ComfortSense 7500 Commercial Thermostat. User Guide

Similar documents
ComfortSense 7500 Thermostat. User Guide

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

Evolution Control. Zone Control Homeowner s Guide

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Installation and Setup Guide

User s Manual

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

Owner s Manual ENERGY EFFICIENT, AT A TOUCH OF A BUTTON TSTPRH01, CÔRR 7 TSTWRH01 CÔRR 7C RESIDENTIAL THERMOSTATS. Côrr 7 Series

CONTROLS /08 Supersedes 05/08

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

USER S INFORMATION MANUAL

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

ATC32U03 igate Communicating, Programmable Thermostat

ATC32U01 igate Communicating, Programmable Thermostat

4 Wiring Brochure Wiring and

Homeowner s Guide / 1

81M26 81M27 81M28. User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS

PROGRAMMING AND APPLICATION GUIDE IMPORTANT. ComfortSense 7000 Series. CONTROLS /08 Supersedes 05/08. Shipping and Packing List

icomfort E30 Smart Thermostat User Guide /2018 Supersedes Lennox Industries Inc. Dallas, Texas, USA

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

icomfort S30 User Guide

- Data Brochure tekmarnet 4 Thermostat 542e

icomfort M30 Smart Thermostat User Guide

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

Owner s Manual. Part Number 33CSCPACHP-01

ComfortSense Model L7742U Thermostat. Display Fields & Touch Screen Points. Features. Description

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

PROGRAMMING AND APPLICATION GUIDE IMPORTANT IMPORTANT. ComfortSense 7000 Series. CONTROLS /09 Supersedes 04/09. Shipping and Packing List

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

Commercial Touchscreen Thermostat

T855S. Caution. Page. Table of Contents Table of Contents Thermostat Operation Thermostat Quick Reference Programming Features Warranty Information

TP-PHP01-A,TP-PAC01-A &TP- PRH01- B Performance Series Programmable Thermostat. Owner s Manual

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Owner s Manual. Part Number 33CS250-01

Thermostat TP42H01 User Manual

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

Smart Hub 2.0. icomfort. S30 Ultra Smart Thermostat User Guide /2018 Supersedes Lennox Industries Inc. Dallas, Texas, USA

Safety & Installation Instructions

Wiser Air User Interface Guide. Thermostat

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

OWNER S MANUAL. Part Number P

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

HOMEOWNER S MANUAL. Harmony III Zone Control System. IMPORTANT: Read this instruction manual completely! Retain for future reference.

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

Instruction Guide: Thermostat Operation

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

icomfort E30 Smart Thermostat User Guide

Wireless Thermostat (WTS10) Keypad Operation Guide

Programmable Interactive User Manual

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS

Lyric T6 & T6R Smart Thermostat

HOMEOWNER'S MANUAL WARNING NOTICE. icomfort Wi Fi Thermostat. CONTROLS /2013 Supersedes General

Programmable Touchscreen Thermostats. Read all instructions before proceeding. Store this manual for future reference

User Manual. Universal Programmable Smart Wi-Fi Thermostat. For Systems Up to 3 Heat / 2 Cool with Wireless Humidity Control*

Model: Edge-HC. 1 edge-hc

Operation Guide CT80 ENGLISH

EFFICIENT, AT A TOUCH OF A BUTTON

INSTALLER'S SYSTEM SETUP GUIDE NOTICE

Smart Energy Programmable Thermostat + Energy Monitor. EE542-1Z I User Manual

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

WARNING This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm.

552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14

Read all instructions before proceeding. Store this manual for future reference

Installation and Maintenance Manual IM

9801i 9815i 9820i. User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS. Humidity Sensing

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

OWNER S MANUAL Venstar Inc. 08/07

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

ComfortNet CTK03 Thermostat Instructions Millbrook Apartments #4 Application

VisionPRO Series with RedLINK. User Guide

Installer Guide. WARNING Important Safety Information. 1 Specifications

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Pioneer Z100 Smart Thermostat Operating and Installation Manual

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

Elegance. SMT-700 User manual. Ver

Owner s Manual. Part Number 33CS250-RC

Z100 Pioneer 2 Smart Thermostat Operating and Installation Manual

OPERATING INSTRUCTIONS

DAY/TIME Button: Selects hour, minute and day setting.

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

IDEAL E-NERGY Thermostat Touch type User Manual

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

T600MEP-2 Programmable Economizer Thermostat

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

Safety & Installation Instructions

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

Universal Programmable Wireless Thermostat Kit. See Wireless Setup Guide for Wireless Setup Instructions Read all instructions before proceeding

Zone Perfect Plus. Zoning Systems USER S INFORMATION MANUAL. NOTE TO INSTALLER: This manual must be left with the equipment user.

HEAT COOL. Meets Commercial California Title 24

OWNER S MANUAL. Part Number P RF

Transcription:

ComfortSense 7500 Commercial Thermostat User Guide 507505-02 6/2018 Supersedes 5/2017

Table of Contents Features...2 Home Screen Temperature Indicator...2 Home Screen Information...3 Operating Mode Selection...5 Select Modes... 5 Fan Operation... 6 User Menu Screen...7 Notifications... 7 Reminders... 7 Performance Report... 8 Edit Schedules... 8 User Settings Menu...10 Features The ComfortSense 7500 Series thermostat is an electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. supports commercial package rooftop units smooth set recovery starts system operation early to achieve setpoint at start of program period economizer control dehumidification measurement and control equipment maintenance reminders worry-free memory storage feature menu-driven touch-screen display dehumidification measurement and control Humiditrol EDA capability Home Screen Temperature Indicator 2:31 am thurs occupied away inside 57% 80 waiting 0 heat/cool Figure 1. Temperature Dial Feature heat to 72 cool to 78 outside 89 A. This is the heat set point position indicator on the dial. This object will be red in color. B. This is the cool set point position indicator on the Dial. This object will be blue in color. C. This is the location area where no system demand is active. In figure 1, the example would be any temperature between 73 F and 77 F. D. When there is an active call for heating, this area of the dial will fade back and forth from white to red. E. When there is an active call for cooling, this area of the dial will fade back and forth from white to blue. 2

F. The yellow line indicates the actual room temperature on the temperature dial indicator. Home Screen Information 2:31 am thurs occupied waiting away holiday inside 57% 80 0 heat/cool Figure 2. Home Screen Schedule hold X until next period heat to 72 cool to 78 outside 89 Touch the screen to turn on the back-light if it is off. A. OPERATING MODE - touch to access the screen that will list available modes. Selectable modes are heat/cool, heat only, cool only, off, emergency heat, schedule 1, schedule 2, and holiday. In addition fan operation can be set to on, auto or circulate. B. AWAY - Selecting AWAY will allow the user to set the heating and/or cooling mode temperatures when away from home. Touch cancel to exit this screen and return to the home screen and normal system operations. 3 C. Displays current time. D. Menu - This will allow access to notifications, performance report, schedules and settings. E. This allows you to set the heat-to (if enabled) temperature. Selecting the heat-to or temperature dial position indicator will take you to the temperature setting detail screen. The temperature dial will change from white to red when heating is active. F. This allows you to set the cool-to (if enabled) temperature. Selecting the cool-to or temperature dial position indicator will take you to the temperature setting detail screen. The dial will change from white to blue when cooling is active. G. Indicates the current indoor humidity percentage in the home along with a humidity icon (rain drop). The icon changes based on the humidity level in the home. H. This location could display the outdoor air temperature. What is displayed in that location depends on what sensor is installed and configured through the thermostat user interface. If neither is installed, then this area will be blank. I. Displays the current indoor temperature. J. Indicates the schedule is on hold until the next time period or permanent. Place the schedule on hold by touching on either the heat-to or cool-to location on the screen. If an adjustment is required for the temperature setting, this can be done now. After approximately three seconds the screen will display the override setting options.

From the override setting screen, the options are 1 hour, 2 hour or next scheduled period. Make selection and then touch set. For the 1 or 2 hour setting the home screen will indicate schedule hold until time indicated (i.e., 11:57 pm). To exit schedule hold, touch X When until next period is selected, the set point will be kept until the next program schedule period. To exit until next period, touch X. K. System Status Icons - Equipment operation information appears along the left side of the home screen. The displayed icons will indicate cooling or heating demand, cooling compressor delay, or cooling demand. Icon Table 1. System Status Icons Description NOTE: Touching the icon will display a text description. Humidifying icon is displayed when humidifying is occurring. Touching on the icon will display humidifying next to the icon. Dehumidifying icon is displayed when dehumidifying is occurring. Touching the icon will display dehumidifying next to the icon. Red flames indicates the system is heating. Icon Table 1. System Status Icons Description NOTE: Touching the icon will display a text description. Blue flames indicates the system is cooling. Snow flake indicates the next mode of operation will be cooling. Waiting indicates there is a compressor delay which is by default five minutes. Red flame indicates the next mode of operation will be heating. Waiting indicates there is a compressor delay (heat pump heating) which has a default of five minutes and is not adjustable. Indicates the system is running in emergency heat mode. All heat pumps operating in northern climates below 35 F (1.6 C) normally need a supplemental heating source. Usually it is in the form of electric heating provided by the indoor unit. Other sources could be gas, oil, or hot-water back-up systems as well. The supplemental heat is also referred to as second-stage or back-up heating, with first-stage being the heat pump only. Emergency heat is when you use your supplemental heat (2nd stage) by itself, without the use of your heat pump (1st stage heat). Not available for nonheat pump systems. 4

Icon Table 1. System Status Icons Description NOTE: Touching the icon will display a text description. Indicates the system is running in auxiliary heat mode. Is only available with heat pump system. If outdoor temperature is above the high balance point, only the heat pump will operate - default 50 F (10 C) high. If outdoor temperature is below the low balance point, only auxiliary heating will operate - default 25 F (-4.0 C) low. If outdoor temperature is in-between the high and low balance point, both the heat pump and auxiliary heat sources can operate. Transitioning to next schedule temperature setting. This icon will only appear if smooth setback recovery is enabled under the installer setup. When enabled, it will begin recovery up to two hours before the programmed time so that the programmed temperature is reached at the corresponding programmed event time. Assume 12 F per hour for gas/electric heating and 6 F per hour for first stage compressor based cooling. When smooth set back recovery is disabled, the control will start recovery at the programmed time set in the schedule. setup for up to four days. Go to menu > user settings > edit schedules and select Holiday. To exit Holiday mode, touch the cancel button on the home screen. M. Indicates whether in occupied or unoccupied mode when running a regular schedule. This will be displayed when running schedule 1 or 2 and holiday. Under edit schedules, either occupied or unoccupied can be set under the day time event (occ1, unocc1, occ2 and unocc2). Operating Mode Selection Touch anywhere in the area indicated below to select how the system will operate. 2:31 am thur occupied away holiday inside 57% 78 waiting 0 schedule 1 heat to 68 outside 32 Figure 3. Operating Mode Selection L. Holiday Mode - Selecting this option allows for overriding schedules for holidays and special days. When in this mode the thermostat will not follow regular schedules. This override can be 5 Select Modes 1. HEAT/COOL allows the thermostat to switch between heating and cooling automatically.

2. HEAT ONLY allows only heating demand. 3. COOL ONLY allows only cooling demand. 4. OFF indicates system has been turned off. 5. EMERGENCY HEAT allows heat pump system to use a secondary heat source to come on and reach the desired user temperature setting faster. 6. SCHEDULES (1, 2 or holiday) See Edit Schedules on page 13 for customizing schedules). 7. ON, AUTO and CIRCULATE - Select by touching the desired fan operation ON, AUTO and CIRCULATE. When selected a green check mark will be indicated. Table 2. Fan Operation Icon Mode Description on auto circulate Fan is NOT following the schedule and runs continuously until it is changed from the select mode. Fan will follow the fan setting in the selected schedule. Fan is following schedule and cycles during periods of equipment inactivity. Circulate off time is set by the user. If FAN mode AUTO, ON or CIRCULATE is selected during scheduling for the current period, the thermostat will indicate the current fan mode in the information display (FAN ON or FAN CIRC). In the CIRCULATE mode, the fan will follow the setting configured under menu > settings > fan >select fan mode. Under circulate the circulate off time can be set from 1 to 30 minutes. Fan Operation The desired fan mode can be selected in addition to selected mode of operation. 6

User Menu Screen Touch the three lines in the upper right-hand corner of the screen to access the menu. Selectable options under menu are notifications, performance report, edit schedules and settings. menu Touch the contractor info option for assistance. < critical notifications high temperature protection error code: 0004 reminders 05/22 12:23pm dealer info notifications 13 performance report edit schedules Figure 5. Critical Notifications Notifications settings Figure 4. User Menu Screen When a system error or reminder occurs, a pop-up screen will appear indicating the condition. Error code notification pop-up can be dismiss by touching the back button. Contact the dealer to resolve the issue. For notification, touch either clear or set a future reminder. Any active history for notifications (critical errors or reminders will be listed under settings > notification. If critical errors occur, they will also be displayed under notifications as illustrated in figure 6. 7 Reminders When reminders occur, they will also be displayed under notifications as illustrated in figure 7. Touch the clear or remind later to redisplay active reminder for 1 day, 1 week, 1 month, 3 months or a custom date. < media filter critical notifications reminders 05/22 12:23pm Clear remind later Figure 6. Reminder Notifications

Performance Report This will display the total number of hours each month that the system has been running. Example would be for mar (March) 23H or 23 hours. To return to the menu screen, touch the house icon in the upper left-hand corner of the screen. Red bar indicates heating and blue indicates cooling hours ran. Edit Schedules Any schedule can be edited by touching the right arrow next to the desired schedule. < edit schedules The edit schedules screen will allow section of up too three separate schedules. On the edit schedules screen, each schedule can be renamed and edited. See Figure 8. Renaming and Editing Schedules on page 9 for editing schedules. NOTES: The fan mode that is selected under the edit schedules screen will always override the fan mode selected under the select mode screen or user settings > fan screen if different For example, if the select mode fan setting or user settings > fan is configured for Auto, and the schedule fan mode is set to circulate, then the system will follow the fan mode selected in the active schedule. schedule 1 > schedule 2 > holiday > add schedule Figure 7. Edit Schedules Screen NOTES: See Operating Mode Selection on page 5 to run a specific schedule. From the HOME screen touch the MENU and touch edit schedules option. 8

edit schedules schedule 1 schedule 2 schedule 3 schedule x (rename) select days select mode select days individual days week/weekend all 7 days select mode heat/cool heat only cool only To navigate to the next screen in the selection process, always touch the right-arrow next to the desired option. Individual days Week / weekend all 7 days Monday Tuesday Wednesday Thursday Friday Saturday Sunday week weekend All days * OCC1 UNOCC1 UNOCC2 UNOCC3 wake (rename) time cool-to heat-to fan occupancy time cool-to and/or heat-to select fan mode on auto circulate If period deleted select time or delete period * A maximum of four time periods can be used. If any time periods are deleted, an option to add a time period back will appear on this screen. select occupancy occupied unoccupied Figure 8. Renaming and Editing Schedules 9

User Settings Menu Table 3. User Settings (General) Setting Selection Function Description fan See Fan Operation on page 6. heat / cool (either heat pump, gas or electric heating is selected) cool only (option only appears if no heating equipment is avail able or configured) humidity - Allows selection of dehumidification. Option only available if enabled in installer settings. normal comfort emergency heat set point range set point range dehumidify Heats home to desired tempera ture setting. Options are on or off. If system is two-stage heating or cooling, then 2nd stage is locked in until demand is satisfied. Bypasses the first stage of heating (any stage[s] of heat pump heating) and goes directly to the heat stage used for maximum heating to more quickly warm a very cold house. Heating limit with a default of 0 F. Range is 45 F to 90 F Cooling limit with a default of 45 F. Range is 45 F to 99 F Cooling limit with a default of 45 F. Range is 45 F to 99 F Options are ON and OFF. Allows dehumidify adjustment setting between 45% to 60%. Default is 50%. 10

Table 3. User Settings (General) Setting Selection Function Description reminders - Items on this list are by default disabled. Media filter, humidity pad, routine system check up, UV lamp, metal insert for PureAir and customer reminders 1 and 2*. Options for each reminder are disabled (default), 3mon, 6mon, 12mon, 24mon or a custom duration by specific date can be set. Once set an expires on xx/ xx/xx (date) will be displayed next to the function. *Custom reminders 1 or 2 may have been renamed by the installer. about Displays information concerning thermostat model number, serial number, hardware and software revisions. general - provides information about the thermostat and settings for screen lock, date & time and language. screen lock date & time language Setting options are unlocked, partially, and locked. To set partially lock, create a three digit code. Partially lock restricts access to the menu. To set locked, create a three digit code. Lock restricts access to anything on the screen. NOTE: Partially Lock and Locked is set for one instance only. Either would need to be set each time it is desired to partially locked or locked the screen. Master code is 864 in case user forget their custom code. Settings for 24-hour clock (military), daylight savings, set time and date. Languages available are English, Spanish, Portuguese and French. 11

Table 3. User Settings (General) Setting Selection Function Description general - provides information about the thermostat and settings for screen lock, date & time and language. display - Allows the user to control some information that is displayed on the home screen. occupancy Outdoor temperature display or discharged air display (what is displayed here depends on sensor used and configured by installer. screen saver screen brightness temperature scale clean screen Pre-Occupancy: Options are 0 through 3 hours with a default of 0 hour. This selection opens the dampers early, either 1, 2 or 3 hours. Post-Occupancy: Options are 0 through 3 hours with a default of 0 your. This selection keeps the dampers open, either 1, 2 or 3 hours. Options are off or sensor. Options are enable and disable. Default is enabled. When enabled only the time and inside temperature is displayed on the screen. Touching the screen will restore all other details. The back light setting is also on the same screen. Options are continuous on or energy save. Default is continuous on. A horizontal adjustment bar is provided to move from minimum to maximum brightness. F for Fahrenheit or C for Celsius. This will disable the touchscreen for 30 seconds. 12