ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

Similar documents
Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

2012 International Fire Code Errata (Portions of text and tables not shown are unaffected by the errata)

SEMICONDUCTOR FABRICATION FACILITIES

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Laboratories and Hazardous Materials. Company Overview

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

BUILDING/FIRE CODE REFERENCES 2006 EDITION

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

TABLE OF CONTENTS. Part I Administrative... 1 CHAPTER 1 SCOPE AND ADMINISTRATION... 1

Above Ground Fuel Tank Requirements

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Virginia Statewide Fire Prevention Code

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

Recommended Amendments to the 2003 International Fire Code North Central Texas Council of Governments region

Correctly Classifying and Determining Fire Protection Requirements for High- Hazard Group H Occupancies in New York State (2010 codes)

Report on First Revisions with Statement June 2014 NFPA 101

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

Level I Chapter 1 Worksheet

Defend In Place 2012 IFC Overview of Institutional Occupancies

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

2015 International Fire Code

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

***DRAFT - NOT FOR FILING***

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT

*HB0217* H.B. 217 H.B STATE FIRE CODE ACT AMENDMENTS. LEGISLATIVE GENERAL COUNSEL 6 Approved for Filing: C.R. Gilbert :11 PM 6

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

FIRE PROTECTION SYSTEMS

APPENDIX A FEES SECTION FC A01 CERTIFICATES A01.1

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

PART 2. Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Local Amendments 2009 International Fire Code

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

FIRE SERVICE FEATURES

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005

Iowa (2) Delete section and insert in lieu thereof the following new section:

The Cannabis Industry: Fire Department Requirements

Agency for Health Care Administration

Effective Use of the International Fire Code

ORDINANCE NO

The general safety requirements in the IFC were developed to. General Precautions against Fire CHAPTER

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Code Breaking Barrel Storage

Denver Fire Department Fire Prevention Division

CHAPTER 7 ALTERATIONS LEVEL

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

1301: Fire protection systems.

Report on First Revisions with Statement June 2014 NFPA 101

IBC Committee Responsibility Matrix January 2017

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Amendment A International Fire Code

REVISION RECORD FOR THE STATE OF CALIFORNIA SUPPLEMENT

APPENDIX A International Building Code Amendments

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

INDEX 2006 VIRGINIA STATEWIDE FIRE PREVENTION CODE INDEX-1

INDEX 2006 INTERNATIONAL FIRE CODE 411

Plan Submittal Checklist

Committee on NFPA 51A

General Safety Requirements

The general safety requirements in the IFC were developed to. General Precautions Against Fire CHAPTER

INTRODUCTION. Page 1 of 5

2008 NYC Fire Code. New Laboratory Standards. Operational & Maintenance Provisions effective July 2008

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

Residential-based Care Facility R-4 Guideline

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

First Revision No NFPA [ Section No ]

ORDINANCE NO The Council of the City of Palo Alto does ORDAIN as follows:

South Davis Metro Fire Agency

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

Mt. Crested Butte Code

ARTICLE 25. FUEL GAS CODE

TABLE OF CONTENTS. Part I Administrative

FIRE PROTECTION SYSTEMS

Drexel Heights Fire District 2012 International Fire Code Amendments

1301: Fire protection systems. (A) Section 901 General

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Safety Tips for the Office

2006 INTERNATIONAL FIRE CODE WITH PHOENIX AMENDMENTS

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

Tire Storage. Michigan Fire Inspectors Society Fall Conference

Agency for Health Care Administration

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

Code Technology Committee Area of Study Balanced Fire Protection Roof Vents

International Fire Code

Residential Based Care Facility Guidelines

ICC CODE CORNER 2012 IFC Code & Commentary

FIRE PREVENTION CODE

Transcription:

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE Fourth Printing, January 2002 Updated March 29, 2002 Table 2306.2 General Fire Protection and Life Safety Requirements In column 2 (Size of High Piled Storage Area), in the last cell opposite Commodity Class I- IV, the text should read: Greater than 500,000 g Third Printing, July 2001 (See also Fourth Printing, January 2002) Section 803.2.1, Exception 2. Revise 3 rd line to read provided it is not less than 20 pounds.... Section 803.7.1 Upholstered furniture classification. Change reference NFPA 261 to NFPA 260. Section 1003.3.1 Doors. Revise 2 nd line of the 2 nd paragraph to read from the adjacent construction and finishes such that the doors are easily recognizable as doors. Section 3904.1.8 Storage arrangement. Change the table reference in the text from 3904.1.2 to 3904.2.4. Table 4004.1.2 Oxidizer Liquids and Solids Separation of Detached Buildings and Outdoor Storage Areas to Exposures. For Class 4 Oxidizers, in the WEIGHT column, revise the 4 th line to read: 1,001 to 3,000. Section 4102.1 Definition. In the definition of PYROPHORIC, change the temperature to 130 F (54 C). Appendix D Figure D103.1 95 Diameter Cul-de-sac Change 95' to 96' in the figure and title. Appendix D Figure D103.1 Minimum Clearance Around a Fire Hydrant Change 28' to 26'. 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 1 of 10

Section 906.1 Where required. Revise to read as follows: Second Printing, November 2000 (See also Third Printing, July 2001) 1. In all Group A, B, E, F, H, I, M, R-1, R-2, R-4, and S occupancies. Exception: In all Group A, B, and E occupancies equipped throughout with quick response sprinklers, fire extinguishers shall be required only in special hazard areas. 2. Within 30 feet (9144 mm) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed. 4. On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 1414.1. 5. Where required by the sections indicated in Table 906.1. 6. Special-hazard areas, including but not limited to laboratories, computer rooms, and generator rooms where required by the code official. Section 1003.3.4.1 Slope. Revise 2 nd line to read Group A shall comply with Section 1008.9. Section 1004.2.4.2 Exterior egress balcony increase. Revise 6 th line to read with Section 1004.3.3. The length of such balcony shall... Section 1004.3.1.3 Seating at tables. Revise the 3 rd line to read measured from the back of the seat. Section 1008.7 Assembly aisles required. Revise 6 th line to read comply with Section 1004.3.1.3. Section 1008.10 Seat stability. Delete the 2 nd sentence in its entirely. Section 2306.10 Portable Fire Extinguishers. Revise second line to read extinguishers shall be provided in accordance with Section 906". Table 2703.1.1(2) Maximum Allowable Quantity Per Control Area of Hazardous Material Posing a Health Hazard a,b,c,j Revise the row for Corrosive, under Storage/Gas cubic feet and Use-Closed System/Gas cubic feet, the entry should read: 810 f,g Table 3304.5.2(1) Application of Separation Distance Table a. Revise the 2 nd column heading cell to refer to the American Table...Materials 3304.5.2(2)... Revise the 3 rd column heading cell to refer to the Table of...explosives 3304.5.2(3)... 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 2 of 10

Section 3404.4.3 Spill control and secondary containment. Revise the third line to read containment in accordance with Section 3403.4". Section 3405.2.4 Class I and II liquids. Revise to read as follows: 3405.2.4 Class I and II liquids. Class I and II liquids shall be transferred by one of the following methods. Exception: Liquids in containers not exceeding 5.3-gallon (20 L) capacity. 1. From safety cans complying with UL 30. 2. Through an approved closed piping system. 3. From containers or tanks by an approved pump taking suction through an opening in the top of the container or tank. 4. For Class I-B, I-C, II and III liquids, from containers or tanks by gravity through an approved self-closing or automatic-closing valve when the container or tank and dispensing operations are provided with spill control and secondary containment in accordance with Section 3403.4. Class I-A liquids shall not be dispensed by gravity from tanks. 5. Approved engineered liquid transfer systems. Section 3803.2.2 Industrial vehicles and floor maintenance machines. Revise the 3 rd line to read...machines shall comply with NFPA 58, Sections 8-3 and 8-4. First Printing, December 1999 (See also Second Printing, November 2000) Section 105.1.2 Construction permit. Delete 105.6 and replace with 105.7" in Item 2 Section 105.6.17 Flammable and combustible liquids. Delete (see Section 3501.1.2) and (see Section 3503.6) as they appear in Item 1. Section 202.1/OCCUPANCY CLASSIFICATION Delete the [B] preceding the heading OCCUPANCY CLASSIFICATION Section 202.1/ Definition of OCCUPANCY CLASSIFICATION/Hazardous Group H Delete the [B] preceding the definition Hazardous Group H title Delete the phrase through 307.7(4) and replace it with and 307.7(2) in the next to last line of the definition. 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 3 of 10

Section 202.1/Definition of OCCUPANCY CLASSIFICATION/Group H-3 structures. Delete Aerosols, Level 2 and Level 3", which begins the listing following the first paragraph. Section 202.1/Definition of OCCUPANCY CLASSIFICATION/Miscellaneous Group U. Insert [B] preceding the Miscellaneous Group U title. Section 202.1 Definition of REGISTERED DESIGN PROFESSIONAL Insert [B] preceding the definition title. Section 202.1 Definition of TIRES, BULK STORAGE OF Delete the definition text and replace with See Section 902.1". Section 313.1 Vehicle storage. Revise Exception 1, line 3 to read: in accordance with Section 8-4 of NFPA 58 shall not Section 404.2 Where required. Revise item 9, line 1 to read: Covered malls exceeding 50,000 square feet (4645 m 2 ) Table 405.2 Fire and Evacuation Drill Frequency and Participation. Delete footnote a reference in the title block FREQUENCY Section 507.2.2 Interior access to shaftways. Delete from the outside of the building in the last line. Section 603.5.2 Heating appliance installation. Revise the 4 th line to read: International Mechanical Code, the International Fuel Gas Code and the ICC Electrical Section 603.6.1 Masonry chimneys. Revise the 5 th line to read: dangerous, shall be repaired or relined... Section 604.2.10 Highly toxic and toxic materials. Delete 3704.2.9 and 3704.3.7" and replace with 3704.2.2.8 and 3704.3.2.6" in the third line. Section 604.2.12 Pyrophoric materials. Delete pyrophoric materials and replace with silane gas in the second line. Section 606.8 Refrigerant detector. Delete 1106.8" and replace with 1106.3" in the Exception. Section 901.4.2 Nonrequired fire protection systems. Delete permitted and replace with allowed in the third line. Section 901.5 Installation acceptance testing. In the fourth line, change main to mains 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 4 of 10

Section 902.1 Definitions. Add new definition: TIRES, BULK STORAGE OF. Storage of tires where the area available for storage exceeds 20,000 cubic feet (566 m 3 ). Section 903.2.6.1 High-piled storage. Change the chapter reference in line two from 24" to 23" Section 903.2.9 Group R-4. Revise Exception as follows: Group I-1 R-4 facilities. Section 903.2.10 Group S-1. Add new sub-section to read: 903.2.10.2 Bulk storage of tires. Buildings and structures where the area for the storage of tires exceeds 20,000 cubic feet (566 m 3 ) shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. Table 903.2.15 Additional Required Fire-Extinguishing Systems. In the SECTION column, delete 3704.2.7" and replace with 3704.2.2.6" for gas rooms for toxic and highly toxic gases and delete 3704.3.9" and replace with 3704.3.3" for outdoor storage of toxic and highly toxic gases. Section 903.4 Sprinkler system monitoring and alarms. Add NFPA before 13R in Exception 3. Section 905.10 During construction. Delete 1512" and replace with 1412" in the last line Section 907.2.1 Group A. Add the word system after fire alarm in the next to last line of the section Section 907.2.13.2 Atriums connecting more than two stories. Change connect to connects in the third line Section 907.2.23 Battery rooms. Delete 100 gallons (378.5 L)" and replace with 50 gallons (189 L) in the fourth line. Section 909.1 Scope and purpose. Revise the third line to read for new buildings or portions thereof by provisions of the International Building Code or this code. Section 909.2 General design requirements. Revise the second line to read: structures, or parts thereof required by the International Building Code or this code to have... Section 910.2.3 Design and installation. Revise the third line to read rack storage in any occupancy group when required by. 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 5 of 10

Section 1003.2.10.5 Power source. Delete enure and replace with ensure in the second line. Section 1003.2.12.2 Opening limitations. Delete the second sentence ( See Section 1003.2.12.3 for climbing limitations. ) in its entirety. Section 1003.2.13.1.1 Buildings with four or more stories. Revise Exception 2 to read as follows: In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2 the elevator shall not be required on floors provided with a ramp conforming to the provisions of Section 1003.3.4. Section 1003.3.1.2 Door swing. Revise Exception 3 by deleting the phrase or Group R-4 occupancies in the third line. Section 1003.3.3.3 Stair treads and risers. Revise Exception 4 in the first line to read: Aisle stairs in assembly seating Revise Exception 6 to read: The replacement of existing stairways in accordance with Section 1010.10." Section 1010.16.4 Access. Delete 1003.2.3.1" and replace with 1003.2.3" in the fourth line. Table 1804.2.1 Quantity Limits for Hazardous Materials in a Single Fabrication Area in Group H-5 a On the line for Flammable Gas-Gaseous in the column labeled GAS, revise the reference from Note b to Note c. Section 2206.2.3 Above-ground tanks located outside, above grade. Revise line 3 to read: of Class I, II or IIIA liquid motor fuels except as provided. Revise ITEM 1, line 2 to read: storage of Class I liquids shall be listed and labeled Split ITEM 2 and make it two separate ITEMS as follows: 2. Above-ground tanks...with Table 2206.2.3. 3. Tanks containing...(30 480 mm). Renumber ITEM 3 as Item 4. Section 2206.6.2 Piping, valves, fittings and ancillary equipment for above-ground tanks for Class I, II and IIA liquids. Revise line 2 of the section title to read: for above-ground tanks for Class I, II and IIIA liquids. Section 2208.8 Discharge of CNG from motor vehicle fuel storage. Revise the 5 th line to read: accordance with Sections 2208.8.1 through 2208.8.1.2.6. 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 6 of 10

Section 2301.1 Scope. Revise Item 6 as follows: 2301.1 Scope. High-piled combustible storage shall be in accordance with this chapter. In addition to the requirements of this chapter, the following material-specific requirements shall apply: 1. through 4 (No change; #5 shown for clarity) 5. Storage of combustible fibers shall be in accordance with Chapter 29. Storage of miscellaneous combustible material shall be in accordance with Chapter 3. Section 2702.1 Definition of HAZARDOUS MATERIALS In the third line of the definition, change the chapter reference from 28" to 27". Section 2702.1 Definition of MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA. Revise as follows: Add area after allowable quantity per control in the second sentence, 5 th line. Delete the last sentence: The term maximum allowable quantity per control area has the same meaning as the term exempt amount found in the International Building Code. Revise the line for Oxidizer Class 4 in the Use-Open Systems--Liquid gallons column to read: (0.25) g Revise the line for Organic Peroxide in the Class column by deleting the U and replacing it with UD In the COMBUSTIBLE LIQUID- Class IIIB, ORGANIC PEROXIDE- Classes IV & V, UNSTABLE (REACTIVE)- Class 1 and WATER REACTIVE- Class 1 rows in the column labeled GROUP WHEN THE MAXIMUM ALLOWABLE QUANTITY IS EXCEEDED, insert N/A In the ORGANIC PEROXIDE row in the column labeled STORAGE-Solid Pounds (cubic feet), in the line for UD, the entry should read 1 eg. 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 7 of 10

In the COMBUSTIBLE LIQUID row in the column labeled GROUP WHEN THE MAXIMUM ALLOWABLE QUANTITY IS EXCEEDED...move the entries in the cell UP one line so that Class II = H-2 or H-3 and Class III = H-2 or H-3. [Class IIIB has no Group]. In the WATER REACTIVE row in the column labeled GROUP WHEN THE MAXIMUM ALLOWABLE QUANTITY IS EXCEEDED...move the entries in the cell UP one line so that Class 3 = H-2; Class 2 = H-3. [Class 1 has no Group]. In the ORGANIC PEROXIDE row in the column labeled GROUP WHEN THE MAXIMUM ALLOWABLE QUANTITY IS EXCEEDED...move all entries in the cell UP one line so that UD = H-1; Class I = H-2; Class II = H-3 and Class III = H-3. [Class IV and V have no Group]. In the UNSTABLE REACTIVE row in the column labeled GROUP WHEN THE MAXIMUM ALLOWABLE QUANTITY IS EXCEEDED...move the entries in the cell UP one line so that Class 4 = H-1; Class 3 = H-1 or H-2; Class 2 = H-3. [Class 1 has no Group]. Revise the item for ORGANIC PEROXIDE in the 12 th row, under class in the second column to read Ud UD. Table 2703.1.1(2) Maximum Allowable Quantity Per Control Area of Hazardous Material Posing a Health Hazard a,b,c,j Revise the row for Highly Toxic in the column headed Use - Open Systems/Liquid Gallons to read: (3) i Section 2703.11.3.6 Container size. (Fix typo.) Revise the section title by deleting 2704.11.3.6" and replacing it with 2703.11.3.6" Table 2704.2.2 Required Secondary Containment Hazardous Material Solids and Liquids Storage. Revise the row for Cryogenic Fluids in the column headed Outdoor Storage/Liquid by changing the reference to read See Chapter 32". 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 8 of 10

Table 2704.14 Required Detached Storage. Revise the row for Oxidizer, liquids and solids in the column headed Class by changing Class 4" to Class 2". Section 2705.4.2 Quantities not exceeding the maximum allowable quantity per control area. Add allowable between maximum quantity in the 8 th line. Table 2705.2.1.4 Required Secondary Containment Hazardous Material Solids and Liquids Use. Revise all references to Chapter 33" to read Chapter 32" Revise all references to Chapter 34" to read Chapter 33" Revise all references to Chapter 35" to read Chapter 34" Section 2904.2 Storage of 100 cubic feet and less. Revise section title to read: Storage of 100 cubic feet or less. Section 3203.4.2 Identification of contents. Revise the 4 th line to read: placarded in accordance with Sections 2703.5 and 2703.6". Section 3304.5.3 Special requirements for Type 3 magazines. Revise the section text to read: Type 3 magazines shall comply with Sections 3304.5.3.1 through 3304.5.3.3." Section 3403.2.9.1.2 Foam fire protection system installation. (Fix typo) Revise Section number before title to read 3404.2.9.1.2" Section 3404.2.10.5 Equipment, controls and piping in diked areas. Revise Exception 1 in the third line to read: protected by intermediate diking, berms, drainage Section 3406.6 Tank vehicles and vehicle operation. Delete 3406.6.5" in the last line and replace with 3406.6.4" Section 3703.1 Indoor storage and use. Delete 3703.4.2.1" in the last line and replace with 3703.1.5.3" Section 3703.1.2 Quantities exceeding the maximum allowable quantity per control area. Revise the last line to read as follows: Sections 3701, 3703.1.3 through 3703.1.5.3 and Chapter 27. Section 3704.2 Indoor storage and use. Revise the last line to read: Sections 3704.2.1 through 3704.2.2.10.3." 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 9 of 10

Chapter 45 Referenced Standards ANSI: < A13.1 96-Delete 2702.3.2.2.1" and replace with 2703.2.2.1" API: < 2028 91-Delete 3404.2.7.2.3" and replace with 3404.2.7.3" ICC: < EC 2000-Delete 3704.2.9" and replace with 3704.2.2.8" < IMC 2000-Delete 1004.3.3.5" and replace with 1004.3.2.4" Delete 3703.2" and replace with 3703.1.3" Delete 3703.5.4" and replace with 3703.2.3.2" Delete 3704.2.8" and replace with 3704.2.2.7" Appendix B Section B102.1 Add the word Definitions to the title, after B102.1" Appendix D Table D103.4 Requirements for Dead-End Fire Apparatus Access Roads Revise the 3 rd cell in the column headed Length to read 151-500". Appendix D D104.1 Building exceeding three stories/30 feet in height. Revise the title to read: Buildings exceeding three stories or 30 feet in height." 2000 IFC Errata (Web Posting Date: March 29, 2002) Page 10 of 10