Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Similar documents
Series A28 Two stage Thermostats. Feature and Benefits

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

F261 Series Fluid Flow Switches

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

P266 Series Single-Phase Condenser Fan Speed Control

Pressure switch KPU. Data sheet

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

TM-3100 Series Room Temperature Sensor

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

PumpSaver ISS-105 IS Super Cell Installation Guide

DB5 Intrinsically Safe Sounder Type DB-5

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

ER52 - Evaporator Controller

Inductive slot sensor

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

EU DECLARATION OF CONFORMITY

MR3CCUHV Temperature/Defrost Control

y Small dimensions. Easy to install in refrigerated counters or cold rooms

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Rosemount 3490 Series

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

ER65 - Mini Rack Controller Electronic Refrigeration Line

4) Intrinsic Safety Certification

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

BA488CF Intrinsically safe Panel mounting Fieldbus Display

SET-2000 Oil/Sludge 12 VDC

FDOOT241-A9-Ex Multisensor fire detector

Fire Alarm System Accessories

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Declaration of conformity

Annubar Flowmeter Series

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

PROFIBUS-PA Display RID 261 PROFIBUS-PA

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

IECEx Certificate of Conformity

Certificate of Compliance

Supplementary Installation and Operating Instructions. Category II2G

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Certificate of Compliance

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

Model 144H. Product Data Sheet , Rev DB February Content

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications

Technical Data. Dimensions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

E2S Datasheet v10a

Temperature, Mechanical

Rosemount 752 Fieldbus Remote Indicator

M7100 Pressure Transducer

Description. Applications

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Frost Units for air temperature monitoring

OOH740-A9-Ex Multi-sensor fire detector

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

High Pressure Conductivity Monitor

Mark* VIe and Mark VIeS Control Systems Equipment in Hazardous Locations (HazLoc) Instruction Guide

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

AND INSTALLATION MANUAL

SET-2000 Hi Level/Oil

General Specifications

U5600. Wireless Pressure Transducer SPECIFICATIONS

Mobrey MCU900 Series Universal Control Unit

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

IECEx Certificate of Conformity

Exp, pressurized systems

W43A Humidistat. Features and Benefits

Tank Gauging System Special Safety Instruction

Certificate of Compliance

SET Installation and Operating Instructions. Level switch for one sensor

OPTIBAR DP 7060 Supplementary Instructions

Technical Data. Dimensions

Circulation Heaters Selection Guidelines

ACT2-CS Convenience Store Controller

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034)

Transcription:

Series P77 Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Product bulletin These pressure controls are designed for use in a variety of applications involving refrigeration high or low pressure. Models supplied have a "whole range" design, enabling them to be used with refrigerants R22, R134A, R404A, R410A, R744 (CO 2 ), R717 (NH3), R290, R600 natural HC refrigerants CO 2 and all other non-corrosive refrigerants which are within the operating range of the control. They may also be used for other high or low pressure applications such as air, water etc. Models which can be used with ammonia are included in the program. Also models tested and approved to PED 2014/68/EU Cat. IV (supersedes DIN and TUV approval) are included in the program. The P77 series pressure controls may be used for control functions or limit functions, depending on model number. All models are provided with alarm contacts. All standard models have phosphor bronze bellows and brass pressure connections. Models for use with ammonia (NH3) are provided with stainless steel bellows and connectors. Devices conforming to PED 2014/68/EU Cat. IV (HP models) have the fail-safe function with double bellows. Their IP54 classification means that these pressure controls are suitable for almost all applications. P77 Series Controls for Hazardous Location Applications use a low energy signal from inside an explosive zone on commercial refrigeration and airconditioning applications. The controls have special dry circuit switches with gold-plated contacts for improved contact characteristics required in low voltage, low current circuits. They are designed to operate in Group II, Zone 2 (per the ATEX Directive) environments. Class I, Division 2, Group D (per NFPA 70 and CSA C22.2) environments. Gold plated contacts For low current applications custom models with gold plated contacts may be requested. Contact your salesman. Generous wiring space Easy wiring and maintenance Splash-proof enclosure (IP54) Can be used for indoor/outdoor applications SPDT contacts are provided as standard on single pressure controls Can be wired for alarm functions Trip-free manual reset Override is not possible in the control function ATEX approved For use with flammable refrigerants (R290, R600). Meets 2014/34/EU ATEX directive.

Electrical connection hazardous application Use only cables and cable entries approved for propane applications. Do not allow cables to come into contact with sharp edges. Install cables with adequate stress relief to avoid pulling at the terminal. EX certified Zener barrier or suitable associated apparatus Signal Hazardous Locations Class I, Division 2, Group D Ex ic IIB T6 Gc -20 C Ta 55 C Non-Hazardous Locations Entity parameters (P77 pressure control parameters) Maximum switch loads Pi max (P max) 1 W Ui Max (V max) 30 V Ii Max (I max) 0.1 A Ci max 0.5 nf Li max 0.2 μh Intrinsic safety protection method Selected associated apparatus providing output entity parameters must be third party listed for the application, and have intrinsically safe entity parameters conforming with table below. Intrinsically safe entity parameters for the associated apparatus Zener barrier P77 pressure control or suitable associated apparatus Ui Max (V max) Voc or Vt (or Uo) Ii Max (I max) Isc or It (or Io) Pi max (P max) Po Ci + Ccable Ca (or Co) Li + Lcable La (or Lo) 2

IMPORTANT: The controls are intended to control equipment under normal operating conditions. Where failure or malfunctioning of the controls could lead to an abnormal operating condition that could cause personal injury or damage to the equipment or other property, other devices (limit or safety controls) or systems (alarm or supervisory systems) intended to warn of or protect against failure or malfunctioning of the controls must be incorporated into and maintained as part of the control system. Contact functions (see also Type number selection tables) Line ~ max. 20 A A C B M Type number matrix P77AAA P77BCA P77BEA P77AAW P77BEB P77BES P77BCB P77XAAW Mounting Automatic reset Open low - manual reset Open high - manual reset HP or LP Limit (autoreset) HP conforming to PED 2014/68/EU HP Limit (Manual Reset) conforming to PED 2014/68/EU HP Safety Limit (Manual Reset) conforming to PED 2014/68/EU LP Limit (Manual Reset) including lockplate assy HP or LP Limit (autoreset) HP conforming to PED 2014/68/EU HP or LP conforming to ATEX 2014/34/EU Mounting can easily be done with mounting bracket 271-51L (order separately) or directly on a surface. Mounting holes 4,5 mm Ø and M4 holes are provided. Figure 1: A - C open on pressure decrease C A Line ~ B max. 20 A M Figure 2: A - B open on pressure increase B A Line ~ C max. 20 A M Adjustment Adjustment of range and differential can be done by turning the hexagonal range screw and differential screw. Manual reset models have a range screw only. The adjustment screw can also be locked by a lock plate accessory (KIT023N600). The lock plate is included with those devices which are conform to PED 2014/68/EU Cat. IV. On all models the scale indicates the high switch point (Except type P77BCA, P77BCB, here the scale indicates the low (cut-out) switch point). The low switch point can be derived by deducting the differential value from the high switch point. Figure 3: A - C open on pressure increase Optional construction note If your requirements are not in the type number selection table, then please contact your Johnson Controls representative. Repair and replacement Repair is not possible. In case of an improperly functioning control, please check with your nearest supplier. When contacting the supplier for a replacement you should state the type/model number of the control. This number can be found on the data plate or cover label. 3

Type number selection Pressure controls for non-corrosive refrigerants code Style 5 Style 28 Style 30 Range Diff. Contact function (Figure) Max bellows pressure Ind. pack. Bulkpack Bulkpack Ind. pack. -9300-9320 -9800-9400 -0.5 to 7 0.6 to 3 1 22-9301 --- --- --- -0.2 to 10 1 to 4.5 1 15 P77AAA -9302 --- --- --- -0.3 to 2 0.4 to 1.5 1 4-9350 -9370-9850 -9450 3 to 30 3 to 12 2 33-9351 -9371 --- -9451 3.5 to 21 2.1 to 5.5 2 30 P77BCA -9300-9320 --- -9400-0.5 to 7 Man. res.** 1 22 P77BEA -9350-9370 --- -9450 3 to 30 Man. res:* 3 33 * Resetable at 3 bar below cut-out point ** Resetable at 0.5 bar above cut-out point Pressure controls for ammonia and non-corrosive refrigerants Style 15 Range Diff. Contact function Max bellows code Ind. pack. Bulkpack (Figure) pressure P77AAA -9700 --- -0.5 to 7 0.6 to 3 1 14 P77AAA -9750 --- 3 to 30 3.5 to 12 2 33 P77BCA -9700 --- -0.5 to 7 Man res.** 1 14 P77BEA -9750 --- 3 to 30 Man. res.* 3 33 * Resetable at 3 bar below cut-out point ** Resetable at 0.5 bar above cut-out point Note: 100 kpa = 1 bar 14.5 psi Pressure controls for non-corrosive refrigerants (Pressure limiter, pressure cut-out, safety pressure cut-out, including lockplate assy) code Style 5 Style 28 Range Diff. Contact function (Figure) Max bellows pressure Approved according to PED 2014/68/EU Cat. IV Ind. pack. Bulkpack Ind. pack. -9300-9320 -9800-0.5 to 7 0.6 to 3 1 22 --- P77AAW -9350-9370 -9850 3 to 30 3.5 to 12 2 33-9355 --- -9855 3 to 42 4 to 12 2 47.6 P77BCB -9300-9320 -9800-0.5 to 7 Man. res. ** 1 22 --- P77BEB -9350-9370 -9850 3 to 30 Man. res. * 3 33-9355 --- -9855 3 to 42 Man. res. *** 3 47.6 P77BES -9350-9370 -9850 3 to 30 Man. res. * 3 33 * Resetable at 3.5 bar below cut-out point ** Resetable at 0.5 bar above cut-out point *** Resetable at 5 bar below cut-out point 4

Type number selection Pressure controls for ammonia and non-corrosive refrigerants, (Pressure limiter, pressure cut-out, safety pressure cut-out, including lockplate assy) code Style 15 Range Diff. Contact function (Figure) Max bellows pressure Approved according to PED 2014/68/EU Cat. IV Ind. pack. Bulkpack P77AAW -9700 --- -0.5 to 7 0.6 to 3 1 14 --- -9750 --- 3 to 30 3.5 to 12 2 33 P77BEB -9750 --- 3 to 30 Man. res.* 3 33 P77BES -9750 --- 3 to 30 Man. res.* 3 33 * Resetable at 3.5 bar below cut-out point Pressure controls for Hazardous Location Application and non-corrosive refrigerants (Pressure limiter, including lockplate assy) code P77XAAW Style 28 Contact function (Figure) Range Differential Pressure connection Maximum bellows pressure Approved according to PED 2014/68/EU Cat. IV Ind. pack. Bulkpack -18000C -18000D 1-0.5 to 7 0.6 to 3 6 mm diam. 22 --- -18500C -18500D 2 3 to 30 3.5 to 12 copper tube 33 Pressure connection Style 5 Style 15 Style 28 Style 30 Male connector 7/16-20 UNF for 1/4 6 mm flare nut. Female connector 1/4-18 NPT Braze connection 6 mm ODM Braze connection 1/4 ODF 5

Accessories (optional) Ordering Codes Application Description CNR003N001R For 6 mm copper or steel tubing Fit into style 15 pressure connectors CNR003N002R For 8 mm copper or steel tubing Mounting bracket Order number 271-51L 90 cm Capillary with (2) flare nuts (1/4 SAE) Order number SEC002N600 Locking kit Order number KIT023N600 6

Dimensions in mm (Style 5 and style 15) 53 25 70 9 48.5 1 8 16.5 13 5.5 2 55 25 80 3 10 4 22.5 88 61 23.5 1.5 26 21.5 53 5 6 1. Lock plate (if applied) 2. Two mounting holes Ø 4.5 mm (knock out) 3. Four mounting holes Ø M4 (back side) 4. Power element: Style 5: 7/16-20 UNF male (shown) Style 15: 1/4-18 NPT female 5. Reset button 7

Dimensions in mm (Style 28 and style 30) 53 70 9 25 48.5 1 8 16.5 13 5.5 2 55 25 80 3 10 4 110 88 61 23.5 1.5 26 21.5 53 5 6 1. Lock plate (if applied) 2. Two mounting holes Ø 4.5 mm (knock out) 3. Four mounting holes Ø M4 (back side) 4. Power element: Style 28: Braze connection 6 mm ODM (shown) Style 30: Braze connection 1/4 ODF 5. Reset button 8

Technical specifications Pressure connections Style 5, 15, 28, 30 (see drawings) Operating ranges and diff. See "Type number selection" tables Adjustments See "Type number selection" tables Ambient temperature limit -50 to +55 C (+70 C max. duration two hours) -20 to +55 C for PED approved models Electrical ratings 400 Vac 16(10) A 220 Vdc 12 W (pilot duty only) P77X model: 30 V / 1W Pulsation plug Fitted into all HP bellows on models with range 3.5 to 21 bar and up Locking plate and screw To lock and seal range and/or differential screw. Standard on types P77AAW, BEB, BES and BCB. Optional on all other types (quantity orders only) Protection class IP54 Material Case and cover Weatherproof aluminium (die-cast) Contact unit Large silver nickel contact surface Accessories (see pag. 6) Mounting bracket Compression coupling 90 cm capillary with two flare nuts Shipping weight ind. pack 0.5 kg. -93xx Ind. overpack 36 pcs. (19 kg) -97xx Bulk pack 35 pcs. (18 kg) -94xx -98xx -18xx Ind. overpack 16 pcs. (9 kg) Compliance Europe Johnson Controls declares that these products are in compliance with the essential requirements and other relevant provisions of the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. Pressure Equipment Directive 2014/68/EU. ATEX: DEMKO 16 ATEX 1734 Directive: EN 60079-0 EN 60079-11 Australia and New Zealand RCM Mark, Australia/NZ Emissions Compliant The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. Building Efficiency Headquarters: Milwaukee, Wisconsin, USA Branch Officies: Principal Cities World-wide Metasys and Johnson Controls are registered trademarks of Johnson Controls. All other marks herein are the marks of their respective owners. Copyright 2017 Johnson Controls. All rights reserved. Any unauthorized use or copying is strictly prohibited. www.johnsoncontrols.com