DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Similar documents
DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

INSTALLATION INSTRUCTIONS

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia

SPLIT SYSTEM AIR CONDITIONER

INSTALLATION INSTRUCTIONS

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO.

TEST RUN SERVICE MANUAL

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

MULTI-SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

DESIGN & TECHNICAL MANUAL

Installation Instructions

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

INSTALLATION INSTRUCTIONS

DESIGN & TECHNICAL MANUAL

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Destination Europe WARNING

TECHNICAL & SERVICE MANUAL WIRED REMOTE CONTROLLER STK-RCS-7TWSUA FILE NO. Product Code No Model No. STK-RCS-7TWSUA

Installation Instructions

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

Wall Mounted Split Systems

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

YC ON-OFF SERIES. Service Manual

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

SERVICE MANUAL CLASSIC 10 SERIAL NUMBER FROM FEBRUARY 2011 (0211) TO PRESENT. DocID: 00G00089E

TECHNICAL & SERVICE MANUAL

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

INVERTER SPLIT SYSTEM AIR CONDITIONER

2-WAY ECO-i MULTI SYSTEM

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

INSTALLATION INSTRUCTIONS R 410A

MAC N-407 Air-Cooled Chiller

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Part 3 Troubleshooting

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA-

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

MAC-120HE-03 Air-Cooled Chiller

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

TABLE OF CONTENTS. Air Conditioner

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

HEAT PUMP INSTALLATION MANUAL

DESIGN & TECHNICAL MANUAL

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Air Conditioner CONTENTS

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Installation Instructions

DESIGN & TECHNICAL MANUAL

Transcription:

TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No. CLM97 CLM7 CLM7 Product Code No. 8 0 8 0 8 0 CLM97 < Applicable Indoor Units > all mounted type KMS077 KMS097 KMS7 KMS87 KMS7 NOTE CLM7 For details about the combination, refer to "Unit Combination Table" in the Appendix of this manual. CLM7 IMPORTANT These air conditioners employ new refrigerant R0A. Pay special attention when servicing the unit. REFERENCE NO. SM700680-0

Important! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. For safe installation and trouble-free operation, you must: Carefully read this instruction booklet before beginning. Follow each installation or repair step exactly as shown. Observe all local, state, and national electrical codes. Pay close attention to all warning and caution notices given in this manual. This symbol refers to a hazard or ARNING unsafe practice which can result in severe personal injury or death. CAUTION SPECIAL PRECAUTIONS ARNING hen iring This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. If Necessary, Get Help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions. In Case of Improper Installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document. ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO IRE THIS SYSTEM. Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked. Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death. Ground the unit following local electrical codes. Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard. Install a protective leakage breaker depending on the installation location (especially a damp or humid location). If a leakage breaker is not installed, electric shock can occur. hen Transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers. hen Installing In a Ceiling or all Make sure the ceiling/wall is strong enough to hold the unit s weight. It may be necessary to construct a strong wood or metal frame to provide added support. In a Room Properly insulate any tubing run inside a room to prevent "sweating" that can cause dripping and water damage to walls and floors. In Moist or Uneven Locations Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration. In an Area with High inds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle. In a Snowy Area (for Heat Pump-type Systems) Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents. hen Connecting Refrigerant Tubing Use the flare method for connecting tubing. Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection. Check carefully for leaks before starting the test run. hen Servicing Turn the power off at the main power box (mains) before opening the unit to check or repair electrical parts and wiring. Keep your fingers and clothing away from any moving parts. Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced. Others CAUTION Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas. Confirm upon completing installation that no refrigerant gas is leaking. If escaped gas comes in contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas.

Table of Contents APPLICABLE INDOOR UNITS.... OPERATING RANGE... Page. SPECIFICATIONS -. Unit Specifications -. Major Component Specifications -. Other Component Specifications.......... DIMENSIONAL DATA.... REFRIGERANT FLO DIAGRAM -. Refrigerant Flow Diagram.... PERFORMANCE DATA -. Temperature Charts... -. Cooling Capacity... -. Cooling Capacity (Low Ambient)... 6 6 9 6 9 6. ELECTRICAL DATA 6-. Electric iring Diagrams... 7. FUNCTIONS 7-. Explanation of Functions... 7-. Protective Functions... 8. TROUBLESHOOTING 8-. Precautions before Performing Inspection or Repair... 8-. Trouble Diagnosis by Error Monitop Lamps... 8-. Checking the Outdoor System... 8-. Trouble Diagnosis of Each Part... 8-. Trouble Diagnosis of Fan Motor... 9. REFRIGERANT R0A: SPECIAL PRECAUTIONS HEN SERVICING UNIT 9-. Characteristics of New Refrigerant R0A... 9-. Checklist before Servicing... 9-. Tools Specifically for R0A... 9-. Tubing Installation Procedures... 9-. In Case of Compressor Malfunction... 9-6. 9-7. 9-8. In Case Refrigerant is Leaking Charging Additional Refrigerant Retro-Fitting Existing Systems......... APPENDIX A INSTALLATION INSTRUCTIONS... APPENDIX B UNIT COMBINATION TABLES... 9 8 9 60 6 6 6 6 6 6 A- A-

APPLICABLE INDOOR UNITS Multi-Outdoor Unit Indoor Unit KMS077 KMS097 KMS7 KMS87 KMS7 -Room CLM97 YES YES YES YES NO -Room CLM7 YES YES YES YES YES -Room CLM7 YES YES YES YES YES NOTE The table lists the wall-mounted type of indoor units as representative models.

. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 9 F D.B. / 7 F.B. Cooling Minimum 67 F D.B. / 7 F.B. * F D.B.: hen combined with KMS87 or KMS7 F D.B.: hen combined with KMS077, KMS097 or KMS7 F D.B. *

. SPECIFICATIONS -. Unit Specifications Outdoor Unit CLM97 Indoor Unit KMS097 Type Number of Connectable Indoor Units Number of Operatable Indoor Units Voltage Rating -Room Multi Outdoor Unit 0V Single-Phase 60Hz < 0V > Performance Total Capacity Sensible Capacity Latent Capacity Air Circulation (High) BTU/h k BTU/h BTU/h ft /min (m /h) 9,700.80 Cooling ( 9,800 to 9,700 ) (.90 to.80 ) 6,800,900,707 (,900) Electrical Rating Available Voltage Range V 87 to Running Amperes Power Input A 7.0,70 Power Factor % 98 SEER BTU/h Compressor Locked Rotor Amperes A.0 Fuse or Circuit Breaker Capacity A 0 Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi and multi-steps) Compressor Refrigerant / Amount charged at shipment Ib. (g) DC Twin Rotary (Inverter) R0A / 6.7 (,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool db-a 0 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft. (m) 8 () Refrigerant Narrow tube inch (mm) / (6.) Tube Diameter ide tube inch (mm) /8 (9.) Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m ) Cooling 9-/8-7/6-9/ (70 900 0) -7/ 0-/8 6-/ (860,0 ) 8.9 7.7.7 (6.0) (67.0) (0.6) DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMS097 units Outdoor Unit : CLM97 unit. Rating conditions are: Cooling : Indoor air temp. 80 F D.B./ 67 F.B. Outdoor air temp. 9 F D.B./ 7 F.B. 6

Outdoor Unit CLM97 Indoor Unit KMS097 Type Number of Connectable Indoor Units Number of Operatable Indoor Units Voltage Rating -Room Multi Outdoor Unit 08V Single-Phase 60Hz < 08V > Performance Total Capacity Sensible Capacity Latent Capacity Air Circulation (High) BTU/h k BTU/h BTU/h ft /min (m /h) 9,700.80 Cooling ( 9,800 to 9,700 ) (.90 to.80 ) 6,800,900,707 (,900) Electrical Rating Available Voltage Range V 87 to Running Amperes Power Input A 7.7,70 Power Factor % 98 SEER BTU/h Compressor Locked Rotor Amperes A.0 Fuse or Circuit Breaker Capacity A 0 Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi and multi-steps) Compressor Refrigerant / Amount charged at shipment Ib. (g) DC Twin Rotary (Inverter) R0A / 6.7 (,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool db-a 0 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft. (m) 8 () Refrigerant Narrow tube inch (mm) / (6.) Tube Diameter ide tube inch (mm) /8 (9.) Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m ) Cooling 9-/8-7/6-9/ (70 900 0) -7/ 0-/8 6-/ (860,0 ) 8.9 7.7.7 (6.0) (67.0) (0.6) DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMS097 units Outdoor Unit : CLM97 unit. Rating conditions are: Cooling : Indoor air temp. 80 F D.B./ 67 F.B. Outdoor air temp. 9 F D.B./ 7 F.B. 7

Outdoor Unit CLM7 Indoor Unit KMS097 Type Number of Connectable Indoor Units Number of Operatable Indoor Units Voltage Rating -Room Multi Outdoor Unit 0V Single-Phase 60Hz < 0V > Performance Total Capacity Sensible Capacity Latent Capacity Air Circulation (High) BTU/h k BTU/h BTU/h ft /min (m /h),00 7.0 Cooling ( 9,800 to,00 ) (.90 to 7.0 ),00,000,707 (,900) Electrical Rating Available Voltage Range V 87 to Running Amperes Power Input A.,60 Power Factor % 98 SEER BTU/h Compressor Locked Rotor Amperes A.0 Fuse or Circuit Breaker Capacity A 0 Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi and multi-steps) Compressor Refrigerant / Amount charged at shipment Ib. (g) DC Twin Rotary (Inverter) R0A / 6.7 (,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool db-a 0 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft. (m) 8 () Refrigerant Narrow tube inch (mm) Tube Diameter ide tube inch (mm) Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m ) Cooling / (6.) /8 (9.) + / (.7) 9-/8-7/6-9/ (70 900 0) -7/ 0-/8 6-/ (860,0 ) 8.9 7.7.7 (6.0) (67.0) (0.6) DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMS097 units Outdoor Unit : CLM7 unit. Rating conditions are: Cooling : Indoor air temp. 80 F D.B./ 67 F.B. Outdoor air temp. 9 F D.B./ 7 F.B. 8

Outdoor Unit CLM7 Indoor Unit KMS097 Type Number of Connectable Indoor Units Number of Operatable Indoor Units Voltage Rating -Room Multi Outdoor Unit 08V Single-Phase 60Hz < 08V > Performance Total Capacity Sensible Capacity Latent Capacity Air Circulation (High) BTU/h k BTU/h BTU/h ft /min (m /h),00 7.0 Cooling ( 9,800 to,00 ) (.90 to 7.0 ) 0,600,800,707 (,900) Electrical Rating Available Voltage Range V 87 to Running Amperes Power Input A.,60 Power Factor % 98 SEER BTU/h Compressor Locked Rotor Amperes A.0 Fuse or Circuit Breaker Capacity A 0 Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi and multi-steps) Compressor Refrigerant / Amount charged at shipment Ib. (g) DC Twin Rotary (Inverter) R0A / 6.7 (,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool db-a 0 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft. (m) 8 () Refrigerant Narrow tube inch (mm) Tube Diameter ide tube inch (mm) Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m ) Cooling / (6.) /8 (9.) + / (.7) 9-/8-7/6-9/ (70 900 0) -7/ 0-/8 6-/ (860,0 ) 8.9 7.7.7 (6.0) (67.0) (0.6) DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMS097 units Outdoor Unit : CLM7 unit. Rating conditions are: Cooling : Indoor air temp. 80 F D.B./ 67 F.B. Outdoor air temp. 9 F D.B./ 7 F.B. 9

Outdoor Unit CLM7 Indoor Unit KMS097 Type Number of Connectable Indoor Units Number of Operatable Indoor Units Voltage Rating -Room Multi Outdoor Unit 0V Single-Phase 60Hz < 0V > Performance Total Capacity Sensible Capacity Latent Capacity Air Circulation (High) BTU/h k BTU/h BTU/h ft /min (m /h) 0,600 9.00 Cooling ( 9,800 to 0,600 ) (.90 to 9.00 ),800,800,9 (,00) Electrical Rating Available Voltage Range V 87 to Running Amperes Power Input A.,800 Power Factor % 99 SEER BTU/h 6 Compressor Locked Rotor Amperes A 7.0 Fuse or Circuit Breaker Capacity A 0 Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi and multi-steps) Compressor Refrigerant / Amount charged at shipment Ib. (g) DC Twin Rotary (Inverter) R0A / 8.8 (,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool db-a Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft. (m) 00 (0.) Refrigerant Narrow tube inch (mm) Tube Diameter ide tube inch (mm) Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m ) Cooling / (6.) /8 (9.) + / (.7) -/ -7/6-9/ (890 900 0) 9-/ 0-/8 6-/ (,00,0 ) 7. 8.0.8 (79.0) (8.0) (0.) DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMS097 units Outdoor Unit : CLM7 unit. Rating conditions are: Cooling : Indoor air temp. 80 F D.B./ 67 F.B. Outdoor air temp. 9 F D.B./ 7 F.B. 0

Outdoor Unit CLM7 Indoor Unit KMS097 Type Number of Connectable Indoor Units Number of Operatable Indoor Units Voltage Rating -Room Multi Outdoor Unit 08V Single-Phase 60Hz < 08V > Performance Total Capacity Sensible Capacity Latent Capacity Air Circulation (High) BTU/h k BTU/h BTU/h ft /min (m /h) 8,600 8.0 Cooling ( 9,800 to 8,600 ) (.90 to 8.0 ),00,00,9 (,00) Electrical Rating Available Voltage Range V 87 to Running Amperes Power Input A.6,800 Power Factor % 99 SEER BTU/h 6 Compressor Locked Rotor Amperes A 7.0 Fuse or Circuit Breaker Capacity A 0 Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi and multi-steps) Compressor Refrigerant / Amount charged at shipment Ib. (g) DC Twin Rotary (Inverter) R0A / 8.8 (,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool db-a Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft. (m) 00 (0.) Refrigerant Narrow tube inch (mm) Tube Diameter ide tube inch (mm) Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping inch (mm) inch (mm) Ib. (kg) Ib. (kg) cu.ft (m ) Cooling / (6.) /8 (9.) + / (.7) -/ -7/6-9/ (890 900 0) 9-/ 0-/8 6-/ (,00,0 ) 7. 8.0.8 (79.0) (8.0) (0.) DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMS097 units Outdoor Unit : CLM7 unit. Rating conditions are: Cooling : Indoor air temp. 80 F D.B./ 67 F.B. Outdoor air temp. 9 F D.B./ 7 F.B.

-. Major Component Specifications --. Outdoor Unit Outdoor Unit CLM97 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 F (0 C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Crankcase Heater Micro F VAC CB-CLM97 Microprocessor 0V A DC Twin Rotary (Hermetic) KD0XAB /,700 FV0S....9 (900) U - V : 0.70 V - : 0.708 - U : 0.76 Yes Yes Yes CS-7LN Open : 9 F ( C), Close : F (00 C) - - 0V 0 Fan Type Q'ty... Dia. inch (mm) Propeller... D8-/8 (D60) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (0 C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Ohm Micro F VAC DC Motor SIC-7F-D90-... 8 70 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 8. Face Area ft (m ) 6.0 (0.9) External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE ITHOUT NOTICE.

Outdoor Unit CLM7 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 F (0 C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Crankcase Heater Micro F VAC CB-CLM7 Microprocessor 0V A DC Twin Rotary (Hermetic) KD0XAB /,700 FV0S....9 (900) U - V : 0.70 V - : 0.708 - U : 0.76 Yes Yes Yes CS-7LN Open : 9 F ( C), Close : F (00 C) - - 0V 0 Fan Type Q'ty... Dia. inch (mm) Propeller... D8-/8 (D60) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (0 C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Ohm Micro F VAC DC Motor SIC-7F-D90-... 8 70 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 8. Face Area ft (m ) 6.0 (0.9) External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE ITHOUT NOTICE.

Outdoor Unit CLM7 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 F (0 C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Crankcase Heater Micro F VAC CB-CLM7 Microprocessor 0V A DC Twin Rotary (Hermetic) JD0XAB /,000 FV0S.... (,00) U - V : 0. V - : 0. - U : 0. Yes Yes Yes CS-7LN Open : 9 F ( C), Close : F (00 C) - - 0V 0 Fan Type Q'ty... Dia. inch (mm) Propeller... D8-/8 (D60) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (0 C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Ohm Micro F VAC DC Motor SIC-7F-D90-... 8 800 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 8. Face Area ft (m ) 7.7 (0.7) External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE ITHOUT NOTICE.

-. Other Component Specifications Sensor Name Model No. of sensor Quantity of Sensor CLM97 CLM7 CLM7 Outdoor air temp sensor TKS9B Outdoor heat exchanger sensor TKS9B A / AN sensor TKS9B / / / B / BN sensor TKS9B / / / C / CN sensor TKS9B / / / D / DN sensor TKS9B 0 / / 0 Resistance (k ohm) 0 0 0 0-0 9 68 (-0)(-)(-0) (-) (0) () (0) () (0) Temperature F ( C) Sensor Name Model No. of sensor Quantity of Sensor CLM97 CLM7 CLM7 Compressor temp sensor TKS9B 00 80 Resistance (k ohm) 60 0 0 00 80 60 0 0 0 0 68 86 0 0 8 76 9 (0) (0) (0) (0) (0) (0) (60) (70) (80) (90) Temperature F ( C)

. DIMENSIONAL DATA Outdoor Unit CLM97 -/6 -/ -/8-7/ ID:/ -ID:/6 / -7/6(900) ide tube service valve dia./8" (9.) Narrow tube service valve dia./" (6.) / -9/ -7/ -/ -7/6 -/6 -/ 9-/8(70) -9/(0) -9/ -7/ -/6 -/6 -/ -/ -/6 Unit: inch(mm) 6

Outdoor Unit CLM7 -/6 -/ -/8-7/ ID:/ -ID:/6 / -9/(0) -9/ -7/ -7/6(900) -/6 ide tube service valve dia./8" (9.) Narrow tube service valve dia./" (6.) / 9-/8(70) -9/ -7/ -/ -/ ide tube service valve dia./" (.70) -/6 -/ -/ -7/6 -/6 -/ -/ -/6 -/ Unit: inch(mm) 7

Outdoor Unit CLM7 -/6 -/ -/8-7/ ID:/ -ID:/6 / -7/6(900) ide tube service valve dia./8" (9.) Narrow tube service valve dia./" (6.) ide tube service valve dia./" (.70) / -9/ -7/8 -/ -/ -7/6 -/6 -/ -/ -9/(0) -9/ -7/ -/(890) -/6 -/6 -/ -/ -/6 -/ Unit: inch(mm) 8

. REFRIGERANT FLO DIAGRAM -. Refrigerant Flow Diagram Outdoor Unit CLM97 Indoor unit Outdoor unit ide tube O.D./8" O.D./8" O.D./8" Service valve on wide tube C B A Header Sub accumulator Main accumulator High pressure switch H.P. Compressor Narrow tube O.D./" O.D./" O.D./" Service valve on narrow tube CN BN AN Strainer Electric expansion valve M M M Header Heat exchanger Cooling cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min./6"(8 mm). Thickness: Min./6"(8 mm) Insulation Thickness: Min./6"(8 mm) CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. ide tube Narrow tube 9

Outdoor Unit CLM7 Indoor unit Outdoor unit ide tube O.D./8" O.D./8" O.D./8" O.D./" Service valve on wide tube D C B A Header Sub accumulator Main accumulator High pressure switch H.P. Compressor Narrow tube O.D./" O.D./" O.D./" O.D./" Service valve on narrow tube DN CN BN AN Strainer Electric expansion valve M M M M Header Heat exchanger Cooling cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min./6"(8 mm). Thickness: Min./6"(8 mm) Insulation Thickness: Min./6"(8 mm) CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. ide tube Narrow tube 0

Outdoor Unit CLM7 Indoor unit Outdoor unit ide tube O.D./8" O.D./8" O.D./" O.D./" Service valve on wide tube D C B A Header Sub accumulator Main accumulator High pressure switch H.P. Compressor Narrow tube O.D./" O.D./" O.D./" O.D./" Service valve on narrow tube DN CN BN AN Strainer Electric expansion valve M M M M Header Heat exchanger Cooling cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min./6"(8 mm). Thickness: Min./6"(8 mm) Insulation Thickness: Min./6"(8 mm) CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. ide tube Narrow tube

. PERFORMANCE DATA -. Temperature Charts --. Temperature Charts (CLM97) Outdoor Unit CLM97 Indoor Unit KMS077 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 88 (.) 7 (.) 60 (.) 6 (.0) 77 () Lo fan Hi fan HH fan 86 (0) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) () Operating current performance chart 0 (0) Lo fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) () Indoor discharge air performance chart 0 (0) Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan Hi fan HH fan 86 (0) Indoor air temp. 86 F (0 C) 9 () Outdoor air temperature F ( C) 80 F (7 C) 7 F ( C) 0 (0) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6t (7.m). If the tubing length is different, the performance chart will vary.

Outdoor Unit CLM97 Indoor Unit KMS097 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 88 (.) 7 (.) 60 (.) Lo fan Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) HH fan 6 (.0) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Operating current performance chart 6 Lo fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan 86 (0) Outdoor air temperature F ( C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. Hi fan Indoor air temp. 86 F (0 C) 9 () 80 F (7 C) 7 F ( C) HH fan 0 (0)

Outdoor Unit CLM97 Indoor Unit KMS7 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 60 (.) 6 (.0) (0.9) 77 () Lo fan 86 (0) Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) HH fan 0 (0) () Operating current performance chart 6 Lo fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan 86 (0) Outdoor air temperature F ( C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () HH fan 0 (0)

Outdoor Unit CLM97 Indoor Unit KMS87 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 60 (.) 6 (.0) Lo fan Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) HH fan (0.9) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Operating current performance chart 8 Lo fan Hi fan HH fan Operating current (A) 7 6 Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan 86 (0) Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) HH fan 0 (0) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary.

--. Temperature Charts (CLM7) Outdoor Unit CLM7 Indoor Unit KMS077 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 88 (.) 7 (.) 60 (.) 6 (.0) 77 () Lo fan Hi fan HH fan 86 (0) Indoor air temp. 86 F (0 C) 9 () Outdoor air temperature F ( C) 80 F (7 C) 7 F ( C) () Operating current performance chart 0 (0) Lo fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) () Indoor discharge air performance chart 0 (0) Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan Hi fan HH fan 86 (0) Indoor air temp. 86 F (0 C) 9 () Outdoor air temperature F ( C) 80 F (7 C) 7 F ( C) 0 (0) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6t (7.m). If the tubing length is different, the performance chart will vary. 6

Outdoor Unit CLM7 Indoor Unit KMS097 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 88 (.) 7 (.) 60 (.) 6 (.0) 77 () Lo fan 86 (0) Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) HH fan 0 (0) () Operating current performance chart 6 Lo fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan 86 (0) Outdoor air temperature F ( C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. 7 Hi fan Indoor air temp. 86 F (0 C) 9 () 80 F (7 C) 7 F ( C) HH fan 0 (0)

Outdoor Unit CLM7 Indoor Unit KMS7 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 60 (.) 6 (.0) (0.9) 77 () Lo fan 86 (0) Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) HH fan 0 (0) () Operating current performance chart 6 Lo fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan 86 (0) Outdoor air temperature F ( C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. 8 Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () HH fan 0 (0)

Outdoor Unit CLM7 Indoor Unit KMS87 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 60 (.) 6 (.0) Lo fan Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) HH fan (0.9) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Operating current performance chart 8 Lo fan Hi fan HH fan Operating current (A) 7 6 Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan 86 (0) Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) HH fan 0 (0) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. 9

Outdoor Unit CLM7 Indoor Unit KMS7 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 60 (.) 6 (.0) Lo fan Hi fan HH fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) (0.9) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Operating current performance chart Operating current (A) 9 Lo fan 8 7 HH fan Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 6 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan 86 (0) Outdoor air temperature F ( C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. 0 Hi fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () HH fan 0 (0)

--. Temperature Charts (CLM7) Outdoor Unit CLM7 Indoor Unit KMS077 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 6 (.0) 8 (0.8) 90 (0.6) 77 () Lo fan Hi fan Hi fan HH fan 86 (0) Indoor air temp. 86 F (0 C) 9 () Outdoor air temperature F ( C) 80 F (7 C) 7 F ( C) 0 (0) () Operating current performance chart Lo fan Hi fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan Hi fan Hi fan HH fan 86 (0) Outdoor air temperature F ( C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. Indoor air temp. 86 F (0 C) 9 () 80 F (7 C) 7 F ( C) 0 (0)

Outdoor Unit CLM7 Indoor Unit KMS097 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 6 (.0) 8 (0.8) 90 (0.6) 77 () Lo fan Hi fan Hi fan HH fan 86 (0) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) 0 (0) () Operating current performance chart Lo fan Hi fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan Hi fan Hi fan HH fan 86 (0) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) 0 (0) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary.

Outdoor Unit CLM7 Indoor Unit KMS7 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 6 (.0) 8 (0.8) Lo fan Hi fan Hi fan HH fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 90 (0.6) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Operating current performance chart 6 Lo fan Hi fan Hi fan HH fan Operating current (A) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) () Indoor discharge air performance chart 0 (0) Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () Lo fan Hi fan Hi fan HH fan 86 (0) Outdoor air temperature F ( C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. Indoor air temp. 86 F (0 C) 9 () 80 F (7 C) 7 F ( C) 0 (0)

Outdoor Unit CLM7 Indoor Unit KMS87 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 6 (.0) 8 (0.8) Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) Lo fan Hi fan 90 (0.6) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Operating current performance chart 9 Lo fan Hi fan Operating current (A) 8 7 6 80 F (7 C) Indoor air temp. 86 F (0 C) 7 F ( C) 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () 86 (0) Lo fan Indoor air temp. 86 F (0 C) 9 () Outdoor air temperature F ( C) 80 F (7 C) 7 F ( C) Hi fan 0 (0) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary.

Outdoor Unit CLM7 Indoor Unit KMS7 Cooling Characteristics (RH : 6%, Indoor fan speed : High fan) (0V, 60Hz) () Low pressure performance chart Low pressure at wide tube service valve psig (MPaG) 7 (.) 6 (.0) 8 (0.8) 90 (0.6) 77 () 86 (0) Lo fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) 9 () Outdoor air temperature F ( C) Hi fan 0 (0) () Operating current performance chart Operating current (A) 0 9 Lo fan Indoor air temp. 86 F (0 C) 80 F (7 C) 7 F ( C) Hi fan 8 77 () 86 (0) 9 () Outdoor air temperature F ( C) 0 (0) () Indoor discharge air performance chart Indoor discharge air temperature F ( C) 68.0(0) 6.(8) 60.8(6) 7.().6() 0.0(0) 6.( 8) 77 () 86 (0) Outdoor air temperature F ( C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of.6ft (7.m). If the tubing length is different, the performance chart will vary. Lo fan Indoor air temp. 86 F (0 C) 9 () 80 F (7 C) 7 F ( C) Hi fan 0 (0)

-. Cooling Capacity Outdoor Unit : CLM97 Indoor Unit : KMS097 Power Supply : 0V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY: 9,700 BTU/h AIR FLO RATE: 88 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C).B. D.B. 6 7 8 9 0 (8.) (.9) (9.) (.0) (0.6) (6.) TC 9,800 9,00 8,0 7,770 6,890,90 7 (.) SHC 7,70 7,0 6,790 6,60 6,70,760 9 76 (.) SHC 9,800 9,00 8,0 7,770 6,890,90 (.0) 80 (6.7) SHC 9,800 9,00 8,0 7,770 6,890,90 8 (8.9) SHC 9,800 9,00 8,0 7,770 6,890,90 88 (.) SHC 9,800 9,00 8,0 7,770 6,890,90 TC 0,790 0,060 9,90 8,70 7,800 6,80 7 (.) SHC,0,870,0,60,00,670 6 76 (.) SHC 7,0 6,960 6,60 6,70,90,90 (7.) 80 (6.7) SHC 0,90 0,00 9,90 8,70 7,800 6,80 8 (8.9) SHC 0,790 0,060 9,90 8,70 7,800 6,80 88 (.) SHC 0,790 0,060 9,90 8,70 7,800 6,80 TC,790,00 0,0 # 9,700 8,70 7,70 7 (.) SHC 0,960 0,60 0,70 0,00 9,760 9,0 67 76 (.) SHC,870,700,60,90,80,0 (9.) 80 (6.7) SHC 6,960 6,790 6,0 6,70,90,90 8 (8.9) SHC 0,00 9,700 9,60 9,90 8,70 7,70 88 (.) SHC,790,00 0,0 9,700 8,70 7,70 TC,800,00,0 0,700 9,70 8,70 7 (.) SHC 7,60 7,90 6,80 6,670 6,0,980 7 76 (.) SHC 0,0 0,00 9,90 9,760 9,0 8,900 (.7) 80 (6.7) SHC,0,90,00,80,00,990 8 (8.9) SHC 6,0 6,70,90,760,0,070 88 (.) SHC 9,0 9,90 9,00 8,80 8,00 7,990 TC,690,90,080,600 0,90 8,90 7 76 (.) SHC 7,00 6,80 6,00 6,0 6,60,60 (.9) 80 (6.7) SHC 0,00 9,90 9,90 9,0 9,0 8,70 8 (8.9) SHC,90,80,670,00,60,60 88 (.) SHC 6,00,90,90,0,070,70 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 F (6.7 C) D.B. / 67 F (9. C).B. : Outdoor Ambient Temp. 9 F ( C) D.B.. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.. Above data represents the value when the operation frequency of a compressor is fixed. 6

Outdoor Unit : CLM7 Indoor Unit : KMS097 Power Supply : 0V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY:,00 BTU/h AIR FLO RATE: 88 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C).B. D.B. 6 7 8 9 0 (8.) (.9) (9.) (.0) (0.6) (6.) TC,690,800,80,90,00 7,90 7 (.) SHC 0,0 9,870 9,60 9,00 8,00 6,0 9 76 (.) SHC,0,790,70,00,0 7,90 (.0) 80 (6.7) SHC,690,800,80,90,00 7,90 8 (8.9) SHC,690,800,80,90,00 7,90 88 (.) SHC,690,800,80,90,00 7,90 TC 6,80,900,90,90,0 7,700 7 (.) SHC 6,790 6,0,90,760,0,00 6 76 (.) SHC 9,700 9,60 9,00 8,670 8,60,90 (7.) 80 (6.7) SHC,960,0,00,760,0 7,700 8 (8.9) SHC,870,0,90,90,0 7,700 88 (.) SHC 6,80,900,90,90,0 7,700 TC 7,90 6,980,970 #,00,80 8,070 7 (.) SHC,60,00,00,0,80 9,90 67 76 (.) SHC 6,70,90,90,0,900,00 (9.) 80 (6.7) SHC 9,60 9,00 8,670 8,0 7,990,90 8 (8.9) SHC,0,00,90,0 0,900 8,070 88 (.) SHC,60,00,670,0,80 8,070 TC 8,980 8,00 6,990 6,00,00 8,80 7 (.) SHC 9,90 9,0 8,900 8,70 8,0,980 7 76 (.) SHC,670,0,80,60,0 8,900 (.7) 80 (6.7) SHC,760,0,070,70,0,990 8 (8.9) SHC 8,670 8,0 7,990 7,80 7,00,070 88 (.) SHC,90,0 0,900 0,70 0,0 7,990 TC 9,880 8,90 7,870 7,60,0 8,90 7 76 (.) SHC 9,070 8,70 8,90 8,0 7,0,70 (.9) 80 (6.7) SHC,60,80,70,00 0,60 8,60 8 (8.9) SHC,070,70,90,90,700,60 88 (.) SHC 8,60 7,80 7,70 7,00 6,60,60 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 F (6.7 C) D.B. / 67 F (9. C).B. : Outdoor Ambient Temp. 9 F ( C) D.B.. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.. Above data represents the value when the operation frequency of a compressor is fixed. 7

Outdoor Unit : CLM7 Indoor Unit : KMS097 Power Supply : 0V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY: 0,600 BTU/h AIR FLO RATE:,77 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C).B. D.B. 6 7 8 9 0 (8.) (.9) (9.) (.0) (0.6) (6.) TC,70 0,000 8,70 8,00,960 6,690 7 (.) SHC,80,900,0,980,700 6,690 9 76 (.) SHC 9,70 9,00 8,0 8,00,960 6,690 (.0) 80 (6.7) SHC,70 0,000 8,70 8,00,960 6,690 8 (8.9) SHC,70 0,000 8,70 8,00,960 6,690 88 (.) SHC,70 0,000 8,70 8,00,960 6,690 TC,90,80 9,960 9,0,00 6,970 7 (.) SHC,00 0,0 9,870 9,60 7,0,60 6 76 (.) SHC,900,0,980,0,0 6,970 (7.) 80 (6.7) SHC 9,00 8,0 8,00 7,60,00 6,970 8 (8.9) SHC,90,80 9,960 9,0,00 6,970 88 (.) SHC,90,80 9,960 9,0,00 6,970 TC,790,0,70 # 0,600,770 7,00 7 (.) SHC 6,0,980,90,070,0 0,70 67 76 (.) SHC 0,0 9,870 9,0 9,80 6,670,0 (9.) 80 (6.7) SHC,0,980,0,00 0,780 7,00 8 (8.9) SHC 8,0 8,00 7,0 7,80,770 7,00 88 (.) SHC,0,980,70 0,600,770 7,00 TC,00,70,0,860,00 7,0 7 (.) SHC,0 0,90 0,90 0,90 7,70,690 7 76 (.) SHC,0,070,60,80,60 9,80 (.7) 80 (6.7) SHC 9,60 9,80 8,70 8,00,980,690 8 (8.9) SHC,0,070,60,60 9,870 7,0 88 (.) SHC 7,60 7,80 6,70 6,00,70 7,0 TC 6,00,70,70,90,0 7,90 7 76 (.) SHC 0,70 0,70 9,80 9,80 7,070,0 (.9) 80 (6.7) SHC,80,60,0,90,80 9,0 8 (8.9) SHC 8,90 8,00 8,00 7,80,90,0 88 (.) SHC,80,80,90,90 9,80 7,0 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 F (6.7 C) D.B. / 67 F (9. C).B. : Outdoor Ambient Temp. 9 F ( C) D.B.. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.. Above data represents the value when the operation frequency of a compressor is fixed. 8

-. Cooling Capacity (Low Ambient) Outdoor Unit : CLM97 Indoor Unit : KMS097 Power Supply : 0V Single Phase 60Hz < Cooling Capacity (Low Ambient) > RATING CAPACITY: 9,700 BTU/h AIR FLO RATE: 88 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C).B. D.B. 0 (-6.7) (-.9) (.7) (7.) (.8) TC 0,000 9,990 9,980 0,080 9,90 7 (.) SHC 7,60 7,60 7,60 7,60 7,70 9 76 (.) SHC 0,000 9,990 9,980 0,080 9,90 (.0) 80 (6.7) SHC 0,000 9,990 9,980 0,080 9,90 8 (8.9) SHC 0,000 9,990 9,980 0,080 9,90 88 (.) SHC 0,000 9,990 9,980 0,080 9,90 TC 0,0 0,60 0,0 0,70 0,60 7 (.) SHC,00,00,00,0,0 6 76 (.) SHC 7,0 7,0 7,0 7,0 7,0 (7.) 80 (6.7) SHC 0,0 0,0 0,0 0,0 0,0 8 (8.9) SHC 0,0 0,60 0,0 0,70 0,60 88 (.) SHC 0,0 0,60 0,0 0,70 0,60 TC 0,760 0,80,00,0,0 7 (.) SHC 0,60 0,60 0,60 0,790 0,790 67 76 (.) SHC,0,0,0,700,700 (9.) 80 (6.7) SHC 6,60 6,60 6,790 6,790 6,790 8 (8.9) SHC 9,0 9,700 9,700 9,870 9,870 88 (.) SHC 0,760 0,80,00,0,0 TC 0,90,080,00,890,960 7 (.) SHC 6,80 6,80 7,00 7,90 7,90 7 76 (.) SHC 9,760 9,760 9,90 0,00 0,00 (.7) 80 (6.7) SHC,80,00,00,90,90 8 (8.9) SHC,90,90 6,00 6,70 6,70 88 (.) SHC 8,80 8,80 9,00 9,90 9,90 TC 0,90,0,60,70,0 7 76 (.) SHC 6,60 6,0 6,0 6,670 6,670 (.9) 80 (6.7) SHC 9,0 9,0 9,90 9,760 9,760 8 (8.9) SHC,0,0,00,670,670 88 (.) SHC,0,0,0,90,760 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h). NOTE Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.. Above data represents the value when the operation frequency of a compressor is fixed. 9

Outdoor Unit : CLM7 Indoor Unit : KMS097 Power Supply : 0V Single Phase 60Hz < Cooling Capacity (Low Ambient) > RATING CAPACITY:,00 BTU/h AIR FLO RATE: 88 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C).B. D.B. 0 (-6.7) (-.9) (.7) (7.) (.8) TC,60,70,0,70,60 7 (.) SHC 0,00 0,0 0,0 0,0 0,0 9 76 (.) SHC,0,0,0,00,0 (.0) 80 (6.7) SHC,60,70,0,70,60 8 (8.9) SHC,60,70,0,70,60 88 (.) SHC,60,70,0,70,60 TC,690,760,960 6,0 6,0 7 (.) SHC 6,70 6,70 6,0 6,60 6,60 6 76 (.) SHC 9,60 9,60 9,60 9,0 9,0 (7.) 80 (6.7) SHC,0,0,0,60,60 8 (8.9) SHC,60,60,0,700,700 88 (.) SHC,690,760,960 6,0 6,0 TC,70,870 6,0 6,80 6,960 7 (.) SHC,00,00,670,80,80 67 76 (.) SHC,0,0,90,90,90 (9.) 80 (6.7) SHC 8,00 8,670 8,670 9,00 9,00 8 (8.9) SHC,90,90,760,90,90 88 (.) SHC,00,00,670,00,00 TC,80,70 6,0 7,0 7,0 7 (.) SHC 8,90 8,90 8,70 8,900 9,070 7 76 (.) SHC,00,70,60,990,990 (.7) 80 (6.7) SHC,90,60,70,070,070 8 (8.9) SHC 7,70 7,70 7,60 7,990 8,60 88 (.) SHC 0,90 0,60 0,70,070,070 TC,970,0 6,60 7,80 7,70 7 76 (.) SHC 7,60 7,0 7,870 8,0 8,90 (.9) 80 (6.7) SHC 0,60 0,60 0,960,00,70 8 (8.9) SHC,0,700,870,0,90 88 (.) SHC 6,0 6,60 6,960 7,00 7,00 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h). NOTE Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.. Above data represents the value when the operation frequency of a compressor is fixed. 0