST (White)

FRIGIDAIRE COMMERCIAL FREEZER/REFRIGERATOR GLASS DOOR REFRIGERATOR TABLE OF CONTENTS

CABINET PARTS For Models: W8RXNGMWB02, W8RXNGMWS02, W8RXNGMWL02 (Black) (Stainless Steel) (Satina)

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

GS-2. Instruction Manual. G-Series Cooler

Operation Manual and Parts Directory

WHIRLPOOL REFRIGERADOR GS2SHGXLQ01

CABINET PARTS REFRIGERATOR. For Models: 8ET1FTKXKT00 (Biscuit) Litho In U.S.A. (mdg) 1. Part No

CABINET PARTS REFRIGERATOR

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) /17 Rev.

TOP MOUNT REFRIGERATOR MODELS: WRT106TFDW01 (White) WRT106TFDB01 (Black) WRT106TFDT01 (Biscuit)

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

3/15 Rev B

RPI Industries, Inc.

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

CABINET PARTS Printed In U.S.A. (mat) Part No. W Rev. B

Glass Door Merchandiser. Model RM-45-SD

Transcription:

Installation & Operation Manual Flat Top Bottle Cooler BC Series BC72 shown C US Form No. Z2295 Rev. 04.05.2018

JOB AREA ITEM NO. MODEL NO. BC24 SERIES BC36 SERIES BC48 SERIES BC24 shown BC72 shown BC48LT SERIES BC60 SERIES BC60LT SERIES BC72 SERIES BC72LT SERIES BC96 SERIES * BC36 Model Only C US MODEL NUMBERS BC24 BC36 BC48/BC48LT BC60/BC60LT BC72/BC72LT BC96 LENGTH (mm) 24 (610) 36 (915) 48 (1219) 60 (1524) 72 (1828) 96 (2438) INTERIOR CU. FT. (m 3 ) 3.75 (0.10) 7.83 (0.22) 11.68 (0.33) 15.53 (0.44) 19.38 (0.55) 27.08 (0.77) CASE CAPACITY (12 bottles) 5.5 9.75 17.2 21 28.3 41 CASE CAPACITY (12 cans) 7.0 16 25 30 36 58 CONDENSING UNIT H.P. 1/5 1/5 1/4 1/4 1/3 1/3 AMPS 3.2 3.0 5.2 7.0 6.9 7.6 SHIPPING WEIGHT Lbs. (kg.) 190 (86) 245 (111) 300 (136) 353 (160) 405 (184) 515 (235) INTERIOR EXTERIOR TEMPERATURE (Approx. factory settings) DOORS (Siding) ELECTRICAL PLUMBING INSULATION REFRIGERATION VENTILATION OPTIONAL ACCESSORIES All models have stainless steel walls and floor. Choice of black, stainless steel and all stainless. Black Option: Front and ends are black vinyl coated steel, back and bottom are galvanized. Stainless Steel Option: Front and ends are stainless steel, back and bottom are galvanized. All Stainless Option: Front, ends, back and bottom are all stainless steel. 38ºF/Standard Model. 30ºF Low-Temp Model Stainless steel top and bottom pans. Die cast handle. Option locks. 115V, 60Hz, 1 Phase. Furnished with 6 foot rubber plug-in cord (115V model only). Also available in 230V, 50Hz, 1 phase AC. No drain required. Condensate evaporates automatically. 2 inch foamed-in-place polyurethane insulation. R134a capillary tube/type with hermetric condensing unit. Pulls out for service and cleaning. 2 model is front vented, all other models require 2 clearance from wall on either left end or back of cabinet for proper air flow. Floor racks Casters Bottle opener and receiver Interior light Bin dividers Speed rails Wine temperature (specify red or white) Interior light kits Adjustable legs Roller basket shelving Door locks * Shown with Perlick optional is committed opener and to continuous receiver. improvement. Therefore, we reserve the right to change specifications without prior notice. Printed in USA 2

TABLE OF CONTENTS Cabinet Specifications... 2 Installing - Uncrating and Inspection... 4 - Plumbing... 4 - Electrical... 4 - Adjusting Partitions... 4 - Installing Casters and Legs... 4 - Placing the Cabinet... 4 - Sealing to the Floor... 4 Temperature Control... 5 Cleaning the Cabinet... 5 Wiring Diagrams... 7/8 Replacement Parts... 8/9 Introduction This manual has been prepared to assist you in the installation of your Bottle Cooler and to acquaint you with its operation and maintenance. We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, call Perlick at 1-800-777-7267 or your dealer who can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval. We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction. GENERAL INFORMATION SAFETY Warranty To register your product, visit our web site at www.perlick.com. Click on Commercial, then Service. Click on the link Warranty Registration Form. You must complete and submit this form or the installation date will revert back to the ship date. Please record the purchase date and the dealer s name, address and telephone number below. Model Number: Serial Number: Purchase Date: Dealer Name & Address Phone Number PLEASE READ all instructions completely before attempting to install or operate the unit. Take particular note of the DANGER, WARNING an CAUTION information in the manual. The information is important for the safe and efficient installation, operation and care of your Perlick unit. Indicates a hazard that WILL DANGER result in serious injury or death if precautions are not followed. Indicates a hazard MAY WARNING cause serious injury or death if precautions are not followed. Indicates a hazard where CAUTION minor injury or product damage may occur if precautions are not followed. IMPORTANT! Read and understand all information in this manual before attempting the installation. All plumbing and electrical work must be performed by a qualified technician and conform to all applicable state and local codes. Printed in USA 3

PREPARING THE CABINET - FLAT TOP BOTTLE COOLERS Uncrating and Inspection Remove all crating material. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit. Plumbing No plumbing connections are required. Condensate from the cooling coil automatically evaporated through a condensate pan located in the condensing unit section. Electrical The cabinet must be connected to a separately fused power source (see Electrical Specification Plate affixed to unit) in accordance with National and Local electrical codes. Do not attempt to operate CAUTION the equipment on any other power source than that listed on the Electrical Specification Plate. Adjustable Partitions & Shelving Perlick Bottle Coolers may be provided with adjustable partitions and shelving which will accommodate various bottle sizes. Remove bottles and cans from their cases before placing in cooler to ensure proper air flow. On 2 and 3 models keep air intake open for proper circulation. Placing the Cabinet To assure maximum performance, fresh air must be allowed to circulate through the machinery compartment. It is important to allow at least two inched of clearance at the back or left end of the cabinet. Do not place anything in front of the cabinet that would obstruct air flow at these grilles. Do not place the unit in an unventilated small room. Removing the factory CAUTION installed back clearance spacers without providing proper left side grill clearance for compressor air flow will void the warranty. Cabinet should be leveled. For sanitation purposed, it may be necessary to seal the base of the cabinet to the floor. This can be accomplished by laying a bead of silicone sealant along the base of the cabinet as shown by the figure below (figure 1). Cabinet Bead Silicon Sealer (RTV) Floor Installing Casters or Legs (optional) Attach casters or legs to the cabinet bottom in holes provided. Use the supplied 1/4-20 hex head self-tapping machine screws. If unit is tipped on its back for an extended period of time, wait 24 hours after unit is uprighted to plug the unit in. Figure 1. Sealing Cabinet to Floor Printed in USA 4

HOW TO OPERATE - FLAT TOP BOTTLE COOLERS Temperature Control An adjustable temperature control is located inside the Bottle Cooler on the evaporator fan panel assembly. It is factory set at approximately 38 F for standard refrigeration and approximately 30 F for low temperature models. Make adjustments as detailed below to attain the desired temperature. NOTE: A temperature setting that is too low will not allow enough condensing unit off time to maintain a frost-free coil. Colder Temperatures: Turn the adjusting screw clockwise (to the right) Warmer Temperatures: Turn the adjusting screw counterclockwise (to the left). Temperature Control OFF : Turn the adjusting screw completely counterclockwise to the O position until a click is noted. The condenser fan motor turns off and on with compressor. The evaporator fan motor runs continuously. Cleaning the Condenser The condenser (located behind the from grille) should be inspected every 30 days, and cleaned, if necessary. Failure to keep the condenser clean will cause a loss in condensing unit efficiency, or compressor failure. Cleaning the Doors Doors should be periodically removed from the cabinet and inspected for a buildup of foreign materials, such as syrups, beer, etc. Buildups on the underside of the doors, along with the cabinet breaker strips on which they ride, will cause them to bind, and therefore, not function as designed. If dirty, these surfaces should be cleaned with a mild detergent and water and then coated with a silicone lubricating material. Aerosol silicone sprays can be obtained locally at most hardware or automotive stores. To remove doors: With door closed, lift it upward by its handle and slide forward until doors clears the cabinet top. Use the reverse procedure to reinstall the doors. Cleaning the Cabinets Use a damp cloth with a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Do not allow cleaning agents or large amounts of water to go down the drain. Use an acceptable stainless steel polish to clean all stainless steel surfaces. Never use steel wool or scouring pads to clean stainless steel. Avoiding Stainless Steel Corrosion Corrosion can be prevented by following product cautions, cleaning instructions and avoiding use of certain chemicals or objects which will cause stainless steel corrosion. STAINLESS STEEL ENEMY Steel wool or steel scouring pads Cherry/Orange/Olive juice Chlorine Bleach Sharp Objects Printed in USA 5

WIRING DIAGRAM - FLAT TOP BOTTLE COOLERS Printed in USA 6

WIRING DIAGRAM - LOW-TEMP BOTTLE COOLERS Printed in USA 7

REPLACEMENT PARTS - FLAT TOP BOTTLE COOLERS Printed in USA 8

REPLACEMENT PARTS - FLAT TOP BOTTLE COOLERS MODEL NOS. BC24 BC36 BC48/ BC48LT BC60/ BC60LT Item Description Part Numbers BC72/ BC72LT 1 Complete condensing unit C22648 C22648 C22647 C22646 C22646 C22646 2 Replacement compressor, R134a 513307046 513307046 513200314UA2 513200003 513200003 513200003 Condensing unit fan motor assy. 515315009 515315009 515315009 515315009 515315009 515315009 Terminal Board 519100088 519100088 519100088 519100088 519100088 519100088 Overload Protector 513634530 513634530 US-PB10HBX1 US-PB12HBX1 US-PB12HBX1 US-PB12HBX1 Relay 513514069 513514069 US-PB10HBX1 US-PB12HBX1 US-PB12HBX1 US-PB12HBX1 Start capacitor N/A N/A US-PB10HBX1 US-PB12HBX1 US-PB12HBX1 US-PB12HBX1 3 Condensate pan 64537 64626-1 64626-1 64626-1 64626-1 64626-1 4 Evaporator fan motor(s) C15239A C15239A C15239A C15239A C15239A C15239A 5 Evaporator fan motor bracket 65671-1 65671-1 60988-1 60988-1 60988-1 60988-1 6 Evaporator fan motor blade 63461 63461 57699 57699 57699 57699 7 Evaporator fan guard 65666 65666 65557 65557 65557 65557 8 Evaporator coil 64785-1EP C17511-1EP C17511-1EP C17511-2EP C17511-2EP C17511-2EP 9 Temperature control 61283 61283 61283 61283 61283 61283 10 Bottle opener C6713-1 C6713-1 C6713-1 C6713-1 C6713-1 C6713-1 11 Bottle cap receiver C17332SS C17332SS C17332SS C17332SS C17332SS C17332SS 12 Front grille 66498-3A 65662-1A 65662-A1 65662-1A 65662-1A 65662-1A 13 Rear grille/panel 66498-1 65662-3 65662-3 65662-3 65662-3 65662-3 14 Top assembly RT-SL2 RT-SL2 RT-SL2 RT-SL2 RT-SL2 RT-SL2 15 Top wiper gasket 63671-24 63671-36 63671-48 63671-60 63671-72 63671-96 16 Door assembly RD-SL2 RD-SL2 RD-SL2 RD-SL2 RD-SL2 RD-SL2 17 Lock assembly 63940 63940 63940 63940 63940 63940 18 Vertical partition 65503 66441 66441 66441 66441 66441 19 Roller basket N/A 66442-1 66442-1 66442-1 66442-1 66442-1 20 Wide shelf N/A 64811-1 64811-1 64811-1 64811-1 64811-1 21 Narrow shelf 64809-1 64809-1 64809-1 64809-1 64809-1 64809-1 22 Bottom floor rack (wide) 64814-1 64814-1 64814-1 64814-1 64814-1 64814-1 23 Bottom floor rack (narrow) N/A N/A 64815-1 64815-1 64815-1 N/A 24 Shalf bracket 65653-24 65653-36 65653-48 65653-60 65653-72 65653-96 25 Door handle 63931 63931 63931 63931 63931 63931 26 Light Bulb C15046 C15046 C15046 C15046 C15046 C15046 27 Light socket 63484 63484 63484 63484 63484 63484 28 Evaporator drain pan 65670-24 65670-36 65526-1SL 65526-2SL 65526-2SL 65526-2SL BC96 ITEMS NOT SHOWN Wire harness, main 65043-1 65043-1 65044-1 65044-1 65044-1 65044-1 Suction line/cup tube heat exchanger with drier 65072 65072 65073 65075 65074 65220 Mullion assembly N/A N/A 66551 66551 66551 66551 Refrigerant charge (oz. R134a) 6.0 8.5 9.0 9.0 9.0 9.0 Printed in USA 9

Printed in USA 10

Printed in USA 11

8300 West Good Hope Road Milwaukee, WI 53223 Perlick is committed Toll Free to continuous 800.558.5592 improvement. Therefore, Fax we 414.353.7069 reserve the right to change www.perlick.com specifications without prior notice. Printed in USA 12