Maestro Occupancy sensing switch

Similar documents
Maestro Occupancy sensing switch

Maestro Occupancy Sensing Switch

Maestro Occupancy sensing switch

Maestro Occupancy Sensing Switch

Dimmer/Switch with Occupancy and Vacancy Sensor

Maestro Occupancy Sensor C L Dimmer

Maestro Dual-Circuit Occupancy Sensing Switch

Lutron Sensor Solutions. Lutron energy-saving light controls for your home or office. simple. affordable. energy-saving.

ViveTM Basic Packages

Maestro 0 10 V Dimmer Sensor

LED Control Solutions. Smooth, flicker-free dimming for every application

simplicity. convenience. control.

Maestro Wireless dimmers, switches and sensors

Maestro Dimmer - Satin Finish, Incandescent/Halogen, Single-Pole, Clamshell Packaging, 120V/600W In Biscuit

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Lutron C L dimmers. Solve the challenges of light bulb compatibility. Works with:

Lutron C L dimmers. Solve the challenges of light bulb compatibility COMING SOON. Nova T* C L. Works with:

LED Control Solutions

Wireless Wall-Mount Sensor

Quick Install Energy Solutions

Wireless Wall-Mount Sensor

Quick Install Energy Solutions Featuring Energi TriPak

Native Lighting Control

lighting control Simple, scalable, wireless Transform existing buildings with wireless lighting controls Wireless controls and sensors

Vive PowPak Fixture Controls

Wireless Wall-Mount Sensor

GRAFIK T Controls GRAFIK T

GRAFIK TTM Controls GRAFIK TTM. Wallbox Controls

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX)

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

new GRAFIK Eye QS Customisable preset light and blind control system

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

SPECIFICATION SUBMITTAL

A complete drapery track offering to meet all of your application needs

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

HomeWorks QS Architectural RF GRAFIK T Local Controls

Infrared Ceiling Mount Sensor

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Code Compliance Commercial Application Guide

Installation Instructions

Residential Occupancy & Vacancy Sensors

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

ENERGY EFFICIENCY EXPERTS

Infrared Wall Mount Occupancy Sensor

Save Energy With Campus-Wide Solutions

Wireless Plug Load Control

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

RA2 Select. Whole home lighting control made simple. Lutron.com/ra2select. Lutron Electronics Co., Inc Suter Road Coopersburg, PA

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Infrared Ceiling Mount Sensor

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

600 Watt Dimmer Install Guide

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Interior Control Solutions

PRELIMINARY COPY. RadioRA 2. Save energy with wireless total home control from Lutron

Mini Product Guide.

Versatile wall switch sensors maximize payback and simplify code compliance

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Ever evolving energy code requirements and the large demand for energy

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

RadioRA 2. Save energy with wireless total home control from Lutron

Technical Application Guide

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Save Energy with Unparalleled Total Home Control

Never forget to turn the lights off again. Motion Sensors

LUTRON 0-10V LIGHT CONTROLS MINIMUM ADVERTISED PRICE POLICY

INSTALLATION AND OPERATIONS MANUAL FOR MODELS: ITSDU / ITSHDFU / ITSEBU

RadioRA 2. Wireless total home control

Light control solutions

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

Volume 1: Basic devices and single-space systems

Applied Lighting Controls

SPECIFICATION SUBMITTAL

VESICA LINEAR SUSPENDED VES L

Quick Install Energy Solutions Featuring Energi TriPak

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

RadioRA 2. Save energy with wireless total home control from Lutron

Vive wireless hub. BACnet Integration. Demand Response

0ACDT2000MV Ultasonic/Infared Occ Sensor

ehub Application Note Boardrooms

HomeWorks QS Palladiom HVAC Solution

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

ANSI/ASHRAE/IES

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

Installation Instructions

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

RadioRA 2. Save energy with wireless total home control from Lutron

National Grid Small Business Program Rebate Manual

Abella Digital Fade Dimmer

Transcription:

Maestro switch The Lutron Maestro switch combines a Maestro switch with a passive infrared occupancy or vacancy sensor. The sensor detects the heat from occupants moving within an area to determine whether the space is occupied. Based on the feedback from the sensor, the occupancy will adjust the load accordingly. Features XCTTM Technology for fine motion detection 2 2 2 2 motion coverage sensitivity adjustment and fan. Models available 369666c 1 09.11.12 1

Specifications Regulatory Approvals Power ~ ~ Key Design Features TM Technology for fine motion detection. patented Softswitch. Environment Indoor use only. Warranty information, please visit www.lutron.com/ TechnicalDocumentLibrary/_Warranty.pdf Advanced Features 369666c 2 09.11.12 Switching power curve. timing. arcing at mechanical contacts when loads are inductive sources. XCTTM Technology detection ensures that the lights stay on while the room is occupied, and that the sensor does not turn on falsely when there is no occupancy in the www.lutron.com/ TechnicalDocumentLibrary/white%20paper%20 XCT%204-23-09%20B.pdf Additional Information see Lutron P/N 048440. dimmer models, please see Lutron P/N 369270. locations, please see Lutron P/N 048435. www.lutron.com/ occvacsensors 1 Selection Matrix 2

Custom Settings Ambient Light Detection Lights turn on only if natural light in room is low. the user s preference. switch does not turn on when there is not enough natural light, press interaction will teach the switch your preferred setting. Operation Timeout Options Additional Features Sensitivity Options 369666c 3 09.11.12 Manual Off-While-Occupied Options Additional Features turned off, the switch will not turn the lights back on automatically while the room is occupied. returns to normal operation after the timeout or classrooms while viewing presentations. This wants the lights to turn on upon entering and the lights to turn off when the room is vacant. Auto-ON Options automatically turned off, during which the lights will automatically turn back on in response to motion. This grace period is provided as a safety and convenience feature in the event that the lights turn off while the room is still occupied, so that the user does not need to manually turn lights must be manually turned on. 3

Selection Matrix 369666c 4 09.11.12 Vacancy only 2 (Title 24 compliant) Single-pole only Works with standard mechanical 3-way switch 3 Works with companion switch 3, 4 All lighting loads (120 V~ only) All lighting loads (120 277 V~ only) Fan (120 V~) Light + Fan (120 V~) Neutral wire required Ground wire required for functionality Minimum load required Relevant wiring diagram Model Number 1 MS-OPS2-XX MS-OPS5M-XX MS-OPS6M2-DV-XX MS-OPS6M2N-DV-XX UMS-OPS6M-DV-XX 5 MS-VPS2-XX MS-VPS5M-XX MS-VPS6M2-DV-XX MS-VPS6M2N-DV-XX UMS-VPS6M-DV-XX 5 Single-pole / 3-way capability Max current rating Off-state power 1 2 3 4 5 4

Additional Features 369666c 5 09.11.12 Crush/tamper-resistant lens Ambient light detection Switching XCTTM technology Manual off-while-occupied default setting Default timeout (minutes) Model Number 1 MS-OPS2-XX Smart Standard MS-OPS5M-XX Smart Standard MS-OPS6M2-DV-XX Smart MS-OPS6M2N-DV-XX Smart UMS-OPS6M-DV-XX Softswitch MS-VPS2-XX Smart Standard MS-VPS5M-XX Smart Standard MS-VPS6M2-DV-XX Smart MS-VPS6M2N-DV-XX Smart UMS-VPS6M-DV-XX Softswitch 1 5

Sensing Switch Placement and Operation 369666c 6 09.11.12 switch must have an unobstructed view of the room. switch to detect occupants. Definitions Major motion: movement of a person entering or passing through an area. Minor motion: NEMA WD7 Coverage Horizontal Beam Diagram 2 2 2 2 Vertical Beam Diagram 6

Dimensions Front View Side View 369666c 7 09.11.12 11 16 2 15 16 1 8 Ganging Each control has inside fins removed Middle of Gang control has all fins removed 7

Mounting 369666c 8 09.11.12 Mounting screws Sensing Switch Operation Status LED Indicates load status; glows softly as night light when light is off Tapswitch Tapswitch Lens LED of custom settings and in the Test mode. LED acknowledge motion when Lens FASSTM Service Switch IMPORTANT NOTICE TM Front Accessible Service Switch To service load, remove power by pulling the TM TM switch back in fully to restore power to the control. 8

Wiring Diagrams Wiring Diagram 1 Single Location Installation (120 V~) Wiring Diagram 2 Single Location Installation (120 V~) 1 369666c 9 09.11.12 ~ ~ Wiring Diagram 3 3-way Installation with Standard Mechanical Switch (120 V~) 2, 3 Standard mechanical switch switch color screw ~ Jumper wire screw OR Standard mechanical switch color screw ~ screw Jumper wire 1 2 3 Continued on next page... 9

Wiring Diagrams (continued) Wiring Diagram 4 3-way Installation with Standard Mechanical Switch (277 V~) Standard mechanical switch switch 1, 2, 3 369666c 10 09.11.12 color screw ~ Jumper wire screw OR Standard mechanical switch color screw Jumper wire ~ screw Wiring Diagram 5 Multi-Location Installation (120 V~) 1, 2, 4 MA-AS or MSC-AS MA-AS or MSC-AS switch 4 Brass Brass ~ 1 2 3 ~~ 4 switch can be installed in any location. Continued on next page... 10

Wiring Diagrams (continued) Wiring Diagram 6 Multi-Location Installation (277 V~) 1, 2, 3, 4 MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 switch 3 369666c 11 09.11.12 ~ 1 2 3 switch can be installed in any location. 4 ~~ Continued on next page... 11

Wiring Diagrams (continued) Wiring Diagram 7 Single Location Installation (120-277 V~) 1, 2 369666c 12 09.11.12 ~ Wiring Diagram 8 3-way Installation with Standard Mechanical Switch (120 V~) 3, 4 Standard mechanical switch switch color screw ~ Jumper wire screw OR Standard mechanical switch color screw ~ screw Jumper wire 1 NOT 2 ~~ 3 4 Continued on next page... 12

Wiring Diagrams (continued) Wiring Diagram 9 3-way Installation with Standard Mechanical Switch (277 V~) Standard mechanical switch switch 1, 2, 3 369666c 13 09.11.12 color screw ~ Jumper wire screw OR Standard mechanical switch color screw ~ screw Jumper wire 1 2 3 ~~ Continued on next page... 13

Wiring Diagrams (continued) Wiring Diagram 10 Multi-Location Installation (120 V~) 1, 2, 3 MA-AS or MSC-AS MA-AS or MSC-AS switch 3 369666c 14 09.11.12 Brass Brass ~ Wiring Diagram 11 Multi-Location Installation (277 V~) 1, 2, 3, 4 MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 switch 3 ~ 1 2 3 switch can be installed in any location. 4 ~~ Continued on next page... 14

Wiring Diagrams (continued) Wiring Diagram 12 Single Location Installation 1, 2 369666c 15 09.11.12 Wiring Diagram 13 Single Location Installation with Shunt Capacitor 1, 2, 3 ~ ~ Optional Shunt Capacitor 2 Wiring Diagram 14 Multi-Location Installation (120 V~) 1, 4, 5, 6 MA-AS or MSC-AS MA-AS or MSC-AS switch 6 Brass Brass ~ Wiring Diagram 15 Multi-Location Installation (277 V~) 1, 2, 3, 4, 5, 6 MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 switch 6 ~ 1 2 ~~ 3 4 5 6 switch can be installed in any location. Continued on next page... 15

Wiring Diagrams (continued) Wiring Diagram 16 Multi-Location Installation with Shunt Capacitor (120 V~) MA-AS or MSC-AS MA-AS or MSC-AS 1, 2, 3, 4 switch 4 369666c 16 09.11.12 Brass Brass Optional ~ Shunt Capacitor Wiring Diagram 17 Multi-Location Installation with Shunt Capacitor (277 V~) MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 1, 2, 3, 4, 5 4 Optional ~ Shunt Capacitor 1 2 3 4 switch can be installed in any location. 5 ~~ 16

Colors and Finishes Gloss Finishes Satin Finishes 369666c 17 09.11.12 Ivory Merlot MR TQ Taupe Biscuit BI Snow Brown BR Midnight Sienna SI Terracotta TC BL stone Mocha Stone MS Stone ST Limestone LS 17