aquilar - leak detection solutions

Similar documents
aquilar - leak detection solutions

Installation, Operation and Maintenance Manual

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

TraceTek TT1000 Modular Sensing Cable

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Modular Sensing Cable Installation Instructions

TT3000 and TT5000 Series

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TT3000 and TT5000 Series

TraceTek TT1000 Modular Sensing Cable

AT-G-SENSE Gas Sensing System

Sensor Interface Module Installation/Operation Instructions

Gardian W51. Approvals

Industrial Strength Leak Detection

AT-G-DETECT Gas Sensing System

TT3000 and TT5000 Series

AquiTron. AT-WM Water Monitor DATA SHEET

TraceTek Leak Detection

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

TTSIM-1 Sensor Interface Module

TraceTek Long-Line and Zone Leak Detection and Location Systems. Operation and Maintenance Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Public Safety DAS Annunciator Panel

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Model 4001 Series Single Channel Controller

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

TT7000-HUV TraceTek Sensing Cable for Strong Mineral Acids

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Raychem Heating System

C Electrical Connection Kit

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

EXTINGUISHING AGENT RELEASE MODULE

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

RayClic Connection System

Installation Operation Maintenance

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

TECHNICAL DATA OBSOLETE

Installation Guide for models:

Series. Access Power Controllers. Installation Guide

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

PANTHER. Condensate removal pump Installation and operating guide

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

SAFETY INFORMATION AND WARNINGS

Installation Instructions

Excel-EN Conventional Fire Control Panel

/9308 External Battery Chargers Installation Instructions

Installation, Operating and Servicing Instructions

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

KM300 Carbon Monoxide Detection System Installation Manual

OPERATION AND INSTALLATION MANUAL

ACCS-30. Multipoint commercial heat-tracing control system

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

PO Box 827 Hawley, MN (218) Fax (218)

Eco IR Basin Tap. Installation and Maintenance Guide. A basin mounted tap with pre-programmed infra-red sensor; mains or battery supply.

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

MBCE-110/230UV Flame Sensor Module

Installation & Maintenance Instructions

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

SUBMERSIBLE WATER PUMPS

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions

Installation Guide for models:

Intelligent Security & Fire Ltd

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

VENTILATION FAN / LED LIGHT

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Transcription:

AT-MZA Multi Zone Alarm OPERATI & MAINTENANCE MANUAL AT-MZA Multi Zone Alarm OPERATI & MAINTENANCE MANUAL

Product Information MZA 115Vac +15%, -20%; 50/60 Hz 230Vac ±10%; 50/60 Hz 12Vdc ±20% Power consumption 12 watt maximum Relays One relay per zone (maximum 8) SPDT One common relay SPDT One summary FAULT (cable break/power failure) SPDT Rating: 3 A at 250Vac/24 Vdc Temperature Storage: -18 C to 60 C (0 F to 140 F) Operating: 0 C to 50 C (32 F to 122 F) Enclosure Aprovals NEMA 12; IP54 The MZA is approved for use in ordinary areas. The module must be located in an Ordinary Area, but may monitor intrinsically safe TraceTek sensing cables located in Hazardous Locations: Maximum Circuit length TraceTek sensing cable in Class I, Division 2, Groups A, B, C, D Hazardous Locations. If protected by agency-approved zener barrier TraceTek sensing cable in Class I, Division 1, Groups A, B, C, D Hazardous Locations (Zone 0 or Zone 1 in Europe). Contact your TraceTek distributor/agent to select proper zener barrier. 100m (328ft) TraceTek sensing cable or 10 water or optical oil probes per zone. Leader and jumper cable lengths are not included in this limitation. General Information Please read these instructions carefully and keep them in a safe place (preferably close to the module) for future reference. These instructions must be followed carefully to ensure proper operation. The MZA multi zone alarm has been designed specifically for use with TraceTek sensing cables (TT1000, TT3000, TT5000, TT5001 and TT7000). The MZA can monitor per zone up to 100 m (328 ft) of sensing cable, or 10 water detection probes. Optical probes, float switches and level indicators can also be incorporated into the system. The MZA is designed for use in ordinary areas with temperatures of 0 C to 50 C (32 F to 122 F). Installation items (not supplied) Wall fasteners for surface mounting (four screws) Rubber or elastomeric washers to seal at mounting points Semi-flush recess flange (optional) Tools required Drill or hole punch for electrical conduit entries Phillips (cross-head) screwdriver Small flat-head screwdriver Storage Keep the module in a dry place prior to installation to avoid possible damage to internal components. Additional items AT-BU Battery Unit c/w battery for 24 hrs operation AT-BAT Replacement 12Vdc, 7Ah Battery AT-MZA-SFMF Semi Flush Mounting Flange 5 6 7 8 9 10 11 12 1 2 3 4 PL PL PL PL 26 25 24 23 22 21 20 19 18 17 16 15 14 13 1. LEDs with icons 2. Silence key 3. Reset key 4. Zone LEDs 5. Battery connection 6. Spare fuse 7. Fuse (1600mA, 250V) 8. Fuse (1600mA, 250V) 9. Zone exp card connection 10. Voltage selector (110 or 220V 11. Power cable terminal block 12. Motherboard 13. Summary leak & fault relay plug and socket 14. Z1/2 Fault relay cable plug and socket WARNING: Shock hazard. Shut off power before opening enclosure door. 15. Z1/2 Sensing cable plug and socket 16. Z3/4 Leak relay cable plug and socket 17. Z3/4 Sensing cable plug and socket 18. Z5/6 Leak relay cable plug and socket 19. Z5/6 Sensing cable plug and socket 20. Z7/8 Leak relay cable plug and socket 21. Z7/8 Sensing cable plug and socket 22. Ground/earth stud 23. Ribbon cable 24. Ground/earth stud 25. Buzzer mute link 26. User Interface board PL Indicates power limited circuits.

PL PL PL PL Note: To avoid damage to the MZA and the MZA-EXP electronics, store them in their cardboard boxes until construction is complete. Select the mounting position Choose a location indoors where the module will be protected from the elements and temperature extremes. WARNING: Ignition hazard. Do not mount the MZA unit in a hazardous location. Sensing cable connected to the MZA may (subject to approvals restrictions) be located in hazardous locations, but the module itself must be in an ordinary area. Prepare the module for mounting Important: The MZA is an electronic unit. During installation, take the following precautions to avoid damage to its electronic components: Handle with care, avoid mechanical damage. Keep the electronics dry. If handling circuit boards, hold them by their edges to avoid physical contact with electronic components. Avoid exposure to static electricity. Avoid contamination with metal filings, liquids, or other foreign matter. Remove the module from its packaging. Open the enclosure door using a flat-blade screwdriver or coin. Anti static precautions should be taken before touching the boards inside. Carefully disconnect the ribbon cable from the motherboard. Unscrew the four Phillips (cross-head) screws holding the motherboard to the enclosure (see Fig 1). Remove the motherboard, and put it out of harm s way. Taking care to protect the User Interface board on the enclosure door, drill/punch entries as required (see Fig 2). Note: The AquiTron / TraceTek sensing circuit is power limited, so the TraceTek leader or jumper cable and the power supply cable must not run in the same conduit. Fit conduit bushings/adapters. Remove all traces of metal filings and dust from inside the module enclosure. Mount the module The module mounts with four screws with mounting centers as noted in Fig 3. To seal around the mounting screw (necessary to maintain the IP54 rating), use a rubber or elastomeric washer. Reassemble the module Note: Before replacing the motherboard, ensure that the interior of the enclosure is clean. Replace the motherboard and secure it in place with the Phillips (cross-head) screws. Reconnect the ribbon cable (taking care not to bend any pins in the connection). Close and secure the door of the enclosure. PL PL PL PL 210mm 165mm Figure 2 Figure 3 190mm 240mm Cable entry knockouts are provided as follows: Back plate 4 x 20mm and 3 x 3/4 Base of enclosure 6 x 20mm and 5 x 3/4 Connecting the Power Cable and Relays Connect the power wiring Open door of MZA enclosure. Additional area available for cable entries (no knockouts) Pass the power cable through the knock-out/adapter/bushing if fitted. Note: Proper grounding/earthing is important to avoid the possibility of electromagnetic interference. Connect the power supply wires to the special three-pin terminal block marked LNE (Live, Neutral, Earth), observing the polarity. The electrical supply should be fused at no more than 3amps via an un-switched fused spur adjacent to the unit. Note: Set the voltage selector switch to the required voltage 220 or 110Vac. The terminals can accept wires 12 to 24 AWG. Note: Do not exceed maximum voltage. Battery Back-Up The unit is equipped with a 12Vdc battery back-up power circuit. If this option is required connect the + and - (positive and negative) battery leads (leads not supplied) (fig 5). A separate battery unit is available AT-BU which will house a 12Vdc 7Ah battery - AT-BAT. Batteries should be tested, maintained and replaced in accordance with the battery manufacturers instructions and recommendations. x15 x1 L N Figure 4 BATTERY + Figure 5 Figure 1 Remove all six screws attaching motherboard

Prepare sensing cable/sensing probe/device Ensure that the sensing cable (sensing device) has been installed in accordance with the instructions provided. Make connections Confirm that the power to the MZA unit has been turned off. Open the enclosure door. Feed the end of the TraceTek modular leader cable (or bulk jumper cable) through the knockout/adapter/bushing if fitted. Connect the four colour-coded wires to the Sensor Interface plug, X3, X7, X10 and X12 (see Fig 6). Select a spare connector between zones 1 to 8. Zones 1-2 do not require the insertion of a zone expansion card, MZA-EXP. Three cards can be added to the base unit, giving a total of 8 individual zones. Provided the relevant zone expansion card has been inserted, you can select any sequence for connecting the sensing cable or sensing devise. Figure 6 x3 x7 x10 x12 Important: Observe the colour coding. If wires are not connected to the correct terminals, the leak detection system cannot operate properly. Insert the sensing cable (SI) plug into the SI socket (item 15, 17, 19, 21 on the product illustration on the first page). Isolate spare sensing zones If the second zone in any of the two zone blocks is not to be used it must be terminated with loops of cable between red-green and yellow-black. (See figure 7). This will prevent the system identifying this zone as having a cable break. However, should there be a requirement for all three-expansion cards to be installed, but not used, then these must be terminated in a similar fashion. Each spare sensing zone circuit must be terminated with a loop of cable between red-green and yellow-black. See figure 6.This will prevent the system seeing this zone as a cable break. The loop is only required if zone 1 or 2 are not connected and any subsequent zone where a MZA-EXP zone expansion card are fitted. Connect the and FAULT (Cable break) relays The MZA has: One relay per zone One common relay One summary FAULT relay Relay identification: relays: Zones 1 & 2, X13 - Z1 bottom, Z2 top Zones 3 & 4, X11 - Z3 bottom, Z4 top Zones 5 & 6, X8 - Z5 bottom, Z6 top Zone 7 & 8, X5 - Z7 bottom, Z8 top Common relay: X14 Bottom connection FAULT relay: Common to all zones X14 Top connection All relays are SPDT and independent of the next. The MZA s FAULT relay will also indicate power failure as the relay contacts will de-energize to signal an alarm condition. Therefore, loss of power as well as a cable break would trip the relay and any equipment connected. Note: The relay plugs can accept wires 12 to 24 AWG. Cable should have a temperature rating of 65 C. Note: Maximum load for relays is 3 amps, 250Vac/24Vdc. x14 x13 x11 x8 x5 Connecting the Zone Expansion cards Important: The MZA-EXP is an electronic unit. During installation, take the following precautions to avoid damage to its electronic components: The MZA panel should not be powered when installing the MZA-EXP card. Anti static precautions should be taken before touching the boards inside. Handle with care, avoid mechanical damage. Keep the electronics dry. If handling circuit boards, hold them by their edges to avoid physical contact with electronic components. Avoid exposure to static electricity. Avoid contamination with metal filings, liquids, or other foreign matter. Figure 7 x3 x7 x10 x12 A maximum of three MZA-EXP cards can be added to a MZA panel. Each MZA-EXP provides two additional zones of sensing. Remove the card from it s static free packaging. Insert the first card on vertical connector marked zones 3-4 and the following cards on zones 5-6 and zones 7-8. The card will only fit in one direction. Push the card securely to the base connector. Once the card has been securely installed the MZA panel can be powered.

/ / Start-Up and System Testing Power up the system Note: Check the voltage selector switch has been set to the correct country/application voltage. After connections are complete supply power to the unit. If the sensing circuit is complete and free of leaks or other problems, the green Monitoring LED only will illuminate. If this is not the case, you can find additional information in the MZA Operation and Maintenance Manual supplied with the module. Install Zener barrier, if applicable When sensing cable will be located in Class 1, Division 1 locations, approval agencies require that the sensing cable be protected with a zener barrier between the sensing cable and the MZA module. A zener barrier may also be used to provide lightning protection for the module when the sensing cable may be exposed to electrical discharges. Contact your distributor/agent to select the proper zener barrier. One will be required for each sensing zone. When installing a zener barrier, wire it in accordance with the instructions provided with the kit. Commissioning Your system should be commissioned by an authorised AquiTron( or TraceTek representative. The system map is a crucial part of the system and should be located adjacent to the unit and within the O&M documents. Important: Store hardware and documentation supplied with the MZA in a secure place for later use (commissioning, connecting interfaces, operating). Testing the Module Test after supplying power Close and latch the enclosure door. Supply power to the unit. When power is supplied, the green LED illuminates for mains power (red for battery supply). After the start-up sequence is complete, the module should report a fault alarm (this is normal: there is no sensing cable attached). Press the red Silence key to silence the audible alarm. Verify that the red Alarm plus yellow Cable Break LED s appear. If anything other than the above occurs, check all connections. If the unit still does not appear to operate properly contact your supplier for assistance. MZA Ordinary Area Zener barrier Leader or jumper cable Class I, Division 1 (Zone 0 or Zone 1 in Europe) Hazardous Location Sensing cable Jumper cable / Terminal Connection Layout TOP FAULT M BOTTOM M Z8 Z6 Z4 Z2 x3 x5 x7 x8 x10 x11 x12 x13 x14 Z7 Z5 Z3 Z1

Cleaning the Module To clean the outside surface, use a damp cloth or sponge. Do not use solvents or abrasive cleaners, and do not open the enclosure while it is wet (it is an electrical device). Fuse Replacement The fuse on the power supply board (item 7 on the internal layout drawing) is a 1600-mA, 250-V. Use no other type of fuse or the SZA could be damaged or fail to perform properly. A spare fuse is provided and positioned on the mother board item 4. Routine Maintenance It is recommended that the AquiTron and TraceTek systems be thoroughly checked twice a year. Such a check will identify conditions that adversely affect the leak-locating capability of the system. More frequent checks may be required if the sensing cable is repeatedly exposed to leaks, or if construction or repair work is done where the sensing cable may be exposed. Contact your local AquiTron or TraceTek representative for further information on service and maintenance support. Storage and Handling of Sensing Cable Despite their rugged construction, TraceTek sensing cables must be handled in a manner appropriate for a sensing device or they may be damaged and require replacement. Therefore, you should follow some basic rules for storing and handling all TraceTek sensing cables: Store spare cable in its original container in a clean, dry place until ready for installation. Schedule cable and probe/sensor installation after all mechanical, plumbing, and electrical work has been completed. Clean the area where the cable is to be installed, and remove any obvious debris or other sources of contamination. Do not solder or weld near the cable without providing protection from heat, solder flux, or weld splatter. Do not drop tools or floor tiles on the cable; sharp and heavy objects may damage the cable. Avoid walking or stepping on the cable. Provide shielding (for example, a half shell of plastic pipe) where additional protection is necessary. Do not use tape to secure sensing cable (some tapes and adhesives absorb moisture) or use solvents that could eventually cause an alarm. Do not drag sensing cable through contaminants (such as pipe dope, PVC cement, solvents, oil, or dirt). Note on Cable Cleaning TraceTek TT1000 and TT3000 use a solid core polymer construction and can usually be easily cleaned with tap water. In extreme cases or when large amounts of cable are contaminated, either cable can be washed in an ordinary dishwasher. Try a water only (no detergent) cycle first and avoid the heated dry cycle. When placing the cable in the dishwasher be sure to tightly connect the male connector on one end to the female connector on the other. Keep water out of the connectors. TT5000 and TT5001 cannot be cleaned without special equipment. These cables normally require replacement after exposure to fuel or solvent. Periodic Maintenance and Testing Recommended Interval: Perform a functional check per the following procedure at 6-month intervals. Repair or replace all damaged wiring and senor cables. There are no field repair procedures for the MZA panel. If the module fails to perform the functional tests it must be replaced. Test Procedure: 1. Normal Operation: Look for Green POWER LED 2. Leak Simulation: For systems using TT1000, TT3000 sensor cable or a detection probe, use a TraceTek Mapping Tool or a small container of water to simulate a leak. After the time delay has expired (maximum 15 seconds) look for the following indications: Red LED on Green POWER LED on ALARM in ALARM condition (Note: This may cause equipment shut down if devices are connected to the ALARM relay contacts) Remove simulated leak Red LED goes out For TT5000 and TT5001 systems, simulate a leak condition by tightly bending and holding the sensor cable. 3. Cable Break Simulation: For any sensor system, disconnect any one wire at the sensor cable terminal block or disconnect any connector in the system. Look for the following indications: Yellow CABLE BREAK LED on ALARM in ALARM condition Restoring the connection should cause the MZA to return to the normal indications for that zone. Final Check List 1. Complete a system inspection in the presence of the owner. 2. Ensure a plan showing the location of the sensor is available. 3. Check that the following information is clearly visible adjacent to the alarm module: In case of alarm instruction. Location of the system map in case it is not installed adjacent to the alarm module. Name and contact number of the person responsible for operating the system. Supplier s contact name and address. 4. Hand over these Installation, Operating and Maintenance Instructions. 5. Make the owner aware that it is strongly recommended to perform a systems check at regular intervals, at least every six (6) months. Investigating Leaks and Faults If the location of a leak is not apparent, it is often useful to subdivide the leak detection circuit, as illustrated below. To accomplish this, it is recommend have a TraceTek Portable Test Box (PTB) and an extra Modular End Termination is used. Contact your local TraceTek representative to obtain these products. Note that the PTB comes with instructions on how to use it. To segment the system (one individual zone) and isolate problems, find a TraceTek sensing cable or jumper cable connection at a convenient point somewhere at the center of the detection circuit. You can then use a PTB to check one portion of the system (to verify circuit integrity, to detect the presence of liquid, and even to determine its location, as the PTB will give you an indication in feet or metres to the point of the leak). If you install an end termination on the other length of cable (going back to the MZA panel), you can use the MZA to check the front half of the sensing circuit. You can further subdivide the circuit, and even test individual lengths of cables, as shown in the third diagram below. Even the most perplexing problems can usually be isolated and resolved using this methodical approach.

TraceTek or AquiTron Leak detection alarm panel End termination End termination Problem: CABLE BREAK indication but cable appears to be intact. Possible Cause: Loose connections at terminal block. Action: Check all terminal block screws for tightness. To test the module by itself, use two small pieces of wire to form temporary jumpers from red to green and yellow to black at the sensor cable terminal block. This simulates a very short piece of sensor cable and the yellow CABLE BREAK LED should go off. If the MZA cannot pass the jumper wire test it may require replacement. TraceTek or AquiTron Leak detection alarm panel Trouble Shooting End termination PTB End termination Possible Cause: Cable is dirty (TT1000, TT3000). Action: Clean cable using water (no solvents, acetone, white spirit or turps). Dry the cable and check MZA front panel. Heavily contaminated cable may require replacement. But if dirt is accumulating, cleaning and/or replacement will eventually be required. Possible Cause: Cable is exposed to occasional water spraying (TT1000, TT3000) Action: It is best to keep the sensor cable at least 1 meter (3 feet) from the outflow of any air conditioner units. Possible Cause: Cable is in contact with sharp metal edges (TT1000, TT3000) Action: Check the sensor cable for possible points of contact with sharp edges such as the edges of drip trays or the pipe threads on adjustable floor supports, trunking and ducting. Reposition the cable as necessary or insert a small piece of insulating material to prevent the cable from making contact with the metal edge. Problem: BMS/PLC or other host system detects a fault when the MZA is operating in NORMAL mode. Possible Cause: Loose connections at terminal block or broken wires between MZA and BMS/PLC. Action: Check all terminal block screws for tightness. Many installations use a normally closed contact to indicate a normal condition at the MZA. If the wiring between the MZA and the BMS/PLC is loose or open, then the host system will read the open circuit as a fault regardless of the MZA status. Normal Mode Indications: LED (Red) CABLE BREAK LED (Yellow) POWER LED (Green) ALARM/TROUBLE Leak Detection Indications: LED (Red) CABLE BREAK LED (Yellow) POWER LED (Green) ALARM/TROUBLE User Action: NORMAL (de-energised) ALARM (energised) 1. Locate the spill area, investigate the cause of the spill and take necessary repair actions. 2. Clean up in the spill area and clean and dry the cable / probe, if necessary. LED will turn off when cable / probe is dried. Cable Break Indications: LED (Red) CABLE BREAK LED (Yellow) POWER LED (Green) ALARM/TROUBLE User Action: ALARM (energised) 1. Investigate the sensor cable and leader cable for physical damage. Check connectors for damage. Make repairs or replace components as necessary. 2. CABLE BREAK LED automatically turns off when normal sensor cable continuity is restored. The Alarm Relay automatically returns to the NORMAL position when cable continuity is restored. Possible Cause: Cable is pinched (all cables). Action: Check the sensor cable for possible pinch points. TT5000 and TT5001 can be tripped if tightly bent or compressed by a heavy object. TT1000 and TT3000 can be tripped by heavy pressure from a metallic object. Check the entire cable installation for pinch points and correct the condition. Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Aquilar Limited makes no warranty as to the accuracy or completeness of the information, and disclaims any liability regarding its use. The only obligations of Aquilar Limited are those in the Aquilar Standard Terms and Conditions of Sale for this product, and in no case will Aquilar Limited be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product. Specifications are subject to change without notice. In addition, Aquilar Limited reserves the right to make changes - without notification to Buyer - to processing or materials that do not affect compliance with any applicable specification. AquiTron is a trademark of AquiTron Limited Aquilar is a trademark of Aquilar Limited TraceTek is a trademark of Tyco Thermal Controls Aquilar Limited Weights & Measures House, 20 Barttelot Road, Horsham, West Sussex RH12 1DQ. UK Tel: + 44 (0) 1403 216 100 Fax: +44 (0) 8707 940 320 E-mail: info@aquilar.co.uk www.aquilar.co.uk Master TraceTek Distributor UK & Ireland for Raychem TraceTek Water, Fuel and Chemical Leak Detection 2003 AQUILAR LIMITED Printed in the UK. H9800 09/03