Installation, Operation and Maintenance Instructions Document Ref:

Ocelot Fan Coil Units

Panther Fan Coil Units

WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

Installation, Operation and Maintenance Instructions Document Ref:

Installation, Operation & Maintenance Instructions Document Ref:

Installation, Operation & Maintenance Instructions Document Ref:

H Y D R O C O U R S E T R E N C H H E A T I N G

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

LOW SURFACE TEMPERATURE RADIATORS

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

SERIES BM. Concealed Fan Convector

Installation Instructions

Installation Instructions

Sovereign Double CC/DD

Efficient Cooling and Heating. Flexibility Is The Key

Panther Fan Coil Unit

Installation and Care Instructions

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Installation and Care Instructions. Wood Blinds and Alternative Wood Blinds. LiteRise Touch System. Getting Started

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

XB-EFA-8L-BK & XB-EFA-8R-BK

Installation and Care Instructions

INSTALLATION. Glass Panel Doors (select models) CAUTION

3RD GENERATION PANEL RADIATOR

3RD GENERATION PANEL RADIATOR

UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Suits all KPF849 models

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

Here is what comes in your box:

Installation Operation Care

Table of Contents. What to Expect with. Mounting Options. Tools Needed

S E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S

Installation Instructions

Installation Instructions

2 Drawer Vehicle Storage System

CONTENTS BEFORE YOU BEGIN

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

60cm Chimney Extractor

Turbo Vac Pro 18V 2 in 1 Cordless Cleaner

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

750MM INDUSTRIAL PEDESTAL DRUM FAN

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

WXC R134a. Nominal Cooling Capacity from 224 to 692kW

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Installation and maintenance instructions

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

Installation and Operating Manual Drying Cabinet

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Thermostatic Concealed Shower Valve

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

FORCEFLOW. 900 Series Fan Convectors

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

HR200WK Through the wall Heat Recovery Ventilator

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

Installation. Leveling

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

EcoBrite Smooth Light LED Light Fixtures

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Aluminum Horizontal Blinds BOX BRACKET INSTALLATION

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

BT16.4SS-HK BT19.4SS-HK Cooker Hood

Installation Operation Care. Vertical Blind Collection Paramount, PermAlign, and PermaTrak Headrail Systems

Installation and Care Instructions

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

OWNERS INSTRUCTION MANUAL

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

What to Expect with Your Installation. Tools Needed. 30 inches PA G E. To register your fan, please visit: 11 PA G E

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

MemoirsStately3HoleBasin Mixer Installation and User Guide

INSTALLATION INSTRUCTIONS TOOLS YOU WILL NEED GETTING STARTED

Hydroflame. Flame-effect fan convectors Installation and User Guide Elite and Classic Models. Contents

Singulier Spout Tube Basin Mixer Installation and User Guide

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Installation and Operation Manual For Hunter Ceiling Fans

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

Owner s Guide and Installation Manual

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Instruction manual. Please keep safe for future reference

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

Installation Instructions

installation and operation manual for Hunter Ceiling Fans

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

Vertical Blinds. Step by Step Installation Instructions

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

Transcription:

System LST Low Surface Temperature Natural Convector Installation Instructions Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 (Global) www.dunham-bush.com Document Ref: 105-000-001-D (UK) www.dunham-bush.co.uk Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER. INTRODUCTION This booklet provides guidance for the site activities necessary to identify, handle, install, commission and service Dunham-Bush System LST Low Surface Temperature Natural Convector. The instructions refer to the standard product only: please refer to any additional drawings supplied for details of any special features. Please study all documentation carefully before commencing installation work. IDENTIFICATION Refer to diagrams for exploded views and identification of the main parts. Any reference given on the order will be marked on the casing, back plate and emitter packages for site identification. DESCRIPTION Each System LST natural convector consists of a back plate, emitter and casing components as shown in the Diagrams. Lock shield valves and TRV kits are optional accessories. HANDLING Casings, back plates and emitters are usually packed separately. Small orders may be packed in boxes and can usually be off-loaded by hand. Larger orders are usually palletised and lifting equipment should be provided by the buyer. Care should be taken when handling to avoid damage. STORAGE System LST components should be stored under dry, clean conditions. Any protective packing should not be removed until the components are required for installation, unless damage in transit is suspected. (Note: The buyer must examine the goods promptly upon arrival and is not entitled to make any claim against the Company in respect of damaged goods, unless at the time of delivery the delivery note is endorsed by the buyer and countersigned by the carrier or shipping agent with a note detailing the damage). PREPARATION A sound, flat, vertical surface is necessary. The screws fixing the casing to the vertical surface are integral to the structure of the casing hence suitable screws and if necessary, wall plugs must be provided by others, for fixing back plates to the vertical surface. Any obstructions or hazards within the wall such as live electrical cables and pipework must first be identified before installation commences. INSTALLATION Before commencing any work identify the correct LST radiator for the location. If a radiator reference was given on the order this will be marked on the packages for site identification. WARNING Some internal components have sharp edges. Care must be taken when installing this product and it is recommended that protective gloves are worn. Page 1 of 16

SYSTEM LST PRODUCT RANGE Dunham-Bush System LST low surface temperature radiators deliver efficient ambient heating in applications where safety is paramount. The hot central heating pipes and heat emitter are totally enclosed within the robust steel casing. The clever casing design permits secure key access for cleaning while TRV control valves can be selected for external or internal (tamperproof) functionality. By applying test results through a mathematical model, Dunham-Bush engineers have developed a Selection Program to help the heating designer optimise their radiator schedules for all conceivable LPHW conditions. BSRIA tested to BS EN 442 heating performance and NHS Guidance touch temperatures, System LST is a complete solution for safe efficient heating. FEATURES The Dunham-Bush System LST radiators comprise: - mild steel casing (stove finish to RAL 9010 white) - extruded aluminium grilles (pencil proof) - zinc coated steel backplate (heat reflective) - integral emitter brackets - choice of Element or Panel emitters - stock or custom RAL and BS colour finishes - available to order. BENEFITS NHS guidance compliance by design and test Optimum heating by natural convection Selection program for all LPHW flow/return conditions 1st and 2nd fix deliveries Rapid cost effective installation No special tools or fasteners required Pencil proof closure-lock grilles (no screws) Reflective backplate to enhance heating efficiency Compatible with all makes of TRV and LSV Lockable access panels Easy access for cleaning BS EN 442 verfied heat outputs Style A - for wet floor areas, or simply where casings are better sited above skirting. Style B for wet floor or dry floor areas where pipes approach from below or through walls. Style C for dry floor areas where the robust floor plinth also provides extra space for pipe runs. Style D vertical casings delivering high performance from confined spaces. Element emitters E11, E21, E12, E22, E23 low water content Cu/Al for unrivalled heating performance and rapid response TRV control, saving energy. Suitable for 2-pipe systems. Panels emitters P31, P41, P61, P32, P42, P62, P72 traditional steel panel design delivering excellent output for 2-pipe and 1-pipe systems. TEST AND WORKING PRESSURES/TEMPERATURES All emitters shall be suitable for maximum cold test pressure of 10.5 barg and maximum working pressure of 8.0 barg. Radiator emitters shall be limited to a maximum working temperature of 95 C. Element emitters shall be limited to a maximum working temperature of 110 C. Automatic airvents maximum cold test pressure is 8.5 barg; maximum working pressure 8.5 barg @ 11/ C. Manual airvents maximum cold test pressure is 10.5 bar, maximum working pressure 6.0 bar @ 110 C. System test and working pressures/temperatures shall be adjusted should fittings and valves supplied by others have test or service conditions lower than above. Page 2 of 16

INSTALLATION SEQUENCE Backplates (1 st Fix) Emitters &Valves (1 st Fix) Sideplates (2 nd Fix) Grilles (2 nd Fix) Casings (2 nd Fix) Page 3 of 16

CASING STYLES Dunham-Bush System LST is available in four styles, A, B, C & D (pictured below). Style A casing Style B casing Style C casing Style D casing Page 4 of 16

Style A 97mm Element Emitter Style A 97mm Radiator Panel Style A 161mm Element Emitter Style A 161mm Radiator Panel Page 5 of 16

Style B 97mm Element Emitter Style B 97mm Panel Emitter Style B 161mm Element Emitter Style B 161mm Panel Emitter Page 6 of 16

Style C 97mm Element Emitter Style C 97mm Panel Emitter Style C 161mm Element Emitter Style C 161mm Panel Emitter Page 7 of 16

Style D 161mm Element Emitter Style D 161mm Panel Emitter Style D 260mm Element Emitter Page 8 of 16

System LST Installation - First Fix Mark positions of fixings on the wall using the back plate as a template. Note: recommended fixing height of 100mm above FFL (Style A), styles B, C & D can be fixed at FFL or onto pipe boxing/trunking. There are a large number of holes provided, as minimum we recommend fixing to every fourth hole along the top and bottom edges plus 2 to 3 fixings down the sides. B C A A C B C B A C A B Diagram 1 Drill holes to take the fixings in the wall and insert suitable wall plugs or anchors (by others). Screw the back plate to the wall using the top and bottom rows of screws holes only excluding the corners ( A in diagram 1 above). The side screw holes B are used for fixing the side plates and can be prepared ready but are not required at this stage. Alternatively the larger holes C may be used as these can be drilled and wall plugs or anchors affixed into them after the back plate has been fixed. X X Z Diagram 2 Using a large flat-bladed screw driver fold out the emitter brackets X. If the convector is to have a fitted internal TRV the phial brackets Z will also need to be folded out. See diagrams 2a & 2b for details on which brackets to fold out for each emitter. Page 9 of 16

Diagram 2a Styles A, B & C. Refer to bracket table for details of required brackets for each emitter type. Diagram 2b Style D. Refer to bracket table for details of required brackets for each emitter type. Page 10 of 16

Diagram 3 Hang the panel radiator or finned element on the brackets as centrally as possible. Fit any lock shield valves and/or TRV valve body. (When fitting a Herz TRV; fit pipe insert (provided) and valve fittings must be assembled using spray silicone oil and compression nuts must be tightened clockwise ¾ of a turn / 270 degrees).note only casings styles B, C & D can accommodate integral flow & return pipework. With the system filled, vent the emitter to expel all air and check for leaks. If fitted adjust lock shield valve to give design water flow rate. Diagram 4 Style A unit fitted with emitters and internal Herz TRV valve/head. Page 11 of 16

System LST Installation - Second Fix Ensure panel radiator is clean or that the finned element is clean and fins are not crushed, before fitting casing. Diagram 5 Position the side plates at either end of the back plate using the studs for alignment (see detail in Diagram 4). Please note that the studs are for alignment only and no fixings are required to be attached to these studs. Screw the side plates through the back plate into holes B prepared during first fix stage. Diagram 6 Fit the Bottom rail between the side plates. To do this you may need to gently push the side plate outward (being careful not to permanently deform it) in order to get the rail to clear the side plate (Detail 1 in Diagram 5). The bottom rail should be engaged with the studs (Detail 2). Two M4 nylock nuts, provided should be threaded onto the studs and screwed down to secure it. Page 12 of 16

Remove the TRV Blanking plate from the side plate nearest the TRV valve body. Diagram 6a Wind the surplus length of the capillary around the TRV dial into the groove provided ensuring that it will not be tight when fitted. Diagram 6b Insert the bellows housing through the aperture in the side plate of the casing. Diagram 6c Page 13 of 16

Affix the Sensor/Set point TRV Dial to the side of the casing using the screws provided. Diagram 7a Attach the bellows housing to the TRV valve body using the knurled nut. Diagram 7b Clip on the cover to the TRV dial Diagram 7c Page 14 of 16

Fit the grilles. On the top grille insert the tab into the slot at an angle with the large rectangular notch towards the front of the heater. Diagram 8a Pull the grille towards you so that the edge of the slot is in the notch. Diagram 8b Then tilt the grille so it is level. Diagram 8c Finally slide the grille back to lock it into place. The bottom grille is fitted in a similar manner with the rectangular notches in the tabs facing upward. Note:- Casing style A Casing style B Casing style C Casing style D Inlet grille is the same as bottom plate. Inlet grille only. Inlet grille & plinth. Large grille. Diagram 8d Page 15 of 16

Diagram 9 Once the grilles are fitted the front plate can be put on. The corner tabs can be distorted in transit hence they may need to be straightened. Insert the tabs at the corners into the slots in the side plates then push the top of the access panel home and lock it into place using the two locks and key provided. MAINTENANCE Every 3-6 months the front panel should be removed, the grilles removed (in the reverse of the method on the previous pages) and the casing inspected for dust and debris. The casing and grilles should be cleaned using a soft brush, damp cloth and warm soapy water. Any dust and debris should be vacuumed from the casing, and the finned element. Care should be taken not to damage the finned element a soft brush attachment should be used. WARNING Some internal components may have sharp edges. Care must be taken when servicing this product and it is recommended that protective gloves are worn. SPARES/SERVICE Spare parts/service Please contact our office, contact information shown below. Manufacturer reserves the right to change any product specification without notice. Dunham-Bush Ltd, Downley Road, Havant, Hants, PO9 2JD Sales and Technical Support Spare Parts and Service Tel: 023 9247 7700 Fax: 023 9245 3601 Tel: 023 9247 7700 Fax: 023 9245 3601 Email: info@dunham-bush.co.uk Email: spares@dunham-bush.co.uk Page 16 of 16