Centrifugal electric pumps ATEX safety instructions

Similar documents
Elettropompe centrifughe Centrifugal electric pumps Electropompes centrifuges Fliehkraftpumpen Electrobombas centrífugas

USE. Steam dispensing. n 4 holes. How to access the programming function

CVEN x 1/1 GN 6-12 x 20 DEVICE FOR GASTRONOMY

GENOVA PANORAMA MC. Future. Technology. Innovation.

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780

Type Sup 037RG. Errata: Descaling. These instructions replace those reported in the manual.

05/2014. Mod: E99/PLA2-N. Production code: BEFT908L

Air-cooled heat pump USER MANUAL HBI IHBIFY _01

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

SIRIO Contatore di energia Energy meter

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent

TRASCO ATEX Couplings

Compact wall hung boiler. Micro processor Brass Hydraulic set

ANNEX GD-CERT-EX-EN SIT

ATTACK DPX USER MANUAL. for correct installation, operation and cleaning WOOD GASIFYING BOILER STANDARD / PROFI / LAMBDA

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO

SST FOR THE AIR CONDITIONING SYSTEM

Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet

Smart encoders & actuators

15x15 Diamantato White Lux 7,5x15 Diamantato White Lux 5x15 Cornice Liberty White Lux 2x15 Bullnose White Lux 11x15 Battiscopa 900 White Lux

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

ADDITIONAL FLUE GAS DRAUGHT FAN ATTACK PV150 INSTRUCTIONS FOR USE

NL Installatievoorschriften p. 3. FR Instructions d installation p. 5. DE Montageanleitung p. 7. EN Operating and installation Instructions p.

Operating instructions For Vibration level switch. Model NSV

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Zweifarbdesigns Two-colour designs Designs bicolores Design bicromatici

ATM Lighting sp. z o.o

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

OPTIBAR P 1010/2010 C Supplementary instructions

K-HA CENTRIFUGAL PRESSURE BOOSTING PUMPS. Technical Sheet

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

EtherCAT Box Modules (EPxxxx-xxxx)

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Sirène flash. Sirena con lampeggiante DP8406 DP8407 DP8408. Alarmsirene mit Blitzlampe. Siren and flashing. p. 19

BOBINE ANTIDEFLAGANTI (ATEX) ISTRUZIONI EXPLOSION PROOF COILS (ATEX) - INSTRUCTIONS

ATM Lighting sp. z o.o

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

ATEX, NOMENCLATURE AND CODING

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

ATEX, NOMENCLATURE AND CODING

Strand Lighting Emergency Transfer Cabinet

Technical Data. Dimensions

Constant Temperature Waterbaths

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

HALO ELITE BIVVY LIGHT

INSTRUCTION MANUAL VARIABLE TEMPERATURE KETTLE MANUEL D UTILISATION BOULLOIRE À TEMPÉRATURE VARIABLE MANUAL DE USO HERVIDOR DE TEMPERATURA VARIABLE

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

INSTRUCTION MANUAL (ATEX / IECEx)

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

1. GENERAL TECHNICAL INFORMATION

manual addendum DELPHI Ex

METALDRIVE ATEX Couplings

Co170 ARMOURED WALL BURGLAR PROOF GRADE 2 ACCORDING TO UNI EN1143

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

R4952. SELECT wash basin lifter. Operation and maintenance manual

OPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

The CE Marking Access to the European Market

Translation of the assembly instructions with operating instructions and technical appendix

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

OilMatic Pro / 230 V AC

This is a preview - click here to buy the full publication INTERNATIONAL STAN DARD. Radio-frequency connectors

Dräger PIR 3000 Detection of flammable gases and vapours

Operating Instructions for Liquid Level Transducer Model : MM Series

FOREFRONT AT THE OF PROTECTION

V80-H Multistage Pump Instruction Manual

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

AZN ATEX INSTALLATION AND MAINTENANCE

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

ProSet Nose Equipment for Avdel Breakstem Rivets

Technical Data. Dimensions

Grasso SC Series. Grasso. Screw compressors forindustrial refrigeration. GEA Refrigeration

Firefighting units constructed in compliance with UNI EN and UNI standards

Millo / Millo pro. Nr x000 / 1805-x000

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

ACN SMOKE INSTALLATION AND MAINTENANCE

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Technical Data. Dimensions

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

IMESA: A LIFE BY YOUR SIDE

Blixer 4 P.O. Box 16625, Jackson, MS

Technical Ventilation

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Hardware User s Manual

CENTRIFUGAL FANS user's manual. model VENTS VK.

Flameproof Manual Call Points

BMA 0010 Instruction and Installation Manual Oil-Air Cooler ACN

Transcription:

Centrifugal electric pumps ATEX safety instructions

CONTENTS Page 1. Foreword..................... 8 2. Technical Data................ 9 3. Installation Instructions:....... 10 - General Information - Usage warnings - Additional warnings for pumps with detachable motor.............. 11 ENGLISH Number: SP-02 7

ENGLISH 1. Foreword The centrifugal pumps in the AT, AG and XT series are electromechanical devices. To ensure they operate correctly, they must only be used immersed in a liquid in a small container. By means of the impeller, the pumps suck in the liquid in which they are immersed, increase its speed and pressure, and push it into the delivery pipe. The electric pumps are available in the following versions: AT and AG series: single-block XT series: with detachable motor The speed of rotation varies according to the polarity of the motor used and the power supply frequency (4 or 2 poles; rated speed of rotation from 1500 to 3000 rpm at 50 Hz, from 1800 to 3600 rpm at 60 Hz). According to the ATEX directive, these motors must also be suitable for the following alternative uses: in areas classified with the presence of gas, category II 2G, Ex-d/Ex-de protection, IIB or IIC group, T5 temperature class, IP5x or IP6x protection class (ambient temperature: Ta 20 C, + 40 C) or T4 or T3 (Ta 20 C, + 60 C). in areas classified with the presence of dust, category II 2D, Ex-tD - A21 protection, IP65 mechanical protection, maximum surface temperature: T135 C or T150 C. This manual is an addition to the basic Rotating electric machines - low voltage manual and the Safety Instructions manual and must therefore be referred to along with these when installing, starting up, and carrying out maintenance on the motor. The diameter and shape of the impeller may vary according to the type of application and the size of the pump. The centrifugal pumps in the AT, AG and XT series are group II 2G/II 2GD, devices, suitable for use in areas classified with the presence of gas and/or dust, and are designed and built in accordance with the ATEX 94/9/EC directive. The pumps in the AT, AG and XT series are designed and built in accordance with the European standards: EN 1127-1, EN 13463-1 and EN 13463-5. The motors used for driving the centrifugal electric pumps are subjected to separate certification. 8

2. Technical data The electrical characteristics and other details of the motor, such as: certification, group, category and protection mode, are printed on the motor s data plate. The technical characteristics of the pump are printed on the data plate and define: Type of pump and height of suction Capacity and head Ambient temperature Maximum temperature of fluid Warning: The maximum allowed temperature for the fluid is 60 C. MARKING FOR GASES Mark of conformity with the applicable European directives II 2G c EC marking specific for protection against explosions Device for above ground plants with the presence of category 2G gases, vapours or mists Construction safety c ENGLISH Tx Ta TL max + 60 C A xxxxxx yy ATEX 03 PUMPEX T5 / T4 / T3 temperature class Ambient temperature (-20 C +60 C) Maximum temperature of fluid Serial number (A = year, xxxxx = job order no., yy = progressive job order no.) Reference of Technical File submitted to the Notified Body MARKING FOR DUST Mark of conformity with the applicable European directives EC marking specific for protection against explosions II 2GD Device for above ground plants with the presence of category 2D dust c T135 C (T100 C) (T85 C) Ta TL max + 60 C A xxxxxx yy ATEX 03 PUMPEX Construction safety c Maximum surface temperature Ambient temperature (-20 C +60 C) Maximum temperature of fluid Serial number (A = year, xxxxx = job order no., yy = progressive job order no.) Reference of Technical File submitted to the Notified Body 9

ENGLISH 3. Installation instructions General information Before installing, using and maintaining the pump, read these safety instructions carefully. The instructions given in this manual must be observed in addition to those given in the motor s safety and use and maintenance manuals. The electric motors installed on the electric pumps must meet the following requirements: separate ATEX certification, suitability for the operating environment, and also for the substances present (gas group or type of dust), temperature class (if used in areas with the presence of gas) or maximum surface temperature (when used in areas with the presence of dust) that is compatible with the substances present in the operating environment, suitability to function at the temperature of the room in which it is used. For the safety matters associated with the use of the motor, see the relevant operating and maintenance instructions and the safety instructions. The electric devices and components are not to be opened when on. Usage warnings The centrifugal pumps in the AT, AG and XT series are to be installed and maintained in accordance with the systems and maintenance rules for environments classified against the risk of explosion due to the presence of gas and/or dust (for example: EN 60079-14, EN 60079-17, EN 61241-14, EN 61241-17 or other national rules/standards). The centrifugal pumps in the AT, AG and XT series are to be connected to earth using a special tamperproof connecting element (to prevent accidental loosening and turning). The single-block pumps in the AT and AG series have the earth screw located inside the terminal box and on the outside of the motor enclosure. The detachable pumps in the XT series have the earth screw situated on the flange of the pump body. The pumps must always be immersed in liquid while in use, to prevent them from overheating. The minimum level of liquid must cover the feed screw (see figure 1). It is possible to verify the level of liquid either directly or indirectly; for example, through an indicator scale or by checking pump capacity, or the pressure on the delivery pipe. If the pump is used in an area classified for the presence of dust, the pump must have a motor that is suitable for the environment (category 2GD) and the fittings between the pump and the tank of liquid must also include a suitable gasket placed under the pump flange. In presence of combustible powders, it is necessary to eliminate the layer of powder by regularly cleaning the machine and removing the layer with suitable equipment. Check the following points periodically, according to the frequency of use: - wear of the shaft guide bushes. To replace them, send the pump to its manufacturers or to an authorized service centre; - presence of vibrations and/or abnormal noises. In this case, stop the pump, check for the causes and contact the manufacturers; - presence of scaling, especially in the case of a prolonged stop. The pump is always to be kept clean to prevent the formation of scaling, deposits, films, etc.. These formations may cause the pump to malfunction and, in particular, block its shaft. The connection with the hydraulic circuit must be made with metal pipes. The user must provide a filter for the suction pipe to prevent foreign bodies and/or dirt getting into the impeller. Exhaust or recirculating valves must be fitted to the delivery pipe. Figure 1 ZONE 1 Minimum level 10

Additional warnings for pumps with detachable motor The motor and pump are fitted together by means of a bayonet fitting between the flange on the motor and the flange on the pump body; once the parts have been joined (through rotation by a few degrees) secure them by tightening the screw. See Figure 2. Lock The safety ring on the pump shaft near the feed screw prevents friction between the impeller and the cover of the pump body, to avoid potentially dangerous situations, should the pump be released accidentally. The user must check periodically the position of the safety ring against the pump body (minimum distance > 0.5 mm, maximum distance 1.0 mm). See Figure 4. The check is to be made using a thickness gauge, with the motor fitted to the pump body ENGLISH Figure 2 Unlock < 0,5 mm > 1,0 mm The motor shaft is joined to the pump shaft by a joint with a magnet at the top to ensure that the joint is secure and that the pump shaft is in a correct working position. The user must check periodically that the magnet is clean, that the joint is free of wear and working properly. In particular, this operation is to be performed whenever the motor is separated from the pump body. See Figure 3. Figure 4 Magnet Figure 3 11

Nel redigere questa documentazione è stata posta ogni cura al fine di assicurare la correttezza delle informazioni contenute. Tuttavia, anche in conseguenza della politica di continuo sviluppo e miglioramento della qualità del prodotto perseguita da Cemp, la società si riserva il diritto e la facoltà di apportare modifiche di qualsiasi genere, in qualsiasi momento e senza preavviso, sia a questo documento sia ai propri prodotti. Le descrizioni e le caratteristiche tecniche della presente pubblicazione non sono quindi impegnative e i dati riportati non costituiscono, in nessun caso, impegno contrattuale. Every care has been taken to ensure the accuracy of the information contained in this publication. Due to Cemp s policy of continuous development and improvement, the company reserves the right to supply products which may differ slightly from those illustrated and described in this publication. Descriptions and technical features listed in this brochure may not be considered as binding. Under no circumstances should data in this publication be considered as a contractual obligation. Dans la préparation de cette documentation nous avons pris le soin d y intégrer les informations les plus exactes possibles. Néanmoins, compte tenu de notre politique de développement et d amélioration continue des produits, la Société Cemp se réserve le droit et la faculté d apporter toute modification sur la documentation et sur les produits, à tout moment et sans préavis. Les descriptifs et les caractéristiques techniques contenus dans ce catalogue n engagent pas la Société. Par conséquent, ces données ne constituent en aucun cas un engagement contractuel. Die Ausführungen und technischen Eigenschaften, die in dieser Broschüre angegeben sind, dürfen nicht als verbindlich angesehen werden. In keinem Fall können jedoch die in diesem Dokument aufgeführten technischen Daten als rechtlich verbindlich angesehen werden. Cemp behält sich das Recht vor, ohne Mitteilung, jegliche Abweichungen und Änderungen jederzeit vorzunehmen, sowohl in diesem Dokument als auch bei den Produkten, die hier beschrieben sind. La presente documentación se ha redactado de manera muy atenta para poder asegurar que las informaciones que contiene son correctas. No obstante, como consecuencia de la política de continuo desarrollo y mejora de la calidad del producto que Cemp pone en práctica, la sociedad se reserva el derecho y la facultad de modificar en lo que fuera necesario, en cualquier momento y sin que para ello medie preaviso alguno, tanto este documento como sus productos. Por lo tanto, las descripciones y las características técnicas indicadas en el presente documento no son vinculantes, y los datos que contiene no constituyen en ningún caso, vínculo contractual.

HEADQUARTER Cemp srl Via Piemonte, 16 20030 Senago (Milano) - Italy Tel. +39 02 94435401 Fax +39 02 9989177 info@cemp.eu BRANCH Germany Dr. Atzinger-Strasse 5 94036 Passau - Germany Tel. +49 (0)851 9662320 Fax +49 (0)851 96623213 cemp-deutschland@cemp.eu OFFICES France 14 rue des Cours Neuves, 77135 Pontcarré - France Phone +33 01 64660548 Fax +33 01 64660582 cemp-france@cemp.eu Dubai GT3, Office 001 Jebel Ali Free Zone - Dubai - UAE Phone +971 4 8812666 Fax +971 4 8812662 cemp-uae@cemp.eu www.cemp.eu - www.regalbeloit.com