Koffel Associates, Inc.

Similar documents
Antifreeze Solutions and Automatic Fire Sprinkler Systems. March 12, 2013

ANTIFREEZE AND AUTOMATIC FIRE SPRINKLERS UPDATE. Presented by: Jerry Schultz The FPI Consortium, Inc. July 28, 2017

9/15/ Cantara Lane Vista, CA (760)

2. Add a new definition as and related annex note to read as follows:

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

The Antifreeze Fire Sprinkler System Dilemma Eliminating One Issue has Opened the Door to Another. Jennifer Poynter, Esq. Charles B.

NFPA 45 NFPA 211 NFPA 1600

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/

NFPA 25 and the Influence of Liability

Freezing of Water-Based Fire Protection Systems

Fire Prevention Coffee Break Training. May 2017

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

1. Add a new definition as to read as follows:

Slide 2 NFPA 25: 2017

9/10/12. NFPA Consumer Alert Antifreeze sprinkler systems. Dear Fire Sprinkler System Owner,

Iowa State Fire Marshal

Understanding, Applying and Enforcing NFPA 25. James D. Lake NFSA Director of Training

Understanding and Applying NFPA 25

Winnipeg Fire Department Fire Prevention Branch

Changes for the New Edition. Senior Engineer, NFPA NFPA

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Chapter 4: Fire Protection Systems

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

NFPA Edition. NFPA 13 (2016 Edition) Hot Topics and NFPA 13 FAQ s. Highlights of 2016 Changes. Storage Commodity Classification 4/29/2014

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

NFPA Edition Update

INSIDE NFPA NEWS. Committee Leadership Conference. Comments Sought on Proposed Tentative Interim Amendments. Volume 14 Number 14 December 2010

Fire Alarm Inspection, Testing, Maintenance. Assuring the System s Operational Reliability

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Fire Sprinkler System Design and Installation Requirements

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

SFPE Austin/San Antonio Chapter Meeting

3/6/2018. Design Tips For Fire and Smoke Barriers. Professional Development Hours (PDH) Certificates. Copyright Materials

Builders Risk - Fire Prevention Inspection Checklist

Inspection and Testing of Water-Based Systems

Renovation Program. Renovation Program GENERAL

Report on First Revisions with Statement June 2014 NFPA 101

Agency for Health Care Administration

FIRE/SMOKE BARRIER FUNDAMENTALS

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

FIRE SAFETY AND PREVENTION POLICY

*HB0217* H.B. 217 H.B STATE FIRE CODE ACT AMENDMENTS. LEGISLATIVE GENERAL COUNSEL 6 Approved for Filing: C.R. Gilbert :11 PM 6

Safe Operating Procedure

Fire Sprinkler Submittal Requirements and Acceptance Testing

False Sense of Security???

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Fire Prevention Plan Program

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

NFPA 96, 2017 REVIEW SUMMARY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

1. Add a new paragraph as follows:

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

GUILFORD COUNTY SCHOOLS

Compliance w/ the 2012 Life Safety Code

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

SPILL PREVENTION AND RESPONSE PLAN

esfr pendent sprinkler vk510 (k25.2)

Cold weather regions where temperatures can fall below freezing present a threat to any building housing water-filled systems.

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

Life Safety Codes for Assisted Living Facilities

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

Safety Policy and Procedure

User s Information Manual Models: 45, ,000 Btu/hr

EC 5.10 FIRE PREVENTION MANAGEMENT

Manufacturing safety solutions

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Measures (ILSM) Process

Risk Management Services

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Procedure DESCRIPTION/OVERVIEW

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

Schools and the Fire Code A Partnership for Safety

Design & Construction Standards, Revised January

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Flammable and Combustible Liquids: Storage and Handling

Agency for Health Care Administration

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

Fire Prevention Plan. California State University, Chico

Iowa (2) Delete section and insert in lieu thereof the following new section:

ATTACHMENT B FIRE CODE REQUIREMENTS FOR EXHIBITS AND SPECIAL EVENTS

Slide 1. Slide 2 Instructor. Slide 3. NFPA 25 The Owner s Manual. Roles & Responsibilities DISCLAIMER

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

FHCA 2014 Annual Conference & Trade Show

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)

Combination Cooling/Gas Heat Package Units

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Transcription:

NFPA 25: STANDARD FOR THE INSPECTION, TESTING, AND MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS William E. Koffel, P.E., FSFPE President Koffel Associates, Inc. www.koffel.com wkoffel@koffel.com Expertly Engineering Safety From Fire OBJECTIVE Provide an overview of the inspection, testing, and maintenance requirements for Automatic sprinkler systems Related systems and equipment such as fire pumps Related systems and equipment such as fire pumps Emphasize differences between current editions of NFPA standards and those referenced by TJC Proprietary Presentation by Koffel Associates, Inc. 1

INSPECTION, TESTING, AND MAINTENANCE OF FIRE PROTECTION SYSTEMS THE OWNER S RESPONSIBILITY The owner is responsible for all inspection, testing, and maintenance procedures BE CAREFUL WITH YOUR CONTRACT LANGUAGE The owner may delegate the authority for the inspection, testing, and maintenance of the fire protection systems. The designated representative must comply with all requirements identified for the owner. QUALIFICATIONS (PER NFPA 72) Service personnel shall be qualified Qualifications may include: Factory trained and certified for the make/model being serviced National certification approved by AHJ Registered or licensed by AHJ Employed by listed service company Provide evidence of qualifications to AHJ Proprietary Presentation by Koffel Associates, Inc. 2

THE OWNER S RESPONSIBILITY The owner is responsible for all inspection, testing, and maintenance procedures BE CAREFUL WITH YOUR CONTRACT LANGUAGE The owner may delegate the authority for the inspection, testing, and maintenance of the fire protection systems. The designated representative must comply with all requirements identified for the owner. THE OWNER S RESPONSIBILITY Notify proper entities AHJ, fire department, insurance carrier Correct deficiencies Analyze changes that t may impact the system Maintain records Available to AHJ upon request ITM RECORDS Retain all records until one year after the next test Records must be promptly provided to the AHJ upon request Proprietary Presentation by Koffel Associates, Inc. 3

ITM RECORDS For hospitals that accreditation for deemed status purposes, documentation of ITM procedures for fire protection systems shall include Name of activity Date of activity Required frequency Name of person performing activity NFPA Standard referenced Results of the activity EC 02.03.05 revised effective July 1, 2011 NFPA 25 SCOPE 1.1.3 This standard addresses the operating condition of fire protection systems... 1131 1.1.3.1 This standard does not require the inspector to verify the adequacy of the design of the system. IMPAIRMENTS Where an impairment is to last for more than 10 hours in a 24 hour period one of the following must be done: Evacuation of the affected area Fire Watch Temporary water supply Implement an approved fire control program Note that NFPA 101 until the 2012 Edition referred to fours hours in a 24 hour period Proprietary Presentation by Koffel Associates, Inc. 4

Table 5.1.1.2 13 Proprietary Presentation by Koffel Associates, Inc. 5

SPRINKLERS ARE INSPECTED FOR: Leakage Corrosion Paint Loading Orientation Empty bulbs Clearance below sprinkler (such as storage) 18 Proprietary Presentation by Koffel Associates, Inc. 6

19 SPRINKLER TESTING Standard response sprinklers tested or replaced at 50 years and 10 years thereafter Fast-response sprinklers tested or replaced at 20 years and 10 years thereafter Dry sprinklers tested or replaced at 10 years and 10 years thereafter Sprinklers exposed to harsh environment tested at 5 year intervals SPRINKLER TESTING Test includes 4 sprinklers or 1 percent of sample area whichever is greater If one sprinkler fails then all sprinklers in sample are must be replaced Proprietary Presentation by Koffel Associates, Inc. 7

CONTROL VALVES WATERFLOW ALARM TESTS ANTIFREEZE SOLUTIONS Tested annually The Concentration of solution must be limited to the minimum that is necessary to protect for the lowest anticipated temperature Proprietary Presentation by Koffel Associates, Inc. 8

Traditionally HISTORICAL PERSPECTIVE Anti-freeze used to protect sprinkler systems installed in small areas where adequate heat is not provided o Previous editions of NFPA 13 contained an Annex note indicating that anti-freeze not likely to be economical in excess of 40 gallon capacity of piping system Other solutions include: o Dry-pipe sprinkler systems o Preaction sprinkler systems o Heat trace systems NEW TECHNOLOGIES FIRE INCIDENTS August 18, 2009 Truckhee, CA Cooking fire in kitchen of occupied apartment Cooking onions in oil Proprietary Presentation by Koffel Associates, Inc. 9

FIRE INCIDENTS Truckhee, CA (cont) One adult fatality, one adult severely injured, three children with minor injuries Fire and explosion resulting in 8 sprinklers in the unit operating Glass was blown 86 ft across the parking lot Bathroom door was separated approx 3 inches from the frame 72% antifreeze, 28% water in system. Should have been 50/50 Propylene Glycol MSDS INFORMATION Heat from fire can generate flammable vapor when mixed with air and exposed to ignition source. Vapors can explode if confined. Vapors may travel long distances along ground before igniting/flashing back to vapor source. Fine sprays/mist may be combustible at temperatures below normal flash point (211F- 228F) Propylene Glycol MSDS INFORMATION Do not handle near heat, sparks, or open flame. Aqueous solutions greater than 22% by weight, if heated sufficiently, will produce flammable vapors. ENVIROGUARD Proprietary Presentation by Koffel Associates, Inc. 10

UL Tests LITERATURE REVIEW Under certain conditions a large-scale ignition is possible from the discharge of a sprinkler system containing solutions of 70% glycerin or 60% propylene glycol in water onto certain ignition sources Dependent on the o Characteristics of the fuel source o Spray distribution pattern o System pressure o Type of sprinkler o Location of the fire relative to the sprinkler o Concentration of the antifreeze solution in the mixture. NOTE: NFPA 13 has permitted 50% glycerin and 60% propylene glycol LITERATURE REVIEW Fire Protection Research Foundation Test Program Concentrations of propylene glycol > 40% by volume and concentrations of glycerin > 50% by volume have the potential to ignite when discharged through automatic sprinklers. Consideration should be given to an appropriate safety factor for concentrations of antifreeze solutions that are permitted by future editions of NFPA 13. The use of solutions of di-ethylene glycol and ethylene glycol in home fire sprinkler systems should also be limited. NFPA RESPONSE Tentative Interim Amendments issued for NFPA 13, NFPA 13R, NFPA 13D Effective date: August 25, 2010 Antifreeze not permitted within dwelling units Antifreeze not permitted within dwelling units Considered to be an initial response Proprietary Presentation by Koffel Associates, Inc. 11

NFPA RESPONSE TIA s issued for NFPA 13, NFPA 13R, NFPA 13D Effective date: March 21, 2011 Premixed antifreeze solutions o By manufacturer to ensure proper suspension Permitted concentrations reduced o Special provisions for ESFR systems o Note still exceed 22% per at least one MSDS o NFPA 13D (and NFPA 25) permit higher concentrations for existing TIA issued for NFPA 25 NFPA RESPONSE Effective date: March 21, 2011 Drain anti-freeze if properties undetermined Permitted concentrations reduced o Existing SOLUTIONS permitted at higher concentrations Test details o Size of system o Drops RECENT FPRF RESEARCH Proprietary Presentation by Koffel Associates, Inc. 12

NFPA RESPONSE NFPA 13, 13R, and 13D Restriction on all new antifreeze systems unless solution is listed for use in a fire protection system Current submission to UL for a salt water based, with corrosion inhibitor, being evaluated Existing systems NFPA 25 TIA (Aug 2012) Reduce concentrations further unless a risk analysis has been performed Other options remain possible Dry pipe sprinkler systems Pre-action sprinkler systems Heat-trace Insulation Risk analysis for nonoccupied areas o Considered by the NFPA 25 Technical Committee when processing the TIA s SOLUTIONS 39 Proprietary Presentation by Koffel Associates, Inc. 13

MAIN DRAIN TEST 42 Proprietary Presentation by Koffel Associates, Inc. 14

FIRE PUMPS CHURN TEST ANNUAL FLOW TEST Proprietary Presentation by Koffel Associates, Inc. 15

46 PUMP PERFORMANCE INSPECTION AND EXAMINATION Inspection Conducted at specified intervals Covers two points in the system (end of one main and sprinkler on one branch line) Examination Conducted when certain conditions exist Covers four points in the system (valve, riser, cross main, branch line) Proprietary Presentation by Koffel Associates, Inc. 16

SOURCES OF OBSTRUCTIONS SOURCES OF OBSTRUCTIONS SOURCES OF OBSTRUCTIONS Proprietary Presentation by Koffel Associates, Inc. 17

MIC COMPONENT ACTION REQUIREMENTS Required for any component that is adjusted, repaired, reconditioned, or replaced Main drain test is required if any system control valve or other upstream valve was operated It is not intended that a design review be conducted ANNEX E 2011 EDITION Classifies how critical the deficient condition is Is it an impairment? How critical is the deficiency? Proprietary Presentation by Koffel Associates, Inc. 18

QUESTIONS AND DISCUSSION Proprietary Presentation by Koffel Associates, Inc. 19