LOW TEMPERATURE FREEZER MANAGEMENT GUIDE

Similar documents
8L DEHUMIDIFIER OPERATING INSTRUCTIONS

Contents Safety Warnings... 4 Unpacking... 6 Installation... 7 Product Overview Operation Cleaning Maintenance...

REFRIGERAT A OR USE DF1-15 F ridge

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

ST NF60188W ST NF60188STA

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

ULTRA LOW TEMPERATURE FREEZER. User Manual

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

User Manual / Installation Instructions

Chest Freezer. Instruction Manual L150CF12

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

user s information manual

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

KEY CONSIDERATIONS WHEN PURCHASING AN ULTRA-LOW TEMPERATURE FREEZER

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

SPR7-OS SPR601-OS SCR600L-OS SPR601-OSRC SCR600L-OSRC SP6DSSTB-OS

General Care and Safety Guide

Thermo Fisher Scientific ULT Clinic. Peter Diebold Cold Storage Specialist

USING THE REFRIGERATOR COMPARTMENT

Cott Vending Inc. THESE GUIDES ARE FOR MACHINE MODEL: ROYAL 448 AND OTHER NON-ELECTRONIC (NE) ROYAL VENDORS ONLY. Store Level Vending Responsibilities

Contents Safety Warnings... 3 Unpacking... 5 Installation... 6 Product Overview Operation Cleaning Maintenance...

Instruction / Installation Manual. Fridge Freezer LFC60W13

User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers

REFRIGERATOR USER S MANUAL MODEL: HS-306LN

EVAKOOL ELITE - UPRIGHT FRIDGE FREEZERS OPERATING MANUAL

Refrigerator Freezer HD-368RWEW

Cold Storage Management Standard Operation Procedure

WHD-125FW1 //WHD-125FB1/WHD-125FSS1

20L Electronic Dehumidifier

Operating Instructions

Owner s Manual Super-Slim Four-Way Cassette

DECLARATION OF CONFORMITY

BEFORE USING THE APPLIANCE

Ways to Save. Energy efficiency tips to help you lower your monthly power bill. 1 Ways To Save

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Ice Maker. Model BIM25. Instruction Manual. Write Serial Number of unit here:

Contents Safety Warnings... 4 Unpacking... 6 Installation... 7 Product Overview Operation Cleaning Maintenance...

Premium Wine Cellar 12 bottle storage

OUTDOOR ICE MAKER Model BIM24OS

Installation and User's Manual for Refrigerator Model SCR33

1.1 Setup Installation

FR-031DDRVBE1 FR-031DDRVWE

Before Putting Into Use. Important. Tips for Energy Savings

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Instruction Manual. Chest Freezer Model: CF.142L

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

User manual PRO range display chillers and display freezers

INSTRUCTIONS MANUAL FOR MED75HD - UPRIGHT GLASS DOOR FRIDGE

ENERGY EFFICIENCY PROJECTS. NO-COST AND LOW-COST UPGRADES FOR YOUR FACILITY In partnership with: Refrigerating Engineers & Technicians Association

Installation and Operation Guide For

TCW 2000 Ice liner refrigerator and freezer PIJ

Freestanding Wine Cooler Instruction Manual

Chef Base Refrigerators

Glass Door Merchandiser Refrigerator and Freezer

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Refrigerator INSTRUCTION MANUAL W1BF17 & W1WF17

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

User Manual

American Style Fridge Freezer KFF2DW14 / KFF2DS14 / KSBSB15. installation / instructions manual

Contents. For your safety About your product Installing your appliance Using your appliance Care & cleaning...

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

MFC501 & MFC701. Manual for installation, use and maintenance. Integrated fridge-freezers. year.

Fig. 1 - Unit PHD4 and WPH4

BUILT-IN 60CM WHITE UNDERCOUNTER LARDER KIL60W14. installation / instructions manual

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

KF Fridge / Freezer User Guide

Silver Undercounter Larder Fridge

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

Instruction Manual 1.1 CU. FT. Upright Freezer UF-114W (WHITE) UF-114SS (STAINLESS STEEL)

30-pint Dehumidifier User Guide

Owner s Information Manual

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

2.9kW Portable Air Conditioner

Guide to the Heating and Cooling Systems at McLean Gardens

- 1 - Updated on 18 March, 2010

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

Cabinet Refrigerators/Freezers Instruction manual

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

User manual: Stainless steel CSS1 Refrigerator and FSS2 Freezer

COMMERCIAL REFRIGERATOR AND FREEZER USER S MANUAL

Instruction Manual. Refrigerator. Model: HS-65L

Instruction Manual. Fridge Freezer LFC152W14

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

FW851 / FW871 Integrated Fridge Freezer Manual for Installation, Use and Maintenance

Transcription:

Introduction ULTRA-LOW LOW TEMPERATURE FREEZER MANAGEMENT GUIDE Energy-intensive laboratories present promising opportunities to help UEA reduce its carbon emissions. Ultra-low temperature freezers (ULTs) are commonly referred to as -80s, and are defined here as freezers that operate at temperatures below -70 C. Yale University found that they were typically accounting for 66% of the energy used by all lab appliances. An audit of ULTs in UEA s School of Biological Sciences identified that they were using the same amount of electricity annually as 36 UK households, and costing over 16,300. These guidelines provide advice on how you and your lab, department and School can manage your ULTs more effectively to save money, reduce carbon emissions, prolong freezer life and safeguard samples. Day-to to-day Good Practice 1. Ensure that internal doors within freezers are closed properly before the main door is shut, and that both are closed as quickly as possible. This prevents warm air entering and reduces ice build-up. Stick a sign to that effect on the freezer door to encourage others to do the same. 2. Arrange for up-to-date inventories for each unit, detailing what goes where inside each freezer. Stick a copy of this on the freezer door to help users plan ahead and minimise searching times with the door open. 3. Keep samples in boxes and places boxes in racking, to allow for quick retrieval. Racking also increases the space efficiency, allowing for the storage of more samples. 4. Clearly label your samples, including your contact details and an expiry date for the sample. This will facilitate sample audits (see below), as well as keeping your samples safe. 5. Do not overfill freezers. Samples should not block grills, vents or obstruct the airflow to and from the coolers, as this will compromise temperature control. uea.ac.uk/about/sustainability E: sustainability@uea.ac.uk

6. Avoid leaving large empty spaces in freezers. The majority of the energy a freezer uses is spent cooling the air that enters upon opening the freezer door. If large areas of the freezer are empty, use spare polystyrene ice boxes to fill them. 7. Position freezers suitably: a) Store ULTs in a well-ventilated space away from sources of heat such as sunlight or warm rooms. Most hallways are not designed to effectively remove heat generated from ULTs; therefore, ambient temperatures can reach as high as 32 C, especially during summer. Operating ULTs at these ambient temperatures increases energy consumption by as much as 24% and increases the risk of freezer failure, endangering samples. b) Ensure that there is space around the unit s vents to allow it to draw in and expel air. ULTs need at least 20 cm of clear space on the top, and a minimum of 15 cm of clear space at the rear and on both sides. Do not store items on top of or around ULTs. 8. When back-up ULTs are not being used, lower them to a set point temperature of -60 C. This will both reduce energy and extend the life of the freezer, by lowering the duty cycle. 9. Make sure your freezer is reaching its temperature set point. If you can hear the compressor running constantly, or if the freezer is set for -80 C but only reaches -78 C, inform the lab manager and have the unit looked at immediately. 10. Where possible, audit energy usage of every ULT annually to help identify malfunctioning freezers. A number of monitors are available to borrow from the Risk and Sustainability Team within Estates. 11. Develop and maintain an inventory of the ULTs in your department. The key information to record is: The number of ULTs; The design/ model of each freezer; The energy consumption (wattage) of each freezer; The age of each freezer; The location of each freezer, also noting whether anything is being stored on top of or around the freezer.

This information will enable you to: Characterise the age profile of the ULTs in your building as a general rule, older freezers will tend to be less efficient 1 ; Target specific areas or labs for improvements, based on the number and age profile of the ULTs they contain; Develop a schedule for replacing the older and/or more power-hungry freezers; Identify opportunities to improve where and how the freezers are located. Periodic Freezer Maintenance 1. Arrange for regular maintenance checks to be performed on all freezers, ideally on a monthly basis and at least every 6 months. Allocate responsibility for performing these checks to a suitable staff member and have a set timetable. Poor maintenance can increase condensing temperature or reduce evaporating temperature by several degrees, resulting in an increase in energy use of up to 25%. 2. Annex A provides some guidelines on how to carry out routine ULT maintenance. To avoid personal injury and damage to the freezer or samples, the actions described in Annex A should only be carried out by a nominated and suitably qualified staff member. 3. Identify any zombie freezers by regularly testing or metering freezers older than 10 years. Zombie freezers are those that, while still appearing to be fully functional, guzzle two to four times as much energy as a normal freezer. There is some funding available to help replace these: contact sustainability@uea.ac.uk for more information. 4. Clear away any ice build-up with a soft cloth, dustpan and brush, or rubber mallet. Avoid sharp tools and take care not to damage the rubber seals and gaskets. The heat transfer rate in the ULT cabinet is decreased as frost builds up on the evaporator coils, due to the insulating effects of ice. This means the compressor has to work harder and longer to maintain cool temperatures, wasting more energy. Removing the ice regularly can also extend freezer life. 5. If the ice layer is too hard and thick to remove gently, perform a full defrost by following the How to Fully Defrost Your Freezer advice in Annex B. 1 The efficiency of ULTs decreases over time, due to loosening seals, refrigerant loss, degraded lubricants, fatigue in mechanical systems, or poor maintenance. Each year of a ULT s age translates to approximately 3% increase in energy consumption.

Sample Audits and Management Unwanted and unnecessary samples could be taking up precious storage space in your ULTs. The University of Cambridge found that a high percentage of samples in one department (up to 100% in some freezers!) were so poorly labelled that they were unidentifiable to anyone other than the individual who stored them. Nine percent of samples were older than 5 years or belonged to researchers who had left the department. Undertaking a similar audit allows you to review your day-to-day sample management practices. For example, creating a sample database, showing where each sample is stored, the sample owner and expiry date, will help to identify samples that are no longer required, especially if responsibility is assigned for carrying out regular sample reviews. Sharing this database amongst all users can also help to reduce the amount of time that freezers doors are left open whilst individuals try to find particular samples. Sample inventorying is one of the best ways to optimise the use of your freezer. Inventorying methods range from a simple freezer map taped to the door with handwritten information, to database programmes designed specifically for sample tracking. Strategic Measures Several strategic decisions could help UEA to reduce our overall energy use from freezers: Develop a freezer management programme: This would be a comprehensive strategy that would pull together and address all the challenges associated with ULTs: equipment maintenance, sample maintenance, purchasing/retiring, and data gaps. As part of this programme, your lab/department could develop some guidelines on when it is best to replace an old or inefficient ULT with a more efficient model, and adopt stringent procurement standards for new freezers. Charge for the use of old ULTs: Your School could consider charging research groups who continue to use inefficient models or, alternatively, offer a subsidy for the use of more efficient models (for example based on /m 2 ). An older ULT model can cost over 1,000 per annum in electricity, compared to 300 for a New Brunswick U570. There is some funding available to help upgrade equipment for energy efficiency purposes: contact sustainability@uea.ac.uk for more information. Consider -70 C: Only cool samples to the temperature that is absolutely needed. In the majority of cases, samples can be safely stored at -70 C rather than -80 C. A University of Harvard study has demonstrated that antibodies, antigens and nucleic acids can be stably stored for at least 20 years at a temperature of -70 C. Involve staff: run a ULT competition which focuses on separate areas of freezer management over the course of the year.

Annex A: How to Carry Out Routine ULT Maintenance Note: To avoid personal injury and damage to the freezer and samples, these actions should only be carried out by a nominated and suitably qualified staff member. Check the gaskets and rubber seals around the freezer door for leaks, clean them, and keep them free from ice. If the seals are broken, schedule a repair. Broken seals allow cold air (and energy) to escape and warmth to enter. Check the condenser coils. Condensers can become blocked with dust or debris, preventing efficient cooling. This can result in an increase of up to 10kWh per day. Therefore, if the condenser coils are dirty, arrange for them to be cleaned: Check with the lab manager as to whether the freezer is enrolled in a maintenance contract programme and, if so, contact the contractors to arrange for the coils to be cleaned. If the freezer is not enrolled in a maintenance contract programme, follow the How to Clean Condenser Coils section below. Clean the freezer filter by vacuuming. Alternatively, rinse it in clean water and then allow it to dry before replacing it. Dust on the filter blocks the normal air flow through the condenser, which reduces the ability of the ULT to dissipate heat. Any air flow that passes through the clogged filter will carry dirt to deposit on the condenser. Check and clean the rear of the freezer. Keep the radiator at the back clean and free from dust. How to Clean Condenser Coils Disconnect the power to avoid shock or injury. Locate the coils. Condenser coils are thin, tube-like pieces that are connected with fins. For upright -80 C freezers, condenser coils are normally located at the bottom front of the freezer, or mounted on the rear of the freezer. You may need to remove a covering panel or grill. Otherwise you will find the coils behind the freezer s access panel. You will need to remove the access panel, usually by unscrewing each corner. Go over the condenser coils with a vacuuming hose. Brush away stubborn dirt using a coil brush or a narrow paint brush. If there are remaining build-ups on the coils, wipe them away with a rag dampened with warm, soapy water. When done, remove the moisture from the coils with a dry rag. Replace any grills or panels, and plug the freezer back in.

Annex B: How to Fully Defrost Your Freezer Notify all lab users well in advance of defrosting any freezer, so that they can plan their participation and potentially take the opportunity for a contents audit. Be sure to state the date that the freezer will be defrosted, how long the freezer will be out of use for, and ask all users of the freezer to relocate their samples during this time. You should also make it clear that any samples that have not been removed by the specified date will be temporarily relocated; say who will be moving the samples; and where the samples will be relocated to (say exactly where the alternative freezer is located). Also say who will move samples back to the defrosted freezer, and when they will do this. If the freezer is on an alarm system, inform the control office that the freezer has been turned off so they know that no action is required. Before unplugging the freezer, manually remove as much ice as possible by using a rubber mallet or a soft cloth. Doing this will help reduce pools of water forming. Unplug the freezer, leave the door open and wait for the ice to melt. This may take several hours. You can accelerate the process by placing a pot of hot water inside the freezer and then closing the door. Think health and safety! If the floor becomes wet, set up warning screens to alert other lab users. Once thawed out, remove any pools of water and wipe the internal surfaces and doors dry. Check that all doors, door clips, hinges and seals are in good condition to help reduce the build-up of ice. Report any faults to the lab manager or technician. Switch the freezer back on and allow 24 hours for the freezer to chill down and stabilise to the desired temperature before replacing its contents.