Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

Similar documents
Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

Inline-Pumps Type NCV /NCVL

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA

Selfpriming Centrifugal Pumps. Type HZS/HZSA

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Heavy Duty Process Pumps API 610/ISO 13709

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

Full-line Product Overview

Horizontal Split Case Pumps Type U

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y HVN. Double Suction, Heavy Duty API 610 Process Pump (BB2)

380 Series Multi-Stage Centrifugal Pumps

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Centrifugal Pumps API 610

380 Series Multi-Stage Centrifugal Pumps

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

CAP SERIES SEWAGE AND WASTE WATER PUMPS

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

Dean Pump High Temperature Chemical Process Inline Pumps

Industrial. Solutions brands you trust. Product Overview

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Rotodynamic Pumps INTRODUCTION:

Specially Designed Waste Water & Sewage Pumps

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Sewage Pumps. KS - Channel Type Pumps W, WTS - Vortex Type Pumps

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Goulds Large Capacity, Single Stage, Double Suction Pump

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

PENGUIN SERIES HSC PUMPS INTRODUCTION

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

SIHI multi Modular multistage pumps

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

dualarm Vertical In-Line Pumps

Vertical Heavy Duty Pumps

ETP Series - Self Priming Pumps

Worthington CNG process pumps.

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

SECTION FIRE PUMP AND CONTROLS

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

SECTION STEAM CONDENSATE PUMPS

MAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE

ROWA -HP High-Pressure Centrifugal Pump

CombiBloc Close-coupled centrifugal pumps

Lenntech. Tel Fax bar. Multistage Pumps.

MARLOW PUMPS RECIRCULATION

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

MCV - MCH - MCHZ Multistage pumps

VRD. Sump pump for polluted liquids

Goulds LP3400 Series Low Pulse Fan Pumps

VPC Vertical Turbine, Double Case Pump

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

SUMY Catalogue. Product Line. Centrifugal Pumps СУМЫ SUMY ENGINEERING WORKS Ltd PUMPING EQUIPMENT DESIGN, MANUFACTURE AND SALE

1 of 68. Thong Fatt Jaya Machinery Hardware Sdn. Bhd. DOUBLE-STAGE LIQUID RING VACUUM PUMP. Air- Operated Double Diaphragm Pump TW Series

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Here is your conveying solution: Product group D.

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

Vertical Ring-section Pump WKTB. Type Series Booklet

References are in agreement with UMRL dated April 2018 **************************************************************************

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

Chemical Pumps Vertical Chemical Pump Type TNP

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

SL S.S.N.51D

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Pumps SELECTION OF A PUMP

Goulds Trash Hog. Self-Priming Solids Handling Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF. Vertical Submersible Pump

Transcription:

Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

General The DICKOW centrifugal pump, type NCL, is designed for handling liquids in the chemical and petrochemical industry, in refineries, for heat transfer liquids ect. Dimensions and performance range are developed according to DIN EN ISO 2858:2011-12. The whole range is subdivided that for all service conditions the best efficiency is guaranteed. The maximum capacities go up to 1000 m 3 /h or 4400 US gpm. With a wide selection of materials and shaft sealing systems they are suitable to handle nearly all kind of liquids which are common in the above mentioned industries. For example we call light fuels (all kinds), acids, lyes, solvents, hydrocarbons, heat transfer liquids, heavy fuel, liquid sulphur, melted plastics, bitumen ect. For handling hot water above 190 C (375 F), additionally our pump types NHL are available. Relevant leaflet can be submitted on request. Design The DICKOW centrifugal pumps type NCL are single-stage, single-flow volute casing pumps in back pull out design, with an end suction flange and a centerline discharge flange. Bearing housing with intermediate casing, shaft sealing and impeller is mounted to one unit. With the back pull out design, unit can be removed without demounting the pipe connections. In order to have full advantage of back pull out design spacer type couplings are recommended, the motor can then remain bolted on the base plate. Pump casing with heating jacked For example fluids like: Dimethylterephthalat (DMT), sulphuric liquid, Phenol etc. Heating jackets on volute and intermediate casings with welded cover are designed for heating liquids up to 24 bar (350 psi) and 220 C (430 F). Centerline-mounted casing Hot fluids cause expansion of the pump casing. In order to minimize coupling misalignment and thermal stress we recommend centerline mounted pump casings for high temperatures. All NCL-sizes can be delivered with centerline supported pump casings on request. Volute casing The pump casing of standard design is cast in one piece and foot mounted on the base plate. The casing is sealed to the atmosphere by confined non-asbestos gaskets. If required by end-user or handled fluid, following special designs are available: Pump casing with heating jacket Pumps with heating jacket are required if the liquid temperature decreases when flowing through the pump or when the liquid temperature drops below the melting or cristallization point during plant shut down. Centerline-mounted casing

Impeller Closed impellers are standard. Impellers are casted in one piece with solid hubs. To minimize the axial load of the bearings, the impellers are fitted with wear rings on the back and balance holes to the suction. Impellers are properly statically and dynamically balanced in acc. to DIN ISO 1940T1 Grade 6,3. In order to have satisfactory seal performance the shaft diameter and overhung are sized to minimize shaft deflection at the seal faces. The shaft construction guarantees a critical speed of more than 10 % over the maximum operating speed. The connections cap screw hub and hub shaft sleeve are sealed by confined gaskets and the pump shaft has no contact to the pump fluid. Bearing The pump shaft is carried by generously dimensioned antifriction bearings outside the pumped liquid. The bearings are oil lubricated. The oil level is regulated by a constant level oiler. A fixed double-row angular ball bearing of Conrad-type (no filling slots) is mounted on coupling side, a roller bearing provides support on pump side. Calculated service life of bearings is min. 25000 hours. NCL o with open impeller For handling liquids, containing solids such as slurry and suspensions, the NCL o type with open impeller is available. NCL o pumps are fitted with renewable wear disks on suction side to minimize maintenance costs. The overhung mounted impellers are secured on the shaft by a key and a cap screw with Heli-Coil insert. Not all pump sizes are available with open impeller. Bearing bracket Bearing brackets of NCL-pumps are of split design. Therefore, it is possible to supply the pump sided bearing bracket lantern of corrosion resistant material when handling aggressive liquids. The pump sided radial seal ring located in the bearing bracket lantern is protected by an additional deflector which avoids entrance of potential leakage from mechanical seal. The bearing bracket lantern is designed as drip pan and provided with a leakage connection. If required, bearing bracket can be equipped with additional water cooling chamber. Wear rings Volute casing and intermediate casing of NCLpumps are both fitted with replaceable wear rings held in place by a press fit with locking screws. Additional impeller wear rings are available as an option. The running clearances are in accordance with API 610. Shaft, shaft sleeve The pump shaft is able to transmit the full driver output, is accurately machined throughout its entire length and has properly finished bearing surfaces. Bearing bracket with water cooling

NCL-Design volute casing, foot mounted replaceable wear ring drain plug

heavy duty antifriction bearings bearing bracket, oil lubricated deflector closed impeller confined gasket seal chamber

Hazardous area Together with suitable Ex-drive motors, the NCL-pumps can be applied in hazardous area Group II, Category 2. The pumps meet the basic safety and health requirements of Explosion-proof Directive 94/9 EC and are suitable for plants with increased safety requirement. Application limit Hot water up to 190 C / 374 F (NCL s + NCL hu) Thermal oils up to 350 C / 662 F (NCL s + NCL hu) Pressure limits: NCL s 20 bar / 290 psi - 190 C / 374 F NCL hu 24 bar / 348 psi - 100 C / 212 F (16 bar / 232 psi - 350 C / 662 F) NCL h 16 bar / 232 psi - 100 C / 212 F Higher pressures on request Materials The following specified materials are standard execution. Further materials are available on request. Pumpe type NCL s NCL hu NCL h Volute casing EN-GJS-400-18-LT GP 240 GH 1.4408 Impeller EN-GJL-250 EN-GJL-250 1.4408 Intermediate casing EN-GJS-400-18-LT / St GP 240 GH / St 1.4408 / 1.4571 Shaft 1.4021 1.4021 1.4021 Shaft sleeve 1.4571 1.4571 1.4571 Cap screw St. 60 St. 60 1.4571 Bearing bracket EN-GJL-250 EN-GJL-250 EN-GJL-250 Bearing bracket lantern EN-GJL-250 EN-GJL-250 EN-GJL-250 Type NCB close coupled design

Shaft sealing Gland packing Gland packings are fitted with split cages and split stuffing box ring for an easy replacement of packing rings. Internal circulation or external flushing is possible. Mechanical seals can be installed in the packing chamber on site, no re-machining of parts required. Mechanical seal Pumps can also be fitted with all kind of mechanical seals such as single, tandem or double seals. The standard seal chamber is designed to accommodate seals acc. to DIN EN 12756:2001-03. Special seal chambers for cartridge seals, also acc. to API 682 Cat. 1, can be machined. Heating or cooling of the seal chamber is possible. Single seals can be equipped with throttle bushings, quench connections or auxiliary packing. Mechanical seals arrangements Single mechanical seal with heating jacket, system DICKOW N6b, bellow type, to handle DMT, Sulphur etc. Single mechanical seal with water cooled seal ring, Burgmann H75G15, to handle hot water up to 190 C (374 F). Tandem mechanical seal with Plan 52, system DICKOW N9, bellow type, to handle heat transfer oil up to 350 C (660 F). Single mechanical seal, cartridge type, for quick and easy maintenance.

Performance range Issue 02.17 Performance curves for the individual pump sizes, also for 1750 / 3500 rpm, with NPSH-values and power consumption, are available on request. Technical changes reserved. Printed in Germany. 100-02.17 S&W DICKOW PUMPEN GmbH & Co.KG P.O.Box 1254 84465 Waldkraiburg Germany Phone ++ 49 86 38 6 02 0 Fax ++ 49 86 38 6 02 200 + 6 02 201 info@dickow.de / export@dickow.de www.dickow.de