IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

Similar documents
Electric OmnipanelII Towel Radiator

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

COM-PAK COM-PAK TWIN. Com-Pak/Com-Pak Twin Heater. Owner s Guide. tested to UL standards PERFECTLY SIMPLE WARMTH FOR ANY ROOM

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

IMPORTANT SAFETY INFORMATION:

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS

IMPORTANT INSTRUCTIONS READ & SAVE

Homeowner s Installation Instructions & Operating Manual

Electric Garage Heater

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Hardwired Electric Garage Heater

Hardwired Electric Garage Heater

QCM979D-38AGO ELECTRIC FIREPLACE HEATER NDF-65NB-3 INSTRUCTION MANUAL

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Gallery Electric Fireplaces

Model: M630-44FDC CAUTION:

LAVA. Installation Manual. Design Glass-Radiator By WarmlyYours. Read all instructions before installing or using this heater.

Gallery Electric Fireplaces

Homeowner s Installation Instructions & Operating Manual

AMBIANCE LINEAR 40 AMBIANCE LINEAR 60 AMBIANCE LINEAR 100 SAFETY INFORMATION AND OPERATIONS MANUAL

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

ELECTRIC FLAT PANEL FIREPLACE HEATER

M650-38A-OAK ELECTRIC FIREPLACE HEATER NDF-65NB-1 INSTRUCTION MANUAL

NO VENTING REQUIRED 120V AC;

FLCH4R Garage and Utility Electric Heater

Wall Mount Electric Fireplace

READ AND SAVE THESE INSTRUCTIONS

HI Industrial Utility Heater HI Soleus Air International

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL

MILLA ELECTRIC FIREPLACE

Installation Instructions and Homeowner's Manual

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Ducoterra Radiant Heating Panel Installation Manual

SOUTHERN ENTERPRISES INC.

Homeowner s Installation Instructions & Operating Manual

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL

50 FLAT PANEL BUILD IN ELECTRIC FIREPLACE

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL IMPORTANT SAFETY INSTRUCTIONS

EF5802R Freestanding Electric Fireplace

R Series B & T2 Model

EF5528RKD Freestanding Electric Fireplace

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

Installation Instructions and Homeowner's Manual

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

ELECTRIC FLAT PANEL FIREPLACE HEATER

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters

MP BB. ElEcTrIc FIrEplAcE HEATEr. INSTrUcTION MANUAl ATTENTION:

OWNER S MANUAL CARTER FIREPLACE. Product code: UPC code: Date of purchase: / /

Wall Hanging Mode. Pedestal Mode

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

Homeowner s Installation Instructions & Operating Manual

FA433300TX. Electric Wall Fireplace. Assembly Instruction

ELECTRIC STOVE HEATER Models: FS2213B

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

Homeowner s Installation Instructions & Operating Manual

Thanks for shopping with Improvements! Springfield Compact Electric Fireplace Item #470279

Electric Fireplace Instruction Manual

PERSONAL SIZE FIREPLACE

FLAME CUBE ELECTRIC FIREPLACE MODEL EF-BLT02 OPERATION MANUAL

INSTALLATION INSTRUCTIONS

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTRUCTIONES IMPORTANTES CONSERVEZ LES PRESENTES INSTRUCTIONS

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Installation & Maintenance Instructions

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz

With Remote Control. English

INFRARED ZONE HEATING SYSTEM

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Com-Pak Heater Benefits You Can Depend On Com-Pak Models Line Model w/o Model w/ Voltage Thermostat Thermostat Watts Amps (1) (2)

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Dallas Floor Standing Fireplace

OWNER S MANUAL FLAT PANEL FIREPLACE HEATER. Model Numbers: Rossano (EF113US) WARNING CAUTION

Electric Garage Heater

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

OWNER S MANUAL FLAT PANEL FIREPLACE HEATER. Wall-Hanging Mode. Free-Standing Mode. Model Numbers: Galena (EF27H) WARNING CAUTION

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

Electric Fireplace. Electric Fireplace

VERNON ELECTRIC FIREPLACE

IMPORTANT SAFETY INFORMATION:

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

... a. Electric Baseboard Heaters IN THIS SECTION J b t S. SY-STEl\t1S, I~C_

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

mr.steam Lexington Collection Feel Good Inc. REFER TO INSTALLATION, MAINTENANCE MANUAL PROVIDED WITH PRODUCT FOR COMPLETE INSTRUCTIONS

ELECTRIC FIREPLACE MODEL NO. OL-L6G

TABLETOP PTC TOWER HEATER

ASSEMBLY AND OPERATION MANUAL

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

Transcription:

Electric Wall Panel Owner s Manual & Installation Instructions 8 Element Wall Panel Front View 8 & 6 Element Wall Panel Side View 6 Element Wall Panel Back View Top 23 1 8 EWP 8 EWP 6 Bottom 17 1 4 2 3 8 L L 2 3 8 L = 24, 36, 48 Thank you for purchasing the Runtal Electric Wall Panel. We are very proud of our workmanship and quality, and we are certain that you will be thoroughly satisfied with your new Runtal Electric Wall Panel. We urge you to contact your local Runtal representative if you have comments or questions. This manual is intended to show installation and care for your Runtal Electric Wall Panel. The electrical wiring connections must be made by a qualified professional electrician. Wiring procedures and connections must be in accordance with the National Electric Code (NEC) and local codes. The Electric Wall Panel must be installed in a horizontal orientation as shown below. Correct Orientation Incorrect Orientations Proper installation requires the Runtal Electric Wall Panel to be in the horizontal position as shown. No other orientations are acceptable. Contents: 1 Electric Wall Panel (EWP) 1 Mounting Hardware Package 1 Owner s Manual Tools Required: Screw Drivers Electric Drill Operating Instructions 1. Runtal Electric Wall Panel must be properly installed before it is used. 2. Runtal Electric Wall Panel must be connected to a switching device, thermostat / relay switch, etc. 3. The heating element and high-limit thermostat should not be tampered with. 4. Individual thermostats used in conjunction with the EWP will determine operational use. 1

Mounting & Installation Overview: The EWP is designed for a very quick and easy wall mounting installation. Simply choose an appropriate location, attach wall brackets to the wall, make the electrical connection, hang the unit on the wall and screw in the lockdowns. Please note that all installations of the Runtal EWP should be in accordance with local building and electrical codes and performed by a licensed installer. Locating the EWP: The Runtal Electric Wall Panel (EWP) is intended to be permanently wall mounted in a horizontal position (please see the drawing for correct orientation). It is recommended that the EWP be mounted no less than 2 above the finished floor. Inspect the desired location for the EWP and insure that there is sufficient room for the unit and that there are no obstacles that might hinder wall mounting. M o u n t i n g EWP Step 1 The EWP is designed so that the wall brackets K12 may be placed on the wall at stud locations. It is recommended that the wall hangers be installed roughly 4 to 6 from either end of the radiator. Determine how much clearance between the floor and the bottom of the EWP is desired (to give you the height you need to place the wall brackets). Mark this location. For Model EWP6: The top of the wall brackets should be 14 plus the floor clearance distance. Example: If you would like to have 2 clearance from the floor, the top of the K12 mounting bracket should be on the wall 16 above the floor (14 for the unit and 2 for clearance). For Model EWP8: The top of the wall brackets should be 19½ plus the floor clearance distance. Example: If you would like to have 2 clearance from the floor, the top of the K12 mounting bracket should be on the wall 21½ above the floor (19½ for the unit and 2 for clearance). Determine how far apart to hang the (K12) mounting brackets. This measurement depends upon the width of the radiator to be installed as noted above. Mark this location. Model EWP6 (back view) 24 Example: A 24 wide EWP should have the mounting brackets a minimum of 12 apart and a maximum of 16 apart (4 to 6 in from either side) Using the appropriate fastener(s), firmly attach the K12 mounting brackets to the Wall in the desired locations. Hang the EWP on the Wall brackets to insure the location is acceptable and that the wall brackets are solidly installed. If the location is acceptable remove the radiator and set aside on the wrapping foam to protect the finish. 17½ 14 K12 Top K12 4 to 6 4 to 6 Example Bottom 2 Minimum Clearance Floor 2

Wiring and Locating EWP Step 2 Thermostat: A line voltage thermostat or a low voltage thermostat with a relay is recommended for room temperature regulation, and for switching off the Electric Wall Panel when not in use. Thermostat and /or relay are by others, and is not supplied with the Runtal Electric Wall Panel. Note: Thermostat location recommendations Locate the thermostat away from the heater and other appliances that give off heat. Locate the thermostat where it will not be in direct sunlight. Locate the thermostat on an inside wall away from drafts. Do not exceed the electrical rating of the thermostat,relay or other switching device. Most thermostats are mounted about 5 feet off the floor. Check with your local code officer, as ADA regulations may apply. Location: For best results locate the Electric Wall Panel on a outside wall, under a window or near an entry door. Voltage: It is important that you verify the electrical supply voltage is the same as the Electric Wall Panel. Connecting a 240 volt Electric Wall Panel to a 120 volt supply will decrease the heaters output: connecting a Electric Wall Panel to a higher voltage may damage the heater and void the warranty. Warning: Do not install heaters against combustible low density cellulose fiberboard surfaces. Keep drapes 2 inches away from the Electric Wall Panel. Do not install Electric Wall Panel heater below an electrical convenience receptacle. To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater. Only install as illustrated in this manual. Name Plate Location: (UL Label) The name plate is located on the right side of the radiator. Factory Wiring Diagram L2 L1 Central Supply Temperature High Limit Step 3 Prepare the EWP for Wall Hanging and Electrification Please be sure to follow all applicable building and electrical codes. It is recommended that the installation be performed by a licensed electrician. The electrical supply must be from the wall at the rear of the radiator. For ease of installation it is recommended that the supply wire coming from the wall be long enough and flexible enough to allow the electrification of the unit while placed face down on the floor (protected to insure the finish on the front of the unit is not damaged) near its wall hung location. Step 4 Run Supply Wires Mark a vertical line where the center of the radiator will be located. Measure down from the top of the wall bracket 12½ for a EWP-6 to determine the point to drill a 2 hole in the wall for the electrical supply wires. Measure down from the top of the wall bracket 18 3 /8 for a EWP-8 to determine the point to drill a 2 hole in the wall for the electrical supply wires. 3

Thermostat Line in Romex / Armored Cable Wire Hub Fitting A White Green Black Cover B Step 5 Attach the Electrical Supply to the Unit Remove the flat square cover from the junction box and discard. Remove the junction box Cover B and install the 1 hub Fitting A to the junction box. Next install the Romex clamp adapter to the 1 hub fitting. Locate the supply wire coming out of the wall and feed it through the restraint into the junction box. Allow as much wire as needed to make the connection to the radiator heater wires. Secure the supply wire by tightening the screws on the wire restraint. Locking Down Wall Panel Use wire nuts to connect the green supply wire to the green grounding wire in the junction box and one of the heater wires to each of the supply wires. Make sure that all wiring connections are secure inside the junction box and replace the bottom junction box cover. The unit is now ready for wall hanging Wall Wall Mounting Bracket K12 Mounting Screw Step 6 Hang the Electrified Unit on the Wall Lift the EWP onto the Wall Brackets while inserting the wiring into the wall. Locate the Lockdown Brackets on the bottom of the radiator and put a mounting screw (with screw cap) through each one into the wall. 1 Hub Fitting A Note: The Runtal EWP is equipped with a manual reset High-Limit Thermostat to insure against overheating. Should the radiator stop working for any reason, Runtal recommends that the power to the unit be shut off at the source (circuit breaker) and a licensed electrician be contacted for service. 4 Floor Lockdown Bracket Mounting Screw and Cap Add Decorative Screw Cap Before Attaching Bracket to Wall.

Mounting Instructions for Rigid Conduit, where Required. Secure the Rigid Conduit Wall Plate (illustration A) and connections in selected wall location, allow six (6 ) inches of supply wire (illustration B) to establish a connection to the radiators junction box. The radiator must be centered with the Rigid Conduit Wall Plate and the wall plate aligned with the back portion of the radiator s electrical junction box, this will allow for access of the supply wires. Lift the EWP onto the Wall Brackets to hang while ensuring the rigid conduit from the mounted wall plate is inserted into the back of the radiator s junction box, the wires are then fed through the bottom of the junction box and connected to the appropriate connections located in the junction box. Use wire nuts to connect the green wire to the green grounding wire in the junction box and one of the heater wires to each of the supply wires. Make sure all wiring connections are secure inside the junction box, replace the bottom cover and affix the bottom cover with the provided screws. The electrified radiator unit is now ready to be securely mounted for wall hanging. The radiator must be secured to the wall at the bottom portion of the radiator with provided Lockdown Brackets. Illustration A Illustration B Green Conduit Nipple Locknut PVC Connector Wall Plate Assembled Rigid Conduit Wall Plate White Black 5

Operation & Maintenance M a i n t e n a n c e & C l e a n i n g Your Runtal Electric Wall Panel (EWP) has been designed to require the absolute minimum maintenance and care under normal use. However, care should be taken when cleaning the surface of the panel. Periodically vacuum across the top of the grille to remove dust from the grille. A slight odor may be noticeable during initial operation and will dissipate within a few hours. The EWP s powder coated finish provides an elegant yet durable finish to a welded steel product. Occasional cleaning of this finish is best done with a water dampened cloth. Under no circumstances should abrasive cleaner be used. Before cleaning make sure the power has been turned off at the circuit breaker panel, and the heating element is cool. Be sure to restore power when cleaning and maintenance is complete. All other servicing should be performed by qualified service personnel. M a x i m u m W at tag e o n a C i r c u i t For installation of multiple electric wall panel radiators, the following chart should be used. The chart indicates supply voltage, circuit breaker rating, minimum wire size, and maximum total wattage of electric radiators on the circuit. Voltage A.C. Circuit Breaker Size Maximum Wattage Minimum Wire Size 120 15 Amp 1440 14/2 with Ground 120 20 Amp 1920 12/2 with Ground 120 30 Amp 2880 10/2 with Ground 208 15 Amp 2496 14/2 with Ground 208 20 Amp 3328 12/2 with Ground 208 30 Amp 4992 10/2 with Ground 240 15 Amp 2880 14/2 with Ground 240 20 Amp 3840 12/2 with Ground 240 30 Amp 5760 10/2 with Ground 6

Important Instructions When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before using this heater. 2. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored. 3. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains away from heater. 4. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become clogged. 5. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electrical shock or fire, or damage the heater. Never tamper with the EWP or any of its components. 6. Use heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. 7. Extreme caution is necessary when any heater is used by or near children or persons which may require supervision and whenever the heater is left operating and unattended 8. Do not operate any heater after it malfunctions. Disconnect power at service panel and have the heater inspected by a reputable electrician before reusing. 9. Do not use outdoors. 10. The EWP should not be in direct contact with water. 11. To disconnect heater, turn controls to off, and turn off power to the heater circuit at main disconnect panel ( or operate internal disconnect switch if provided). 12. The Runtal EWP is equipped with a manual reset High-Limit Thermostat to insure against overheating. Should the radiator stop working for any reason, Runtal recommends that the power to the unit be shut off at the source (circuit breaker) and a licensed electrician be contacted for service. 13. SAVE THESE INSTRUCTIONS Runtal North America, Inc. PO Box 8278, Ward Hill, MA 01835 (Haverhill) Tel: 800-526-2621 s In Canada: 888 829-4901 www.runtalnorthamerica.com 7