MODEL: DC10RCDH / DC12RCDH

Similar documents
Reverse Cycle Portable Air Conditioner with Dehumidifier

PC20-AMFII / PC40-AMF USER MANUAL

USER MANUAL TPS-M5/M55/M555

PORTABLE AIR CONDITIONER

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

PORTABLE AIR CONDITIONER

2.4kW Ceramic Heater Model: DHCER24SW

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

PORTABLE AIR CONDITIONER

Air Circulator w/electronic Controls, Timer & Remote

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Portable Air Conditioner USER MANUAL

15,000 BTU Portable Air Conditioner

Mobile Air Conditioner Instruction Manual Model TC-N9KM

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

Instruction Manual. Model: EPA 16 Portable Airconditioner

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

Model DAC12004RC. Please read this manual carefully before use and keep it for future reference.

MODEL:DCB09(2.6kW Cooling / 2.4kW Heating) DCB14(4.1kW Cooling / 3.6kW Heating) DCB05C(1.6kW Cooling) DCBB07C(2.2kW Cooling) IMPORTANT

Portable Air Conditioner. Instruction Manual

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Portable Air-conditioner

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

106cm LED Tower Fan with Remote Control

2.4KW CERAMIC HEATER WITH MANUAL CONTROLS

MODEL: DCB07(2.2kW Cooling / 2.05kW Heating) DCB09(2.6kW Cooling / 2.4kW Heating) DCB14(4.1kW Cooling / 3.6kW Heating) DCB05C(1.

Certified to CSA STD. C22.2 No.117

IMPORTANT SAFETY INSTRUCTIONS

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

P O R T A B L E Air Conditioner

Portable Air-conditioner Use and Care Manual

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

Portable Air Conditioner

AC-12200E Portable Air Conditioner

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

POLOCOOL USER MANUAL. For. PC-53AP/C 19,000 BTU(5.5kW) PC-44BP/C 15,000 BTU(4.4kW) PORTABLE REFRIGERATED AIR CONDITIONER

ARTICA. 8000Btu. Room Air Conditioners Portable Range

Dual-Hose Portable Air Conditioner User Manual

MeacoCool MC Series Portable Air Conditioner

Portable Air Conditioner

IMPORTANT SAFETY INFORMATION:

Operating Instructions

Dimplex Air Conditioner DAC 12000R

IMPORTANT SAFETY INFORMATION:

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

PORTABLE AIR CONDITIONER (LOCAL)

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

Local air conditioner

Progress plus Instruction manual

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

PORTABLE AIR CONDITIONER (LOCAL)

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

MeacoDry ABC Range Dehumidifiers

PORTABLE AIR CONDITIONER (LOCAL)

10,000 BTU Portable Air Conditioner

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

General Care and Safety Guide

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

IMPORTANT SAFETY INSTRUCTIONS

Portable Room Air Conditioner and Heat Pump

2.9kW Portable Air Conditioner

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

20L Electronic Dehumidifier

30-pint Dehumidifier User Guide

Dehumidifier. User Manual

Local Air Conditioner

PORTABLE AIR CONDITIONER (LOCAL)

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Portable Air Conditioner Instruction Manual

WA-1240E: 12,000 BTU Cooling only WA-1240H: 12,000 BTU Cooling and Heating WA-1420E: 14,000 BTU Cooling only WA-1420H: 14,000 BTU Cooling and Heating

GDDEM10 DEHUMIDIFIER

POLOCOOL USER MANUAL. 10,000 BTU (2.9kW) 12,000 BTU (3.5kW) PORTABLE REFRIGERATED AIR CONDITIONER. For JULY 2017

2.9kW Portable Air Conditioner

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

5) Do not start or stop the unit by inserting or pulling out the power plug.

PORTABLE AIR CONDITIONER

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

Mobile Type AIR CONDITIONERS (LOCAL AIR CONDITIONERS)

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

Downloaded from manuals search engine

PORTABLE AIR CONDITIONER MODEL NO: AC9000

Utopian Portable A/C

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

LUCCI AIRFUSION BREEZE WALL FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22

air conditioner/dehumidifier 9000btu/hr

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Transcription:

MODEL: DC10RCDH / DC12RCDH INSTRUCTION MANUAL PORTABLE AIR CONDITIONER

IMPORTANT INFORMATION Carefully read this instruction manual before you install or use your portable air conditioner. Please retain this manual for product warranty and for future reference. CAUTION 1. Make sure the inlet and outlet vents are never blocked. 2. Ensure the appliance is on a stable, even surface when operating to avoid water leakage. 3. Do not operate this unit in an explosive or corrosive atmosphere. 4. When switched to cooling, only operate this unit in ambient temperatures between 17 C and 43 C. For heating, only operate this unit in ambient temperatures between 5 C and 23 C. 5. Clean the air filter frequently to ensure efficient operation. 6. To prevent compressor damage when the unit has been operating and is turned off, please wait at least 3 minutes before restarting. 7. This unit needs to be plugged into a 220-240V ~ 50Hz AC, 10 Amp power outlet. 8. Do not use any extension cords with this unit. 9. This unit is for indoor operation only. 10. Open the adjustable air vent and extend the exhaust pipe (and drain pipe, if fitted) to the closest window before using. 11. Only ever have a professional technician, manufacturer or service agent replace a damaged power cord. 12. The batteries from the remote control must be removed and disposed of safely, before the appliance is scrapped. 13. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 14. Children should be supervised to ensure that they do not play with the appliance. Important. Important. The air conditioner must always be stored and The air conditioner must always be stored and transported upright. In case of doubt we suggest you transported upright. In case of doubt we suggest you wait for at least 24 hours before operation. wait for at least 24 hours before operation. (Please keep unit upright at all times) (Please keep unit upright at all times) 1

PACKAGE CONTENTS Portable air conditioner Remote control User manual Extendable window kit PARTS 1. Control panel 2. Remote control receiver 3. Adjustable air vent 4. Window kit adaptor 5. Exhaust hose 6. Hot air filter 7. Hot air inlet 8. Home for remote control 9. Hot air outlet 10. Water filler(for humidifying function) 11. Cool air filter 12. Cool air inlet 13. Water tank 14. Drain hole 15. Outlet grille (for heating and humidifying 16. Exhaust hose attachment 2

CONTROLS AND DISPLAY 1. POWER Press the POWER button to turn the unit "ON" or "OFF". The portable air conditioner is fitted with a compressor delay protection circuit. This protects the unit from possible damage due to rapid starting and stopping of its compressor. Compressor operation begins 3 minutes after the unit is switched on or the mode is switched from dehumidify to air conditioning. 2. FUNCTION Press this key to select cooling, heating, dehumidifying or humidifying. Humidifier: 1. The unit will stop automatically after four hours of operation. Put water into the water filler (10) to restart operation. 2. The unit will stop humidifying if the ambient humidity is equal to the pre-set humidity. 3

3. (TEMP+) In cooling mode, this button raises the set temperature by 1 C each time it is pressed to a maximum of 30 C. In heating mode, this button raises the set temperature by 1 C each time it is pressed to a maximum of 25 C. 4. (TEMP-) In cooling mode, this button lowers the set temperature by 1 C each time it is pressed, to a minimum of 17 C. In heating function, this button lowers the set temperature by 1 C each time it is pressed to a minimum of 15 C. The time taken to reach the desired set temperature will depend on the environment and the size of the space in which the unit is operating in. For example, if the ambient temperature is too hot or the room is too large, the rate at which the temperature descends will be slow as the cooling may be less effective. 5. DISPLAY The display indicates the current set temperature or the timer setting. When the timer or temperature is adjusted, the new setting is shown before the display returns to the current set temperature. The display is also used to show error codes should a fault occur, see ERROR CODES. 6. SPEED Press SPEED to select TURBO, HIGH, LOW or AUTO fan speed. If AUTO fan speed is selected, the unit operates at maximum capacity and turbo fan speed while the room temperature is more than 2 C from the set temperature. When the room temperature is within 2 C of the set temperature, the unit operates at HIGH fan speed. Once the room temperature equals the set temperature, the unit will operate at minimum capacity and low fan speed to efficiently maintain the desired temperature. When TURBO, HIGH or LOW speed is selected, the unit operates at maximum capacity until the set temperature 4

is reached. The fan operates at the selected speed. 7. TIMER ON/OFF button for the programmable timer. The timer can be used to turn the unit on automatically after a set time delay is complete. 1. With the unit OFF, press the "TIMER" button to set the desired time delay before you wish the unit to start. 2. Choose the function desired (cooling, dehumidifier, heating or humidifier.) 3. Once the set time delay is complete, the unit will turn on automatically. 4. If you press the POWER button before the time delay is complete, the delay will be cancelled and the unit will turn on immediately. The timer can be used to turn the unit off automatically after a set time period is complete. 1. With the unit ON, press the "TIMER" button to set the desired time for the unit to remain on. 2. Once the set time period is complete, the unit will turn off automatically. 3. If you press the POWER button before the time delay is complete, the delay will be cancelled and the unit will turn off immediately. 8. SLEEP Press the SLEEP button to select the sleep comfort mode. When the unit is cooling and sleep mode is selected, the unit will raise the set temperature 1 C each hour to a maximum of 2 C over two hours. When the unit is heating and sleep mode is selected, the unit will lower the set temperature 1 C each hour to a maximum of 2 C over two hours. These temperatures will be maintained for the balance of the time set and help maximize sleep comfort. When setting the "sleep comfort" mode, please ensure that you 5

set the number of hours required by using the TIMER function. The hours set will be shown on the display by pressing either the TEMP+ or TEMP- buttons. REMOTE CONTROL FUNCTION On/Off switch Function MODE selector Hourly programming Automatic fan speed Turbo fan speed High fan speed Low fan speed Night operation selector Temperature selector 6

INSTALLATION Unit Setup 1. Remove the water tank and take out the exhaust hose. 2. Remove the outlet grille and install the exhaust tube by rotating it clockwise onto the rear air outlet. Please ensure it is fully inserted before use. To remove the exhaust hose, please rotate in an anti-clockwise direction. Locating the unit. Install the portable air conditioner in a flat location with adequate space to ensure the air inlets and outlets will not be blocked. Keep a minimum clearance of 50cm from walls and other objects. Position the unit to allow the exhaust hose to reach a suitable window, as shown. Avoid sharp bends or kinks in the exhaust hose. The optional adjustable window slider is included to ensure the exhaust hose is held in place (in the window) and prevents expelled hot air re-entering the room. The appliance should not be used in damp areas such as a laundry or bathroom. Do not place the unit where it will be in direct sunlight as it may overheat and turn off. 7

ADJUSTABLE WINDOW SLIDER KIT The adjustable window slider kit is installed as shown below. HEATING / COOLING / DEHUMIDIFYING When using the heating function, remove the exhaust hose (Fig. 2) and replace the opening (Fig. 3) with the outlet grille as shown in Fig. 4. On the opposite end, install the exhaust hose attachment (Fig. 2) onto the unit s grille as shown in Fig.3. Attach the exhaust hose (Fig.4) onto the exhaust hose attachment (Fig. 2) by rotating it in a clockwise direction. 8

Once complete, ensure the outlet exhaust is attached to the window when using the heating function. Reverse the process for cooling or dehumidification. HUMIDIFYING When using the humidifying function, remove the exhaust hose and fix the outlet grille on the unit. 1. Fill the water filler and select humidifier function. 2. The unit will stop automatically after four hours of operation. Put water into the water filler to restart operation. 3. The unit will stop humidifying if the ambient humidity is equal to the pre-set humidity. WATER DRAIN (Error code E4) When the air conditioner is used, excess water condensation may be produced that will fill the water tank. When the water tank is full, the unit will stop working and display an E4 error code. This means the unit will need to be drained as follows: 1. Switch off and unplug the unit. 2. Remove the water tank and pour out the water. 3. Put the water tank back to original position. 4. Restart the unit. CONTINUOUS DRAINAGE To continually drain the unit in dehumidifying mode, follow below steps: 1. Switch off and unplug the unit. 2. Remove the water tank and pour out the water. 3. Remove drain plug (Fig.1) 4. Plug draining tube to draining hole (Fig.2) 5. Put the water tank back to original position. 9

6. Draining tube should be placed lower than the draining hole to allow the water to flow out effectively. MAINTENANCE WARNING: ALWAYS UNPLUG THE UNIT BEFORE MOVING OR CLEANING. CLEANING Air filters The air filters are located on the left and right side of the unit. To remove the air filters, please follows the arrow directions below by pulling out the filters in an upward direction. Clean only with warm soapy water. Cabinet As with filters, clean only with warm soapy water. 10

CARE OF THE UNIT 1. Only plug the unit into a suitable 220-240V~ 50Hz AC 10 AMP power supply. 2. Hold the plug when unplugging the unit, never pull on the cord. 3. Do not place the unit in direct sunlight. This can fade the plastic case. 4. Do not operate the unit in a confined space. 5. Do not place objects on top of the unit. This blocks the air outlet. 6. Do not place the unit where the air inlets or outlets may be blocked by curtains or furniture. 7. Keep the filters clean. OVERHEAT PROTECTION This unit is fitted with an overheat prevention device. If the unit overheats it will automatically turn off. The unit can be restarted after 30 minutes. ERROR CODES Error codes are shown on the display should a fault occur. E1: Indicates open circuit or short circuit in the room temperature sensor. E2: Indicates open circuit or short circuit in the pipe temperature sensor. E3: Indicates a refrigerant leak. Please contact an authorized service centre if any of the above error messages are shown. E4: Indicates the water tank is full. Refer to WATER DRAIN. If error code E4 persists, please contact an authorized service centre. 11

TROUBLE SHOOTING Never try to repair or dismantle the air conditioner yourself. Unauthorized repairs may result in the loss of warranty and can endanger the user and their property. Problem Cause Solution The air conditioner does not operate. No power supply. Error code E4 is shown, indicating the internal water container is full. The start timer function is active. Connect to a functioning power supply socket and switch on. Empty the internal water container. (Refer to WATER DRAIN) Press the POWER button to deactivate the TIMER function. The air conditioner is in direct sunlight. Close the curtains. The air conditioner does not seem to operate efficiently. The air conditioner is noisy. The compressor does not work. The remote control does not function. Windows or doors are open. The filters are dirty. The air inlets or outlets are blocked. The room temperature is below the set temperature. The air conditioner is not level. The overheat protection is activated. The distance between the remote control and the air conditioner is too far. The batteries are flat. Close windows and doors. Clean the filters. Remove the blockage. Lower set temperature. Place the air conditioner on an even, solid surface. Wait 30 minutes until the temperature has decreased, then restart the air conditioner. Note: Compressor operation begins 3 minutes after the unit is switched on. Move closer to the air conditioner. Aim the remote control directly at the control panel. Replace the batteries. If you have any issues with your unit, please contact Glen Dimplex on 1300 556 816 for your nearest service agent. Proof of purchase is required at the time of service. 12

WARRANTY The warranty period is 24 months from the date of purchase. Glen Dimplex Australia Pty Ltd. Unit 1, 21 Lionel Road. Glen Dimplex New Zealand Ltd. 38 Harris Road, East Tamaki, Mount Waverley VIC 3149. Manukau, Auckland 2013 Australia New Zealand Ph: 1300 556 816 Ph: (09) 274 8265 Fax: 1800 058 900 Fax: (09) 274 8472 Web: www.dimplex.com.au Web: www.dimplex.co.nz DISPOSAL Do not dispose of electrical appliances as unsorted municipal waste. Use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the ground water, polluting the food chain and damaging health and well-being. 13

SPECIFICATION Model No. DC10RCDH DC12RCDH Power Source 220-240V~50Hz 220-240V~50Hz Power Consumption (EN14511) Rated Power (EN60335) Cooling/Heating Capacity Humidifying Capacity 1153W/967W 1280W/1100W 3000W/3000W 0.2L/H 1346W/1129W 1480W/1300W 3500W/3500W 0.2L/H Air Flow 360M³/H 450M³/H Moisture Removed Water Tank Capacity 50 L/day 60 L/day 2.4L 2.4L Refrigerant R410A R410A Min. room size 10m³ 10m³ Max. room size 22m³ 25m³ Dimensions (mm) 330Wx477Dx630H 330Wx477Dx630H Net Weight 28KG 29.5KG 14