DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Similar documents
DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

INSTALLATION INSTRUCTIONS

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia

SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO.

INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

INSTALLATION INSTRUCTIONS

MULTI-SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA-

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Compact 4-way Cassette ( ) Type

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

TEST RUN SERVICE MANUAL

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

Digital Inverter 4 series 8 & 10HP

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

TECHNICAL & SERVICE MANUAL WIRED REMOTE CONTROLLER STK-RCS-7TWSUA FILE NO. Product Code No Model No. STK-RCS-7TWSUA

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Concealed Ducted Split Series R-407C MBH

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

EDUS Heat Pump - D-Series

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SPLIT SYSTEM AIR CONDITIONER

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Wall Mounted Split Systems

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

DESIGN & TECHNICAL MANUAL

SERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation

IMPORTANT SAFETY NOTICE

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SPLIT SYSTEM AIR CONDITIONER

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

TECHNICAL DATA & SERVICE MANUAL

Installation Instructions

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

AIR-CONDITIONER SERVICE MANUAL

MINI 2-WAY VARIABLE REFRIGERANT FLOW (VRF) SYSTEM

Air Conditioners. Technical Data RZQG-L

TABLE OF CONTENTS. Air Conditioner

Transcription:

TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XS171 (PNRXS187) XS187 (PNRXS187) Product Code No. Body (Panel) 1 85 35 10 (1 85 35 11) 1 85 35 09 (1 85 35 11) Outdoor Model No. C171 C187 CL171 CL187 Product Code No. 1 85 330 4 1 85 330 36 1 85 330 6 1 85 330 40 Indoor Unit Outdoor Unit Body Panel XS171 (Body) & PNRXS187 (Panel) XS187 (Body) & PNRXS187 (Panel) C171 CL171 Wireless Remote Controller Wired Remote Controller (Option) C187 CL187 REFERENCE NO. SM700767

Important! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. For safe installation and troublefree operation, you must: Carefully read this instruction booklet before beginning. Follow each installation or repair step exactly as shown. Observe all local, state, and national electrical codes. Pay close attention to all warning and caution notices given in this manual. This symbol refers to a hazard or WARNING unsafe practice which can result in severe personal injury or death. CAUTION SPECIAL PRECAUTIONS WARNING When Wiring This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. If Necessary, Get Help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions. In Case of Improper Installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document. ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM. Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked. Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death. Ground the unit following local electrical codes. Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard. Install a protective leakage breaker depending on the installation location (especially a damp or humid location). If a leakage breaker is not installed, electric shock can occur. When Transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers. When Installing In a Ceiling or Wall Make sure the ceiling/wall is strong enough to hold the unit s weight. It may be necessary to construct a strong wood or metal frame to provide added support. In a Room Properly insulate any tubing run inside a room to prevent "sweating" that can cause dripping and water damage to walls and floors. In Moist or Uneven Locations Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration. In an Area with High Winds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle. In a Snowy Area (for Heat Pumptype Systems) Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents. When Connecting Refrigerant Tubing Use the flare method for connecting tubing. Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leakfree connection. Check carefully for leaks before starting the test run. When Servicing Turn the power off at the main power box (mains) before opening the unit to check or repair electrical parts and wiring. Keep your fingers and clothing away from any moving parts. Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced. Others CAUTION Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas. Confirm upon completing installation that no refrigerant gas is leaking. If escaped gas comes in contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas.

Table of Contents Page 1. OPERATING RANGE... 5. SPECIFICATIONS 1. Unit Specifications.... Major Component Specifications... 3. Other Component Specifications... 3. DIMENSIONAL DATA... 4. REFRIGERANT FLOW DIAGRAM 41. Refrigerant Flow Diagram... 5. PERFORMANCE DATA 51. Temperature Charts... 5. Cooling Capactiy... 53. Cooling Capactiy (Low Ambient)... 6. ELECTRICAL DATA 61. Electrical Characteristics 6. Electric Wiring Diagrams 7. MAINTENANCE 71. Address Setting of the Remote Control Unit... 7. Disconnecting and Connecting Positive Connector for Outdoor Unit... 73. Disassembly Procedure... 8. FUNCTIONS 81. Operation Functions 8. Protective Functions............ 9. TROUBLESHOOTING 91. Precautions before Performing Inspection or Repair... 9. Method of SelfDiagnostics... 93. Checking the Indoor and Outdoor Units... 94. Trouble Diagnosis of Fan Motor... 95. Noise Malfunction and Electromagnetic Interference... 6 18 4 5 8 30 3 34 36 38 4 43 44 51 53 54 54 56 60 6 3

Page 10. CHECKING ELECTRICAL COMPONENTS 101. Measurement of Insulation Resistance... 10. Checking Continuity of Fuse on PCB Ass'y... 11. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT 111. Characteristics of New Refrigerant R410A... 11. Checklist before Servicing... 113. Tools Specifically for R410A... 114. Tubing Installation Procedures... 115. In Case of Compressor Malfunction... 116. In Case Refrigerant is Leaking... 117. Charging Additional Refrigerant... 118. RetroFitting Existing Systems... 63 64 65 66 67 67 68 70 71 71 APPENDIX A APPENDIX B INSTRUCTION MANUAL... XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 ( XS187 & PNRXS187 + C187 XS187 & PNRXS187 + CL187 ) INSTALLATION INSTRUCTIONS... XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 ( XS187 & PNRXS187 + C187 XS187 & PNRXS187 + CL187 ) A1 A APPENDIX C INSTRUCTION MANUAL (STKRCS7TWSU)... A3 APPENDIX D INSTALLATION INSTRUCTIONS (STKRCS7TWSU)... A4 4

1. OPERATING RANGE Models : XS171 & PNRXS187 + C171 XS187 & PNRXS187 + C187 Cooling Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum Minimum 95 F D.B. / 71 F W.B. 67 F D.B. / 57 F W.B. 115 F D.B. 67 F D.B. Models : XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CL187 Cooling Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum Minimum 95 F D.B. / 71 F W.B. 67 F D.B. / 57 F W.B. 115 F D.B. 0 F D.B. 5

. SPECIFICATIONS 1. Unit Specifications 11. Performance Electrical Rating Features Indoor Unit Outdoor Unit Voltage Rating XS171 & PNRXS187 C171 115V SinglePhase 60Hz Total Capacity BTU/h kw 11,900 3.5 Cooling ( 3,000 to 11,900 ) ( 0.9 to 3.5 ) Sensible Capacity Latent Capacity BTU/h BTU/h 7,00 4,700 Air Circulation (High) ft 3 /min (m 3 /h) 35 (400) Moisture Removal (High) Pints/h 4.6 Available Voltage Range V 104 to 16 Running Amperes Power Input A W 1.6 1,60 (.5 to 1.6 ) ( 50 to 1,60 ) Power Factor % 87 EER BTU/h/W 9.44 SEER BTU/Wh 16 Compressor Locked Rotor Amperes A 0 Fuse or Circuit Breaker Capacity A 0 Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 4Hour ON or OFF Timer, 1Hour OFF Timer Fan Speeds Indoor / Outdoor Auto and 3 steps / Auto (Hi, Me, Lo) Airflow Direction (Indoor) Horizontal Vertical Auto Air Filter Compressor Washable, AntiMold DC Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R410A /.43 (1,100) Refrigerant Control Electric Expansion Valve Operation Sound Indoor : Hi/Me/Lo Outdoor : Hi dba dba 34 / 3 / 31 47 Refrigerant Tubing Connections Flare Type Max. allowable tubing length at shipment ft (m) 5 (7.5) Refrigerant Narrow tube 1/4 (6.35) Tube Diameter Wide tube 3/8 (9.5) Accessories Air Clean Filter Wired Remote Controller (Option) STKRCS7TWSU 6

Indoor Unit Outdoor Unit XS171 & PNRXS187 C171 Dimensions & Weight (Indoor Unit) Unit Dimensions Package Dimensions Weight Shipping Volume Dimensions & Weight (Outdoor Unit) Unit Dimensions Package Dimensions Weight Shipping Volume Height 15/16 (313) 115/3 (83) Width 419/3 (65) 5/8 (575) Depth 419/3 (65) 5/8 (575) Height 1113/3 (90) Width 413/16 (630) Depth 81/8 (714) Net Shipping Ib. (kg) Ib. (kg) 41.3 (18.7) 35.3 (16) 41.9 (19) cu.ft (m 3 ) 4.59 (0.13) Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F D.B. / 67 F W.B. Outdoor air temperature 95 F D.B. / 75 F W.B. Indoor Unit (XS171 & PNRXS187) Outdoor Unit (C171) 19/16 (548) 811/3 (70) 107/16 (65) 35/8 (600) 3311/16 (856) 141/4 (36) 75.0 (34.0) 81.6 (37.0) 6.35 (0.18) Body (XS171) Individual Unit Panel (PNRXS187) 19/16 (40) 419/3 (65) 419/3 (65) 41/8 (105) 63/16 (665) 611/16 (678) 6.0 (.7) 7.7 (3.5) 1.65 (0.04) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 7

1. Performance Electrical Rating Features Indoor Unit Outdoor Unit Voltage Rating XS187 & PNRXS187 C187 30V SinglePhase 60Hz Total Capacity BTU/h kw 17,500 5.15 Cooling ( 4,000 to 17,500 ) ( 1. to 5.15 ) Sensible Capacity Latent Capacity BTU/h BTU/h 10,600 6,900 Air Circulation (High) ft 3 /min (m 3 /h) 341 (580) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 53 Running Amperes Power Input A W 8.3 1,860 ( 1. to 8.3 ) ( 50 to 1,860 ) Power Factor % 97 EER BTU/h/W 9.41 SEER BTU/Wh 16 Compressor Locked Rotor Amperes A 17.5 Fuse or Circuit Breaker Capacity A 0 Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 4Hour ON or OFF Timer, 1Hour OFF Timer Fan Speeds Indoor / Outdoor Auto and 3 steps / Auto (Hi, Me, Lo) Airflow Direction (Indoor) Horizontal Vertical Auto Air Filter Compressor Washable, AntiMold DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R410A /.87 (1,300) Refrigerant Control Electric Expansion Valve Operation Sound Indoor : Hi/Me/Lo Outdoor : Hi dba dba 44 / 40 / 36 51 Refrigerant Tubing Connections Flare Type Max. allowable tubing length at shipment ft (m) 5 (7.5) Refrigerant Narrow tube 1/4 (6.35) Tube Diameter Wide tube 1/ (1.7) Accessories Air Clean Filter Wired Remote Controller (Option) STKRCS7TWSU < 30V > 8

Indoor Unit Outdoor Unit XS187 & PNRXS187 C187 Dimensions & Weight (Indoor Unit) Indoor Unit (XS187 & PNRXS187) Body (XS187) < 30V > Individual Unit Panel (PNRXS187) Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) 15/16 (313) 419/3 (65) 419/3 (65) 41.3 (18.7) 115/3 (83) 5/8 (575) 5/8 (575) 1113/3 (90) 413/16 (630) 81/8 (714) 35.3 (16) 41.9 (19) 4.59 (0.13) 19/16 (40) 419/3 (65) 419/3 (65) 41/8 (105) 63/16 (665) 611/16 (678) 6.0 (.7) 7.7 (3.5) 1.65 (0.04) Dimensions & Weight (Outdoor Unit) Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F D.B. / 67 F W.B. Outdoor air temperature 95 F D.B. / 75 F W.B. Outdoor Unit (C187) 63/8 (670) 341/3 (880) 117/3 (85) 91/8 (740) 397/3 (1,01) 1431/3 (380) 90.4 (41.0) 99. (45.0) 9.88 (0.8) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 9

13. Performance Electrical Rating Features Indoor Unit Outdoor Unit Voltage Rating XS187 & PNRXS187 C187 08V SinglePhase 60Hz Total Capacity BTU/h kw 17,500 5.15 Cooling ( 4,000 to 17,500 ) ( 1. to 5.15 ) Sensible Capacity Latent Capacity BTU/h BTU/h 10,600 6,900 Air Circulation (High) ft 3 /min (m 3 /h) 341 (580) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 53 Running Amperes Power Input A W 9.1 1,860 ( 1. to 9.1 ) ( 50 to 1,860 ) Power Factor % 98 EER BTU/h/W 9.41 SEER BTU/Wh 16 Compressor Locked Rotor Amperes A 17.5 Fuse or Circuit Breaker Capacity A 0 Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 4Hour ON or OFF Timer, 1Hour OFF Timer Fan Speeds Indoor / Outdoor Auto and 3 steps / Auto (Hi, Me, Lo) Airflow Direction (Indoor) Horizontal Vertical Auto Air Filter Compressor Washable, AntiMold DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R410A /.87 (1,300) Refrigerant Control Electric Expansion Valve Operation Sound Indoor : Hi/Me/Lo Outdoor : Hi dba dba 44 / 40 / 36 51 Refrigerant Tubing Connections Flare Type Max. allowable tubing length at shipment ft (m) 5 (7.5) Refrigerant Narrow tube 1/4 (6.35) Tube Diameter Wide tube 1/ (1.7) Accessories Air Clean Filter Wired Remote Controller (Option) STKRCS7TWSU < 08V > 10

Indoor Unit Outdoor Unit XS187 & PNRXS187 C187 Dimensions & Weight (Indoor Unit) Indoor Unit (XS187 & PNRXS187) Body (XS187) < 08V > Individual Unit Panel (PNRXS187) Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) 15/16 (313) 419/3 (65) 419/3 (65) 41.3 (18.7) 115/3 (83) 5/8 (575) 5/8 (575) 1113/3 (90) 413/16 (630) 81/8 (714) 35.3 (16) 41.9 (19) 4.59 (0.13) 19/16 (40) 419/3 (65) 419/3 (65) 41/8 (105) 63/16 (665) 611/16 (678) 6.0 (.7) 7.7 (3.5) 1.65 (0.04) Dimensions & Weight (Outdoor Unit) Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F D.B. / 67 F W.B. Outdoor air temperature 95 F D.B. / 75 F W.B. Outdoor Unit (C187) 63/8 (670) 341/3 (880) 117/3 (85) 91/8 (740) 397/3 (1,01) 1431/3 (380) 90.4 (41.0) 99. (45.0) 9.88 (0.8) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 11

14. Indoor Unit Outdoor Unit XS171 & PNRXS187 CL171 Performance Electrical Rating Features Voltage Rating 115V SinglePhase 60Hz Total Capacity BTU/h kw 11,900 3.5 Cooling ( 3,000 to 11,900 ) ( 0.9 to 3.5 ) Sensible Capacity Latent Capacity BTU/h BTU/h 7,00 4,700 Air Circulation (High) ft 3 /min (m 3 /h) 35 (400) Moisture Removal (High) Pints/h 4.6 Available Voltage Range V 104 to 16 Running Amperes Power Input A W 1.6 1,60 (.5 to 1.6 ) ( 50 to 1,60 ) Power Factor % 87 EER BTU/h/W 9.44 SEER BTU/Wh 16 Compressor Locked Rotor Amperes A 0 Fuse or Circuit Breaker Capacity A 0 Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 4Hour ON or OFF Timer, 1Hour OFF Timer Fan Speeds Indoor / Outdoor Auto and 3 steps / Auto (Hi and multi steps) Airflow Direction (Indoor) Horizontal Vertical Auto Air Filter Compressor Washable, AntiMold DC Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R410A /.43 (1,100) Refrigerant Control Electric Expansion Valve Operation Sound Indoor : Hi/Me/Lo Outdoor : Hi dba dba 34 / 3 / 31 47 Refrigerant Tubing Connections Flare Type Max. allowable tubing length at shipment ft (m) 5 (7.5) Refrigerant Narrow tube 1/4 (6.35) Tube Diameter Wide tube 3/8 (9.5) Accessories Air Clean Filter Wired Remote Controller (Option) STKRCS7TWSU 1

Indoor Unit Outdoor Unit XS171 & PNRXS187 CL171 Dimensions & Weight (Indoor Unit) Unit Dimensions Package Dimensions Weight Shipping Volume Dimensions & Weight (Outdoor Unit) Unit Dimensions Package Dimensions Weight Shipping Volume Height 15/16 (313) 115/3 (83) Width 419/3 (65) 5/8 (575) Depth 419/3 (65) 5/8 (575) Height 1113/3 (90) Width 413/16 (630) Depth 81/8 (714) Net Shipping Ib. (kg) Ib. (kg) 41.3 (18.7) 35.3 (16) 41.9 (19) cu.ft (m 3 ) 4.59 (0.13) Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F D.B. / 67 F W.B. Outdoor air temperature 95 F D.B. / 75 F W.B. Indoor Unit (XS171 & PNRXS187) Outdoor Unit (CL171) 19/16 (548) 811/3 (70) 107/16 (65) 35/8 (600) 3311/16 (856) 141/4 (36) 75.0 (34.0) 81.6 (37.0) 6.35 (0.18) Body (XS171) Individual Unit Panel (PNRXS187) 19/16 (40) 419/3 (65) 419/3 (65) 41/8 (105) 63/16 (665) 611/16 (678) 6.0 (.7) 7.7 (3.5) 1.65 (0.04) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 13

15. Performance Electrical Rating Features Indoor Unit Outdoor Unit Voltage Rating XS187 & PNRXS187 CL187 30V SinglePhase 60Hz Total Capacity BTU/h kw 17,500 5.15 Cooling ( 4,000 to 17,500 ) ( 1. to 5.15 ) Sensible Capacity Latent Capacity BTU/h BTU/h 10,600 6,900 Air Circulation (High) ft 3 /min (m 3 /h) 341 (580) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 53 Running Amperes Power Input A W 8.3 1,860 ( 1. to 8.3 ) ( 50 to 1,860 ) Power Factor % 97 EER BTU/h/W 9.41 SEER BTU/Wh 16 Compressor Locked Rotor Amperes A 17.5 Fuse or Circuit Breaker Capacity A 0 Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 4Hour ON or OFF Timer, 1Hour OFF Timer Fan Speeds Indoor / Outdoor Auto and 3 steps / Auto (Hi and multi steps) Airflow Direction (Indoor) Horizontal Vertical Auto Air Filter Compressor Washable, AntiMold DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R410A /.87 (1,300) Refrigerant Control Electric Expansion Valve Operation Sound Indoor : Hi/Me/Lo Outdoor : Hi dba dba 44 / 40 / 36 51 Refrigerant Tubing Connections Flare Type Max. allowable tubing length at shipment ft (m) 5 (7.5) Refrigerant Narrow tube 1/4 (6.35) Tube Diameter Wide tube 1/ (1.7) Accessories Air Clean Filter Wired Remote Controller (Option) STKRCS7TWSU < 30V > 14

Indoor Unit Outdoor Unit XS187 & PNRXS187 CL187 Dimensions & Weight (Indoor Unit) Indoor Unit (XS187 & PNRXS187) Body (XS187) < 30V > Individual Unit Panel (PNRXS187) Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) 15/16 (313) 419/3 (65) 419/3 (65) 41.3 (18.7) 115/3 (83) 5/8 (575) 5/8 (575) 1113/3 (90) 413/16 (630) 81/8 (714) 35.3 (16) 41.9 (19) 4.59 (0.13) 19/16 (40) 419/3 (65) 419/3 (65) 41/8 (105) 63/16 (665) 611/16 (678) 6.0 (.7) 7.7 (3.5) 1.65 (0.04) Dimensions & Weight (Outdoor Unit) Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F D.B. / 67 F W.B. Outdoor air temperature 95 F D.B. / 75 F W.B. Outdoor Unit (CL187) 63/8 (670) 341/3 (880) 117/3 (85) 91/8 (740) 397/3 (1,01) 1431/3 (380) 90.4 (41.0) 99. (45.0) 9.88 (0.8) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 15

16. Performance Electrical Rating Features Indoor Unit Outdoor Unit Voltage Rating XS187 & PNRXS187 CL187 08V SinglePhase 60Hz Total Capacity BTU/h kw 17,500 5.15 Cooling ( 4,000 to 17,500 ) ( 1. to 5.15 ) Sensible Capacity Latent Capacity BTU/h BTU/h 10,600 6,900 Air Circulation (High) ft 3 /min (m 3 /h) 341 (580) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 53 Running Amperes Power Input A W 9.1 1,860 ( 1. to 9.1 ) ( 50 to 1,860 ) Power Factor % 98 EER BTU/h/W 9.41 SEER BTU/Wh 16 Compressor Locked Rotor Amperes A 17.5 Fuse or Circuit Breaker Capacity A 0 Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 4Hour ON or OFF Timer, 1Hour OFF Timer Fan Speeds Indoor / Outdoor Auto and 3 steps / Auto (Hi and multi steps) Airflow Direction (Indoor) Horizontal Vertical Auto Air Filter Compressor Washable, AntiMold DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R410A /.87 (1,300) Refrigerant Control Electric Expansion Valve Operation Sound Indoor : Hi/Me/Lo Outdoor : Hi dba dba 44 / 40 / 36 51 Refrigerant Tubing Connections Flare Type Max. allowable tubing length at shipment ft (m) 5 (7.5) Refrigerant Narrow tube 1/4 (6.35) Tube Diameter Wide tube 1/ (1.7) Accessories Air Clean Filter Wired Remote Controller (Option) STKRCS7TWSU < 08V > 16

Indoor Unit Outdoor Unit XS187 & PNRXS187 CL187 Dimensions & Weight (Indoor Unit) Indoor Unit (XS187 & PNRXS187) Body (XS187) < 08V > Individual Unit Panel (PNRXS187) Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) 15/16 (313) 419/3 (65) 419/3 (65) 41.3 (18.7) 115/3 (83) 5/8 (575) 5/8 (575) 1113/3 (90) 413/16 (630) 81/8 (714) 35.3 (16) 41.9 (19) 4.59 (0.13) 19/16 (40) 419/3 (65) 419/3 (65) 41/8 (105) 63/16 (665) 611/16 (678) 6.0 (.7) 7.7 (3.5) 1.65 (0.04) Dimensions & Weight (Outdoor Unit) Unit Dimensions Package Dimensions Weight Shipping Volume Height Width Depth Height Width Depth Net Shipping Ib. (kg) Ib. (kg) cu.ft (m 3 ) Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F D.B. / 67 F W.B. Outdoor air temperature 95 F D.B. / 75 F W.B. Outdoor Unit (CL187) 63/8 (670) 341/3 (880) 117/3 (85) 91/8 (740) 397/3 (1,01) 1431/3 (380) 90.4 (41.0) 99. (45.0) 9.88 (0.8) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 17

. Major Component Specifications 1. Indoor Unit Indoor Unit (Body) XS171 Control PCB Part No. Controls Control Circuit Fuse Remote Control Unit CBXS171 Microprocessor 50V 3A RCS7MVPS4U Fan Type Q'ty... Dia. and Length Turbo 1... D15/8 / L53/4 (D3/L147) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Rating Voltage / Nominal Output Coil Resistance Ohm (Ambient Temp. 68 F (0 C)) Safety Device Type Over Current Protection Over Heat Protection Run Capacitor Micro F VAC DC Motor SIC7FVB631... 1 8 470 DC160V / 3W Internal Controller Yes Yes Drain Pump Model... Q'ty Rating Voltage, Hz Input Coil Resistance (Ambient Temp. 68 F (0 C)) Safty Device Type Open Heat Exchanger Coil Coil Rows Fins per inch Face Area W Ohm F ( C) ft (m ) PLD1115ST1... 1 AC115V, 60Hz 10.8 101 +/ 10% Thermal Fuse 93 (145) Aluminum Plate Fin / Copper Tube 18.1.94 (0.73) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Indoor Unit (Panel) PNRXS187 Flap Motor Type Model... Q'ty Rating Coil Resistance (Ambient Temp. 77 F (5 C)) Ohm 18 Stepping Motor MP4ZN1V... DC 1V Each Pair of Terminal : 380 +/ 7% DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Indoor Unit (Body) XS187 Control PCB Part No. Controls Control Circuit Fuse Remote Control Unit CBXS187 Microprocessor 50V 3A RCS7MVPS4U Fan Type Q'ty... Dia. and Length Turbo 1... D15/8 / L53/4 (D3/L147) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Rating Voltage / Nominal Output Coil Resistance Ohm (Ambient Temp. 68 F (0 C)) Safety Device Type Over Current Protection Over Heat Protection Run Capacitor Micro F VAC DC Motor SIC7FVD8661B... 1 8 650 DC340V / 0W Internal Controller Yes Yes Drain Pump Model... Q'ty Rating Coil Resistance (Ambient Temp. 68 F (0 C)) Safty Device Type Open Heat Exchanger Coil Coil Rows Fins per inch Face Area Voltage, Hz Input W Ohm F ( C) ft (m ) PLD130ST1... 1 AC08 to 40V, 60Hz 10.8 333 +/ 10% Thermal Fuse 93 (145) Aluminum Plate Fin / Copper Tube 18.1.94 (0.73) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Indoor Unit (Panel) PNRXS187 Flap Motor Type Model... Q'ty Rating Coil Resistance (Ambient Temp. 77 F (5 C)) Ohm 19 Stepping Motor MP4ZN1V... DC 1V Each Pair of Terminal : 380 +/ 7% DATA SUBJECT TO CHANGE WITHOUT NOTICE.

. Outdoor Unit Outdoor Unit C171 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 F (0 C)) Ohm Safety Device CT (Peak current cutoff control) Compressor Discharge Temp. Control Operation cutoff control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Micro F VAC Crankcase Heater CBC171 Microprocessor 15V 5A DC Rotary (Hermetic) G4C090LU1ER / 900W FV50S... 0.68 (30) U V : 0.81 V W : 0.81 W U : 0.81 Yes Yes Yes CS7L115 Open : 39 F (115 C), Close : 03 F (95 C) Fan Type Q'ty... Dia. Propeller 1... D153/4 (D400) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (0 C)) Safety Device Type Over Current Protection Run Capacitor W Ohm Micro F VAC DC Motor DAJ155J71CU... 1 8 750 50 RED WHT : 77.5 WHT BLU : 77.5 BLU RED : 77.5 Internal Controller Yes Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 18.1 Face Area ft (m ) 3.95 (0.367) External Finish Acrylic bakedon enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 0

Outdoor Unit C187 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 F (0 C)) Ohm Safety Device CT (Peak current cutoff control) Compressor Discharge Temp. Control Operation cutoff control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Micro F VAC Crankcase Heater CBC187 Microprocessor 50V 5A DC Twin Rotary (Hermetic) C6RVN93H0M / 1,050W FV50S... 0.74 (350) R S : 0.48 S T : 0.48 T R : 0.48 Yes Yes Yes CS7L115 Open : 39 F (115 C), Close : 03 F (95 C) Fan Type Q'ty... Dia. Propeller 1... D1617/3 (D40) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (0 C)) Safety Device Type Over Current Protection Run Capacitor W Ohm Micro F VAC DC Motor DAJ155J71ACU... 1 8 80 50 RED WHT : 77.5 WHT BLU : 77.5 BLU RED : 77.5 Internal Controller Yes Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 1. Face Area ft (m ) 5.49 (0.510) External Finish Acrylic bakedon enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 1

Outdoor Unit CL171 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 F (0 C)) Ohm Safety Device CT (Peak current cutoff control) Compressor Discharge Temp. Control Operation cutoff control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Micro F VAC Crankcase Heater CBCL171 Microprocessor 15V 5A DC Rotary (Hermetic) G4C090LU1ER / 900W FV50S... 0.68 (30) U V : 0.81 V W : 0.81 W U : 0.81 Yes Yes Yes CS7L115 Open : 39 F (115 C), Close : 03 F (95 C) 115V 0W Fan Type Q'ty... Dia. Propeller 1... D153/4 (D400) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (0 C)) Safety Device Type Over Current Protection Run Capacitor W Ohm Micro F VAC DC Motor DAJ155J71CU... 1 8 750 50 RED WHT : 77.5 WHT BLU : 77.5 BLU RED : 77.5 Internal Controller Yes Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 18.1 Face Area ft (m ) 3.95 (0.367) External Finish Acrylic bakedon enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Outdoor Unit CL187 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 F (0 C)) Ohm Safety Device CT (Peak current cutoff control) Compressor Discharge Temp. Control Operation cutoff control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Micro F VAC Crankcase Heater CBCL187 Microprocessor 50V 5A DC Twin Rotary (Hermetic) C6RVN93H0M / 1,050W FV50S... 0.74 (350) R S : 0.48 S T : 0.48 T R : 0.48 Yes Yes Yes CS7L115 Open : 39 F (115 C), Close : 03 F (95 C) Fan Type Q'ty... Dia. Propeller 1... D1617/3 (D40) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (0 C)) Safety Device Type Over Current Protection Run Capacitor W Ohm Micro F VAC DC Motor DAJ155J71ACU... 1 8 80 50 RED WHT : 77.5 WHT BLU : 77.5 BLU RED : 77.5 Internal Controller Yes Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 1. Face Area ft (m ) 5.49 (0.510) External Finish Acrylic bakedon enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 3

3. Other Component Specifications Indoor Unit XS171 & PNRXS187 XS187 & PNRXS187 Outdoor Unit C171 C187 CL171 CL187 Indoor air temp sensor (Model:KTEC35S98) Indoor heat exchanger sensor (Model:PTM51HS3) Compressor temp sensor (C171, CL171... Model:DTNTKS74Y TH) (C187, CL187... Model:DTNTKS93B) Resistance (k ohm) 10 9 8 7 6 5 4 3 1 0 50 59 68 77 86 95 104 (10) (15) (0) (5) (30) (35) (40) Temperature F ( C) Resistance (k ohm) 00 180 160 140 10 100 80 60 40 0 0 3 50 68 86 104 1 140 158 176 194 (0) (10) (0) (30) (40) (50) (60) (70) (80) (90) Temperature F ( C) Outdoor air temp sensor (C171, CL171... Model:DTNTKS69B) (C187, CL187... Model:TKS95B) Outdoor heat exchanger sensor (C171, CL171... Model:DTNTKS74Y TH1) (C187, CL187... Model:TKS9B) 40 Resistance (k ohm) 35 30 5 0 15 10 5 0 4 5 14 3 3 41 50 59 68 (0)(15)(10) (5) (0) (5) (10) (15) (0) Temperature F ( C) 4

3. DIMENSIONAL DATA Indoor Unit XS171 & PNRXS187 XS187 & PNRXS187 13/16 (30) 3/3 65/16 611/16 419/3 15/3 15/3 815/3 115/3 (83) 5/8 (575) Less than 31/3 Less than 31/3 11/3 (534) Suspension bolt pitch 5/8 (575) 6 3 419/3 (65) 143/3 (358) 5 35/8 17/8 135/3 (334) 17/16 419/3 (65) 11/3 (534) Suspension bolt pitch 35/8 (600) Ceiling opening dimensions 711/16 13/16 7 1 35/8 (600) Ceiling opening dimensions Center of panel A View 49/3 8 1/3 31/8 1 3 4 5 6 7 8 Air intake Discharge outlet Refrigerant tubing (liquid tube) dia. 1/4" (flared) Refrigerant tubing (gas tube) dia. 1/" (flared) Drain tube connection port VP0 (outer dia. 1") Power supply port Suspension bolt hole (4 1/" x 11/8" hole) Fresh air intake duct connection port (dia. 37/8") 3/3 5/3 A The length of the suspension bolts should be selected so that there is a gap of 13/16" or the ceiling (1/3" or more below the lower surface of the main unit), as shown in the figure at right. If the suspension bolts is too long, it will contact the ceiling panel and the unit cannot be installed. 73/3 3/4 19/3 59/16 17/3 13/3 Unit : 5

Outdoor Unit C171 CL171 13/16 319/3 1013/16 15/3 ID:3/3 ID:15/16 49/3 5/3 319/3 107/16(65) 1113/3 17/16 811/3 (70) 1/8 Wide tube service valve dia.3/8" (9.5) Narrow tube service valve dia.1/4" (6.35) 19/16 (548) 5/8 63/3 Unit : (850001016000) 6

Outdoor Unit C187 CL187 315/16 511/3 13/8 1117/3 ID:3/3 ID:15/16 15/3 341/3 (880) Wide tube service valve dia.1/" (1.70) Narrow tube service valve dia.1/4" (6.35) 3/3 43/8 5/3 617/3 63/8 (670) 117/3 (85) 17/3 135/3 17/3 113/16 3/3 53/3 13/3 Unit : (8500010133000) 7

4. REFRIGERANT FLOW DIAGRAM 41. Refrigerant Flow Diagram Indoor Unit XS171 & PNRXS187 Outdoor Unit C171 CL171 Indoor unit Outdoor unit Wide tube O.D. 3/8" (9.5 mm) Wide tube service valve Muffler Accumulator High pressure switch H.P. Heat exchanger Heat exchanger Compressor Strainer Narrow tube Narrow tube service valve Electric expansion valve M O.D. 1/4" (6.35 mm) Muffler Cooling cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min. 5/16"(8 mm). Thickness: Min. 5/16"(8 mm) Insulation Thickness: Min. 5/16"(8 mm) CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. Wide tube Narrow tube 8

Indoor Unit XS187 & PNRXS187 Outdoor Unit C187 CL187 Indoor unit Outdoor unit Wide tube O.D. 1/" (1.7mm) Wide tube service valve Muffler Accumulator High pressure switch H.P. Compressor Strainer Heat exchanger Heat exchanger Narrow tube Narrow tube service valve Electric expansion valve M O.D. 1/4" (6.35 mm) Cooling cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min. 5/16"(8 mm). Thickness: Min. 5/16"(8 mm) Insulation Thickness: Min. 5/16"(8 mm) CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. Wide tube Narrow tube 9

5. PERFORMANCE DATA 51. Temperature Charts Indoor Unit XS171 & PNRXS187 Outdoor Unit C171 or CL171 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 115V) (1) Low pressure performance chart Low pressure at wide tube service valve psig(mpag) 131 (0.9) 10 (0.7) () Operating current performance chart 73 (0.5) 77 (5) 15 Lo Fan Hi Fan 86 95 (30) (35) Outdoor inlet air D.B. temp. F( C) Lo Fan Indoor Air Temp.86 F (30 C) Hi Fan 80 F (7 C) 75 F (4 C) 104 (40) Operating current (A) 14 13 1 11 80 F (7 C) Indoor Air Temp.86 F (30 C) 75 F (4 C) (3) Indoor discharge air performance chart Indoor discharge air temperature F( C) 10 68 (0) 59 (15) 50 (10) 41 (5) 77 (5) 3 (0) 77 (5) 86 95 (30) (35) Outdoor inlet air D.B. temp. F( C) Lo Fan Hi Fan Indoor Air Temp.86 F (30 C) 80 F (7 C) 75 F (4 C) 86 95 (30) (35) Outdoor inlet air D.B. temp. F( C) 104 (40) 104 (40) NOTE Check each performance value in testrun mode. Electrical performance values represent a combined indoor/outdoor value. 30

Indoor Unit XS187 & PNRXS187 Outdoor Unit C187 or CL187 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 30V) (1) Low pressure performance chart Low pressure at wide tube service valve psig(mpag) () Operating current performance chart Operating current (A) 131 (0.9) 10 (0.7) 73 (0.5) 77 (5) 10 9 8 7 6 Lo Fan Hi Fan 86 95 (30) (35) Outdoor inlet air D.B. temp. F( C) Lo Fan Indoor Air Temp.86 F (30 C) Hi Fan 80 F (7 C) 75 F (4 C) 80 F (7 C) Indoor Air Temp.86 F (30 C) 75 F (4 C) 104 (40) (3) Indoor discharge air performance chart Indoor discharge air temperature F( C) 5 68 (0) 59 (15) 50 (10) 41 (5) 77 (5) 3 (0) 77 (5) 86 95 (30) (35) Outdoor inlet air D.B. temp. F( C) Lo Fan Hi Fan 86 95 (30) (35) Outdoor inlet air D.B. temp. F( C) 104 (40) Indoor Air Temp.86 F (30 C) 80 F (7 C) 75 F (4 C) 104 (40) NOTE Check each performance value in testrun mode. Electrical performance values represent a combined indoor/outdoor value. 31

5. Cooling Capacity Indoor Unit : XS171 & PNRXS187 Outdoor Unit : C171 or CL171 Power Supply : 115V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY: 11,900 BTU/h AIR FLOW RATE: 35 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C) W.B. D.B. 65 75 85 95 105 115 (18.3) (3.9) (9.4) (35.0) (40.6) (46.1) NOTE TC 11,940 11,70 11,460 11,0 10,440 7,840 CI 0.80 0.93 1.06 1.16 1.5 1.07 7 (.) SHC 8,10 8,080 7,940 7,800 7,340 5,970 59 76 (4.4) SHC 9,040 8,900 8,760 8,60 8,170 6,800 (15.0) 80 (6.7) SHC 9,910 9,770 9,590 9,450 9,040 7,660 84 (8.9) SHC 10,730 10,590 10,410 10,70 9,860 7,840 88 (31.1) SHC 11,550 11,410 11,80 11,090 10,440 7,840 TC 1,30 1,030 11,790 11,580 10,600 7,970 CI 0.81 0.95 1.08 1.18 1.5 1.07 7 (.) SHC 7,00 6,930 6,800 6,660 6,160 4,90 63 76 (4.4) SHC 7,850 7,760 7,60 7,480 6,980 5,740 (17.) 80 (6.7) SHC 8,70 8,60 8,490 8,350 7,850 6,610 84 (8.9) SHC 9,540 9,450 9,310 9,170 8,670 7,440 88 (31.1) SHC 10,360 10,70 10,130 10,000 9,490 7,970 TC 1,470 1,300 1,070 # 11,900 10,70 8,060 CI 0.83 0.97 1.11 1.0 1.5 1.07 7 (.) SHC 5,840 5,740 5,610 5,50 4,970 3,80 67 76 (4.4) SHC 6,660 6,570 6,430 6,380 5,790 4,650 (19.4) 80 (6.7) SHC 7,480 7,440 7,300 7,10 6,660 5,50 84 (8.9) SHC 8,350 8,60 8,10 8,030 7,480 6,340 88 (31.1) SHC 9,170 9,080 8,940 8,900 8,300 7,160 TC 1,660 1,510 1,310 1,180 10,790 8,130 CI 0.85 0.99 1.13 1.3 1.5 1.07 7 (.) SHC 4,510 4,460 4,370 4,330 3,730,730 71 76 (4.4) SHC 5,380 5,90 5,00 5,150 4,560 3,550 (1.7) 80 (6.7) SHC 6,00 6,160 6,060 6,00 5,40 4,40 84 (8.9) SHC 7,00 6,980 6,890 6,840 6,50 5,40 88 (31.1) SHC 7,890 7,800 7,710 7,660 7,070 6,060 TC 1,750 1,640 1,470 1,390 10,800 8,150 CI 0.87 1.01 1.16 1.5 1.5 1.07 75 76 (4.4) SHC 4,100 4,050 4,010 3,960 3,370,500 (3.9) 80 (6.7) SHC 4,970 4,90 4,880 4,830 4,40 3,30 84 (8.9) SHC 5,790 5,740 5,700 5,650 5,060 4,140 88 (31.1) SHC 6,610 6,570 6,50 6,480 5,880 4,970 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 F (6.7 C) D.B. / 67 F (19.4 C) W.B. : Outdoor Ambient Temp. 95 F (35 C) D.B.. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics. 3. Above data represents the value when the operation frequency of a compressor is fixed. 3

Indoor Unit : XS187 & PNRXS187 Outdoor Unit : C187 or CL187 Power Supply : 30V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY: 17,500 BTU/h AIR FLOW RATE: 341 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C) W.B. D.B. 65 75 85 95 105 115 (18.3) (3.9) (9.4) (35.0) (40.6) (46.1) NOTE TC 17,650 17,300 16,900 16,470 15,90 10,50 CI 1.15 1.34 1.54 1.7 1.93 1.41 7 (.) SHC 1,10 11,90 11,660 11,390 11,060 8,140 59 76 (4.4) SHC 13,30 13,10 1,850 1,590 1,30 9,340 (15.0) 80 (6.7) SHC 14,580 14,380 14,110 13,850 13,510 10,50 84 (8.9) SHC 15,770 15,570 15,300 15,040 14,770 10,50 88 (31.1) SHC 16,960 16,760 16,500 16,30 15,90 10,50 TC 18,110 17,790 17,400 17,000 16,470 10,390 CI 1.17 1.37 1.57 1.75 1.97 1.41 7 (.) SHC 10,400 10,00 10,000 9,800 9,540 6,60 63 76 (4.4) SHC 11,590 11,390 11,190 11,000 10,730 7,810 (17.) 80 (6.7) SHC 1,850 1,650 1,450 1,60 11,990 9,070 84 (8.9) SHC 14,040 13,850 13,650 13,450 13,180 10,70 88 (31.1) SHC 15,40 15,110 14,840 14,640 14,380 10,390 TC 18,510 18,0 17,860 # 17,500 16,990 10,500 CI 1.19 1.40 1.60 1.79.01 1.41 7 (.) SHC 8,680 8,480 8,340 8,140 7,880 5,100 67 76 (4.4) SHC 9,870 9,740 9,540 9,340 9,140 6,90 (19.4) 80 (6.7) SHC 11,130 10,930 10,800 10,600 10,400 7,550 84 (8.9) SHC 1,30 1,190 11,990 11,790 11,590 8,740 88 (31.1) SHC 13,510 13,380 13,180 1,980 1,790 9,930 TC 18,80 18,570 18,60 17,940 17,460 10,560 CI 1. 1.43 1.64 1.83.06 1.41 7 (.) SHC 6,750 6,690 6,550 6,40 6,160 3,500 71 76 (4.4) SHC 7,950 7,880 7,750 7,610 7,40 4,700 (1.7) 80 (6.7) SHC 9,10 9,140 9,010 8,870 8,680 5,960 84 (8.9) SHC 10,470 10,330 10,00 10,070 9,870 7,150 88 (31.1) SHC 11,660 11,530 11,390 11,60 11,060 8,340 TC 19,010 18,800 18,530 18,60 17,660 10,570 CI 1.5 1.46 1.68 1.87.09 1.41 75 76 (4.4) SHC 6,160 6,090 5,960 5,890 5,630 3,170 (3.9) 80 (6.7) SHC 7,40 7,350 7,0 7,150 6,890 4,430 84 (8.9) SHC 8,610 8,540 8,410 8,340 8,080 5,630 88 (31.1) SHC 9,800 9,740 9,670 9,540 9,340 6,80 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 F (6.7 C) D.B. / 67 F (19.4 C) W.B. : Outdoor Ambient Temp. 95 F (35 C) D.B.. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics. 3. Above data represents the value when the operation frequency of a compressor is fixed. 33

53. Cooling Capacity (Low Ambient) Indoor Unit : XS171 & PNRXS187 Outdoor Unit : CL171 Power Supply : 115V Single Phase 60Hz < Cooling Capacity (Low Ambient) > RATING CAPACITY: 11,900 BTU/h AIR FLOW RATE: 35 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C) W.B. D.B. 0 5 15 5 35 45 55 (17.8) (15.0) (9.4) (3.9) (1.7) (7.) (1.8) TC 9,50 9,540 9,550 9,570 9,590 9,580 9,570 CI 0.48 0.51 0.48 0.46 0.47 0.5 0.56 7 (.) SHC 6,840 6,840 6,840 6,840 6,890 6,890 6,840 59 76 (4.4) SHC 7,660 7,660 7,660 7,710 7,710 7,710 7,710 (15.0) 80 (6.7) SHC 8,530 8,530 8,530 8,530 8,580 8,530 8,530 84 (8.9) SHC 9,360 9,360 9,360 9,360 9,400 9,360 9,360 88 (31.1) SHC 9,50 9,540 9,550 9,570 9,590 9,580 9,570 TC 9,390 9,40 9,480 9,540 9,600 9,60 9,640 CI 0.54 0.57 0.5 0.50 0.50 0.54 0.58 7 (.) SHC 5,560 5,610 5,610 5,650 5,650 5,700 5,700 63 76 (4.4) SHC 6,380 6,430 6,430 6,480 6,50 6,50 6,50 (17.) 80 (6.7) SHC 7,50 7,50 7,300 7,340 7,340 7,390 7,390 84 (8.9) SHC 8,080 8,080 8,10 8,170 8,170 8,10 8,10 88 (31.1) SHC 8,900 8,940 8,940 8,990 8,990 9,040 9,040 TC 9,170 9,10 9,330 9,440 9,540 9,600 9,660 CI 0.61 0.64 0.58 0.54 0.53 0.57 0.60 7 (.) SHC 4,80 4,330 4,370 4,40 4,460 4,510 4,510 67 76 (4.4) SHC 5,150 5,150 5,00 5,40 5,90 5,330 5,330 (19.4) 80 (6.7) SHC 5,970 6,00 6,060 6,110 6,160 6,160 6,00 84 (8.9) SHC 6,800 6,840 6,890 6,930 6,980 6,980 7,00 88 (31.1) SHC 7,60 7,660 7,710 7,760 7,800 7,850 7,850 TC 8,840 8,900 9,090 9,50 9,400 9,500 9,610 CI 0.69 0.71 0.64 0.59 0.57 0.60 0.6 7 (.) SHC 3,000 3,000 3,090 3,140 3,180 3,30 3,80 71 76 (4.4) SHC 3,80 3,80 3,90 3,960 4,010 4,050 4,100 (1.7) 80 (6.7) SHC 4,690 4,690 4,780 4,830 4,880 4,90 4,970 84 (8.9) SHC 5,50 5,50 5,610 5,650 5,700 5,740 5,790 88 (31.1) SHC 6,340 6,340 6,430 6,480 6,50 6,570 6,610 TC 8,430 8,510 8,770 9,000 9,00 9,340 9,490 CI 0.76 0.79 0.70 0.64 0.61 0.63 0.65 75 76 (4.4) SHC,590,590,680,770,80,860,910 (3.9) 80 (6.7) SHC 3,410 3,460 3,550 3,640 3,690 3,730 3,780 84 (8.9) SHC 4,40 4,80 4,370 4,460 4,510 4,560 4,600 88 (31.1) SHC 5,060 5,100 5,00 5,90 5,330 5,380 5,40 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) 1. NOTE Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.. Above data represents the value when the operation frequency of a compressor is fixed. 34

Indoor Unit : XS187 & PNRXS187 Outdoor Unit : CL187 Power Supply : 30V Single Phase 60Hz < Cooling Capacity (Low Ambient) > RATING CAPACITY: 17,500 BTU/h AIR FLOW RATE: 341 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C) 1. W.B. D.B. 0 5 15 5 35 45 55 (17.8) (15.0) (9.4) (3.9) (1.7) (7.) (1.8) NOTE TC 14,930 14,970 14,980 14,970 15,000 15,040 15,030 CI 0.87 0.91 0.94 0.81 0.79 0.78 0.8 7 (.) SHC 10,530 10,530 10,600 10,530 10,600 10,600 10,600 59 76 (4.4) SHC 11,70 11,790 11,790 11,790 11,790 11,790 11,790 (15.0) 80 (6.7) SHC 1,980 1,980 1,980 1,980 13,050 13,050 13,050 84 (8.9) SHC 14,180 14,180 14,40 14,180 14,40 14,40 14,40 88 (31.1) SHC 14,930 14,970 14,980 14,970 15,000 15,040 15,030 TC 14,710 14,770 14,840 14,940 15,030 15,130 15,180 CI 0.98 1.0 1.03 0.87 0.85 0.8 0.85 7 (.) SHC 8,610 8,680 8,680 8,740 8,810 8,810 8,870 63 76 (4.4) SHC 9,800 9,870 9,870 9,930 10,000 10,070 10,070 (17.) 80 (6.7) SHC 11,060 11,130 11,130 11,190 11,60 11,60 11,330 84 (8.9) SHC 1,60 1,30 1,30 1,390 1,450 1,450 1,50 88 (31.1) SHC 13,450 13,510 13,510 13,580 13,650 13,710 13,710 TC 14,330 14,410 14,560 14,780 14,960 15,130 15,50 CI 1.11 1.14 1.14 0.95 0.91 0.86 0.88 7 (.) SHC 6,690 6,750 6,80 6,890 6,950 7,080 7,080 67 76 (4.4) SHC 7,880 7,950 8,010 8,080 8,140 8,80 8,80 (19.4) 80 (6.7) SHC 9,140 9,10 9,70 9,340 9,400 9,540 9,540 84 (8.9) SHC 10,330 10,400 10,470 10,530 10,600 10,730 10,730 88 (31.1) SHC 11,530 11,590 11,660 11,70 11,860 11,90 11,990 TC 13,770 13,880 14,110 14,480 14,750 15,010 15,00 CI 1.5 1.8 1.7 1.04 0.97 0.91 0.91 7 (.) SHC 4,700 4,760 4,830 4,960 5,100 5,160 5,30 71 76 (4.4) SHC 5,890 5,960 6,00 6,160 6,90 6,360 6,490 (1.7) 80 (6.7) SHC 7,150 7,0 7,80 7,40 7,550 7,610 7,680 84 (8.9) SHC 8,340 8,410 8,480 8,610 8,740 8,810 8,940 88 (31.1) SHC 9,540 9,600 9,670 9,800 9,930 10,000 10,130 TC 13,080 13,10 13,540 14,070 14,440 14,790 15,060 CI 1.38 1.4 1.39 1.13 1.04 0.96 0.95 75 76 (4.4) SHC 4,030 4,030 4,170 4,370 4,500 4,630 4,700 (3.9) 80 (6.7) SHC 5,90 5,90 5,430 5,630 5,760 5,890 5,960 84 (8.9) SHC 6,490 6,490 6,60 6,80 6,950 7,080 7,150 88 (31.1) SHC 7,680 7,680 7,810 8,010 8,140 8,80 8,340 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.. Above data represents the value when the operation frequency of a compressor is fixed. 35

6. ELECTRICAL DATA 61. Electrical Characteristics Indoor Unit Outdoor Unit Cooling XS171 & PNRXS187 C171 Performance at Rating conditions Running amp. A 0.1 Power input W 18 Rating conditions: Indoor air temperature: 80 F (6.7 C) D.B. / 67 F (19.4 C) W.B. Outdoor air temperature: 95 F (35 C) D.B. Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor + Compressor 115V Singlephase 60Hz 1.39 1,4 1.6 1,60 Indoor Unit Outdoor Unit XS171 & PNRXS187 CL171 Cooling Performance at Rating conditions Running amp. A 0.1 Power input W 18 Rating conditions: Indoor air temperature: 80 F (6.7 C) D.B. / 67 F (19.4 C) W.B. Outdoor air temperature: 95 F (35 C) D.B. Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor + Compressor 115V Singlephase 60Hz 1.39 1,4 1.6 1,60 36

Indoor Unit Outdoor Unit XS187 & PNRXS187 C187 Cooling Indoor Unit Fan Motor Performance at Rating conditions Running amp. A 0.15 Power input W Outdoor Unit Fan Motor + Compressor 30V Singlephase 60Hz 8.15 1,838 < 30V > Complete Unit 8.3 1,860 Rating conditions: Indoor air temperature: 80 F (6.7 C) D.B. / 67 F (19.4 C) W.B. Outdoor air temperature: 95 F (35 C) D.B. Cooling Indoor Unit Fan Motor Performance at Rating conditions Running amp. Power input A W 0.16 Rating conditions: Indoor air temperature: 80 F (6.7 C) D.B. / 67 F (19.4 C) W.B. Outdoor air temperature: 95 F (35 C) D.B. Outdoor Unit Fan Motor + Compressor 08V Singlephase 60Hz 8.94 1,838 < 08V > Complete Unit 9.1 1,860 Indoor Unit Outdoor Unit XS187 & PNRXS187 CL187 Cooling Indoor Unit Fan Motor Performance at Rating conditions Running amp. Power input A W 0.15 Rating conditions: Indoor air temperature: 80 F (6.7 C) D.B. / 67 F (19.4 C) W.B. Outdoor air temperature: 95 F (35 C) D.B. Outdoor Unit Fan Motor + Compressor 30V Singlephase 60Hz 8.15 1,838 < 30V > Complete Unit 8.3 1,860 Cooling Indoor Unit Fan Motor Performance at Rating conditions Running amp. Power input A W 0.16 Rating conditions: Indoor air temperature: 80 F (6.7 C) D.B. / 67 F (19.4 C) W.B. Outdoor air temperature: 95 F (35 C) D.B. Outdoor Unit Fan Motor + Compressor 08V Singlephase 60Hz 8.94 1,838 < 08V > Complete Unit 9.1 1,860 37

6. Electric Wiring Diagrams Indoor Unit XS171 & PNRXS187 XS187 & PNRXS187 WARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. FLOAT SWITCH TO OUTDOOR UNIT GND 1 3 TERMINAL BASE FAN MOTOR FM 1 3 4 5 6 1 3 4 5 6 DCM 6P (BLU) 6P (WHT) DRAIN PUMP DP DP 3P (BLU) 3P (RED) PWM/POW 7P (RED) PWM/POW 7P (RED) RC 4P (WHT) SERIAL P (WHT) SERIAL P (WHT) GRN BOX BOX IND LAMP ASSY FLAP (W) IND 7P (WHT) FLAP 5P (WHT) CONTROLLER CONTROLLER FS 3P (RED) ROOM P (YEL) COIL1 P (RED) 8FA55046900 RED BLK WHT YEL BLU YEL/(RED) YEL/(RED) FERRITE CORE AC1AC SI 1 1 3 3 1 1 3 3 4 4 5 5 6 6 7 7 1 1 BRN RED ORG YEL PNK BLU VLT 1 1 1 1 3 3 4 4 5 5 1 1 3 3 4 4 5 5 6 6 7 7 8 8 9 9 1 1 3 3 4 4 5 5 1 1 3 3 4 4 5 5 6 6 7 7 1 1 3 3 4 4 1 1 3 3 4 4 10 10 5 5 6 6 7 7 1 1 3 3 4 4 5 5 6 6 1 1 3 3 1 1 1 1 BLK WHT RED GRN/YEL WHT BLK GRN BRN RED ORG YEL PNK BLU VLT BLK BLK RED WHT THERMISTOR ROOM COIL1 1 1 FLAP (R) 4 5 3 3 4 5 BLK ORG BLU BRN WHT BLK ORG BLU BRN WHT BLK WHT BRN BLU ORG BLK BLK BLK BLK 38

Outdoor Unit C171 WARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. REACTANCE 3PCONNECTOR (WHT) FERRITE CORE RED (PNK) WHT BLU 1 3 1 3 (PNK) RED WHT BLU R/V S/U C/W CM COMPRESSOR MOTOR W U W V W W OUTDOOR 1 1 OUT DOOR THERMISTOR BLK BLK OVERLOAD RELAY (OLR) COIL THERMISTOR COIL/COMP 1 3 4 1 3 4 YEL YEL BLK BLK COMPRESSOR THERMISTOR W L YEL ORG 1 1 YEL ORG W L1 PCONNECTOR (BLK) CONTROLLER DCFM 1 3 4 5 6 7 WHT 1 3 4 5 6 7 1 3 4 5 6 7 WHT BLK RED BLU YEL BLK RED BLU YEL 7PCONNECTOR (WHT) GRN/YEL FM FAN MOTOR GRN/YEL W E MV 1 3 4 5 6 1 3 4 5 6 ORG RED GRY WHT YEL BLK 1 3 4 5 6 1 3 4 5 6 MV MAGNETIC COIL 5A ACIN1 ACIN SI W W W FERRITE CORE BLK WHT RED WHT 6 5 BLK POWER RELAY BLK BLK WHT 1 1 BLK BLK PCONNECTOR (WHT) 1 4 TERMINAL PLATE 1 3 GND 4 5 6 GND TO INDOOR UNIT N L POWER SUPPLY HIGH PRESSURE SWITCH WHT WHT 1 1 PCONNECTOR (BLK) WHT WHT 8FA55769000 39

Outdoor Unit CL171 WARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. REACTANCE 3PCONNECTOR (WHT) FERRITE CORE RED (PNK) WHT BLU 1 3 1 3 (PNK) RED WHT BLU R/V S/U C/W CM COMPRESSOR MOTOR WHT WHT CRANKCASE HEATER 1PCONNECTOR (WHT) 1 1 1PCONNECTOR (WHT) 1 1 W U W V W W OUTDOOR 1 1 OUT DOOR THERMISTOR BLK BLK OVERLOAD RELAY (OLR) WHT COIL THERMISTOR WHT W W CHEATER CHEATER1 COIL/COMP 1 3 4 1 3 4 YEL YEL BLK BLK COMPRESSOR THERMISTOR W L YEL ORG 1 1 YEL ORG W L1 PCONNECTOR (BLK) CONTROLLER DCFM 1 3 4 5 6 7 WHT 1 3 4 5 6 7 1 3 4 5 6 7 WHT BLK RED BLU YEL BLK RED BLU YEL 7PCONNECTOR (WHT) GRN/YEL FM FAN MOTOR GRN/YEL W E MV 1 3 4 5 6 1 3 4 5 6 ORG RED GRY WHT YEL BLK 1 3 4 5 6 1 3 4 5 6 MV MAGNETIC COIL 5A ACIN1 ACIN SI W W W FERRITE CORE BLK WHT RED WHT 6 5 BLK POWER RELAY BLK BLK WHT 1 1 BLK BLK PCONNECTOR (WHT) 1 4 TERMINAL PLATE 1 3 GND 4 5 6 GND TO INDOOR UNIT N L POWER SUPPLY HIGH PRESSURE SWITCH WHT WHT 1 1 PCONNECTOR (BLK) WHT WHT 8FA55769300 40

Outdoor Unit C187 CL187 WARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. REACTANCE PCONNECTOR (WHT) WHT WHT 1 1 WHT WHT BRN WHT BLK BLU RED GRN/YEL GRN/YEL BLK POWER RELAY 6 5 1 4 BLK 3PCONNECTOR (WHT) RED (PNK) WHT BLU 1 3 1 3 (PNK) RED WHT BLU S R T CM FERRITE CORE COMPRESSOR MOTOR COMPRESSOR THERMISTOR W U W V W W COMP 1 1 BLK BLK OVERLOAD RELAY (OLR) W L1 ATH W L 1 3 4 1 3 4 BLK BLK OUT DOOR THERMISTOR W W W W W W W W HIC+ HIC+ BD BD HIC HIC AC AC COIL/OUTDOOR 1 3 4 1 3 4 YEL YEL COIL THERMISTOR CONTROLLER 7PCONNECTOR (WHT) WHT WHT DCFM 1 3 4 5 6 7 BLK RED BLU YEL 1 3 4 5 6 7 1 3 4 5 6 7 BLK RED BLU YEL GRN/YEL FM FAN MOTOR W W A1 A MV0 1 3 4 5 1 3 4 5 ORG RED YEL BLK GRY 1 3 4 5 1 3 4 5 MV W E1 5A MAGNETIC COIL W E ACIN1 W ACIN W SIA W BLK WHT RED WHT FERRITE CORE BLK WHT 1 1 BLK BLK PCONNECTOR (BLK) TERMINAL PLATE 1 3 GND 4 5 6 GND TO INDOOR UNIT N L POWER SUPPLY HIGH PRESSURE SWITCH WHT WHT 1 1 PCONNECTOR (RED) WHT WHT 8FA557686003 41