Humidity Chambers HCP

Similar documents
CO 2 Incubators INCO 2

Constant climate chambers HPP Humidity chambers HCP

Absolutely precise control of temperature, humidity, CO 2 and O 2 content from the experts for controlled atmosphere

Vacuum Ovens VO. From orange juice to electronic chips vacuum technology protects heat-sensitive materials

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

ICH260C. Climate Chamber. Product specification

ICH110. Climate Chamber. Product specification

ICH750L. Climate Chamber. Product specification

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR INCOmed COMPRESSOR-COOLED INCUBATOR ICP

ICP450. Compressor-cooled incubator. Product specification

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR INCOmed COMPRESSOR-COOLED INCUBATOR ICP

Waterbaths & Oilbaths

Constant climate chambers

Constant climate chambers


Constant climate chamber with humidity

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

Heating and drying ovens

Constant climate chamber with ICH-compliant illumination

Heating and drying ovens

Constant climate chambers

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I. CO2 INCUBATOR ICOmed. COMPRESSOR-COOLED INCUBATOR ICPeco/ICP

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR INCOmed COMPRESSOR-COOLED INCUBATOR ICP

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

good reasons for a Memmert

Drying and heating chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Model KBF 240 Constant climate chambers with large temperature / humidity range

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR ICOmed COMPRESSOR-COOLED INCUBATOR ICP

Environmental simulation chamber for complex alternating climate profiles

Heating and drying ovens

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Constant climate chambers

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Model KBWF 240 Growth chambers with light and humidity

Vacuum drying oven for non-flammable solvents

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Plant growth chambers

Model KBWF 720 Growth chambers with light and humidity

CO₂ incubators. C CB series

Vacuum drying VD VDL series

Constant climate chambers

CO₂ incubators. C CB series

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model C 170 CO 2 incubators with hot air sterilization

Safety vacuum drying oven for flammable solvents

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

EC 160 CO 2. Incubator

BINDER Scientific Product Catalog

Heating and drying ovens

KMF Environmental test chamber for constant climate

Heating and drying ovens

ICO ADDITIONAL ACCESSORIES CO 2 INCUBATOR ICO

www

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Chromatographic Air circulated Refrigerator, two-door TC 603

Heating and drying ovens

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

OPERATING INSTRUCTIONS. Waterbath WNE 7-45 WPE 45. Oilbath ONE 7-45

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

Worldwide Leader in Technology

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Protect your research

PR / MP I Laboratory / Medicine

Platelet bags constant shaking for long periods of time.

Refrigerators and freezers Research and laboratory 2018

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Constant climate chambers

Constant climate chambers

Vacuum drying chambers. VD VDL series

VD 53 - Vacuum drying oven for non-flammable solvents

Thermo Scientific Heraeus Heating and Drying Ovens

Operating Instructions. Sterilisers SNB SFB Universal ovens UNB UFB Incubators INB

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

ULTRA.GUARD ultra low temperature freezer

Constant climate chambers

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Service Instructions

Internet. Climate rating definitions. Customer service.

ADDITIONAL ACCESSORIES 100% ATMOSAFE. MADE IN GERMANY.

Reproducible Climate...

Refrigerators and freezers Pharmacy and laboratory 2016

incubator, the best in its class

BINDER Industrial. Product Catalog

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

NEW GENERATION. Efficient use of valuable space INCUBATORS

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

FITOCLIMA 600 & 1200 STABILITY

Transcription:

Humidity Chambers HCP Optimal security through triple temperature monitor Up to 40 time ramps for combined temperature and humidity setpoints, programmable directly on the chamber Active humidification system for control range between 20% and 95% relative humidity 3-level security Wide-ranging convenience Humidity without condensation >>>> www.memmert.com

Active humidity control In addition to the precisely controlled temperature, a stable and accurately adjustable humidity plays a decisive role in creating ideal environments for the chamber load. The active humidification system of the HCP controls the humidity through a steam generator with controlled evaporation of water and sterile dry steam mixed into the air flow. As a result the HCP has a working range of 20 95% relative humidity. Your advantage: many different applications, low contamination risk and short recovery time after opening the door. Humid atmosphere without condensation With up to 40 ramps for temperature and humidity, active humidity control from 20% to 95% rh, and accurate temperature control up to 90 C, the humidity chamber HCP creates inside it a controlled, physiologically ideal environment for simulating real conditions. Without addition of moisture the temperature inside the HCP can be regulated up to 160 C. Uniformity inside the chamber Chamber heating from all six sides is an essential factor for avoiding the formation of condensate inside the chamber. An aluminium heat-conducting jacket helps to ensure optimal temperature distribution and in addition serves as heat store in case of a temporary supply outage. The turbulence-free chamber ventilation provides a uniformly homogeneous atmosphere. 3 sizes: 108 153 246 litre chamber volume Stainless steel the noble material The Memmert humidity chamber this is fine-tuning to perfection: for absolutely reliable experimental procedures with a maximum of security and operating convenience. 2 The inner chamber of the HCP consists exclusively of high-grade and fully recyclable stainless steel. The additional electropolishing of the chamber ensures particularly smooth and hygienic surfaces and therefore the greatest possible reduction in contamination risk. The outer casing is made mainly from sturdy textured stainless steel (except rear of zincplated steel) and is in accord with Memmert s holistic quality philosophy.

Every wish satisfied! A Memmert special: the chamber is made to 100% of high-grade stainless steel mat. 1.4301 (ASTM 304) and is additionally electropolished for maximum protection against contamination. The HCP is a model of reliability and accuracy. Innovations in control engineering ensure maximum security; up to 40 ramps for temperature and humidity settings provide flexibility in application. The all-round heating is located below deepdrawn ribs which carry the anti-tipping stainless steel shelves and at the same time ensure optimal and particularly gentle heat transfer to the chamber load. Bacteria-free through sterilisation function desinfection is not sufficient! Hygiene is fundamental, especially in high-sensitivity applications with organic materials. For that reason the entire chamber, including the ventilation system and all sensors, can be sterilised at 160 C in a 4-hour programme. For safety reasons this function can only be operated by means of the Memmert STERICard in order to prevent unintentional activation. Convenience: made for you The HCP is easy to use: Clear, easy-to-clean underglass function display Memmert s unique feature: the patented push-turn control for intuitive selection from the entire menu Feet with height adjustment as standard Quick-release connector for water supply Fully insulated stainless steel door and additional glass door Documentation: for controlled quality The basic outfit for professional quality assurance: Standard Celsius software for remote control and documentation, also optional FDA-conforming software (extra charge) Internal ring memory for uninterrupted, long-term documentation fully protected against manipulation (approx. 3 months) Parallel printer interface for printouts of thermostating processes (USB printer via converter possible) USB interface for programming and storage (Ethernet at extra charge) Printer interface USB Ethernet LAN 3

Perfect simulation of reality! Accuracy: for regulated procedures Technical features for faultless processes: Internal ventilation for turbulence-free and uniform temperature distribution Multi-functional fuzzy-supported control for exact setting and maintenance of setpoint temperature and humidity Calibration facility for temperature and humidity on the actual controller Option (extra charge): up to three additional and freely positionable Pt100 sensors for indication on the display and recording in the document store Flexibility: 40 ramps, programmable on the actual chamber Essential for accurate simulation of environmental conditions in research: the user-friendly ramp programming facility. Different temperature and humidity setpoints can be combined on up to 40 time ramps. 90 50 20 C rh [%] 90 50 10 temperature 1 3 2 4 5 relative humidity t Security: of course! Still more functions with no error: Integral auto-diagnostic system with visual and audible error indication Triple temperature monitor with mechanical temperature limiter (TB), electronic adjustable temperature monitor (TWW), as well as the Memmert ASF (Auto-Safety Function) Two high-grade platinum sensors communicate with each other like a climbing team on a rope and secure uninterrupted faultless temperature control. The high-grade 4-wire circuit ensures precise transmission of the measurements. Audible signal on over- and undertemperature, over- and underhumidity, empty water tank and open door Option (extra charge): volt-free contacts on combination error and setpoint reached MEMoryCard XL for programming up to 40 ramps for temperature and humidity setpoints as well as for documenting the temperature Option (extra charge): protection against unauthorised operation through chamber-linked personal User-ID-Card 4

Timer module 1 Time indication (real-time) 2 Text messages Temperature module 22 Heating 23 Sterilisation operation 24 Setpoint/actual temperature Temperature adjustment without humidity: 20 C to 160 C (control range from 8 C above ambient temperature up to 160 C) Temperature adjustment with humidity: 20 C to 90 C (control range from 8 C above ambient temperature up to 90 C) Variation (time): ±0.1 C max. Uniformity (spatial) ±0.3 C max. at 50 C Monitor module 25 Visual alarm 26 Alarm limit (temperature for heating cut-off) 27 Sounder 28 LOW alarm limit 29 Automatic alarm limit (ASF) 30 Temperature limiter 31 HIGH alarm limit Audible and visual alarm on temperature and humidity out of limit, on door open longer than 2 minutes, and on other errors 1 8 9 10 11 15 12 13 14 22 23 24 25 26 27 32 2 17 3 4 5 6 7 16 18 30 28 29 31 33 34 19 20 21 Operating mode 3 Normal operation (active) 4 Weekly timer* 5 Ramp timer (relative-time programme) 6 Printer 7 Configuration 8 Wait (at programme start) Hold (during programme) 9 Heating ramp 10 SP.WT programme continues when setpoint is reached 11 Hold ramp 12 Cooling ramp 13 Sounder at ramp timer end 14 Repeat function 15 Edit (ramp timer) 16 Stop (ramp timer) 17 Start (ramp timer) 18 Data manipulation prevented through optional User-ID-Card (extra charge) 19 SET key 20 Push-turn control 21 Chip card reader for STERICard and optional User-ID-Card (extra charge) * Weekly timer programmable with one ON and OFF time per weekday, additional group function (e. g. Mo Fr) Humidity module 32 Setpoint /actual humidity 33 Water level in storage tank 34 Steam generation Rh concentration selection: 20-95% Variation (time): ±1% max. 5

Technical data, models and accessories for Humidity Chamber HCP (Humidity Chamber Perfect) Interfaces: USB printer interface 75 D A 75 supply cable parallel interface USB interface F C 38 38 202 optional (extra charge): Ethernet LAN H 2 O inner glass door Dimensions of humidity chambers HCP (see table below) adjusting screw 12 8 mm (minimum height) E B 76 Model sizes HCP 108 153 246 Stainless steel Volume approx. l 108 153 246 interior (deep-drawn, Width / Height / Depth (less 25 mm for air duct in the middle of the back wall) (A) / (B) / (C) mm 560 / 480 / 400 480 / 640 / 500 640 / 640 / 600 electropolished) Provision for sliding stainless steel shelves or wire grid shelves number 5 7 7 Stainless steel Width (D) mm 710 630 790 exterior (rear zincplated Height (variable through adjustable feet) (E) mm 778 938 938 steel) Depth (without door handle, depth of handle 38 mm) (F) mm 550 650 750 Fully insulated, heated stainless steel door Extra internal glass door Ventilation Uniform atmosphere and temperature distribution through enclosed non-turbulent ventilation system, fully covered by the sterilisation process Temperature Electronic microprocessor temperature controller with Pt100 and auto-diagnostic system Temperature sensors Pt100 Class A in 4-wire circuit for uninterrupted operation on failure of one Pt100 with warning indication double double double Temperature range with humidity control C from 20 1) up to 90 from 20 1) up to 90 from 20 1) up to 90 Temperature range without humidity control C from 20 1) up to 160 from 20 1) up to 160 from 20 1) up to 160 (during sterilisation the temperature is fi xed at 160 C set value) Temperature variation in time (to DIN 12 880: 2007-05) C ± 0,1 ± 0,1 ± 0,1 Temperature uniformity in chamber at 50 C (to DIN 12 880:2007-05) C ± 0,3 ± 0,3 ± 0,3 Sterilisation STERICard for automatic chamber sterilisation cycle 4 h at 160 C (not for sterilising the load!) Humidity Capacitive humidity sensor (sterilisable) Active microprocessor control for humidifying and dehumidifying (20 95 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation; humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam, dehumidifying via sterile fi lter Monitor Microprocessor temperature monitor acting as overtemperature protection, with Pt100 incorporating fault diagnostics with visual and acoustic alarm Digital over- and undertemperature monitor Temperature monitoring band automatically linked to the setpoint (ASF) Relay for reliable heating cut-off in case of fault 6 Timer functions Mechanical temperature limiter (TB) Acoustic alarm: Over- and undertemperature; over-/underhumidity; open door and empty water tank Real-time/weekly programmer with group function (e.g. Monday-Friday) Timer with residual running time: max. 40 ramps (each 1 min. up to 999 h) programmable through controller or MEMoryCard XL; programming via PC and free-of-charge software: unlimited number of ramps

Model sizes HCP 108 153 246 Documentation Internal log memory 1024 kb as ring memory for all setpoints and actual values of temperature and humidity, errors, settings with real-time and date; capacity approx. 3 months at 1 min intervals Parallel printer interface for printing logging fi les, suitable for all PCL3-compatible ink jet printers (USB available via converter, see accessories) Celsius 2) software for control and documentation of temperature and relative humidity Setup Calibration (no separate PC required), temperature: 3-point calibration on controller, humidity: 2-point calibration at 20% and 90% Setting of language for dialogue and display D / UK / E / F / I Further data Electrical supply 3) V / Hz 230 / 50/60 230 / 50/60 230 / 50/60 Electrical load approx. W 1000 1500 2000 Net weight / Gross weight approx. kg 70 / 78 82 / 114 110 / 160 Standard Stainless steel sliding shelves number 2 2 2 accessories Shelf or wire grid shelf width (grids to order; extra charge) approx. mm 556 480 640 Shelf or wire grid shelf depth approx. mm 361 400 500 Works calibration certifi cate (test point chamber centre at 60 C) Standard version Humidity Chamber HCP HCP 108 HCP 153 HCP 246 Options Additional Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented H8(x) H8(x) H8(x) via the Celsius 2) software or on an attached printer Extra stainless steel shelf E7(x) E7(x) E7(x) Extra wire grid shelf (for good air circulation) E3(x) E3(x) E3(x) Moisture-tight entry port for introducing connections at the side, left centre/centre F0 F0 F0 can be closed from inside by silicone stopper, left centre top F1 F1 F1 (standard position centre/centre or centre top, right centre/centre F2 F2 F2 23 mm clear diameter) right centre top F3 F3 F3 Stacking version for 2 units of equal size (bottom unit modifi cation) G3 G3 G3 Subframe (622 mm high) 4) G5 G5 G5 Subframe (130 mm high for 2 stacked cabinets) 4) G7 G7 G7 Temperature profi le write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps V3 V3 V3 Additional chip card, blank, formatted (32 kb MEMoryCard XL for a maximum of 40 ramps) V4 V4 V4 STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising the load!) V9 V9 V9 Oven-linked authorisation card (User-ID-Card) prevents undesired manipulation by unauthorised third parties V1 V1 V1 Computer interface RS485 (for networking a maximum of 16 ovens) instead of USB interface V2 V2 V2 RS232 interface instead of interface USB W6 W6 W6 Interface Ethernet instead of interface USB inclusive software Celsius Ethernet-Edition W4 W4 W4 Parallel/USB converter cable with integrated power supply unit to connect PCL-3 compatible HP printers with USB interface to MEMMERT units W1 W1 W1 Documentation package consisting of parallel USB converter cable including PLC3- compatible HP colour inkjet printer with USB interface (HP Deskjet 6940 or successor) for direct connection W2 W2 W2 of printer to Memmert unit USB connection cable for computer interface W7 W7 W7 Connection cable for computer interface RS232 according to DIN 12 900-1 V6 V6 V6 Process-dependent electromagnetic door lock D4 D4 D4 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint of temperature and rh is reached) H5 H5 H5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message of temperature and rh controller (e. g. supply failure, sensor fault or fuse) H6 H6 H6 Works calibration certifi cate for 80% rh (measured at 50 C) Z5 Z5 Z5 IQ check list with works test data for humidity chamber as support for validation by customer Q1 Q1 Q1 OQ check list with works data for one freely selectable humidity and temperature value 5) incl. temperature distribution survey for 27 measuring points to DIN 12 880: 2007-05 Q2 Q2 Q2 as support for validation by customer Software Celsius FDA Edition 6) for up to 16 units. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Q3 Q3 Q3 Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA) Integration of additional units (up to max. 16 units) into an already existent FDA-software licence Q4 Q4 Q4 Start-up of HCP and brief training 7) (Germany only) through MEMMERT service. Requirement: humidity chamber is at its fi nal location and all services have been provided by the purchaser. (Applies only in connection with orders and payments for new units) K9 K9 K9 Subject to technical modifi cations Standard model, basic specifi cation Not available (x) Please specify quantity required after the order number 1) Operating range from 8 C above ambient 2) MEMMERT Celsius software (from version 10.0) has been tested for Windows NT 4, 2000, XP and Vista 3) Other voltages upon request 4) Screws for adjusting height are taken out of the feet and mounted into the subframe 5) Additional temperature and humidity values at extra cost for each additional value 6) Requires Windows 2000 Professional or XP Professional 7) Service not subject to any discount 7

OUR PROGRAMME Universal ovens Incubators Hot air sterilisers Ovens Memmert GmbH + Co. KG P.O. Box 1720 D-91107 Schwabach Germany Tel. +49 (0) 9122 / 925-0 Fax +49 (0) 9122 / 145 85 E-Mail: sales@memmert.com Vacuum ovens Peltier-cooled incubators Compressor-cooled incubators Cooled incubators CO 2 incubators Humidity chambers Constant climate chambers Climatic test chambers Water- and oilbaths Your Memmert Partner Upon your request we are pleased to send you detailed brochures www.memmert.com Some of the illustrations in this publication include special accessories. We reserve the right of technical modifications. Dimensions are subject to confirmation. Order No. D10211 Printed in Germany HCP 0906 e 5.0 by Memmert GmbH + Co. KG